메뉴 건너뛰기




Volumn 32, Issue 2, 2005, Pages 245-254

Assessment of the fetus: Intermittent auscultation, electronic fetal heart rate tracing, and fetal pulse oximetry

Author keywords

[No Author keywords available]

Indexed keywords

FETUS ELECTROCARDIOGRAPHY; FETUS HEART RATE; FETUS HYPOXIA; FETUS MONITORING; HEART AUSCULTATION; HUMAN; LONG TERM CARE; MORBIDITY; OUTCOMES RESEARCH; PRIORITY JOURNAL; PULSE OXIMETRY; REVIEW;

EID: 19344364343     PISSN: 08898545     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ogc.2004.12.003     Document Type: Review
Times cited : (7)

References (30)
  • 1
    • 0041837230 scopus 로고    scopus 로고
    • Electronic fetal heart rate monitoring: A story of survival
    • J.T. Parer Electronic fetal heart rate monitoring: a story of survival Obstet Gynecol Surv 58 2003 561 563
    • (2003) Obstet Gynecol Surv , vol.58 , pp. 561-563
    • Parer, J.T.1
  • 2
    • 0035195304 scopus 로고    scopus 로고
    • Historical controversy in health technology assessment: The case of electronic fetal monitoring
    • D.H. Banta, and S.B. Thacker Historical controversy in health technology assessment: the case of electronic fetal monitoring Obstet Gynecol Surv 56 11 2001 707 719
    • (2001) Obstet Gynecol Surv , vol.56 , Issue.11 , pp. 707-719
    • Banta, D.H.1    Thacker, S.B.2
  • 3
    • 37449033033 scopus 로고
    • Fetal heart rate patterns: Monitoring, interpretation, and management
    • American College of Obstetricians and Gynecologists
    • American College of Obstetricians and Gynecologists Fetal heart rate patterns: monitoring, interpretation, and management American College of Obstetrics and Gynecology Technical Bulletin 207 1995 182 189
    • (1995) American College of Obstetrics and Gynecology Technical Bulletin , vol.207 , pp. 182-189
  • 4
    • 0036804779 scopus 로고    scopus 로고
    • Problems with intrapartum fetal heart rate monitoring interpretation and management
    • R.K. Freeman Problems with intrapartum fetal heart rate monitoring interpretation and management Obstet Gynecol 100 2002 813 826
    • (2002) Obstet Gynecol , vol.100 , pp. 813-826
    • Freeman, R.K.1
  • 5
    • 0035897924 scopus 로고    scopus 로고
    • Randomised controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk obstetric population
    • G. Mires, F. Williams, and P. Howie Randomised controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk obstetric population BMJ 322 2001 1457 1460
    • (2001) BMJ , vol.322 , pp. 1457-1460
    • Mires, G.1    Williams, F.2    Howie, P.3
  • 6
    • 0035897930 scopus 로고    scopus 로고
    • Electronic fetal monitoring is not necessary for low risk labours
    • R. Goddard Electronic fetal monitoring is not necessary for low risk labours BMJ 322 2001 1436 1437
    • (2001) BMJ , vol.322 , pp. 1436-1437
    • Goddard, R.1
  • 8
    • 0035222923 scopus 로고    scopus 로고
    • Continuous electronic heart rate monitoring for fetal assessment during labor
    • S.B. Thacker, D. Stroup, and M. Chang Continuous electronic heart rate monitoring for fetal assessment during labor Cochrane Database Syst Rev CD000063 2001
    • (2001) Cochrane Database Syst Rev
    • Thacker, S.B.1    Stroup, D.2    Chang, M.3
  • 9
    • 14244259974 scopus 로고    scopus 로고
    • Fetal electrocardiogram (ECG) for fetal monitoring in labour
    • J.P. Neilson Fetal electrocardiogram (ECG) for fetal monitoring in labour Cochrane Database Syst Rev CD000116 2003
    • (2003) Cochrane Database Syst Rev
    • Neilson, J.P.1
  • 10
    • 0030070405 scopus 로고    scopus 로고
    • Uncertain value of fetal heart rate monitoring in predicting cerebral palsy
    • K.B. Nelson, J.M. Dambrosia, and T.Y. Ting Uncertain value of fetal heart rate monitoring in predicting cerebral palsy N Engl J Med 334 1996 613 618
    • (1996) N Engl J Med , vol.334 , pp. 613-618
    • Nelson, K.B.1    Dambrosia, J.M.2    Ting, T.Y.3
  • 11
    • 0035082212 scopus 로고    scopus 로고
    • The prediction and prevention of intrapartum fetal asphyxia in term pregnancies
    • J.A. Low, H. Pickersgill, and H. Killen The prediction and prevention of intrapartum fetal asphyxia in term pregnancies Am J Obstet Gynecol 184 2001 724 730
    • (2001) Am J Obstet Gynecol , vol.184 , pp. 724-730
    • Low, J.A.1    Pickersgill, H.2    Killen, H.3
  • 12
    • 0034991123 scopus 로고    scopus 로고
    • Evaluation of fetal heart monitoring in the first stage of labor
    • T. Stefos, A. Sortiriadis, and P. Tsikas Evaluation of fetal heart monitoring in the first stage of labor J Matern Fetal Med 10 2001 48 51
    • (2001) J Matern Fetal Med , vol.10 , pp. 48-51
    • Stefos, T.1    Sortiriadis, A.2    Tsikas, P.3
  • 13
    • 0742269644 scopus 로고    scopus 로고
    • Unselected low-risk pregnancies and the effect of continuous intrapartum fetal heart rate monitoring on umbilical blood gases and cerebral palsy
    • H. Sameshima, T. Ikenoue, and T. Ikeda Unselected low-risk pregnancies and the effect of continuous intrapartum fetal heart rate monitoring on umbilical blood gases and cerebral palsy Am J Obstet Gynecol 190 2004 118 123
    • (2004) Am J Obstet Gynecol , vol.190 , pp. 118-123
    • Sameshima, H.1    Ikenoue, T.2    Ikeda, T.3
  • 14
    • 0034928780 scopus 로고    scopus 로고
    • Computerised analysis of the fetal heart rate and relation to acidaemia at delivery
    • B.K. Strachan, D.S. Sahota, and W.J. van Wijngaarden Computerised analysis of the fetal heart rate and relation to acidaemia at delivery Br J Obstet Gynaecol 108 2001 848 852
    • (2001) Br J Obstet Gynaecol , vol.108 , pp. 848-852
    • Strachan, B.K.1    Sahota, D.S.2    Van Wijngaarden, W.J.3
  • 15
    • 0033836379 scopus 로고    scopus 로고
    • A comparison of visual analyses of intrapartum fetal heart rate tracings according to the new National Institute of Child Health and Human Development guidelines with computer analyses by an automated fetal heart rate monitoring system
    • L. Devoe, S. Golde, and Y. Kilman A comparison of visual analyses of intrapartum fetal heart rate tracings according to the new National Institute of Child Health and Human Development guidelines with computer analyses by an automated fetal heart rate monitoring system Am J Obstet Gynecol 183 2000 361 366
    • (2000) Am J Obstet Gynecol , vol.183 , pp. 361-366
    • Devoe, L.1    Golde, S.2    Kilman, Y.3
  • 16
    • 0036142986 scopus 로고    scopus 로고
    • Intrapartum fetal stimulation tests: A meta-analysis
    • D.W. Skupski, C.R. Rosenberg, and G.S. Eglinton Intrapartum fetal stimulation tests: a meta-analysis Obstet Gynecol 99 2002 129 134
    • (2002) Obstet Gynecol , vol.99 , pp. 129-134
    • Skupski, D.W.1    Rosenberg, C.R.2    Eglinton, G.S.3
  • 17
    • 0028238652 scopus 로고
    • Elimination of fetal scalp blood sampling on a large clinical service
    • T.M. Goodwin, L. Milner-Masterson, and R. Paul Elimination of fetal scalp blood sampling on a large clinical service Obstet Gynecol 83 1994 971 974
    • (1994) Obstet Gynecol , vol.83 , pp. 971-974
    • Goodwin, T.M.1    Milner-Masterson, L.2    Paul, R.3
  • 18
    • 0034607021 scopus 로고    scopus 로고
    • Fetal ECG time-interval analysis did not reduce operative interventions compared to cardiotocography alone
    • B.K. Strachan, W.J. van Wijngaarden, and D. Sahota Fetal ECG time-interval analysis did not reduce operative interventions compared to cardiotocography alone Lancet 355 2000 456 459
    • (2000) Lancet , vol.355 , pp. 456-459
    • Strachan, B.K.1    Van Wijngaarden, W.J.2    Sahota, D.3
  • 19
    • 0035908749 scopus 로고    scopus 로고
    • Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: A Swedish randomised controlled trial
    • I. Amer-Wahlin, C. Hellsten, and H. Noren Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial Lancet 358 2002 534 538
    • (2002) Lancet , vol.358 , pp. 534-538
    • Amer-Wahlin, I.1    Hellsten, C.2    Noren, H.3
  • 20
    • 0037249236 scopus 로고    scopus 로고
    • Fetal electrocardiography in labor and neonatal outcome: Data from the Swedish randomized controlled trial on intrapartum fetal monitoring
    • H. Noren, I. Amer-Wahlin, and H. Hagberg Fetal electrocardiography in labor and neonatal outcome: data from the Swedish randomized controlled trial on intrapartum fetal monitoring Am J Obstet Gynecol 188 2003 183 192
    • (2003) Am J Obstet Gynecol , vol.188 , pp. 183-192
    • Noren, H.1    Amer-Wahlin, I.2    Hagberg, H.3
  • 21
    • 0034054383 scopus 로고    scopus 로고
    • Intrapartum fetal pulse oximetry: Part 1. Principles and technical issues: Part 2. Clinical application
    • J. Yam, S. Chua, and S. Arulkumaran Intrapartum fetal pulse oximetry: Part 1. Principles and technical issues: Part 2. Clinical application Obstet Gynecol Surv 55 2000 163 183
    • (2000) Obstet Gynecol Surv , vol.55 , pp. 163-183
    • Yam, J.1    Chua, S.2    Arulkumaran, S.3
  • 22
    • 0030834794 scopus 로고    scopus 로고
    • Multicenter study on the clinical value of fetal pulse oximetry: The French Study Group on Fetal Pulse Oximetry
    • F. Goffinet, B. Langer, and B. Carbonne Multicenter study on the clinical value of fetal pulse oximetry: the French Study Group on Fetal Pulse Oximetry Am J Obstet Gynecol 177 1997 1238 1246
    • (1997) Am J Obstet Gynecol , vol.177 , pp. 1238-1246
    • Goffinet, F.1    Langer, B.2    Carbonne, B.3
  • 23
    • 0028938140 scopus 로고
    • Arterial oxygen saturation in relation to metabolic acidosis in fetal lambs
    • R. Nijland, H.W. Jongsma, and J.G. Nihuis Arterial oxygen saturation in relation to metabolic acidosis in fetal lambs Am J Obstet Gynecol 172 1995 810 819
    • (1995) Am J Obstet Gynecol , vol.172 , pp. 810-819
    • Nijland, R.1    Jongsma, H.W.2    Nihuis, J.G.3
  • 24
    • 0033036109 scopus 로고    scopus 로고
    • Fetal pulse oximetry: Duration of desaturation and intrapartum outcomes
    • S.L. Bloom, R.G. Swindle, and D.D. McIntire Fetal pulse oximetry: duration of desaturation and intrapartum outcomes Obstet Gynecol 93 1999 1036 1040
    • (1999) Obstet Gynecol , vol.93 , pp. 1036-1040
    • Bloom, S.L.1    Swindle, R.G.2    McIntire, D.D.3
  • 25
    • 0030963857 scopus 로고    scopus 로고
    • The safety of fetal pulse oximetry in parturients requiring fetal scalp sampling
    • A.K. Luttkus, W. Friedman, and S. Thomas The safety of fetal pulse oximetry in parturients requiring fetal scalp sampling Obstet Gynecol 90 1997 533 537
    • (1997) Obstet Gynecol , vol.90 , pp. 533-537
    • Luttkus, A.K.1    Friedman, W.2    Thomas, S.3
  • 26
    • 0033676537 scopus 로고    scopus 로고
    • A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns
    • T.J. Garite, G.A. Dildy, and H. McNamara A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns Am J Obstet Gynecol 183 2000 1049 1058
    • (2000) Am J Obstet Gynecol , vol.183 , pp. 1049-1058
    • Garite, T.J.1    Dildy, G.A.2    McNamara, H.3
  • 27
    • 0035988739 scopus 로고    scopus 로고
    • Is the correlation between fetal oxygen saturation and blood pH sufficient for the use of fetal pulse oximetry?
    • R.J.P. Rijnders, B.W.J. Mol, and P.J.H.M. Reuwer Is the correlation between fetal oxygen saturation and blood pH sufficient for the use of fetal pulse oximetry? J Matern Fetal Neonatal Med 11 2002 80 83
    • (2002) J Matern Fetal Neonatal Med , vol.11 , pp. 80-83
    • Rijnders, R.J.P.1    Mol, B.W.J.2    Reuwer, P.J.H.M.3
  • 28
    • 0033857020 scopus 로고    scopus 로고
    • Clinical usefulness of pulse oximetery on the fetus with non-reassuring fetal heart rate pattern?
    • S. Schmidt, S. Koslowski, and F. Sierra Clinical usefulness of pulse oximetery on the fetus with non-reassuring fetal heart rate pattern? J Perinat Med 28 2000 298 305
    • (2000) J Perinat Med , vol.28 , pp. 298-305
    • Schmidt, S.1    Koslowski, S.2    Sierra, F.3
  • 29
    • 0034830729 scopus 로고    scopus 로고
    • Fetal pulse oximetry: ACOG Committee opinion No. 258
    • American College of Obstetricians and Gynecologists
    • American College of Obstetricians and Gynecologists Fetal pulse oximetry: ACOG Committee opinion No. 258 Obstet Gynecol 98 2001 523 524
    • (2001) Obstet Gynecol , vol.98 , pp. 523-524
  • 30
    • 0038677098 scopus 로고    scopus 로고
    • Obstetric technologies: What determines clinical acceptance or rejection of results of randomized controlled trials?
    • J.T. Parer Obstetric technologies: what determines clinical acceptance or rejection of results of randomized controlled trials? Am J Obstet Gynecol 188 2003 1622 1628
    • (2003) Am J Obstet Gynecol , vol.188 , pp. 1622-1628
    • Parer, J.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.