메뉴 건너뛰기




Volumn 19, Issue 2, 2004, Pages 84-90

Interventional approach to congenital heart disease

Author keywords

Atrial septal defects; Branch pulmonary artery stenosis; Percutaneous pulmonic valve; Ventricular septal defect

Indexed keywords

ADULT; CATHETER; CONGENITAL HEART DISEASE; DEVICE; FENESTRATION; HEART ATRIUM SEPTUM DEFECT; HEART VENTRICLE SEPTUM DEFECT; HUMAN; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; PRIORITY JOURNAL; REVIEW; TECHNIQUE; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 1642399800     PISSN: 02684705     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001573-200403000-00003     Document Type: Review
Times cited : (56)

References (48)
  • 1
    • 0041666497 scopus 로고    scopus 로고
    • Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: Preliminary experience in children
    • Thanopoulos BD, Tsaousis GS, Karanasios E, et al.: Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience in children. Heart 2003, 89:918-922. This interesting report outlines the most recent experience using the Amplatzer membranous VSD device (pediatric patients only).
    • (2003) Heart , vol.89 , pp. 918-922
    • Thanopoulos, B.D.1    Tsaousis, G.S.2    Karanasios, E.3
  • 2
    • 0037308459 scopus 로고    scopus 로고
    • Initial human experience with the Amplatzer perimembranous ventricular septal occluder device
    • Bass JL, Kalra GS, Arora R, et al.: Initial human experience with the Amplatzer perimembranous ventricular septal occluder device. Catheter Cardiovasc Interv 2003, 58:238-245. This important article reports recent experience of VSD device closure using the Amplatzer membranous VSD device (mainly pediatric patients, few adults).
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 238-245
    • Bass, J.L.1    Kalra, G.S.2    Arora, R.3
  • 3
    • 0037294939 scopus 로고    scopus 로고
    • Transcatheter closure of congenital ventricular septal defects: Experience with various devices
    • Arora R, Trehan V, Kumar A, et al.: Transcatheter closure of congenital ventricular septal defects: experience with various devices. J Interv Cardiol 2003, 16:83-91. This is a report of the largest published experience with VSD device closure to date (mainly pediatric patients, few adults).
    • (2003) J Interv Cardiol , vol.16 , pp. 83-91
    • Arora, R.1    Trehan, V.2    Kumar, A.3
  • 4
    • 1242335098 scopus 로고    scopus 로고
    • Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: Immediate results
    • Holzer RJ, Hijazi ZM, Wilkinson J, et al.: Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: immediate results [abstract]. Catheter Cardiovasc Interv 2003, 60:123.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 123
    • Holzer, R.J.1    Hijazi, Z.M.2    Wilkinson, J.3
  • 5
    • 1642375266 scopus 로고    scopus 로고
    • Modification of Amplatzer device and delivery system to improve placement in the ventricular septal defects
    • Amin Z, Danford DA: Modification of Amplatzer device and delivery system to improve placement in the ventricular septal defects [abstract]. Catheter Cardiovasc Interv 2003, 60:125
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 125
    • Amin, Z.1    Danford, D.A.2
  • 6
    • 1642372017 scopus 로고    scopus 로고
    • Device closure of muscular ventricular septal defects using the Amplatzer muscular VSD occluder: Immediate and mid term results of a US Registry
    • in press
    • Holzer RJ, Balzer D, Cao QL, et al.: Device closure of muscular ventricular septal defects using the Amplatzer muscular VSD occluder: immediate and mid term results of a US Registry. J Am Coll Cardiol 2003, in press. This very important article describes in great detail the results of the US registry of the Amplatzer muscular VSD device (mainly pediatric patients, few adults).
    • (2003) J Am Coll Cardiol
    • Holzer, R.J.1    Balzer, D.2    Cao, Q.L.3
  • 7
    • 0742305172 scopus 로고    scopus 로고
    • Transcatheter closure of post infarction ventricular septal defects using the new Amplatzer muscular VSD occluder: Results of a US Registry
    • in press
    • Holzer RJ, Balzer D, Amin Z, et al.: Transcatheter closure of post infarction ventricular septal defects using the new Amplatzer muscular VSD occluder: results of a US Registry. Catheter Cardiovasc Interv 2003, in press. This reports on the most experience using the Amplatzer postinfarction VSD device to date (adult patients only).
    • (2003) Catheter Cardiovasc Interv
    • Holzer, R.J.1    Balzer, D.2    Amin, Z.3
  • 8
    • 0037336647 scopus 로고    scopus 로고
    • Postinfarction ventricular septal defect closure with Amplatzer occluders
    • Szkutnik M, Bialkowski J, Kusa J, et al.: Postinfarction ventricular septal defect closure with Amplatzer occluders. Eur J Cardiothorac Surg 2003, 23:323-327. This article reports recent experience of device closure of post infarction VSDs in nonacute patients (adult patients only).
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 323-327
    • Szkutnik, M.1    Bialkowski, J.2    Kusa, J.3
  • 9
    • 0038048887 scopus 로고    scopus 로고
    • Transcatheter closure of recurrent postmyocardial infarction ventricular septal defects utilizing the Amplatzer postinfarction VSD device: A case series
    • Goldstein JA, Casserly IP, Balzer DT, et al.: Transcatheter closure of recurrent postmyocardial infarction ventricular septal defects utilizing the Amplatzer postinfarction VSD device: a case series. Catheter Cardiovasc Interv 2003, 59:238-243. Successful closure of recurrent postinfarction VSDs in four nonacute patients after initial surgical closure is reported (adult patients only).
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 238-243
    • Goldstein, J.A.1    Casserly, I.P.2    Balzer, D.T.3
  • 10
    • 0028043771 scopus 로고
    • Primary transcatheter umbrella closure of perimembranous ventricular septal defect
    • Rigby ML, Redington AN: Primary transcatheter umbrella closure of perimembranous ventricular septal defect. Br Heart J 1994, 72:368-371. This article describes early experience with device closure of perimembranous VSDs (pediatric patients only).
    • (1994) Br Heart J , vol.72 , pp. 368-371
    • Rigby, M.L.1    Redington, A.N.2
  • 11
    • 0037108122 scopus 로고    scopus 로고
    • Comparison of transcatheter closure of secundum atrial septal defect using the amplatzer septal occluder associated with deficient-vs-sufficient rims
    • 10a Du DZ, Koenig P, Cao QL, et al.: Comparison of transcatheter closure of secundum atrial septal defect using the amplatzer septal occluder associated with deficient-vs-sufficient rims. Am J Cardiol 2002, 90:865-869.
    • (2002) Am J Cardiol , vol.90 , pp. 865-869
    • Du, D.Z.1    Koenig, P.2    Cao, Q.L.3
  • 12
    • 0036716268 scopus 로고    scopus 로고
    • Growth of an atrial septal defect: Missing the window for transcatheter closure
    • Tortoriello TA, McMahon C, Kovalchin JP, et al.: Growth of an atrial septal defect: missing the window for transcatheter closure. Pediatr Cardiol 2002, 23:542-544. This article highlights the potential for enlargement of ASDs, which can render a transcatheter approach unsuitable (pediatric patients only).
    • (2002) Pediatr Cardiol , vol.23 , pp. 542-544
    • Tortoriello, T.A.1    McMahon, C.2    Kovalchin, J.P.3
  • 13
    • 0036842161 scopus 로고    scopus 로고
    • Transcatheter patch occlusion of experimental atrial septal defects
    • Sideris EB, Sideris CE, Stamatelopoulos SF, et al.: Transcatheter patch occlusion of experimental atrial septal defects. Catheter Cardiovasc Interv 2002, 57:404-407. A new approach to ASD closure using patch and specified balloon catheters is described (animal study).
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 404-407
    • Sideris, E.B.1    Sideris, C.E.2    Stamatelopoulos, S.F.3
  • 14
    • 0037219410 scopus 로고    scopus 로고
    • Cardiac perforation following transcatheter PFO closure
    • Trepels T, Zeplin H, Sievert H, et al.: Cardiac perforation following transcatheter PFO closure. Catheter Cardiovasc Interv 2003, 58:111-113.
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 111-113
    • Trepels, T.1    Zeplin, H.2    Sievert, H.3
  • 15
    • 0036790757 scopus 로고    scopus 로고
    • A new Amplatzer device to maintain patency of Fontan fenestrations and atrial septal defects
    • Amin Z, Danford DA, Pedra CA: A new Amplatzer device to maintain patency of Fontan fenestrations and atrial septal defects. Catheter Cardiovasc Interv 2002, 57:246-251. This article describes the fenestrated Amplatzer septal occluder (pediatric patients only).
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 246-251
    • Amin, Z.1    Danford, D.A.2    Pedra, C.A.3
  • 16
    • 1642397914 scopus 로고    scopus 로고
    • Initial results using the new cribriform Amplatzer septal occluder for transcatheter closure of multifenestrated atrial septal defects with septal aneurysm
    • Cheatham JP, Hill SL, Chisolm JL: Initial results using the new cribriform Amplatzer septal occluder for transcatheter closure of multifenestrated atrial septal defects with septal aneurysm [abstract]. Catheter Cardiovasc Interv 2003, 60:126.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 126
    • Cheatham, J.P.1    Hill, S.L.2    Chisolm, J.L.3
  • 17
    • 0037292924 scopus 로고    scopus 로고
    • Patent foramen ovale with paradoxical embolism: Mid-term results of transcatheter closure in 256 patients
    • Onorato E, Melzi G, Casilli F, et al.: Patent foramen ovale with paradoxical embolism: mid-term results of transcatheter closure in 256 patients. J Interv Cardiol 2003, 16:43-50. This article reports a large cohort of patients who underwent patent foramen ovale device closure (mainly adult patients, few pediatric patients).
    • (2003) J Interv Cardiol , vol.16 , pp. 43-50
    • Onorato, E.1    Melzi, G.2    Casilli, F.3
  • 18
    • 0037294937 scopus 로고    scopus 로고
    • Transcatheter closure of patent foramen ovale: A new migraine treatment?
    • Morandi E, Anzola GP, Angeli S, et al.: Transcatheter closure of patent foramen ovale: a new migraine treatment? J Interv Cardiol 2003, 16:39-42. This is a very important article because it suggests a potential new indication for patent foramen ovale device closure (mainly adult patients).
    • (2003) J Interv Cardiol , vol.16 , pp. 39-42
    • Morandi, E.1    Anzola, G.P.2    Angeli, S.3
  • 19
    • 0035107229 scopus 로고    scopus 로고
    • Early experience with the Amplatzer ductal occluder for closure of the persistently patent ductus arteriosus
    • Ebeid MR, Masura J, Hijazi ZM: Early experience with the Amplatzer ductal occluder for closure of the persistently patent ductus arteriosus. J Interv Cardiol 2001, 14:33-36.
    • (2001) J Interv Cardiol , vol.14 , pp. 33-36
    • Ebeid, M.R.1    Masura, J.2    Hijazi, Z.M.3
  • 20
    • 0036735279 scopus 로고    scopus 로고
    • First closure of a large patent ductus arteriosus in an infant with an angulated nitinol plug
    • Ewert P, Kretschmar O, Nuernberg JH, et al.: First closure of a large patent ductus arteriosus in an infant with an angulated nitinol plug. Catheter Cardiovasc Interv 2002, 57:88-91. This is the first description of use of the angulated Amplatzer ductal occluder in pediatric patients.
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 88-91
    • Ewert, P.1    Kretschmar, O.2    Nuernberg, J.H.3
  • 21
    • 0037308586 scopus 로고    scopus 로고
    • Transcatheter occlusion of patent ductus asteriosus using a new angled Amplatzer duct occluder: Initial clinical experience
    • Masura J, Gavora P, Podnar T: Transcatheter occlusion of patent ductus asteriosus using a new angled Amplatzer duct occluder: initial clinical experience. Catheter Cardiovasc Interv 2003, 58:261-267. This series of patients underwent patent ductus arteriosus device closure using the new angulated Amplatzer ductal occluder with excellent results (pediatric patents only).
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 261-267
    • Masura, J.1    Gavora, P.2    Podnar, T.3
  • 22
    • 1642275954 scopus 로고    scopus 로고
    • Initial experience with the Nit-Occlud PDA occlusion system for closure of patent ductus arteriosus
    • Chisolm JL, Hill SL, Hardin J, et al.: Initial experience with the Nit-Occlud PDA occlusion system for closure of patent ductus arteriosus [abstract]. Catheter Cardiovasc Interv 2003, 60:123.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 123
    • Chisolm, J.L.1    Hill, S.L.2    Hardin, J.3
  • 23
    • 0038636537 scopus 로고    scopus 로고
    • Interventional strategies in the management of peripheral pulmonary artery stenosis
    • Trivedi KR, Benson LN: Interventional strategies in the management of peripheral pulmonary artery stenosis. J Interv Cardiol 2003, 16:171-188. This excellent review outlines the current strategies in management of branch pulmonary artery stenosis, based on mainly pediatric patients.
    • (2003) J Interv Cardiol , vol.16 , pp. 171-188
    • Trivedi, K.R.1    Benson, L.N.2
  • 24
    • 0037299631 scopus 로고    scopus 로고
    • Effect of cutting balloon angioplasty on resistant pulmonary artery stenosis
    • 22a Bergersen LJ, Perry SB, Lock JE. Effect of cutting balloon angioplasty on resistant pulmonary artery stenosis. Am J Cardiol 2003, 91:185-189.
    • (2003) Am J Cardiol , vol.91 , pp. 185-189
    • Bergersen, L.J.1    Perry, S.B.2    Lock, J.E.3
  • 25
    • 0037390824 scopus 로고    scopus 로고
    • Severe aortic coarctation in infants less than 3 months: Successful palliation by balloon angioplasty
    • Rao PS, Jureidini SB, Balfour IC, et al.: Severe aortic coarctation in infants less than 3 months: successful palliation by balloon angioplasty. J Invasive Cardiol 2003, 15:202-208. This series is very important because it describes the successful transcatheter management of native coarctation in a larger number of children younger than 3 months of age (pediatric patients only).
    • (2003) J Invasive Cardiol , vol.15 , pp. 202-208
    • Rao, P.S.1    Jureidini, S.B.2    Balfour, I.C.3
  • 26
    • 0037114822 scopus 로고    scopus 로고
    • Palliative stent implantation for aortic coarctation in premature infants weighing <1,500 g
    • Radtke WA, Waller BR, Hebra A, et al.: Palliative stent implantation for aortic coarctation in premature infants weighing <1,500 g. Am J Cardiol 2002, 90:1409-1412. This article demonstrates that palliative stent implantation using an approach with carotid cutdown is feasible in small infants (pediatric patients only).
    • (2002) Am J Cardiol , vol.90 , pp. 1409-1412
    • Radtke, W.A.1    Waller, B.R.2    Hebra, A.3
  • 27
    • 1642328044 scopus 로고    scopus 로고
    • Transcatheter therapy of coarctation of the aorta by the use of the Cheatham-Platinum-Stent
    • Ewert P, Kretschmar O, Nuernberg JH, et al.: Transcatheter therapy of coarctation of the aorta by the use of the Cheatham-Platinum-Stent [abstract]. Catheter Cardiovasc Interv 2003, 60:129.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 129
    • Ewert, P.1    Kretschmar, O.2    Nuernberg, J.H.3
  • 28
    • 0037314733 scopus 로고    scopus 로고
    • Endoluminal repair of aneurysms associated with coarctation
    • Bell RE, Taylor PR, Aukett M, et al.: Endoluminal repair of aneurysms associated with coarctation. Ann Thorac Surg 2003, 75:530-533. This article highlights the benefits of covered stents in treating aneurysms associated with coarctation of the aorta (adult patients only).
    • (2003) Ann Thorac Surg , vol.75 , pp. 530-533
    • Bell, R.E.1    Taylor, P.R.2    Aukett, M.3
  • 29
    • 0038778518 scopus 로고    scopus 로고
    • Percutaneous pulmonary valve replacement: Towards a modification of the prosthesis
    • Boudjemline Y, Agnoletti G, Piechaud JF, et al.: [Percutaneous pulmonary valve replacement: towards a modification of the prosthesis.] Arch Mal Coeur Vaiss 2003, 96:461-466.
    • (2003) Arch Mal Coeur Vaiss , vol.96 , pp. 461-466
    • Boudjemline, Y.1    Agnoletti, G.2    Piechaud, J.F.3
  • 30
    • 0042122501 scopus 로고    scopus 로고
    • Self-expandable valved stent of large size: Off-bypass implantation in pulmonary position
    • Zhou JQ, Corno AF, Huber CH, et al.: Self-expandable valved stent of large size: off-bypass implantation in pulmonary position. Eur J Cardiothorac Surg 2003, 24:212-216. This important article highlights a novel periventricular approach to implant valved stents in pulmonary position (animal study).
    • (2003) Eur J Cardiothorac Surg , vol.24 , pp. 212-216
    • Zhou, J.Q.1    Corno, A.F.2    Huber, C.H.3
  • 31
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A, et al.: Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002, 106:3006-3008. This is the report of the first successful transcatheter implantation of a valved stent in aortic position using a transseptal approach (adult patients only).
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 32
    • 0036894273 scopus 로고    scopus 로고
    • Hybrid approaches to complex congenital cardiac surgery
    • Hjortdal VE, Redington AN, de Levai MR, et al.: Hybrid approaches to complex congenital cardiac surgery. Eur J Cardiothorac Surg 2002, 22:885-890. This interesting article outlines many variants of the hybrid approach to congenital heart disease (mainly pediatric patients, few adults).
    • (2002) Eur J Cardiothorac Surg , vol.22 , pp. 885-890
    • Hjortdal, V.E.1    Redington, A.N.2    De Levai, M.R.3
  • 33
    • 0346434100 scopus 로고    scopus 로고
    • Perventricular device closure of muscular ventricular septal defects on the beating heart: Technique and results
    • in press
    • Bacha E, Cao QL, Starr JP, et al.: Perventricular device closure of muscular ventricular septal defects on the beating heart: technique and results. J Thorac Cardiovasc Surg 2003, in press. This very important article is the first to highlight a novel periventricular approach to close muscular VSDs without the use of cardiopulmonary bypass (pediatric patients only).
    • (2003) J Thorac Cardiovasc Surg
    • Bacha, E.1    Cao, Q.L.2    Starr, J.P.3
  • 34
    • 0038824178 scopus 로고    scopus 로고
    • Stenting of the ductus arteriosus and banding of the pulmonary arteries: Basis for various surgical strategies in newborns with multiple left heart obstructive lesions
    • Michel-Behnke I, Akintuerk H, Marquardt I, et al.: Stenting of the ductus arteriosus and banding of the pulmonary arteries: basis for various surgical strategies in newborns with multiple left heart obstructive lesions. Heart 2003, 89:645-650. This important article presents one center's experience with treating 20 patients with left heart obstructive lesions using percutaneous ductal stenting and surgical bilateral pulmonary artery banding (pediatric patients only).
    • (2003) Heart , vol.89 , pp. 645-650
    • Michel-Behnke, I.1    Akintuerk, H.2    Marquardt, I.3
  • 35
    • 0037292931 scopus 로고    scopus 로고
    • Percutaneous mitral valve repair for mitral regurgitation
    • Block PC: Percutaneous mitral valve repair for mitral regurgitation. J Interv Cardiol 2003, 16:93-96.
    • (2003) J Interv Cardiol , vol.16 , pp. 93-96
    • Block, P.C.1
  • 36
    • 1642381767 scopus 로고    scopus 로고
    • Transcatheter treatment of obstructed modified Blalock-Taussig shunts
    • Lutterman J, Koopot R: Transcatheter treatment of obstructed modified Blalock-Taussig shunts [abstract]. Catheter Cardiovasc Interv 2003, 60:134.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 134
    • Lutterman, J.1    Koopot, R.2
  • 37
    • 0037678440 scopus 로고    scopus 로고
    • The Genesis stent: A new low-profile stent for use in infants, children, and adults with congenital heart disease
    • Forbes TJ, Rodriguez-Cruz E, Amin Z, et al.: The Genesis stent: a new low-profile stent for use in infants, children, and adults with congenital heart disease. Catheter Cardiovasc Interv 2003, 59:406-414. This article describes a newly modified version of the Genesis stent.
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 406-414
    • Forbes, T.J.1    Rodriguez-Cruz, E.2    Amin, Z.3
  • 38
    • 1642334491 scopus 로고    scopus 로고
    • First experience with a new reexpandable "growth stent" for the treatment of vessel stenosis in infants and small children
    • Ewert P, Kretschmar O, Riesenkampff E, et al.: First experience with a new reexpandable "growth stent" for the treatment of vessel stenosis in infants and small children [abstract]. Catheter Cardiovasc Interv 2003, 60:125.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 125
    • Ewert, P.1    Kretschmar, O.2    Riesenkampff, E.3
  • 39
    • 1642331219 scopus 로고    scopus 로고
    • Use of 3Fr catheters for diagnostic and interventional procedures in newborns and small infants
    • Agnoletti G, Boudjemline Y, Largen E, et al.: Use of 3Fr catheters for diagnostic and interventional procedures in newborns and small infants [abstract]. Catheter Cardiovasc Interv 2003, 60:140.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 140
    • Agnoletti, G.1    Boudjemline, Y.2    Largen, E.3
  • 40
    • 1642368698 scopus 로고    scopus 로고
    • A new technique for direct pulmonary artery pressure measurement in shunt dependent cardiac lesions
    • Froemming S, Fletcher SE, Amin Z: A new technique for direct pulmonary artery pressure measurement in shunt dependent cardiac lesions [abstract]. Catheter Cardiovasc Interv 2003, 60:138.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 138
    • Froemming, S.1    Fletcher, S.E.2    Amin, Z.3
  • 41
    • 1642375265 scopus 로고    scopus 로고
    • Radiofrequency perforation of the atrial septum: Preliminary experimental evaluation and development
    • Veldtman G, Peirone A, Benson LN: Radiofrequency perforation of the atrial septum: preliminary experimental evaluation and development [abstract]. Catheter Cardiovasc Interv 2003, 60:132.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 132
    • Veldtman, G.1    Peirone, A.2    Benson, L.N.3
  • 42
    • 1642363793 scopus 로고    scopus 로고
    • Rapid right ventricular pacing as an alternative to adenosine in interventions for congenital heart disease
    • Daehnert I, Rotzsch C: Rapid right ventricular pacing as an alternative to adenosine in interventions for congenital heart disease [abstract]. Catheter Cardiovasc Interv 2003, 60:133.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 133
    • Daehnert, I.1    Rotzsch, C.2
  • 43
    • 0037438812 scopus 로고    scopus 로고
    • Intracardiac echocardiography guided device closure of atrial septal defects
    • Mullen MJ, Dias BF, Walker F, et al.: Intracardiac echocardiography guided device closure of atrial septal defects. J Am Coll Cardiol 2003, 41:285-292. This is a series of intracardiac echocardiography to facilitate ASD device closure (adult patients only).
    • (2003) J Am Coll Cardiol , vol.41 , pp. 285-292
    • Mullen, M.J.1    Dias, B.F.2    Walker, F.3
  • 44
    • 0037292892 scopus 로고    scopus 로고
    • Role of intracardiac echocardiographic guidance in transcatheter closure of atrial septal defects and patent foramen ovale using the Amplatzer device
    • Koenig P, Cao QL, Heitschmidt M, et al.: Role of intracardiac echocardiographic guidance in transcatheter closure of atrial septal defects and patent foramen ovale using the Amplatzer device. J Interv Cardiol 2003, 16:51-62. This is the largest series of intracardiac echocardiography used in ASD device closure to date (predominantly adults, mixed patients).
    • (2003) J Interv Cardiol , vol.16 , pp. 51-62
    • Koenig, P.1    Cao, Q.L.2    Heitschmidt, M.3
  • 45
    • 0037448797 scopus 로고    scopus 로고
    • Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications
    • Bartel T, Konorza T, Arjumand J, et al.: Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications. Circulation 2003, 107:795-797. This series compares intracardiac echocardiography with transesophageal echocardiography to facilitate ASD device closure (adult patients only).
    • (2003) Circulation , vol.107 , pp. 795-797
    • Bartel, T.1    Konorza, T.2    Arjumand, J.3
  • 46
    • 0037822013 scopus 로고    scopus 로고
    • Transthoracic three-dimensional echocardiography prior to closure of atrial septal defects in children
    • Acar P, Roux D, Dulac Y, et al.: Transthoracic three-dimensional echocardiography prior to closure of atrial septal defects in children. Cardiol Young 2003, 13:58-63. This article describes three-dimensional echocardiography and ASD device closure (mainly pediatric patients).
    • (2003) Cardiol Young , vol.13 , pp. 58-63
    • Acar, P.1    Roux, D.2    Dulac, Y.3
  • 47
    • 0036708270 scopus 로고    scopus 로고
    • Assessment of muscular ventricular septal defect closure by transcatheter or surgical approach: A three-dimensional echocardiographic study
    • Acar P, Abdel-Massih T, Douste-Blazy MY, et al.: Assessment of muscular ventricular septal defect closure by transcatheter or surgical approach: a three-dimensional echocardiographic study. Eur J Echocardiogr 2002, 3:185-191. This article discusses the potential of three-dimensional echocardiography in cardiac interventions (mainly pediatric patients, few adults).
    • (2002) Eur J Echocardiogr , vol.3 , pp. 185-191
    • Acar, P.1    Abdel-Massih, T.2    Douste-Blazy, M.Y.3
  • 48
    • 0037622184 scopus 로고    scopus 로고
    • Magnetic resonance imaging guided cardiovascular interventions in congenital heart diseases
    • Rickers C, Seethamraju RT, Jerosch-Herold M, et al.: Magnetic resonance imaging guided cardiovascular interventions in congenital heart diseases. J Interv Cardiol 2003, 16:143-147. This article highlights and describes the potentials and limitations of cardiac interventions under MRI guidance.
    • (2003) J Interv Cardiol , vol.16 , pp. 143-147
    • Rickers, C.1    Seethamraju, R.T.2    Jerosch-Herold, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.