메뉴 건너뛰기




Volumn 15, Issue 2 PART I, 2005, Pages 932-935

Effects of spatial nonuniformity of superconducting-tunnel-junction ion detectors on mass spectroscopy

Author keywords

Mass spectroscopy; Particle detectors; Superconducting radiation detectors; Superconductor insulator superconductor devices

Indexed keywords

CALORIMETERS; CRYOGENIC EQUIPMENT; DNA; ELECTRIC FIELDS; ETCHING; ION BEAMS; MASS SPECTROMETRY; MOLECULAR WEIGHT; PARTICLE DETECTORS; PHONONS; PHOTOLITHOGRAPHY; POLYMERS; PROTEINS; RADIATION DETECTORS; SUPERCONDUCTING DEVICES; TANTALUM;

EID: 22044449345     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2005.850126     Document Type: Conference Paper
Times cited : (14)

References (10)
  • 1
    • 0001359192 scopus 로고    scopus 로고
    • Detection of single macromolecules using a cryogenic particle detector coupled to a biopolymer mass spectrometer
    • Jun.
    • D. Twerenbold, J.-L. Vuilleumier, D. Gerber, A. Tadsen, B. Brandt, and P. M. Gillevet, "Detection of single macromolecules using a cryogenic particle detector coupled to a biopolymer mass spectrometer," Appl. Phys. Lett., vol. 68, pp. 3503-3505, Jun. 1996.
    • (1996) Appl. Phys. Lett. , vol.68 , pp. 3503-3505
    • Twerenbold, D.1    Vuilleumier, J.-L.2    Gerber, D.3    Tadsen, A.4    Brandt, B.5    Gillevet, P.M.6
  • 3
    • 0033126156 scopus 로고    scopus 로고
    • Energy sensitive cryogenic detectors for high-mass biomolecule mass spectrometry
    • Oct.
    • M. Frank, S. Labov, G. Westmacott, and W. Benner, "Energy sensitive cryogenic detectors for high-mass biomolecule mass spectrometry," Mass Spectrom. Rev., vol. 18, pp. 155-186, Oct. 1999.
    • (1999) Mass Spectrom. Rev. , vol.18 , pp. 155-186
    • Frank, M.1    Labov, S.2    Westmacott, G.3    Benner, W.4
  • 4
    • 0036494026 scopus 로고    scopus 로고
    • A multichannel superconducting soft x-ray spectrometer for high-resolution spectroscopy of dilute samples
    • Mar.
    • S. Friedrich, T. Funk, O. Drury, S. E. Labov, and S. P. Cramer, "A multichannel superconducting soft x-ray spectrometer for high-resolution spectroscopy of dilute samples," Rev. Sci. Instrum., vol. 73, pp. 1629-1631, Mar. 2002.
    • (2002) Rev. Sci. Instrum. , vol.73 , pp. 1629-1631
    • Friedrich, S.1    Funk, T.2    Drury, O.3    Labov, S.E.4    Cramer, S.P.5
  • 5
    • 1642587725 scopus 로고    scopus 로고
    • Photon energy dependence of spatial nonuniformity in super-conducting tunnel junction detectors between 200 ev and 10 keV
    • May
    • M. Ohkubo, M. Ukibe, T. Zama, T. Ikeuchi, M. Katagiri, and S. Ichimura, "Photon energy dependence of spatial nonuniformity in super-conducting tunnel junction detectors between 200 ev and 10 keV," Nucl. Instrum. Methods in Phys. Res. A, vol. 520, pp. 231-233, May 2004.
    • (2004) Nucl. Instrum. Methods in Phys. Res. A , vol.520 , pp. 231-233
    • Ohkubo, M.1    Ukibe, M.2    Zama, T.3    Ikeuchi, T.4    Katagiri, M.5    Ichimura, S.6
  • 6
    • 1642634499 scopus 로고    scopus 로고
    • Aluminum thickness dependence of spatial profile in niobium-based superconducting tunnel junctions
    • May
    • M. Ukibe, T. Ikeuchi, T. Zama, and M. Ohkubo, "Aluminum thickness dependence of spatial profile in niobium-based superconducting tunnel junctions," Nucl. Instrum. Methods Phys. Res. A, vol. 520, pp. 260-262, May 2004.
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.520 , pp. 260-262
    • Ukibe, M.1    Ikeuchi, T.2    Zama, T.3    Ohkubo, M.4
  • 7
    • 0012191647 scopus 로고    scopus 로고
    • Development of a compact time-of-flight mass spectrometer with a high mass resolution and a wide mass range
    • Apr.
    • N. Saito, K. Koyama, and M. Tanimoto, "Development of a compact time-of-flight mass spectrometer with a high mass resolution and a wide mass range," J. Mass Spectrum. Soc. Jpn., vol. 48, pp. 241-247, Apr. 2000.
    • (2000) J. Mass Spectrum. Soc. Jpn. , vol.48 , pp. 241-247
    • Saito, N.1    Koyama, K.2    Tanimoto, M.3
  • 8
    • 0031165933 scopus 로고    scopus 로고
    • Single photon imaging x-ray spectrometers using low noise current preamplifiers with dc voltage bias
    • Jun.
    • S. Friedrich, K. Segall, M. C. Gaidis, C. M. Wilson, and D. E. Prober, "Single photon imaging x-ray spectrometers using low noise current preamplifiers with dc voltage bias," IEEE Trans. Appl. Super., vol. 7, pp. 3383-3386, Jun. 1997.
    • (1997) IEEE Trans. Appl. Super. , vol.7 , pp. 3383-3386
    • Friedrich, S.1    Segall, K.2    Gaidis, M.C.3    Wilson, C.M.4    Prober, D.E.5
  • 9
    • 0001089997 scopus 로고    scopus 로고
    • Strong nonlinear response of superconducting tunnel junctions due to localized traps
    • Feb.
    • A. Poelaert, A. G. Kozorezov, A. Peacock, and J. K. Wigmore, "Strong nonlinear response of superconducting tunnel junctions due to localized traps," Phy. Rev. Lett., vol. 82, pp. 1257-1260, Feb. 1999.
    • (1999) Phy. Rev. Lett. , vol.82 , pp. 1257-1260
    • Poelaert, A.1    Kozorezov, A.G.2    Peacock, A.3    Wigmore, J.K.4
  • 10
    • 0034029494 scopus 로고    scopus 로고
    • Investigating ion-surface collisions with a niobium superconducting tunnel junction detector in a time-of-flight mass spectrometer
    • G. Westmacott, F. Zhong, M. Frank, S. Friedrich, S. Labov, and W. Benner, "Investigating ion-surface collisions with a niobium superconducting tunnel junction detector in a time-of-flight mass spectrometer," Rapid Commun. Mass Spectrom., vol. 14, pp. 600-607, 2000.
    • (2000) Rapid Commun. Mass Spectrom. , vol.14 , pp. 600-607
    • Westmacott, G.1    Zhong, F.2    Frank, M.3    Friedrich, S.4    Labov, S.5    Benner, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.