1
-
-
0025679123
-
Dislocation after total hip arthroplasty: Causes and preventions
-
McCollum, D. E. and Gray, W. J. Dislocation after total hip arthroplasty: Causes and preventions. Clin. Orthop. Related Res., 1990, 261, 159-170.
-
(1990)
Clin. Orthop. Related Res.
, vol.261
, pp. 159-170
-
-
McCollum, D.E.1
Gray, W.J.2
-
3
-
-
9844225382
-
The evolution of a surgical robot from prototype to human clinical use
-
Pittsburgh, Pennsylvania, USA
-
Mittelstadt, B. D., Kazanzides, P., Zuhars, J. F., Williamson, B., Cain, P. W., Smith, F., and Bargar, W. L. The evolution of a surgical robot from prototype to human clinical use. In Proceedings of the 1st International Symposium on Medical Robots and Computer Assisted Surgery, Pittsburgh, Pennsylvania, USA, 1994, pp. 36-41.
-
(1994)
Proceedings of the 1st International Symposium on Medical Robots and Computer Assisted Surgery
, pp. 36-41
-
-
Mittelstadt, B.D.1
Kazanzides, P.2
Zuhars, J.F.3
Williamson, B.4
Cain, P.W.5
Smith, F.6
Bargar, W.L.7
-
4
-
-
0033182557
-
Computer-integrated revision total hip replacement surgery: Concept and preliminary results
-
Taylor, R. H., Joskowicz, L., Williamson, B., Guéziec, A., Kalvin, A., Kazanzides, P., Van Vorhis, R., Yao, J., Kumar, R., Bzostek, A., Börner, M., and Lahmer, A. Computer-integrated revision total hip replacement surgery: Concept and preliminary results. Med. Image Analysis, 1999, 3(3), 301-319.
-
(1999)
Med. Image Analysis
, vol.3
, Issue.3
, pp. 301-319
-
-
Taylor, R.H.1
Joskowicz, L.2
Williamson, B.3
Guéziec, A.4
Kalvin, A.5
Kazanzides, P.6
Van Vorhis, R.7
Yao, J.8
Kumar, R.9
Bzostek, A.10
Börner, M.11
Lahmer, A.12
-
5
-
-
0142142257
-
Total knee replacement using the ROBODOC® system
-
Davos, Switzerland
-
Wiesel, U., Lahmer, A., Tenbusch, M., and Börner, M. Total knee replacement using the ROBODOC® system. In Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 2001, p. 88.
-
(2001)
Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery
, pp. 88
-
-
Wiesel, U.1
Lahmer, A.2
Tenbusch, M.3
Börner, M.4
-
6
-
-
0029035605
-
An integrated system for cementless total hip replacement: Robotics and medical imaging technology enhance precision surgery
-
Kazanzides, P., Mittelstadt, B. D., Musits, B. L., Bargar, W. L., Zuhars, J. F., Williamson, B., Cain, P. W., and Carbone, E. J. An integrated system for cementless total hip replacement: Robotics and medical imaging technology enhance precision surgery. IEEE Engng Medicine Biol. Mag., 1995, 14(3), 307-313.
-
(1995)
IEEE Engng Medicine Biol. Mag.
, vol.14
, Issue.3
, pp. 307-313
-
-
Kazanzides, P.1
Mittelstadt, B.D.2
Musits, B.L.3
Bargar, W.L.4
Zuhars, J.F.5
Williamson, B.6
Cain, P.W.7
Carbone, E.J.8
-
7
-
-
0038008744
-
Geometric accuracy in computer-assisted surgery for total hip replacement
-
Davos, Switzerland
-
Schneider, J. and Kalender, W. Geometric accuracy in computer-assisted surgery for total hip replacement. In Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 2001, p. 20.
-
(2001)
Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery
, pp. 20
-
-
Schneider, J.1
Kalender, W.2
-
8
-
-
20444417208
-
In vitro evaluation of robotic hip implantation efficacy
-
Comparison of matched-pair femurs prepared manually and with ROBODOC® system. Transactions of the 46th Annual Meeting of the Orthopaedic Research Society, Orlando, Florida, USA
-
Wenger, K. H., Gossé, F., Knabe, K., and Wirth, C. In vitro evaluation of robotic hip implantation efficacy. Comparison of matched-pair femurs prepared manually and with ROBODOC® system. Transactions of the 46th Annual Meeting of the Orthopaedic Research Society, Orlando, Florida, USA, 2000, p. 513.
-
(2000)
, pp. 513
-
-
Wenger, K.H.1
Gossé, F.2
Knabe, K.3
Wirth, C.4
-
9
-
-
0031719836
-
Primary and revision total hip replacement using the ROBODOC® system
-
Bargar, W. L., Bauer, A., and Börner, M. Primary and revision total hip replacement using the ROBODOC® system. Clin. Orthop. Related Res., 1998, 354, 82-91.
-
(1998)
Clin. Orthop. Related Res.
, vol.354
, pp. 82-91
-
-
Bargar, W.L.1
Bauer, A.2
Börner, M.3
-
10
-
-
20444399286
-
Accuracy of spatial positioning of robotassisted hip endoprosthesis
-
Davos, Switzerland
-
Gehrke, T., Wiese, K., Hahne, H. J., and Hassenpflug, J. Accuracy of spatial positioning of robotassisted hip endoprosthesis. In Proceedings of the 4th International Symposium on Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 1999, p. 20.
-
(1999)
Proceedings of The4th International Symposium on Computer Assisted Orthopaedic Surgery
, pp. 20
-
-
Gehrke, T.1
Wiese, K.2
Hahne, H.J.3
Hassenpflug, J.4
-
11
-
-
20444367428
-
First results using the ROBODOC® system for total knee replacement
-
Davos, Switzerland
-
Tenbusch, M., Lahmer, A., Wiesel, U., and Börner, M. First results using the ROBODOC® system for total knee replacement. In Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 2001, p. 133.
-
(2001)
Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery
, pp. 133
-
-
Tenbusch, M.1
Lahmer, A.2
Wiesel, U.3
Börner, M.4
-
12
-
-
0008926177
-
Experiences with the ROBODOC® system in more than 1000 cases
-
Tokyo, Japan
-
Börner, M., Lahmer, A., Bauer, A., and Stier, U. Experiences with the ROBODOC® system in more than 1000 cases. In Proceedings of the 12th International Symposium and Exhibition on Computer Assisted Radiology and Surgery, Tokyo, Japan, 1998, pp. 689-673.
-
(1998)
Proceedings of the 12th International Symposium and Exhibition on Computer Assisted Radiology and Surgery
, pp. 673-689
-
-
Börner, M.1
Lahmer, A.2
Bauer, A.3
Stier, U.4
-
13
-
-
0038008735
-
Clinical introduction of the CASPAR® system: Problems and initial results
-
Davos, Switzerland
-
Grueneis, C. O. R., Richter, R. H., and Hennig, F. F. Clinical introduction of the CASPAR® system: Problems and initial results. In Proceedings of the 4th International Symposium on Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 1999, p. 19.
-
(1999)
Proceedings of the 4th International Symposium on Computer Assisted Orthopaedic Surgery
, pp. 19
-
-
Grueneis, C.O.R.1
Richter, R.H.2
Hennig, F.F.3
-
14
-
-
0031686277
-
Medical imaging and registration in computer assisted surgery
-
Simon, D. A. and Lavallée, S. Medical imaging and registration in computer assisted surgery. Clin. Orthop. Related Res., 1998, 354, 17-27.
-
(1998)
Clin. Orthop. Related Res.
, vol.354
, pp. 17-27
-
-
Simon, D.A.1
Lavallée, S.2
-
15
-
-
20444429193
-
Development of a markerless registration method and a semi-active control strategy for robot-assisted orthopaedic surgery
-
PhD thesis, Katholieke Universiteit Leuven, Leuven, Belgium
-
Van Ham, G. Development of a markerless registration method and a semi-active control strategy for robot-assisted orthopaedic surgery. PhD thesis, Katholieke Universiteit Leuven, Leuven, Belgium, 2002.
-
(2002)
-
-
Van Ham, G.1
-
16
-
-
85009896964
-
Influence of bone milling parameters on the temperature rise milling forces and surface flatness in view of robot-assisted total knee arthroplasty
-
Berlin, Germany
-
Denis, K., Van Ham, G., Vander Sloten, J., Van Auderkercke, R., Van der Perre, G., De Schutter, J., Kruth, J.-P., Bellemans, J., and Fabry, G. Influence of bone milling parameters on the temperature rise milling forces and surface flatness in view of robot-assisted total knee arthroplasty. In Proceedings of the 15th International Congress and Exhibition on Computer Assisted Radiology and Surgery, Berlin, Germany, 2001, pp. 300-306.
-
(2001)
Proceedings of the 15th International Congress and Exhibition on Computer Assisted Radiology and Surgery
, pp. 300-306
-
-
Denis, K.1
Van Ham, G.2
Vander Sloten, J.3
Van Auderkercke, R.4
Van der Perre, G.5
De Schutter, J.6
Kruth, J.-P.7
Bellemans, J.8
Fabry, G.9
-
17
-
-
84907037949
-
Registration and immobilization in robot-assisted surgery
-
Lea, J. T., Watkins, D., Mills, A., Peshkin, M. A., Kienzle, T. C., and Stulberg, S. D. Registration and immobilization in robot-assisted surgery. J. Image Guided Surg., 1995, 1(2), 80-87.
-
(1995)
J. Image Guided Surg.
, vol.1
, Issue.2
, pp. 80-87
-
-
Lea, J.T.1
Watkins, D.2
Mills, A.3
Peshkin, M.A.4
Kienzle, T.C.5
Stulberg, S.D.6
-
18
-
-
0024065475
-
Compliant robot motion, I: A formalism for specifying compliant motion tasks
-
De Schutter, J. and Van Brussel, H. Compliant robot motion, I: A formalism for specifying compliant motion tasks. Int. J. Robotics Res., 1988, 7(4), 3-17.
-
(1988)
Int. J. Robotics Res.
, vol.7
, Issue.4
, pp. 3-17
-
-
De Schutter, J.1
Van Brussel, H.2
-
19
-
-
0030211733
-
Specification of force-controlled actions in the 'task frame formalism' - A synthesis
-
Bruyninckx, H. and De Schutter, J. Specification of force-controlled actions in the 'task frame formalism' - a synthesis. IEEE Trans, Robotics Automn, 1996, 12(4), 581-589.
-
(1996)
IEEE Trans, Robotics Automn.
, vol.12
, Issue.4
, pp. 581-589
-
-
Bruyninckx, H.1
De Schutter, J.2
-
20
-
-
0024065616
-
Compliant robot motion. II: A control approach based on external control loops
-
De Schutter, J. and Van Brussel, H. Compliant robot motion. II: A control approach based on external control loops. Int. J. Robotics Res., 1988, 7(4), 18-33.
-
(1988)
Int. J. Robotics Res.
, vol.7
, Issue.4
, pp. 18-33
-
-
De Schutter, J.1
Van Brussel, H.2
-
21
-
-
0033182984
-
Hippocrate: A safe robot arm for medical applications with force feedback
-
Pierrot, F., Dombre, E., Dégoulange, E., Urbain, L., Carron, P., Boudet, S., Gariépy, J., and Mégnien, J. L. Hippocrate: a safe robot arm for medical applications with force feedback. Med. Image Analysis, 1999, 3(3), 285-300.
-
(1999)
Med. Image Analysis
, vol.3
, Issue.3
, pp. 285-300
-
-
Pierrot, F.1
Dombre, E.2
Dégoulange, E.3
Urbain, L.4
Carron, P.5
Boudet, S.6
Gariépy, J.7
Mégnien, J.L.8
-
22
-
-
0032427065
-
Machining and accuracy studies for a tibial knee implant, using a force-controlled robot
-
Van Ham, G., Denis, K., Vander Sloten, J., Can Auderkercke, R., Van der Perre, G., De Schutter, J., Aertbeliën, E., Demey, S., and Bellemans, J. Machining and accuracy studies for a tibial knee implant, using a force-controlled robot. Computer Aided Surg., 1998, 3(3), 123-133.
-
(1998)
Computer Aided Surg.
, vol.3
, Issue.3
, pp. 123-133
-
-
Van Ham, G.1
Denis, K.2
Vander Sloten, J.3
Can Auderkercke, R.4
Van der Perre, G.5
De Schutter, J.6
Aertbeliën, E.7
Demey, S.8
Bellemans, J.9
-
24
-
-
0029063509
-
Robot-assisted knee surgery: Establishing a force control strategy incorporating active motion constraint
-
Ho, S. C., Hibberd, R. D., and Davies, B. L. Robot-assisted knee surgery: Establishing a force control strategy incorporating active motion constraint. IEEE Engng Medicine Biol. Mag., 1995, 14 (3), 292-300.
-
(1995)
IEEE Engng. Medicine Biol. Mag.
, vol.14
, Issue.3
, pp. 292-300
-
-
Ho, S.C.1
Hibberd, R.D.2
Davies, B.L.3
-
25
-
-
0037271206
-
The Acrobot® system for total knee replacement
-
Jakopec, M., Harris, S. J., Baena, F. R. y., Gomes, P., and Davies, B. L. The Acrobot® system for total knee replacement. Ind. Robot, 2003, 30(1), 61-66.
-
(2003)
Ind. Robot.
, vol.30
, Issue.1
, pp. 61-66
-
-
Jakopec, M.1
Harris, S.J.2
Baena, F.R.Y.3
Gomes, P.4
Davies, B.L.5
-
26
-
-
84974672867
-
Preliminary results of an early clinical experience with the Acrobot® system for total knee replacement surgery
-
Tokyo, Japan
-
Jakopec, M., Harris, S. J., Baena, F. R. y., Gomes, P., Cobb, J., and Davies, B. L. Preliminary results of an early clinical experience with the Acrobot® system for total knee replacement surgery. In Proceedings of the 5th International Conference on Medical Image Computing and Computer Assisted Intervention, Tokyo, Japan, 2002, pp. 256-263.
-
(2002)
Proceedings of the 5th International Conference on Medical Image Computing and Computer Assisted Intervention
, pp. 256-263
-
-
Jakopec, M.1
Harris, S.J.2
Baena, F.R.Y.3
Gomes, P.4
Cobb, J.5
Davies, B.L.6
-
27
-
-
0032081409
-
Guiding systems for computer-assisted surgery
-
Troccaz, J., Peshkin, M., and Davies, B. L. Guiding systems for computer-assisted surgery. Med. Image Analysis, 1998, 2 (2), 101-119.
-
(1998)
Med. Image Analysis
, vol.2
, Issue.2
, pp. 101-119
-
-
Troccaz, J.1
Peshkin, M.2
Davies, B.L.3
-
28
-
-
20444394864
-
Synergistic robotic assistance to cardiac procedures
-
Paris, France
-
Schneider, O., Troccaz, J., Chavanon, O., and Blin, D. Synergistic robotic assistance to cardiac procedures. In Proceedings of the 13th International Congress and Exhibition on Computer Assisted Radiology and Surgery, Paris, France, 1999, pp. 803-807.
-
(1999)
Proceedings of the 13th International Congress and Exhibition on Computer Assisted Radiology and Surgery
, pp. 803-807
-
-
Schneider, O.1
Troccaz, J.2
Chavanon, O.3
Blin, D.4
-
30
-
-
12344319441
-
An actively constrained two degree-of-freedom manipulator for passive deployment applications
-
Reedman, A. V. C. and Bouazza-Marouf, K. An actively constrained two degree-of-freedom manipulator for passive deployment applications. Proc. Instn Mech. Engrs, Part I: J. Systems and Control Engineering, 2004, 218(12), 63-74.
-
(2004)
Proc. Instn Mech. Engrs, Part I: J. Systems and Control Engineering
, vol.218
, Issue.12
, pp. 63-74
-
-
Reedman, A.V.C.1
Bouazza-Marouf, K.2
-
31
-
-
20444390760
-
Design of a robotic system to support the acetabular cup implantation in total hip replacement procedures
-
San Francisco, California, USA
-
Wahrburg, J. and Kerschbaumer, F. Design of a robotic system to support the acetabular cup implantation in total hip replacement procedures. In Proceedings of the 14th International Symposium and Exhibition on Computer Assisted Radiology and Surgery, San Francisco, California, USA, 2000, pp. 220-225.
-
(2000)
Proceedings of the 14th International Symposium and Exhibition on Computer Assisted Radiology and Surgery
, pp. 220-225
-
-
Wahrburg, J.1
Kerschbaumer, F.2
-
32
-
-
0031690023
-
Computer asisted measurement of cup placement in total hip replacement
-
Jaramaz, B., DiGioia, A. M., Blackwell, M., and Nikou, C. Computer asisted measurement of cup placement in total hip replacement. Clin. Orthop. Related Res., 1998, 354, 70-81.
-
(1998)
Clin. Orthop. Related Res.
, vol.354
, pp. 70-81
-
-
Jaramaz, B.1
Digioia, A.M.2
Blackwell, M.3
Nikou, C.4
-
33
-
-
20444426986
-
Reduction in variability of acetabular cup position using computer assisted surgery
-
San Francisco, California, USA
-
Vandervelde, D., Leenders, T., Mahieu, G., Nuyts, R., and Verstreken, J. Reduction in variability of acetabular cup position using computer assisted surgery. In Proceedings of the 14th International Symposium and Exhibition on Computer Assisted Radiology and Surgery, San Francisco, California, USA, 2000, pp. 231-255.
-
(2000)
Proceedings of the 14th International Symposium and Exhibition on Computer Assisted Radiology and Surgery
, pp. 231-255
-
-
Vandervelde, D.1
Leenders, T.2
Mahieu, G.3
Nuyts, R.4
Verstreken, J.5
-
34
-
-
20444368571
-
Clinical measurements of acetabular component orientation using surgical navigation technologies
-
Davos, Switzerland
-
DiGioia, A. M., Moody, J. E., LaBarca, R. S., Nikou, C., and Jaramaz, B. Clinical measurements of acetabular component orientation using surgical navigation technologies. In Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, Davos, Switzerland, 2001, p. 19.
-
(2001)
Proceedings of the 1st Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery
, pp. 19
-
-
Digioia, A.M.1
Moody, J.E.2
Labarca, R.S.3
Nikou, C.4
Jaramaz, B.5
|