1
-
-
0037348764
-
Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method
-
J.Y. Lefrant, L. Muller, and J.E. de La Coussaye Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method Intensive Care Med 29 2003 414 418
-
(2003)
Intensive Care Med
, vol.29
, pp. 414-418
-
-
Lefrant, J.Y.1
Muller, L.2
De La Coussaye, J.E.3
-
2
-
-
0029339592
-
A comparison of five methods of temperature measurement in febrile intensive care patients
-
T. Schmitz, N. Bair, and M. Falk A comparison of five methods of temperature measurement in febrile intensive care patients Am J Crit Care 4 1995 286 292
-
(1995)
Am J Crit Care
, vol.4
, pp. 286-292
-
-
Schmitz, T.1
Bair, N.2
Falk, M.3
-
3
-
-
0036092075
-
Normal oral, rectal, tympanic and axillary body temperatures in adult men and women: A systematic literature review
-
M. Sund-Levander, C. Forsberg, and L.K. Wahren Normal oral, rectal, tympanic and axillary body temperatures in adult men and women: a systematic literature review Scand J Caring Sci 16 2002 122 128
-
(2002)
Scand J Caring Sci
, vol.16
, pp. 122-128
-
-
Sund-Levander, M.1
Forsberg, C.2
Wahren, L.K.3
-
4
-
-
0031215874
-
Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever
-
K. Osinusi, and M.N. Njinyam Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever Afr J Med Sci 26 1997 163 166
-
(1997)
Afr J Med Sci
, vol.26
, pp. 163-166
-
-
Osinusi, K.1
Njinyam, M.N.2
-
5
-
-
0025801269
-
Comparison of pulmonary artery, rectal, and tympanic membrane temperatures in adult intensive care unit patients
-
A. Milewski, K.L. Ferguson, and T.E. Terndrup Comparison of pulmonary artery, rectal, and tympanic membrane temperatures in adult intensive care unit patients Clin Pediatr (Phila) 30 4 Suppl. 1991 13 16
-
(1991)
Clin Pediatr (Phila)
, vol.30
, Issue.4 SUPPL.
, pp. 13-16
-
-
Milewski, A.1
Ferguson, K.L.2
Terndrup, T.E.3
-
6
-
-
0026119110
-
Laboratory and hospital testing of new infrared tympanic thermometers
-
M.E. Weiss, A.F. Pue, and J. Smith III Laboratory and hospital testing of new infrared tympanic thermometers J Clin Eng 16 1991 137 144
-
(1991)
J Clin Eng
, vol.16
, pp. 137-144
-
-
Weiss, M.E.1
Pue, A.F.2
Smith III, J.3
-
7
-
-
0029825365
-
Infrared tympanic temperature as a predictor of rectal temperature in warm and hot conditions
-
R.D. Hansen, D. Amos, and B. Leake Infrared tympanic temperature as a predictor of rectal temperature in warm and hot conditions Aviat Space Environ Med 67 1996 1048 1052
-
(1996)
Aviat Space Environ Med
, vol.67
, pp. 1048-1052
-
-
Hansen, R.D.1
Amos, D.2
Leake, B.3
-
8
-
-
0031041834
-
Comparison of tympanic, esophageal and blood temperatures during mild hypothermic cardiopulmonary bypass: A study using an infrared emission detection tympanic thermometer
-
K. Harasawa, O. Kemmotsu, and T. Mayumi Comparison of tympanic, esophageal and blood temperatures during mild hypothermic cardiopulmonary bypass: a study using an infrared emission detection tympanic thermometer J Clin Monit 13 1997 19 24
-
(1997)
J Clin Monit
, vol.13
, pp. 19-24
-
-
Harasawa, K.1
Kemmotsu, O.2
Mayumi, T.3
-
9
-
-
0034189095
-
Temperature taking in the ICU: Which route is best?
-
K. Cronin, and M. Wallis Temperature taking in the ICU: which route is best? Aust Crit Care 13 2000 59 64
-
(2000)
Aust Crit Care
, vol.13
, pp. 59-64
-
-
Cronin, K.1
Wallis, M.2
-
10
-
-
0033989396
-
Comparison of rectal and infrared ear temperatures in older hospital inpatients
-
S. Smitz, T. Giagoultsis, and W. Dewe Comparison of rectal and infrared ear temperatures in older hospital inpatients J Am Geriatr Soc 48 2000 63 66
-
(2000)
J Am Geriatr Soc
, vol.48
, pp. 63-66
-
-
Smitz, S.1
Giagoultsis, T.2
Dewe, W.3
-
11
-
-
0035155275
-
Validity of the tympanic infrared thermometer in geriatric inpatients
-
H. Baeyens, G. De Dobbeleer, and J.P. Baeyens Validity of the tympanic infrared thermometer in geriatric inpatients Tijdschr Gerontol Geriatr 32 2001 206 209
-
(2001)
Tijdschr Gerontol Geriatr
, vol.32
, pp. 206-209
-
-
Baeyens, H.1
De Dobbeleer, G.2
Baeyens, J.P.3
-
15
-
-
17144417968
-
Accurate measurement of body temperature in the neonate. A comparative study
-
S. Browne, H. Coleman, and E. Geary Accurate measurement of body temperature in the neonate. A comparative study J Neonatal Nurs 6 2000 165 168
-
(2000)
J Neonatal Nurs
, vol.6
, pp. 165-168
-
-
Browne, S.1
Coleman, H.2
Geary, E.3
-
16
-
-
0000981107
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet i 1989 307 310
-
(1989)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
17
-
-
0037167250
-
Infrared ear thermometry compared with rectal thermometry in children: A systematic review
-
J.V. Craig, G.A. Lancaster, and S. Taylor Infrared ear thermometry compared with rectal thermometry in children: a systematic review Lancet 360 2002 603 609
-
(2002)
Lancet
, vol.360
, pp. 603-609
-
-
Craig, J.V.1
Lancaster, G.A.2
Taylor, S.3
-
19
-
-
0021327044
-
Temperature measurement in term and preterm neonates
-
S.R. Mayfield, J. Bhatia, and K.T. Nakamura Temperature measurement in term and preterm neonates J Pediatr 104 1984 271 275
-
(1984)
J Pediatr
, vol.104
, pp. 271-275
-
-
Mayfield, S.R.1
Bhatia, J.2
Nakamura, K.T.3
-
20
-
-
0022759594
-
Axillary and rectal temperatures of full-term neonates: Are they different?
-
B. Haddock, P. Vincent, and D. Merrow Axillary and rectal temperatures of full-term neonates: are they different? Neonatal Netw 5 1986 36 40
-
(1986)
Neonatal Netw
, vol.5
, pp. 36-40
-
-
Haddock, B.1
Vincent, P.2
Merrow, D.3
-
21
-
-
0019017392
-
Oral temperature differences in relation to thermometer and technique
-
R. Erickson Oral temperature differences in relation to thermometer and technique Nurs Res 29 1980 157 164
-
(1980)
Nurs Res
, vol.29
, pp. 157-164
-
-
Erickson, R.1
-
22
-
-
0034728879
-
Temperature measured at the axilla compared with rectum in children and young people: Systematic review
-
J.V. Craig, G.A. Lancaster, P.R. Williamson, and R.L. Smyth Temperature measured at the axilla compared with rectum in children and young people: systematic review BMJ 320 2000 1174 1178
-
(2000)
BMJ
, vol.320
, pp. 1174-1178
-
-
Craig, J.V.1
Lancaster, G.A.2
Williamson, P.R.3
Smyth, R.L.4
|