메뉴 건너뛰기




Volumn 17, Issue 3, 2003, Pages 287-288

A view of and through double-lumen tubes

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA COMPLICATION; ANESTHESIOLOGICAL TECHNIQUES; AUSCULTATION; CLINICAL PRACTICE; DOUBLE LUMEN TUBE; EDITORIAL; ENDOTRACHEAL TUBE; FIBEROPTIC BRONCHOSCOPY; HUMAN; MEDICOLEGAL ASPECT; PATIENT POSITIONING; PRACTICE GUIDELINE; PRIORITY JOURNAL;

EID: 0038461038     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(03)00058-2     Document Type: Editorial
Times cited : (44)

References (11)
  • 1
    • 0037628935 scopus 로고    scopus 로고
    • Left double-lumen tubes - Clinical experience with 1,170 patients
    • Brodsky JB, Lemmens HJM: Left double-lumen tubes - Clinical experience with 1,170 patients. J Cardiothorac Vasc Anesth 17:289-298, 2003
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 289-298
    • Brodsky, J.B.1    Lemmens, H.J.M.2
  • 2
    • 0020120153 scopus 로고
    • One-lung anesthesia for pediatric thoracic surgery: A new use for the fiberoptic bronchoscope
    • Watson CB, Bowe EA, Burk W: One-lung anesthesia for pediatric thoracic surgery: a new use for the fiberoptic bronchoscope. Anesthesiology 56:314-315, 1982
    • (1982) Anesthesiology , vol.56 , pp. 314-315
    • Watson, C.B.1    Bowe, E.A.2    Burk, W.3
  • 3
    • 0027494519 scopus 로고
    • The position of double-lumen tubes should be routinely determined by fiberoptic bronchoscopy
    • Benumof J: The position of double-lumen tubes should be routinely determined by fiberoptic bronchoscopy. J Cardiothorac Vasc Anesth 7:513-514, 1993
    • (1993) J Cardiothorac Vasc Anesth , vol.7 , pp. 513-514
    • Benumof, J.1
  • 4
    • 0002362639 scopus 로고    scopus 로고
    • Management of patients undergoing oesophagectomy
    • Gray AJG, Hoile RW, Ingram GS, et al (eds). London: The Report of the National Confidential Enquiry Into Perioperative Deaths
    • Sherry K: Management of patients undergoing oesophagectomy. In: Gray AJG, Hoile RW, Ingram GS, et al (eds): The report of the national confidential enquiry into perioperative deaths 1996/1997. London: The Report of the National Confidential Enquiry Into Perioperative Deaths. 1998, pp 57-61
    • (1998) The Report of the National Confidential Enquiry Into Perioperative Deaths 1996/1997 , pp. 57-61
    • Sherry, K.1
  • 5
    • 0033625252 scopus 로고    scopus 로고
    • Placement of double-lumen tubes - Time to shed light on an old problem
    • Pennefather SH, Russell GN: Placement of double-lumen tubes - Time to shed light on an old problem. Br J Anaesth 83:308-310, 2000
    • (2000) Br J Anaesth , vol.83 , pp. 308-310
    • Pennefather, S.H.1    Russell, G.N.2
  • 6
    • 0027424342 scopus 로고
    • The resting volume and compliance characteristics of the bronchial cuff of left polyvinylchloride double-lumen endobronchial tubes
    • Hanallah MS, Benumof JL, Bachenmier LC, et al: The resting volume and compliance characteristics of the bronchial cuff of left polyvinylchloride double-lumen endobronchial tubes. Anesth Analg 77:1222-1226, 1993
    • (1993) Anesth Analg , vol.77 , pp. 1222-1226
    • Hanallah, M.S.1    Benumof, J.L.2    Bachenmier, L.C.3
  • 7
    • 0027240358 scopus 로고
    • A clinical comparison of bronchial cuff pressures in three different designs of left double-lumen tubes
    • Slinger PD, Chripko D: A clinical comparison of bronchial cuff pressures in three different designs of left double-lumen tubes. Anesth Analg 77:305-308, 1993
    • (1993) Anesth Analg , vol.77 , pp. 305-308
    • Slinger, P.D.1    Chripko, D.2
  • 8
    • 0031807844 scopus 로고    scopus 로고
    • Predicting the size of double-lumen tube based on tracheal diameter
    • Chow MYH, Liam BL, Lew TWK: Predicting the size of double-lumen tube based on tracheal diameter. Anesth Analg 87:158-160, 1998
    • (1998) Anesth Analg , vol.87 , pp. 158-160
    • Chow, M.Y.H.1    Liam, B.L.2    Lew, T.W.K.3
  • 9
    • 0031003952 scopus 로고    scopus 로고
    • Evaluation of an approach to choosing a left double-lumen tube based on chest computed tomographic scan measurement of the left mainstem bronchial diameter
    • Hanallah MS, Benumof JL, Silverman PM, et al: Evaluation of an approach to choosing a left double-lumen tube based on chest computed tomographic scan measurement of the left mainstem bronchial diameter. J Cardiothorac Vasc Anesth 11:168-171, 1997
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 168-171
    • Hanallah, M.S.1    Benumof, J.L.2    Silverman, P.M.3
  • 10
    • 0037937984 scopus 로고    scopus 로고
    • Anesthetic management for surgery of the lungs and mediastinum
    • Hensley FA (ed). Philadelphia, PA, Lippincott
    • Slinger P, Sullivan EA: Anesthetic management for surgery of the lungs and mediastinum. In: Hensley FA (ed): A Practical Approach to Cardiac Anesthesia (ed 3). Philadelphia, PA, Lippincott, 2003, p 658
    • (2003) A Practical Approach to Cardiac Anesthesia (Ed 3) , pp. 658
    • Slinger, P.1    Sullivan, E.A.2
  • 11
    • 0034100138 scopus 로고    scopus 로고
    • The incidence of right upper lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery
    • Campos JH, Massa FC, Kernstine KH: The incidence of right upper lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery. Anesth Analg 90:535-540, 2000
    • (2000) Anesth Analg , vol.90 , pp. 535-540
    • Campos, J.H.1    Massa, F.C.2    Kernstine, K.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.