메뉴 건너뛰기




Volumn 17, Issue 2, 2004, Pages 95-98

Transcatheter atrial septal defect closure assisted by intracardiac echocardiography: 3-Year follow-up

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AORTA VALVE; ARTICLE; BALLOON CATHETER; BALLOON OCCLUSION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; DIAGNOSTIC IMAGING; ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART ATRIUM SEPTUM DEFECT; HUMAN; IMPLANTATION; LOCAL ANESTHESIA; LUNG ARTERY PRESSURE; MAJOR CLINICAL STUDY; MALE; MONITORING; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SAFETY; ULTRASOUND TRANSDUCER;

EID: 2442494899     PISSN: 08964327     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8183.2004.09874.x     Document Type: Article
Times cited : (34)

References (29)
  • 1
    • 0029051378 scopus 로고
    • Intracardiac ultrasound imaging during transseptal catheterization
    • Mitchel JF, Gillam LD, Sanzobrino BW, et al. Intracardiac ultrasound imaging during transseptal catheterization. Chest 1995;108:104-108.
    • (1995) Chest , vol.108 , pp. 104-108
    • Mitchel, J.F.1    Gillam, L.D.2    Sanzobrino, B.W.3
  • 2
    • 0031595824 scopus 로고    scopus 로고
    • Nonfluoroscopic transseptal catheterization: Safety and efficacy of intracardiac echocardiographic guidance
    • Epstein LM, Smith T, TenHoff H. Nonfluoroscopic transseptal catheterization: Safety and efficacy of intracardiac echocardiographic guidance. J Cardiovasc Electrophysiol 1998;9:625-630.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 625-630
    • Epstein, L.M.1    Smith, T.2    TenHoff, H.3
  • 3
    • 0027971449 scopus 로고
    • Intracardiac echocardiography during radiofrequency catheter ablation of cardiac arrhythmias in humans
    • Chu E, Kalman JM, Kwasman MA, et al. Intracardiac echocardiography during radiofrequency catheter ablation of cardiac arrhythmias in humans. J Am Coll Cardiol 1994;24:1351-1357.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1351-1357
    • Chu, E.1    Kalman, J.M.2    Kwasman, M.A.3
  • 4
    • 0030922895 scopus 로고    scopus 로고
    • Use of intracardiac echocardiography in interventional electrophysiology
    • Kalman JM, Olgin JE, Karch MR, et al. Use of intracardiac echocardiography in interventional electrophysiology. Pacing Clin Electrophysiol 1997;20:2248-2262.
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 2248-2262
    • Kalman, J.M.1    Olgin, J.E.2    Karch, M.R.3
  • 5
    • 0030803344 scopus 로고    scopus 로고
    • Electrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance
    • Olgin JE, Kalman JM, Chin M, et al. Electrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance. Circulation 1997;96:2715-2721.
    • (1997) Circulation , vol.96 , pp. 2715-2721
    • Olgin, J.E.1    Kalman, J.M.2    Chin, M.3
  • 6
    • 0028106307 scopus 로고
    • Intracardiac ultrasound measurement of volumes and ejection fraction in normal, infarcted, and aneurysmal left ventricles using a 10-MHz ultrasound catheter
    • Chen C, Guerrero JL, Vazquez de Prada JA, et al. Intracardiac ultrasound measurement of volumes and ejection fraction in normal, infarcted, and aneurysmal left ventricles using a 10-MHz ultrasound catheter. Circulation 1994;90:1481-1491.
    • (1994) Circulation , vol.90 , pp. 1481-1491
    • Chen, C.1    Guerrero, J.L.2    Vazquez De Prada, J.A.3
  • 7
    • 0030050525 scopus 로고    scopus 로고
    • Determination of aortic valve area in valvular aortic stenosis by direct measurement using intracardiac echocardiography: A comparison with the Gorlin and continuity equations
    • Foster GP, Weissman NJ, Picard MH, et al. Determination of aortic valve area in valvular aortic stenosis by direct measurement using intracardiac echocardiography: A comparison with the Gorlin and continuity equations. J Am Coll Cardiol 1996;27:392-398.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 392-398
    • Foster, G.P.1    Weissman, N.J.2    Picard, M.H.3
  • 8
    • 0029143038 scopus 로고
    • Intracardiac ultrasonographic assessment of atrial septal defect area: In vitro validation and technical considerations
    • Vazquez de Prada JA, Jiang L, Chen MH, et al. Intracardiac ultrasonographic assessment of atrial septal defect area: In vitro validation and technical considerations. Am Heart J 1995;130:302-306.
    • (1995) Am Heart J , vol.130 , pp. 302-306
    • Vazquez De Prada, J.A.1    Jiang, L.2    Chen, M.H.3
  • 9
    • 0035143017 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography
    • Hijazi Z, Wang Z, Cao Q, et al. Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography. Catheter Cardiovasc Interven 2001;52:194-199.
    • (2001) Catheter Cardiovasc Interven , vol.52 , pp. 194-199
    • Hijazi, Z.1    Wang, Z.2    Cao, Q.3
  • 10
    • 0037438812 scopus 로고    scopus 로고
    • Intracardiac echocardiography guided device closure of atrial septal defects
    • Mullen MJ, Dias BF, Walker F, et al. Intracardiac echocardiography guided device closure of atrial septal defects. J Am Coll Cardiol 2003;41:285-292.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 285-292
    • Mullen, M.J.1    Dias, B.F.2    Walker, F.3
  • 11
    • 0037448797 scopus 로고    scopus 로고
    • Intracardiac echocadiography is superior to conventional monitoring for guiding device closure of interatrial communications
    • Bartel T, Koronza T, Arjumand J, et al. Intracardiac echocadiography is superior to conventional monitoring for guiding device closure of interatrial communications. Circulation 2003;107:795-797.
    • (2003) Circulation , vol.107 , pp. 795-797
    • Bartel, T.1    Koronza, T.2    Arjumand, J.3
  • 12
    • 0035011403 scopus 로고    scopus 로고
    • Intracardiac ultrasound assessment of atrial septal defect: Comparison with transthoracic echocardiographic, angiocardiographic, and balloon-sizing measurements
    • Jan SL, Hwang B, Lee PC, et al. Intracardiac ultrasound assessment of atrial septal defect: Comparison with transthoracic echocardiographic, angiocardiographic, and balloon-sizing measurements. Cardiovasc Interven Radiol 2001;24:84-89.
    • (2001) Cardiovasc Interven Radiol , vol.24 , pp. 84-89
    • Jan, S.L.1    Hwang, B.2    Lee, P.C.3
  • 13
    • 0036672811 scopus 로고    scopus 로고
    • Intracardiac echocardiography during catheter-based procedures: Ultrasound system, examination technique, and image presentation
    • Zanchetta M, Rigatelli G, Pedon L, et al. Intracardiac echocardiography during catheter-based procedures: Ultrasound system, examination technique, and image presentation. Echocardiography 2002;19:501-507.
    • (2002) Echocardiography , vol.19 , pp. 501-507
    • Zanchetta, M.1    Rigatelli, G.2    Pedon, L.3
  • 14
    • 0037294662 scopus 로고    scopus 로고
    • Role of intracardiac echocardiography in atrial septal abnormalities
    • Zanchetta M, Rigatelli G, Pedon L, et al. Role of intracardiac echocardiography in atrial septal abnormalities. J Interven Cardiol 2003;16:63-77.
    • (2003) J Interven Cardiol , vol.16 , pp. 63-77
    • Zanchetta, M.1    Rigatelli, G.2    Pedon, L.3
  • 15
    • 0037630124 scopus 로고    scopus 로고
    • Intracardiac echocardiography evaluation in secundum atrial septal defect transcatheter closure
    • Zanchetta M, Pedon L, Rigatelli G, et al. Intracardiac echocardiography evaluation in secundum atrial septal defect transcatheter closure. Cardiovasc Interven Radiol 2003;26:52-57.
    • (2003) Cardiovasc Interven Radiol , vol.26 , pp. 52-57
    • Zanchetta, M.1    Pedon, L.2    Rigatelli, G.3
  • 16
    • 0034213812 scopus 로고    scopus 로고
    • Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device
    • Hijazi ZM, Cao Q, Patel HT, et al. Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device. Am J Cardiol 2000;85:1387-1390.
    • (2000) Am J Cardiol , vol.85 , pp. 1387-1390
    • Hijazi, Z.M.1    Cao, Q.2    Patel, H.T.3
  • 17
    • 0031467061 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer Septal Occluder
    • Masura J, Gavora P, Formanek A, et al. Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer Septal Occluder. Cathet Cardiovasc Diagn 1997;42:388-393.
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 388-393
    • Masura, J.1    Gavora, P.2    Formanek, A.3
  • 18
    • 0032054829 scopus 로고    scopus 로고
    • Closure of atrial septal defects with the Amplatzer Occlusion device: Preliminary results
    • Thanopoulos BD, Laskari CV, Tsaousis GS, et al. Closure of atrial septal defects with the Amplatzer Occlusion device: Preliminary results. J Am Coll Cardiol 1998;31:1110-1116.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 1110-1116
    • Thanopoulos, B.D.1    Laskari, C.V.2    Tsaousis, G.S.3
  • 19
    • 0027321632 scopus 로고
    • Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device
    • Boutin C, Musewe NN, Smallhorn JF, et al. Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device. Circulation 1993;88:621-627.
    • (1993) Circulation , vol.88 , pp. 621-627
    • Boutin, C.1    Musewe, N.N.2    Smallhorn, J.F.3
  • 20
    • 0017863110 scopus 로고
    • Measurement of atrial septal defect during cardiac catheterization. Experimental and clinical results
    • King TD, Thompson SL, Mills NL. Measurement of atrial septal defect during cardiac catheterization. Experimental and clinical results. Am J Cardiol 1978;41:537-542.
    • (1978) Am J Cardiol , vol.41 , pp. 537-542
    • King, T.D.1    Thompson, S.L.2    Mills, N.L.3
  • 21
    • 0025797609 scopus 로고
    • Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect
    • Rao PS, Langhough R. Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect. Am Heart J 1991;122:505-508.
    • (1991) Am Heart J , vol.122 , pp. 505-508
    • Rao, P.S.1    Langhough, R.2
  • 22
    • 0026750429 scopus 로고
    • Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion
    • Rao PS, Langhough R, Beekman RH, et al. Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion. Am Heart J 1992;124:172-175.
    • (1992) Am Heart J , vol.124 , pp. 172-175
    • Rao, P.S.1    Langhough, R.2    Beekman, R.H.3
  • 23
    • 0027494271 scopus 로고
    • Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter
    • Godart F, Rey C, Francart C, et al. Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter. Am J Cardiol 1993;72:1095-1097.
    • (1993) Am J Cardiol , vol.72 , pp. 1095-1097
    • Godart, F.1    Rey, C.2    Francart, C.3
  • 24
    • 0025276752 scopus 로고
    • Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect
    • Hellebrand WE, Fahey JT, Mc Gowan FX, et al. Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 1990;66:207-213.
    • (1990) Am J Cardiol , vol.66 , pp. 207-213
    • Hellebrand, W.E.1    Fahey, J.T.2    Mc Gowan, F.X.3
  • 25
    • 0027284977 scopus 로고
    • Biplane transesophageal echo-Doppler studies of atrial septal defects: Quantitative evaluation and monitoring for transcatheter closure
    • Ishii M, Kato H, Inoue O, et al. Biplane transesophageal echo-Doppler studies of atrial septal defects: Quantitative evaluation and monitoring for transcatheter closure. Am Heart J 1993;125:1363-1375.
    • (1993) Am Heart J , vol.125 , pp. 1363-1375
    • Ishii, M.1    Kato, H.2    Inoue, O.3
  • 26
    • 0030995970 scopus 로고    scopus 로고
    • Transvenous closure of secundum atrial septal defects
    • Sharafuddin MJ, Gu X, Titus JL, et al. Transvenous closure of secundum atrial septal defects. Circulation 1997;95:2162-2168.
    • (1997) Circulation , vol.95 , pp. 2162-2168
    • Sharafuddin, M.J.1    Gu, X.2    Titus, J.L.3
  • 27
    • 0032846406 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): Multicentre UK experience
    • Chan KC, Godman MJ, Walsh K, et al. Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): Multicentre UK experience. Heart 1999;82:300-306.
    • (1999) Heart , vol.82 , pp. 300-306
    • Chan, K.C.1    Godman, M.J.2    Walsh, K.3
  • 28
    • 0033120653 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer septal occluder
    • Fischer G, Kramer HH, Stieh J, et al. Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer septal occluder. Eur Heart J 1999;20:541-549.
    • (1999) Eur Heart J , vol.20 , pp. 541-549
    • Fischer, G.1    Kramer, H.H.2    Stieh, J.3
  • 29
    • 0032111711 scopus 로고    scopus 로고
    • Early clinical experience with use of the "Amplatzer Septal Occluder" device for atrial septal defect
    • Wilkinson JL, Goh TH. Early clinical experience with use of the "Amplatzer Septal Occluder" device for atrial septal defect. Cardiol Young 1998;8:295-302.
    • (1998) Cardiol Young , vol.8 , pp. 295-302
    • Wilkinson, J.L.1    Goh, T.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.