메뉴 건너뛰기




Volumn 28, Issue 5, 2005, Pages 434-443

Alternative energy sources for the ablation of arrhythmias

Author keywords

[No Author keywords available]

Indexed keywords

ALTERNATIVE ENERGY; BETA RADIATION; CATHETER ABLATION; ELECTROMAGNETIC RADIATION; ENERGY RESOURCE; EPICARDIUM; HEART ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; LASER; MICROWAVE RADIATION; NONHUMAN; RADIOFREQUENCY ABLATION; REVIEW; SUPRAVENTRICULAR TACHYCARDIA; ULTRASOUND;

EID: 18844416857     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2005.09481.x     Document Type: Review
Times cited : (44)

References (53)
  • 1
    • 0025870671 scopus 로고
    • Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current
    • Jackman WM, Wang XZ, Friday KJ, et al. Catheter ablation of accessory atrioventricular pathways (Wolff-Parkinson-White syndrome) by radiofrequency current. N Engl J Med 1991; 324:1605-1611.
    • (1991) N Engl J Med , vol.324 , pp. 1605-1611
    • Jackman, W.M.1    Wang, X.Z.2    Friday, K.J.3
  • 2
    • 0026776722 scopus 로고
    • Treatment of supraventricular tachycardia due to atrioventricular nodal reentry, by radiofrequency catheter ablation of slow-pathway conduction
    • Jackman WM, Beckman KJ, McClelland JH, et al. Treatment of supraventricular tachycardia due to atrioventricular nodal reentry, by radiofrequency catheter ablation of slow-pathway conduction. N Engl J Med 1992; 327:313-318.
    • (1992) N Engl J Med , vol.327 , pp. 313-318
    • Jackman, W.M.1    Beckman, K.J.2    McClelland, J.H.3
  • 3
    • 0032935092 scopus 로고    scopus 로고
    • Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial
    • The Atakr Multicenter Investigators Group
    • Calkins H, Yong P, Miller JM, et al. Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial. The Atakr Multicenter Investigators Group. Circulation 1999; 99:262-270.
    • (1999) Circulation , vol.99 , pp. 262-270
    • Calkins, H.1    Yong, P.2    Miller, J.M.3
  • 4
    • 0032959646 scopus 로고    scopus 로고
    • Thromboembolic complications of cardiac radiofrequency catheter ablation: A review of the reported incidence, pathogenesis and current research directions
    • Zhou L, Keane D, Reed G, Ruskin J. Thromboembolic complications of cardiac radiofrequency catheter ablation: A review of the reported incidence, pathogenesis and current research directions. J Cardiovasc Electrophysiol 1999; 10:611-620.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 611-620
    • Zhou, L.1    Keane, D.2    Reed, G.3    Ruskin, J.4
  • 5
    • 0036963886 scopus 로고    scopus 로고
    • New catheter ablation techniques for the treatment of cardiac arrhythmias
    • Keane D. New catheter ablation techniques for the treatment of cardiac arrhythmias. Card Electrophysiol Rev 2002; 6:341-348.
    • (2002) Card Electrophysiol Rev , vol.6 , pp. 341-348
    • Keane, D.1
  • 6
    • 0036134236 scopus 로고    scopus 로고
    • Modeling bipolar phase-shifted multielectrode catheter ablation
    • Tungjitkusolmun S, Haemmerich D, Cao H, et al. Modeling bipolar phase-shifted multielectrode catheter ablation. IEEE Trans Biomed Eng 2002; 49:10-17.
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 10-17
    • Tungjitkusolmun, S.1    Haemmerich, D.2    Cao, H.3
  • 7
    • 0031895674 scopus 로고    scopus 로고
    • Temperature-controlled irrigated tip radiofrequency catheter ablation: Comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate
    • Petersen HH, Chen X, Pietersen A, Svendsen JH, Haunso S. Temperature-controlled irrigated tip radiofrequency catheter ablation: Comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate. J Cardiovasc Electrophysiol 1998; 9:409-414.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 409-414
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunso, S.5
  • 8
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation
    • Petersen HH, Chen X, Pietersen A, Svendsen JH, Haunso S. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation. PACE 2000; 23:8-17.
    • (2000) PACE , vol.23 , pp. 8-17
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3    Svendsen, J.H.4    Haunso, S.5
  • 9
    • 0034077896 scopus 로고    scopus 로고
    • Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy: Results of a prospective multicenter study
    • Cooled RF Multi Center Investigators Group
    • Calkins H, Epstein A, Packer D, et al. Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy: Results of a prospective multicenter study. Cooled RF Multi Center Investigators Group. J Am Coll Cardiol 2000; 35:1905-1914.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1905-1914
    • Calkins, H.1    Epstein, A.2    Packer, D.3
  • 10
    • 0038608975 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation: Different cooled and noncooled electrode systems induce specific lesion geometries and adverse effects profiles
    • Dorwarth U, Fiek M, Remp T, et al. Radiofrequency catheter ablation: Different cooled and noncooled electrode systems induce specific lesion geometries and adverse effects profiles. PACE 2003; 26:1438-1445.
    • (2003) PACE , vol.26 , pp. 1438-1445
    • Dorwarth, U.1    Fiek, M.2    Remp, T.3
  • 11
    • 0037251506 scopus 로고    scopus 로고
    • Microwave, irrigated, pulsed, or conventional radiofrequency energy source: Which energy source for which catheter ablation?
    • Erdogan A, Grumbrecht S, Neumann T, Neuzner J, Pitschner HF. Microwave, irrigated, pulsed, or conventional radiofrequency energy source: Which energy source for which catheter ablation? PACE 2003; 26:504-506.
    • (2003) PACE , vol.26 , pp. 504-506
    • Erdogan, A.1    Grumbrecht, S.2    Neumann, T.3    Neuzner, J.4    Pitschner, H.F.5
  • 12
    • 0028209986 scopus 로고
    • Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury
    • Whayne JG, Nath S, Haines DE. Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury. Circulation 1994; 89:2390-2395.
    • (1994) Circulation , vol.89 , pp. 2390-2395
    • Whayne, J.G.1    Nath, S.2    Haines, D.E.3
  • 13
  • 14
    • 0029088427 scopus 로고
    • Application of ultrasound energy for intracardiac ablation of arrhythmias
    • He DS, Zimmer JE, Hynynen K, et al. Application of ultrasound energy for intracardiac ablation of arrhythmias. Eur Heart J 1995; 16:961-966.
    • (1995) Eur Heart J , vol.16 , pp. 961-966
    • He, D.S.1    Zimmer, J.E.2    Hynynen, K.3
  • 15
    • 0034680347 scopus 로고    scopus 로고
    • First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation
    • Natale A, Pisano E, Shewchik J, et al. First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation. Circulation 2000; 102:1879-1882.
    • (2000) Circulation , vol.102 , pp. 1879-1882
    • Natale, A.1    Pisano, E.2    Shewchik, J.3
  • 16
    • 0036776109 scopus 로고    scopus 로고
    • Circumferential ultrasound ablation for pulmonary vein isolation: Analysis of acute and chronic failures
    • Saliba W, Wilber D, Packer D, et al. Circumferential ultrasound ablation for pulmonary vein isolation: Analysis of acute and chronic failures. J Cardiovasc Electrophysiol 2002; 13:957-961.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 957-961
    • Saliba, W.1    Wilber, D.2    Packer, D.3
  • 17
    • 0141653928 scopus 로고    scopus 로고
    • Percutaneous pericardial instrumentation for endo-epicardial mapping of previously failed ablations
    • Schweikert RA, Saliba WI, Tomassoni G, et al. Percutaneous pericardial instrumentation for endo-epicardial mapping of previously failed ablations. Circulation 2003; 108:1329-1335.
    • (2003) Circulation , vol.108 , pp. 1329-1335
    • Schweikert, R.A.1    Saliba, W.I.2    Tomassoni, G.3
  • 18
    • 2442417983 scopus 로고    scopus 로고
    • Endocardial and epicardial radiofrequency ablation of ventricular tachycardia associated with dilated cardiomyopathy: The importance of low voltage scars
    • Soejima K, Stevenson W, Sapp J, Selwyn A, Couper G, Epstein L. Endocardial and epicardial radiofrequency ablation of ventricular tachycardia associated with dilated cardiomyopathy: The importance of low voltage scars. J Am Coll Cardiol 2004; 43:1834-1842.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1834-1842
    • Soejima, K.1    Stevenson, W.2    Sapp, J.3    Selwyn, A.4    Couper, G.5    Epstein, L.6
  • 19
    • 0021963444 scopus 로고
    • Transcatheter ablation: Comparison between laser photoablation and electrode shock ablation in the dog
    • Lee BI, Gottdiener JS, Fletcher RD, Rodriguez ER, Ferrans VJ. Transcatheter ablation: Comparison between laser photoablation and electrode shock ablation in the dog. Circulation 1985; 71:579-586.
    • (1985) Circulation , vol.71 , pp. 579-586
    • Lee, B.I.1    Gottdiener, J.S.2    Fletcher, R.D.3    Rodriguez, E.R.4    Ferrans, V.J.5
  • 20
    • 0024331133 scopus 로고
    • Argon laser ablation of malignant ventricular tachycardia associated with coronary artery disease
    • Saksena S, Gielchinsky I, Tullo NG. Argon laser ablation of malignant ventricular tachycardia associated with coronary artery disease. Am J Cardiol 1989; 64:1298-1304.
    • (1989) Am J Cardiol , vol.64 , pp. 1298-1304
    • Saksena, S.1    Gielchinsky, I.2    Tullo, N.G.3
  • 21
    • 0030470974 scopus 로고    scopus 로고
    • Epicardial neodymium. YAG laser photocoagulation of ventricular tachycardia without ventriculotomy in patients after myocardial infarction
    • Pfeiffer D, Moosdorf R, Svenson RH, et al. Epicardial neodymium. YAG laser photocoagulation of ventricular tachycardia without ventriculotomy in patients after myocardial infarction. Circulation 1996; 94:3221-3225.
    • (1996) Circulation , vol.94 , pp. 3221-3225
    • Pfeiffer, D.1    Moosdorf, R.2    Svenson, R.H.3
  • 22
    • 0033616849 scopus 로고    scopus 로고
    • Slow intramural heating with diffused laser light: A unique method for deep myocardial coagulation
    • Ware DL, Boor P, Yang C, Gowda A, Grady JJ, Motamedi M. Slow intramural heating with diffused laser light: A unique method for deep myocardial coagulation. Circulation 1999; 99:1630-1636.
    • (1999) Circulation , vol.99 , pp. 1630-1636
    • Ware, D.L.1    Boor, P.2    Yang, C.3    Gowda, A.4    Grady, J.J.5    Motamedi, M.6
  • 23
    • 0033527261 scopus 로고    scopus 로고
    • Linear atrial ablation with a diode laser and fiberoptic catheter
    • Keane D, Ruskin JN. Linear atrial ablation with a diode laser and fiberoptic catheter. Circulation 1999; 100:e59-e60.
    • (1999) Circulation , vol.100
    • Keane, D.1    Ruskin, J.N.2
  • 24
    • 0033783375 scopus 로고    scopus 로고
    • Linear lesions in myocardium created by Nd:YAG laser using diffusing optical fibers: In vitro and in vivo results
    • Fried NM, Lardo AC, Berger RD, Calkins H, Halperin HR. Linear lesions in myocardium created by Nd:YAG laser using diffusing optical fibers: In vitro and in vivo results. Lasers Surg Med 2000; 27:295-304.
    • (2000) Lasers Surg Med , vol.27 , pp. 295-304
    • Fried, N.M.1    Lardo, A.C.2    Berger, R.D.3    Calkins, H.4    Halperin, H.R.5
  • 25
    • 0021216183 scopus 로고
    • Mechanisms of tissue destruction following cryosurgery
    • Whittaker DK. Mechanisms of tissue destruction following cryosurgery. Ann R Coll Surg Engl 1984; 66:313-318.
    • (1984) Ann R Coll Surg Engl , vol.66 , pp. 313-318
    • Whittaker, D.K.1
  • 26
    • 0035058539 scopus 로고    scopus 로고
    • Catheter cryoablation of the atrioventricular node in patients with atrial fibrillation: A novel technology for ablation of cardiac arrhythmias
    • Dubuc M, Khairy P, Rodriguez-Santiago A, et al. Catheter cryoablation of the atrioventricular node in patients with atrial fibrillation: A novel technology for ablation of cardiac arrhythmias. J Cardiovasc Electrophysiol 2001; 12:439-444.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 439-444
    • Dubuc, M.1    Khairy, P.2    Rodriguez-Santiago, A.3
  • 27
    • 3042857297 scopus 로고    scopus 로고
    • Catheter cryoablation of supraventricular tachycardia: Results of the multicenter prospective "frosty" trial
    • Friedman P, Dubuc M, Green M, et al. Catheter cryoablation of supraventricular tachycardia: Results of the multicenter prospective "frosty" trial. Heart Rhythm 2004; 1:129-138.
    • (2004) Heart Rhythm , vol.1 , pp. 129-138
    • Friedman, P.1    Dubuc, M.2    Green, M.3
  • 28
    • 0037461289 scopus 로고    scopus 로고
    • Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation
    • Khairy P, Chauvet P, Lehmann J, et al. Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation. Circulation 2003; 107:2045-2050.
    • (2003) Circulation , vol.107 , pp. 2045-2050
    • Khairy, P.1    Chauvet, P.2    Lehmann, J.3
  • 29
    • 4344653746 scopus 로고    scopus 로고
    • β-radiation for the creation of linear lesions in the canine atrium
    • Guerra P, Talajic M, Thibault B, et al. β-radiation for the creation of linear lesions in the canine atrium. Circulation 2004; 110:911-914.
    • (2004) Circulation , vol.110 , pp. 911-914
    • Guerra, P.1    Talajic, M.2    Thibault, B.3
  • 30
    • 4544388471 scopus 로고    scopus 로고
    • Asymptomatic acute inferior ST elevation myocardial infarction from thermal injury complicating radiofrequency ablation for atrioventricular re-entrant tachycardia
    • Chacko M, Marrouche NF, Bhatt DL. Asymptomatic acute inferior ST elevation myocardial infarction from thermal injury complicating radiofrequency ablation for atrioventricular re-entrant tachycardia. J Invasive Cardiol 2004; 16:504-505.
    • (2004) J Invasive Cardiol , vol.16 , pp. 504-505
    • Chacko, M.1    Marrouche, N.F.2    Bhatt, D.L.3
  • 31
    • 7044239321 scopus 로고    scopus 로고
    • Acute myocardial infarction after radiofrequency catheter ablation of typical atrial flutter: Histopathological findings and etiopathogenetic hypothesis
    • Sassone B, Leone O, Martinelli GN, Di Pasquale G. Acute myocardial infarction after radiofrequency catheter ablation of typical atrial flutter: Histopathological findings and etiopathogenetic hypothesis. Ital Heart J 2004; 5:403-407.
    • (2004) Ital Heart J , vol.5 , pp. 403-407
    • Sassone, B.1    Leone, O.2    Martinelli, G.N.3    Di Pasquale, G.4
  • 32
    • 0036316193 scopus 로고    scopus 로고
    • Sudden death following rupture of a right ventricular aneurysm 9 months after ablation therapy of the right ventricular outflow tract
    • Wolf DA, Burke AP, Patterson KV, Virmani R. Sudden death following rupture of a right ventricular aneurysm 9 months after ablation therapy of the right ventricular outflow tract. PACE 2002; 25:1135-1137.
    • (2002) PACE , vol.25 , pp. 1135-1137
    • Wolf, D.A.1    Burke, A.P.2    Patterson, K.V.3    Virmani, R.4
  • 33
    • 0036851389 scopus 로고    scopus 로고
    • Acute results of transvenous cryoablation of supraventricular tachycardia (atrial fibrillation, atrial flutter, Wolff-Parkinson-White syndrome, atrioventricular nodal reentry tachycardia)
    • Rodriguez LM, Geller JC, Tse HF, et al. Acute results of transvenous cryoablation of supraventricular tachycardia (atrial fibrillation, atrial flutter, Wolff-Parkinson-White syndrome, atrioventricular nodal reentry tachycardia). J Cardiovasc Electrophysiol 2002; 13:1082-1089.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 1082-1089
    • Rodriguez, L.M.1    Geller, J.C.2    Tse, H.F.3
  • 34
    • 0034131310 scopus 로고    scopus 로고
    • The 1998 NASPE prospective catheter ablation registry
    • Scheinman MM, Huang S. The 1998 NASPE prospective catheter ablation registry. PACE 2000; 23:1020-1028.
    • (2000) PACE , vol.23 , pp. 1020-1028
    • Scheinman, M.M.1    Huang, S.2
  • 35
    • 4243985582 scopus 로고    scopus 로고
    • Reversible cryomapping of the slow pathway during catheter cryoablation of atrioventricular nodal reentrant supraventricular tachycardia
    • Friedman P, Stevenson WG, Tchou PJ, et al. Reversible cryomapping of the slow pathway during catheter cryoablation of atrioventricular nodal reentrant supraventricular tachycardia. (abstract) Circulation 2000; II-368.
    • (2000) (Abstract) Circulation
    • Friedman, P.1    Stevenson, W.G.2    Tchou, P.J.3
  • 36
    • 0037432308 scopus 로고    scopus 로고
    • Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception
    • Timmermans C, Ayers GM, Crijns HJ, Rodriguez LM. Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception. Circulation 2003; 107:1250-1252.
    • (2003) Circulation , vol.107 , pp. 1250-1252
    • Timmermans, C.1    Ayers, G.M.2    Crijns, H.J.3    Rodriguez, L.M.4
  • 37
    • 0037036848 scopus 로고    scopus 로고
    • Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: Impact of different catheter technologies
    • Marrouche NF, Dresing T, Cole C, et al. Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: Impact of different catheter technologies. J Am Coll Cardiol 2002; 40:464-474.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 464-474
    • Marrouche, N.F.1    Dresing, T.2    Cole, C.3
  • 38
    • 0036763615 scopus 로고    scopus 로고
    • Pulmonary vein isolation for atrial fibrillation
    • Keane D, Ruskin J. Pulmonary vein isolation for atrial fibrillation. Rev Cardiovasc Med 2002; 3:167-175.
    • (2002) Rev Cardiovasc Med , vol.3 , pp. 167-175
    • Keane, D.1    Ruskin, J.2
  • 39
    • 0036774489 scopus 로고    scopus 로고
    • Use of intracardiac echocardiography for prediction of chronic pulmonary vein stenosis after ablation of atrial fibrillation
    • Saad EB, Cole CR, Marrouche NF, et al. Use of intracardiac echocardiography for prediction of chronic pulmonary vein stenosis after ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2002; 13:986-989.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 986-989
    • Saad, E.B.1    Cole, C.R.2    Marrouche, N.F.3
  • 40
    • 0037250360 scopus 로고    scopus 로고
    • Catheter cryoablation of supraventricular arrhythmias: A painless alternative to radiofrequency energy
    • Lowe MD, Meara M, Mason J, Grace AA, Murgatroyd FD. Catheter cryoablation of supraventricular arrhythmias: A painless alternative to radiofrequency energy. PACE 2003; 26:500-503.
    • (2003) PACE , vol.26 , pp. 500-503
    • Lowe, M.D.1    Meara, M.2    Mason, J.3    Grace, A.A.4    Murgatroyd, F.D.5
  • 41
    • 0041730576 scopus 로고    scopus 로고
    • Pulmonary vein isolation using transvenous catheter cryoablation for treatment of atrial fibrillation without risk of pulmonary vein stenosis
    • Tse HF, Reek S, Timmermans C, et al. Pulmonary vein isolation using transvenous catheter cryoablation for treatment of atrial fibrillation without risk of pulmonary vein stenosis. J Am Coll Cardiol 2003; 42:752-758.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 752-758
    • Tse, H.F.1    Reek, S.2    Timmermans, C.3
  • 43
    • 1842854735 scopus 로고    scopus 로고
    • Percutaneous isolation of multiple pulmonary veins using an expandable circular cryoablation catheter
    • Wong T, Markides V, Peters NS, Wright AR, Davies DW. Percutaneous isolation of multiple pulmonary veins using an expandable circular cryoablation catheter. PACE 2004; 27:551-554.
    • (2004) PACE , vol.27 , pp. 551-554
    • Wong, T.1    Markides, V.2    Peters, N.S.3    Wright, A.R.4    Davies, D.W.5
  • 44
    • 3242798922 scopus 로고    scopus 로고
    • Pulmonary vein isolation during atrial fibrillation using a circumferential cryoablation catheter
    • Rostock T, Weiss C, Ventura R, Willems S. Pulmonary vein isolation during atrial fibrillation using a circumferential cryoablation catheter. PACE 2004; 27:1024-1025.
    • (2004) PACE , vol.27 , pp. 1024-1025
    • Rostock, T.1    Weiss, C.2    Ventura, R.3    Willems, S.4
  • 45
    • 0037354665 scopus 로고    scopus 로고
    • Use of different catheter ablation technologies for treatment of typical atrial flutter: Acute results and long-term follow-up
    • Marrouche NF, Schweikert R, Saliba W, et al. Use of different catheter ablation technologies for treatment of typical atrial flutter: Acute results and long-term follow-up. PACE 2003; 26:743-746.
    • (2003) PACE , vol.26 , pp. 743-746
    • Marrouche, N.F.1    Schweikert, R.2    Saliba, W.3
  • 46
    • 0034065874 scopus 로고    scopus 로고
    • Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation
    • VanderBrink BA, Gilbride C, Aronovitz MJ, et al. Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation. J Cardiovasc Electrophysiol 2000; 11:305-310.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 305-310
    • VanderBrink, B.A.1    Gilbride, C.2    Aronovitz, M.J.3
  • 47
    • 1942423054 scopus 로고    scopus 로고
    • In vitro and in vivo evaluation of the thermal patterns and lesions of catheter ablation with a microwave monopole antenna
    • Keane D, Ruskin J, Norris N, Chapelon PA, Berube D. In vitro and in vivo evaluation of the thermal patterns and lesions of catheter ablation with a microwave monopole antenna. J Interv Card Electrophysiol 2004; 10:111-119.
    • (2004) J Interv Card Electrophysiol , vol.10 , pp. 111-119
    • Keane, D.1    Ruskin, J.2    Norris, N.3    Chapelon, P.A.4    Berube, D.5
  • 48
    • 0030782970 scopus 로고    scopus 로고
    • A prospective evaluation of catheter ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an implantable cardioverter-defibrillator
    • Strickberger SA, Man KC, Daoud EG, et al. A prospective evaluation of catheter ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an implantable cardioverter-defibrillator. Circulation 1997; 96:1525-1531.
    • (1997) Circulation , vol.96 , pp. 1525-1531
    • Strickberger, S.A.1    Man, K.C.2    Daoud, E.G.3
  • 49
  • 50
    • 0038647798 scopus 로고    scopus 로고
    • Short-term results of substrate mapping and radiofrequency ablation of ischemic ventricular tachycardia using a saline-irrigated catheter
    • Reddy VY, Neuzil P, Taborsky M, Ruskin JN. Short-term results of substrate mapping and radiofrequency ablation of ischemic ventricular tachycardia using a saline-irrigated catheter. J Am Coll Cardiol 2003; 41:2228-2236.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 2228-2236
    • Reddy, V.Y.1    Neuzil, P.2    Taborsky, M.3    Ruskin, J.N.4
  • 51
    • 0043095360 scopus 로고    scopus 로고
    • Recent advances in the treatment of arrhythmias
    • Grant AO. Recent advances in the treatment of arrhythmias. Circ J 2003; 67:651-655.
    • (2003) Circ J , vol.67 , pp. 651-655
    • Grant, A.O.1
  • 52
    • 0242636809 scopus 로고    scopus 로고
    • Catheter intramural needle radiofrequency ablation creates deeper lesions than irrigated tip catheter ablation
    • Thiagalingam A, Campbell CR, Boyd A, Ross DL, Kovoor P. Catheter intramural needle radiofrequency ablation creates deeper lesions than irrigated tip catheter ablation. PACE 2003; 26:2146-2150.
    • (2003) PACE , vol.26 , pp. 2146-2150
    • Thiagalingam, A.1    Campbell, C.R.2    Boyd, A.3    Ross, D.L.4    Kovoor, P.5
  • 53
    • 1942516919 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- Or 10-mm electrode catheters and a high-output radiofrequency energy generator: Results of a multicenter safety and efficacy study
    • Feld G, Wharton M, Plumb V, Daoud E, Friehling T, Epstein L. Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8- or 10-mm electrode catheters and a high-output radiofrequency energy generator: Results of a multicenter safety and efficacy study. J Am Coll Cardiol 2004; 43:1466-1472.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1466-1472
    • Feld, G.1    Wharton, M.2    Plumb, V.3    Daoud, E.4    Friehling, T.5    Epstein, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.