메뉴 건너뛰기




Volumn 20, Issue 1, 2005, Pages 106-110

Infrared ear thermometry in the critically ill patient: An alternative to axillary thermometry

Author keywords

Axillary thermometry; Ear thermometry; Infrared tympanic thermometer; Intensive care unit; Mercury in glass thermometer; Temperature measurement

Indexed keywords

MERCURY;

EID: 18044368316     PISSN: 08839441     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrc.2004.08.011     Document Type: Article
Times cited : (19)

References (22)
  • 1
    • 0037348764 scopus 로고    scopus 로고
    • Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method
    • J.Y. Lefrant, L. Muller, and J.E. de La Coussaye Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method Intensive Care Med 29 2003 414 418
    • (2003) Intensive Care Med , vol.29 , pp. 414-418
    • Lefrant, J.Y.1    Muller, L.2    De La Coussaye, J.E.3
  • 2
    • 0029339592 scopus 로고
    • A comparison of five methods of temperature measurement in febrile intensive care patients
    • T. Schmitz, N. Bair, and M. Falk A comparison of five methods of temperature measurement in febrile intensive care patients Am J Crit Care 4 1995 286 292
    • (1995) Am J Crit Care , vol.4 , pp. 286-292
    • Schmitz, T.1    Bair, N.2    Falk, M.3
  • 3
    • 0036092075 scopus 로고    scopus 로고
    • Normal oral, rectal, tympanic and axillary body temperatures in adult men and women: A systematic literature review
    • M. Sund-Levander, C. Forsberg, and L.K. Wahren Normal oral, rectal, tympanic and axillary body temperatures in adult men and women: a systematic literature review Scand J Caring Sci 16 2002 122 128
    • (2002) Scand J Caring Sci , vol.16 , pp. 122-128
    • Sund-Levander, M.1    Forsberg, C.2    Wahren, L.K.3
  • 4
    • 0031215874 scopus 로고    scopus 로고
    • Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever
    • K. Osinusi, and M.N. Njinyam Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever Afr J Med Sci 26 1997 163 166
    • (1997) Afr J Med Sci , vol.26 , pp. 163-166
    • Osinusi, K.1    Njinyam, M.N.2
  • 5
    • 0025801269 scopus 로고
    • Comparison of pulmonary artery, rectal, and tympanic membrane temperatures in adult intensive care unit patients
    • A. Milewski, K.L. Ferguson, and T.E. Terndrup Comparison of pulmonary artery, rectal, and tympanic membrane temperatures in adult intensive care unit patients Clin Pediatr (Phila) 30 4 Suppl. 1991 13 16
    • (1991) Clin Pediatr (Phila) , vol.30 , Issue.4 SUPPL. , pp. 13-16
    • Milewski, A.1    Ferguson, K.L.2    Terndrup, T.E.3
  • 6
    • 0026119110 scopus 로고
    • Laboratory and hospital testing of new infrared tympanic thermometers
    • M.E. Weiss, A.F. Pue, and J. Smith III Laboratory and hospital testing of new infrared tympanic thermometers J Clin Eng 16 1991 137 144
    • (1991) J Clin Eng , vol.16 , pp. 137-144
    • Weiss, M.E.1    Pue, A.F.2    Smith III, J.3
  • 7
    • 0029825365 scopus 로고    scopus 로고
    • Infrared tympanic temperature as a predictor of rectal temperature in warm and hot conditions
    • R.D. Hansen, D. Amos, and B. Leake Infrared tympanic temperature as a predictor of rectal temperature in warm and hot conditions Aviat Space Environ Med 67 1996 1048 1052
    • (1996) Aviat Space Environ Med , vol.67 , pp. 1048-1052
    • Hansen, R.D.1    Amos, D.2    Leake, B.3
  • 8
    • 0031041834 scopus 로고    scopus 로고
    • Comparison of tympanic, esophageal and blood temperatures during mild hypothermic cardiopulmonary bypass: A study using an infrared emission detection tympanic thermometer
    • K. Harasawa, O. Kemmotsu, and T. Mayumi Comparison of tympanic, esophageal and blood temperatures during mild hypothermic cardiopulmonary bypass: a study using an infrared emission detection tympanic thermometer J Clin Monit 13 1997 19 24
    • (1997) J Clin Monit , vol.13 , pp. 19-24
    • Harasawa, K.1    Kemmotsu, O.2    Mayumi, T.3
  • 9
    • 0034189095 scopus 로고    scopus 로고
    • Temperature taking in the ICU: Which route is best?
    • K. Cronin, and M. Wallis Temperature taking in the ICU: which route is best? Aust Crit Care 13 2000 59 64
    • (2000) Aust Crit Care , vol.13 , pp. 59-64
    • Cronin, K.1    Wallis, M.2
  • 10
    • 0033989396 scopus 로고    scopus 로고
    • Comparison of rectal and infrared ear temperatures in older hospital inpatients
    • S. Smitz, T. Giagoultsis, and W. Dewe Comparison of rectal and infrared ear temperatures in older hospital inpatients J Am Geriatr Soc 48 2000 63 66
    • (2000) J Am Geriatr Soc , vol.48 , pp. 63-66
    • Smitz, S.1    Giagoultsis, T.2    Dewe, W.3
  • 11
    • 0035155275 scopus 로고    scopus 로고
    • Validity of the tympanic infrared thermometer in geriatric inpatients
    • H. Baeyens, G. De Dobbeleer, and J.P. Baeyens Validity of the tympanic infrared thermometer in geriatric inpatients Tijdschr Gerontol Geriatr 32 2001 206 209
    • (2001) Tijdschr Gerontol Geriatr , vol.32 , pp. 206-209
    • Baeyens, H.1    De Dobbeleer, G.2    Baeyens, J.P.3
  • 13
    • 0031013838 scopus 로고    scopus 로고
    • Accuracy of infrared ear thermometry in adult patients
    • K. Stavem, H. Saxholm, and N. Smith-Erichsen Accuracy of infrared ear thermometry in adult patients Intensive Care Med 23 1997 100 105
    • (1997) Intensive Care Med , vol.23 , pp. 100-105
    • Stavem, K.1    Saxholm, H.2    Smith-Erichsen, N.3
  • 14
    • 0032964769 scopus 로고    scopus 로고
    • Accuracy of an infrared tympanic thermometer
    • Y. Amoateng-Adjepong, J. Del Mundo, and C.A. Manthous Accuracy of an infrared tympanic thermometer Chest 115 1999 1002 1005
    • (1999) Chest , vol.115 , pp. 1002-1005
    • Amoateng-Adjepong, Y.1    Del Mundo, J.2    Manthous, C.A.3
  • 15
    • 17144417968 scopus 로고    scopus 로고
    • Accurate measurement of body temperature in the neonate. A comparative study
    • S. Browne, H. Coleman, and E. Geary Accurate measurement of body temperature in the neonate. A comparative study J Neonatal Nurs 6 2000 165 168
    • (2000) J Neonatal Nurs , vol.6 , pp. 165-168
    • Browne, S.1    Coleman, H.2    Geary, E.3
  • 16
    • 0000981107 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet i 1989 307 310
    • (1989) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0037167250 scopus 로고    scopus 로고
    • Infrared ear thermometry compared with rectal thermometry in children: A systematic review
    • J.V. Craig, G.A. Lancaster, and S. Taylor Infrared ear thermometry compared with rectal thermometry in children: a systematic review Lancet 360 2002 603 609
    • (2002) Lancet , vol.360 , pp. 603-609
    • Craig, J.V.1    Lancaster, G.A.2    Taylor, S.3
  • 19
    • 0021327044 scopus 로고
    • Temperature measurement in term and preterm neonates
    • S.R. Mayfield, J. Bhatia, and K.T. Nakamura Temperature measurement in term and preterm neonates J Pediatr 104 1984 271 275
    • (1984) J Pediatr , vol.104 , pp. 271-275
    • Mayfield, S.R.1    Bhatia, J.2    Nakamura, K.T.3
  • 20
    • 0022759594 scopus 로고
    • Axillary and rectal temperatures of full-term neonates: Are they different?
    • B. Haddock, P. Vincent, and D. Merrow Axillary and rectal temperatures of full-term neonates: are they different? Neonatal Netw 5 1986 36 40
    • (1986) Neonatal Netw , vol.5 , pp. 36-40
    • Haddock, B.1    Vincent, P.2    Merrow, D.3
  • 21
    • 0019017392 scopus 로고
    • Oral temperature differences in relation to thermometer and technique
    • R. Erickson Oral temperature differences in relation to thermometer and technique Nurs Res 29 1980 157 164
    • (1980) Nurs Res , vol.29 , pp. 157-164
    • Erickson, R.1
  • 22
    • 0034728879 scopus 로고    scopus 로고
    • Temperature measured at the axilla compared with rectum in children and young people: Systematic review
    • J.V. Craig, G.A. Lancaster, P.R. Williamson, and R.L. Smyth Temperature measured at the axilla compared with rectum in children and young people: systematic review BMJ 320 2000 1174 1178
    • (2000) BMJ , vol.320 , pp. 1174-1178
    • Craig, J.V.1    Lancaster, G.A.2    Williamson, P.R.3    Smyth, R.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.