Volumn 39, Issue 5, 2004, Pages 271-276

Amorphous Silicon, Flat-Panel, X-ray Detector: Reliability of Digital Image Fusion Regarding Angle and Distance Measurements in Long-Leg Radiography

Author keywords

Digital radiography; Flat panel detector; Image composition; Long leg radiography

Indexed keywords

CESIUM; CESIUM IODIDE; IODINE DERIVATIVE; SILICON; UNCLASSIFIED DRUG;

EID: 1942437012     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000117853.02516.01     Document Type: Article
Times cited : (7)

References (16)
  • 1
    • 0031805838 scopus 로고    scopus 로고
    • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology
    • Siewerdsen JH, Antonuk LE, El Mohri Y, et al. Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology. Med Phys. 1998;25:614-628.
    • (1998) Med Phys , vol.25 , pp. 614-628
    • Siewerdsen, J.H.1    Antonuk, L.E.2    El Mohri, Y.3
  • 2
    • 0036830190 scopus 로고    scopus 로고
    • Flat panel digital radiography compared with storage phosphor computed radiography: Assessment of dose versus image quality in phantom studies
    • Fischbach F, Ricke J, Freund T, et al. Flat panel digital radiography compared with storage phosphor computed radiography: assessment of dose versus image quality in phantom studies. Invest Radiol. 2002;37:609-614.
    • (2002) Invest Radiol , vol.37 , pp. 609-614
    • Fischbach, F.1    Ricke, J.2    Freund, T.3
  • 3
    • 0037382624 scopus 로고    scopus 로고
    • Amorphous silicon, flat-panel, x-ray detector versus storage phosphor-based computed radiography: Contrast-detail phantom study at different tube voltages and detector entrance doses
    • Hamer OW, Völk M, Zorger Z, et al. Amorphous silicon, flat-panel, x-ray detector versus storage phosphor-based computed radiography: contrast-detail phantom study at different tube voltages and detector entrance doses. Invest Radiol. 2003;38:212-220.
    • (2003) Invest Radiol , vol.38 , pp. 212-220
    • Hamer, O.W.1    Völk, M.2    Zorger, Z.3
  • 4
    • 0141853098 scopus 로고    scopus 로고
    • Lumbar spine radiography: Digital flat-panel detector versus screen-film and storage-phosphor systems in monkeys as a pediatric model
    • Ludwig K, Ahlers K, Wormanns D, et al. Lumbar spine radiography: digital flat-panel detector versus screen-film and storage-phosphor systems in monkeys as a pediatric model. Radiology. 2003;229:140-144.
    • (2003) Radiology , vol.229 , pp. 140-144
    • Ludwig, K.1    Ahlers, K.2    Wormanns, D.3
  • 5
    • 0141855190 scopus 로고    scopus 로고
    • Dose reduction in patients undergoing chest imaging: Digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography
    • Bacher K, Smeets P, Bonnarens K, et al. Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography. AJR Am J Roentgenol. 2003;181:923-929.
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 923-929
    • Bacher, K.1    Smeets, P.2    Bonnarens, K.3
  • 6
    • 0242585291 scopus 로고    scopus 로고
    • Flat-panel x-ray detector based on amorphous silicon versus asymmetric screen-film system: Phantom study of dose reduction and depiction of simulated findings
    • Rapp-Bernhardt U, Roehl FW, Gibbs RC, et al. Flat-panel x-ray detector based on amorphous silicon versus asymmetric screen-film system: phantom study of dose reduction and depiction of simulated findings. Radiology. 2003;227:484-492.
    • (2003) Radiology , vol.227 , pp. 484-492
    • Rapp-Bernhardt, U.1    Roehl, F.W.2    Gibbs, R.C.3
  • 7
    • 0346665619 scopus 로고    scopus 로고
    • Routine skeleton radiography using a flat-panel detector: Image quality and clinical acceptance at 50% dose reduction
    • Völk M, Paetzel C, Angele P, et al. Routine skeleton radiography using a flat-panel detector: image quality and clinical acceptance at 50% dose reduction. Invest Radiol. 2003;38:230-235.
    • (2003) Invest Radiol , vol.38 , pp. 230-235
    • Völk, M.1    Paetzel, C.2    Angele, P.3
  • 8
    • 0037973621 scopus 로고    scopus 로고
    • Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography
    • Ganten M, Radeleff B, Kampschulte A, et al. Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography. AJR Am J Roentgenol. 2003;181:171-176.
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 171-176
    • Ganten, M.1    Radeleff, B.2    Kampschulte, A.3
  • 9
    • 0031975442 scopus 로고    scopus 로고
    • Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography: Effect of dose reduction on the detectability of cortical bone defects and fractures
    • Strotzer M, Gmeinwieser J, Spahn M, et al. Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography: effect of dose reduction on the detectability of cortical bone defects and fractures. Invest Radiol. 1998;33:33-38.
    • (1998) Invest Radiol , vol.33 , pp. 33-38
    • Strotzer, M.1    Gmeinwieser, J.2    Spahn, M.3
  • 10
    • 0347296040 scopus 로고    scopus 로고
    • Digital image composition in long-leg radiography with a flat-panel detector: First clinical experiences
    • Völk M, Angele P, Hamer O, et al. Digital image composition in long-leg radiography with a flat-panel detector: first clinical experiences. Invest Radiol. 2003;38:189-192.
    • (2003) Invest Radiol , vol.38 , pp. 189-192
    • Völk, M.1    Angele, P.2    Hamer, O.3
  • 11
    • 0034051282 scopus 로고    scopus 로고
    • Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    • Spahn M, Strotzer M, Volk M, et al. Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system. Invest Radiol. 2000;35:260-266.
    • (2000) Invest Radiol , vol.35 , pp. 260-266
    • Spahn, M.1    Strotzer, M.2    Volk, M.3
  • 12
    • 0003107268 scopus 로고    scopus 로고
    • Automatic mosaic and display from a sequence of peripheral angiographic images
    • Chou J-S, Qian J, Wu Z, et al. Automatic mosaic and display from a sequence of peripheral angiographic images. Proc SPIE. 1997;3034:1077-1087.
    • (1997) Proc SPIE , vol.3034 , pp. 1077-1087
    • Chou, J.-S.1    Qian, J.2    Wu, Z.3
  • 13
    • 0035140249 scopus 로고    scopus 로고
    • Digital radiography of scoliosis with a scanning method: Initial evaluation
    • Geijer H, Beckman K, Jonsson B, et al. Digital radiography of scoliosis with a scanning method: initial evaluation. Radiology. 2001;218:402-410.
    • (2001) Radiology , vol.218 , pp. 402-410
    • Geijer, H.1    Beckman, K.2    Jonsson, B.3
  • 14
    • 19044400134 scopus 로고    scopus 로고
    • Scoliosis evaluation by direct digital radiography and computerized post-processing
    • Berliner L, Kreang-Arekul S, Kaufman L. Scoliosis evaluation by direct digital radiography and computerized post-processing. J Digit Imaging. 2002;15(suppl 1):270-274.
    • (2002) J Digit Imaging , vol.15 , Issue.SUPPL. 1 , pp. 270-274
    • Berliner, L.1    Kreang-Arekul, S.2    Kaufman, L.3
  • 15
    • 0032593893 scopus 로고    scopus 로고
    • Full-leg/full-spine image stitching: A new and accurate CR-based imaging technique
    • Dewaele P, Vuylsteke P, Van de Velde S, et al. Full-leg/full-spine image stitching: a new and accurate CR-based imaging technique. Proc SPIE. 1999;3661:131-138.
    • (1999) Proc SPIE , vol.3661 , pp. 131-138
    • Dewaele, P.1    Vuylsteke, P.2    Van De Velde, S.3
  • 16
    • 0036781512 scopus 로고    scopus 로고
    • Digital radiography with large-area flat-panel detectors
    • Kotter E, Langer M. Digital radiography with large-area flat-panel detectors. Eur Radiol. 2002;12:2562-2570.
    • (2002) Eur Radiol , vol.12 , pp. 2562-2570
    • Kotter, E.1    Langer, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.