Volumn 47, Issue 5, 2004, Pages 1709-1715

Fan Assessment Numeration System (FANS) design and calibration specifications

Author keywords

Controlled environment; Emissions; Instrumentation; Livestock housing; Poultry; Ventilation

Indexed keywords

ANEMOMETERS; CALIBRATION; COMPUTER HARDWARE; COMPUTER SOFTWARE; ERROR ANALYSIS; PROPELLERS;

EID: 11144296280     PISSN: 00012351     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (150)

References (10)
  • 2
    • 0042020576 scopus 로고    scopus 로고
    • Laboratory Methods of Testing Fans for Aerodynamic Performance Rating
    • Chicago, Ill.: Air Movement and Control Association International, Inc.
    • AMCA. 1999. Laboratory Methods of Testing Fans for Aerodynamic Performance Rating. ANSI/AMCA Standard 210-99. Chicago, Ill.: Air Movement and Control Association International, Inc.
    • (1999) ANSI/AMCA Standard , pp. 210-299
  • 3
    • 0004278899 scopus 로고    scopus 로고
    • Atlanta, Ga.: ASHRAE
    • ASHRAE. 2001. Handbook of Fundamentals. Atlanta, Ga.: ASHRAE.
    • (2001) Handbook of Fundamentals
  • 5
    • 4244031052 scopus 로고    scopus 로고
    • Air quality and emissions from livestock and poultry production/waste management systems
    • Raleigh N.C.: North Carolina State University, Available from Midwest Plan Service, Ames Iowa
    • Bicudo, J. R., S. W. Gay, D. R. Schmidt, R. S. Gates, L. D. Jacobson, and S. J. Hoff. 2002. Air quality and emissions from livestock and poultry production/waste management systems. Raleigh N.C.: North Carolina State University, National Center for Manure and Animal Waste Management White Papers. Available from Midwest Plan Service, Ames Iowa.
    • (2002) National Center for Manure and Animal Waste Management White Papers
    • Bicudo, J.R.1    Gay, S.W.2    Schmidt, D.R.3    Gates, R.S.4    Jacobson, L.D.5    Hoff, S.J.6
  • 7
    • 0032207928 scopus 로고    scopus 로고
    • A portable anemometer to determine the output of large in-place ventilation fans
    • Simmons, J. D., T. E. Hannigan, and B. D. Lott. 1998a. A portable anemometer to determine the output of large in-place ventilation fans. Applied Eng. in Agric. 14(6): 649-653.
    • (1998) Applied Eng. in Agric. , vol.14 , Issue.6 , pp. 649-653
    • Simmons, J.D.1    Hannigan, T.E.2    Lott, B.D.3
  • 8
    • 0032167094 scopus 로고    scopus 로고
    • Minimum distance between ventilation fans in adjacent walls of tunnel-ventilated broiler houses
    • Simmons, J. D., B. D. Lott, and T. E. Hannigan. 1998b. Minimum distance between ventilation fans in adjacent walls of tunnel-ventilated broiler houses. Applied Eng. in Agric. 14(5): 533-535.
    • (1998) Applied Eng. in Agric. , vol.14 , Issue.5 , pp. 533-535
    • Simmons, J.D.1    Lott, B.D.2    Hannigan, T.E.3
  • 9
    • 11144325554 scopus 로고    scopus 로고
    • Go with the flow
    • St. Joseph, Mich.: ASAE
    • Simmons, J. D., and T. E. Hannigan. 2000. Go with the flow. Resource (May): 9-10. St. Joseph, Mich.: ASAE.
    • (2000) Resource , Issue.MAY , pp. 9-10
    • Simmons, J.D.1    Hannigan, T.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.