메뉴 건너뛰기




Volumn 48, Issue 1, 2005, Pages 367-372

Comparison of direct vs. indirect ventilation rate determinations in layer barns using manure belts

Author keywords

Air emissions; Building ventilation rate; CO2 balance; Laying hen

Indexed keywords

AIR; DUST; MANURES; METABOLISM; VENTILATION;

EID: 18644366591     PISSN: 00012351     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (60)

References (12)
  • 1
    • 0000302124 scopus 로고
    • Report of sub-committee on constant and factors
    • K. L. Blaxter, ed. Rome, Italy: European Association for Animal Production
    • Brouwer, E. 1965. Report of sub-committee on constant and factors. In Energy Metabolism: Proc. 3rd Symposium held in Troon, Scotland, 11: 441-443. K. L. Blaxter, ed. Rome, Italy: European Association for Animal Production.
    • (1965) Energy Metabolism: Proc. 3rd Symposium Held in Troon, Scotland , vol.11 , pp. 441-443
    • Brouwer, E.1
  • 3
    • 20344392908 scopus 로고    scopus 로고
    • Heat and moisture production of poultry and their housing systems: Molting layers
    • Chepete, H. J., and H. Xin. 2004. Heat and moisture production of poultry and their housing systems: Molting layers. Trans. ASHRAE 110(2): 247-285.
    • (2004) Trans. ASHRAE , vol.110 , Issue.2 , pp. 247-285
    • Chepete, H.J.1    Xin, H.2
  • 4
    • 20344392908 scopus 로고    scopus 로고
    • Heat and moisture production of poultry and their housing systems: Pullets and layers
    • Chepete, H. J., H. Xin, M. C. Puma, and R. S. Gates. 2004. Heat and moisture production of poultry and their housing systems: Pullets and layers. Trans. ASHRAE 110(2): 268-299.
    • (2004) Trans. ASHRAE , vol.110 , Issue.2 , pp. 268-299
    • Chepete, H.J.1    Xin, H.2    Puma, M.C.3    Gates, R.S.4
  • 5
    • 0021448639 scopus 로고
    • Carbon dioxide concentration as a measure of air exchange in animal housing
    • Feddes, J. J., J. J. Leonard, and J. B. McQuitty. 1984. Carbon dioxide concentration as a measure of air exchange in animal housing. Canadian Agric. Eng. 26(1): 53-56.
    • (1984) Canadian Agric. Eng. , vol.26 , Issue.1 , pp. 53-56
    • Feddes, J.J.1    Leonard, J.J.2    McQuitty, J.B.3
  • 6
    • 11144296280 scopus 로고    scopus 로고
    • Fan assessment numeration system (FANS) design and calibration specifications
    • Gates, R. S., K. D. Casey, H. Xin, E. F. Wheeler, and J. D. Simmons. 2004. Fan assessment numeration system (FANS) design and calibration specifications. Trans. ASAE 47(5): 1709-1715.
    • (2004) Trans. ASAE , vol.47 , Issue.5 , pp. 1709-1715
    • Gates, R.S.1    Casey, K.D.2    Xin, H.3    Wheeler, E.F.4    Simmons, J.D.5
  • 7
    • 0001039894 scopus 로고    scopus 로고
    • A review of methods for measuring emission rates of ammonia from livestock buildings and slurry or manure stores: Part 1. Assessment of basic approaches
    • Phillips, V. R., R. Scholtens, D. S. Lee, J. A. Garland, and R. W. Sneath. 2000. A review of methods for measuring emission rates of ammonia from livestock buildings and slurry or manure stores: Part 1. Assessment of basic approaches. J. Agric. Eng. Res. 77(4): 355-364.
    • (2000) J. Agric. Eng. Res. , vol.77 , Issue.4 , pp. 355-364
    • Phillips, V.R.1    Scholtens, R.2    Lee, D.S.3    Garland, J.A.4    Sneath, R.W.5
  • 8
    • 0002821243 scopus 로고    scopus 로고
    • A review of methods for measuring emission rates of ammonia from livestock buildings and slurry or manure stores: Part 2. Monitoring flux rates, concentrations, and airflow rates
    • Phillips, V. R., D. S. Lee, R. Scholtens, J. A. Garland, and R. W. Sneath. 2001. A review of methods for measuring emission rates of ammonia from livestock buildings and slurry or manure stores: Part 2. Monitoring flux rates, concentrations, and airflow rates. J. Agric. Eng. Res. 78(1): 1-14.
    • (2001) J. Agric. Eng. Res. , vol.78 , Issue.1 , pp. 1-14
    • Phillips, V.R.1    Lee, D.S.2    Scholtens, R.3    Garland, J.A.4    Sneath, R.W.5
  • 9
    • 0032207928 scopus 로고    scopus 로고
    • A portable anemometer to determine the output of large in-place ventilation fans
    • Simmons, J. D., T. E. Hannigan, and B. D. Lott. 1998. A portable anemometer to determine the output of large in-place ventilation fans. Applied Eng. in Agric. 14(6): 649-653.
    • (1998) Applied Eng. in Agric. , vol.14 , Issue.6 , pp. 649-653
    • Simmons, J.D.1    Hannigan, T.E.2    Lott, B.D.3
  • 10
    • 0001031685 scopus 로고
    • Application of the carbon dioxide mass balance method to evaluate ventilation rates in livestock buildings
    • Bonn, Germany: CIGR General Secretariat
    • Van Ouwerkerk, E. N. J., and S. Pedersen. 1994. Application of the carbon dioxide mass balance method to evaluate ventilation rates in livestock buildings. In Proc. XII World Congress on Agricultural Engineering, 1: 516-529. Bonn, Germany: CIGR General Secretariat.
    • (1994) Proc. XII World Congress on Agricultural Engineering , vol.1 , pp. 516-529
    • Van Ouwerkerk, E.N.J.1    Pedersen, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.