메뉴 건너뛰기




Volumn 65, Issue 3, 2005, Pages 442-446

Real-time 3D echocardiography-guided transcatheter device closure of atrial septal defects

Author keywords

3D echocardiography; Amplatzer septal occluder; Cardiac catheterization; Congenital heart disease; Conscious sedation

Indexed keywords

ARTICLE; CASE REPORT; COIL EMBOLIZATION; ENDOTRACHEAL INTUBATION; GENERAL ANESTHESIA; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HUMAN; PRESCHOOL CHILD; REAL TIME ECHOGRAPHY; TECHNIQUE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 21244481729     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20378     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 0032846406 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): Multicentre UK experience
    • Chan KC, Godman MJ, Walsh K, Wilson N, Redington A, Gibbs JL. Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience. Heart 1999;82:300-306.
    • (1999) Heart , vol.82 , pp. 300-306
    • Chan, K.C.1    Godman, M.J.2    Walsh, K.3    Wilson, N.4    Redington, A.5    Gibbs, J.L.6
  • 2
    • 0037108122 scopus 로고    scopus 로고
    • Comparison of transcatheter closure of secundum atrial septal defect using the Amplatzer septal occluder associated with deficient versus sufficient rims
    • Du ZD, Koenig P, Cao QL, Waight D, Heitschmidt M, Hijazi ZM. Comparison of transcatheter closure of secundum atrial septal defect using the Amplatzer septal occluder associated with deficient versus sufficient rims. Am J Cardiol 2002;90:865-869.
    • (2002) Am J Cardiol , vol.90 , pp. 865-869
    • Du, Z.D.1    Koenig, P.2    Cao, Q.L.3    Waight, D.4    Heitschmidt, M.5    Hijazi, Z.M.6
  • 3
    • 1642399800 scopus 로고    scopus 로고
    • Interventional approach to congenital heart disease
    • Holzer R, Hijazi ZM. Interventional approach to congenital heart disease. Curr Opin Cardiol 2004;19:84-90.
    • (2004) Curr Opin Cardiol , vol.19 , pp. 84-90
    • Holzer, R.1    Hijazi, Z.M.2
  • 4
    • 0025276752 scopus 로고
    • Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect
    • Hellenbrand WE, Fahey JT, McGowan FX, Weltin GG, Kleinman CS. Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 1990;66:207-213.
    • (1990) Am J Cardiol , vol.66 , pp. 207-213
    • Hellenbrand, W.E.1    Fahey, J.T.2    McGowan, F.X.3    Weltin, G.G.4    Kleinman, C.S.5
  • 6
    • 0037292892 scopus 로고    scopus 로고
    • Role of intracardiac echocardiographic guidance in transcatheter closure of atrial septal defects and patent foramen ovale using the Amplatzer device
    • Koenig P, Cao QL, Heitschmidt M, Waight DJ, Hijazi ZM. Role of intracardiac echocardiographic guidance in transcatheter closure of atrial septal defects and patent foramen ovale using the Amplatzer device. J Interv Cardiol 2003;16:51-62.
    • (2003) J Interv Cardiol , vol.16 , pp. 51-62
    • Koenig, P.1    Cao, Q.L.2    Heitschmidt, M.3    Waight, D.J.4    Hijazi, Z.M.5
  • 11
    • 0026551445 scopus 로고
    • Percutaneous closure of the small (less than 2.5 mm) patent ductus arteriosus using coil embolization
    • Cambier PA, Kirby WC, Wortham DC, Moore JW. Percutaneous closure of the small (less than 2.5 mm) patent ductus arteriosus using coil embolization. Am J Cardiol 1992;69:815-816.
    • (1992) Am J Cardiol , vol.69 , pp. 815-816
    • Cambier, P.A.1    Kirby, W.C.2    Wortham, D.C.3    Moore, J.W.4
  • 12
    • 0031467061 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: Initial human experience
    • Masura J, Gavora P, Formanek A, Hijazi ZM. Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience. Cathet Cardiovasc Diagn 1997;42:388-393.
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 388-393
    • Masura, J.1    Gavora, P.2    Formanek, A.3    Hijazi, Z.M.4