메뉴 건너뛰기




Volumn 13, Issue 2, 2000, Pages 59-64

Temperature taking in the ICU: which route is best?

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BODY TEMPERATURE; CLINICAL NURSING RESEARCH; CLINICAL TRIAL; COMPARATIVE STUDY; HUMAN; INTENSIVE CARE; METHODOLOGY; THERMOMETER;

EID: 0034189095     PISSN: 10367314     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1036-7314(00)70623-0     Document Type: Article
Times cited : (6)

References (18)
  • 1
    • 0023919481 scopus 로고
    • Infrared tympanic thermometer: evaluation of a new clinical thermometer
    • Shinozuki T., Deane R., and Perkins F. Infrared tympanic thermometer: evaluation of a new clinical thermometer. Critical Care Medicine 16 (1988) 148-150
    • (1988) Critical Care Medicine , vol.16 , pp. 148-150
    • Shinozuki, T.1    Deane, R.2    Perkins, F.3
  • 5
    • 0026180408 scopus 로고
    • A comparison of tympanic and pulmonary artery measures of core temperature
    • Ferrara-Love R. A comparison of tympanic and pulmonary artery measures of core temperature. Journal of Post Anaesthesia Nursing 6 3 (1991) 161-164
    • (1991) Journal of Post Anaesthesia Nursing , vol.6 , Issue.3 , pp. 161-164
    • Ferrara-Love, R.1
  • 6
    • 0026305913 scopus 로고
    • Axillary, tympanic and esophageal temperature measurement: descriptive comparisons in postanesthesia patients
    • Summers S. Axillary, tympanic and esophageal temperature measurement: descriptive comparisons in postanesthesia patients. Journal of Post Anesthesia Nursing 6 6 (1991) 420-425
    • (1991) Journal of Post Anesthesia Nursing , vol.6 , Issue.6 , pp. 420-425
    • Summers, S.1
  • 7
    • 0030078363 scopus 로고    scopus 로고
    • Temperature measurement: why and how in intensive care
    • Bartlett E. Temperature measurement: why and how in intensive care. Intensive and Critical Care Nursing 12 (1996) 50-54
    • (1996) Intensive and Critical Care Nursing , vol.12 , pp. 50-54
    • Bartlett, E.1
  • 8
    • 0027655208 scopus 로고
    • Core temperature measurement in adults: literature review
    • Fulbrook P. Core temperature measurement in adults: literature review. Journal of Advanced Nursing 18 (1993) 1451-1460
    • (1993) Journal of Advanced Nursing , vol.18 , pp. 1451-1460
    • Fulbrook, P.1
  • 9
    • 0026129737 scopus 로고
    • Comparison of tympanic and oral temperatures in surgical patients
    • Erickson R., and Yount S. Comparison of tympanic and oral temperatures in surgical patients. Nursing Research 40 2 (1991) 90-93
    • (1991) Nursing Research , vol.40 , Issue.2 , pp. 90-93
    • Erickson, R.1    Yount, S.2
  • 10
    • 0025298813 scopus 로고
    • Postoperative temperature measurement
    • Heidenreich T., and Guiffre M. Postoperative temperature measurement. Nursing Research 39 (1990) 153-155
    • (1990) Nursing Research , vol.39 , pp. 153-155
    • Heidenreich, T.1    Guiffre, M.2
  • 11
    • 0029339592 scopus 로고
    • A comparison of five methods of temperature measurement in febrile intensive care patients
    • Schmitz T., Blair N., Falk M., and Levine C. A comparison of five methods of temperature measurement in febrile intensive care patients. American Journal of Critical Care 4 4 (1995) 286-292
    • (1995) American Journal of Critical Care , vol.4 , Issue.4 , pp. 286-292
    • Schmitz, T.1    Blair, N.2    Falk, M.3    Levine, C.4
  • 12
    • 0028120250 scopus 로고
    • Accuracy of infrared ear thermometry and other temperatures in adults
    • Erickson R., and Meyer L. Accuracy of infrared ear thermometry and other temperatures in adults. American Journal of Critical Care 3 1 (1994) 40-54
    • (1994) American Journal of Critical Care , vol.3 , Issue.1 , pp. 40-54
    • Erickson, R.1    Meyer, L.2
  • 13
    • 0027490828 scopus 로고
    • A comparison of pulmonary artery, rectal and tympanic membrane temperature measurement in the ICU
    • Klein D., Mitchell C., Petrinec A., Munroe M., Oblak M., and Youngblut J. A comparison of pulmonary artery, rectal and tympanic membrane temperature measurement in the ICU. Heart & Lung 22 5 (1993) 435-441
    • (1993) Heart & Lung , vol.22 , Issue.5 , pp. 435-441
    • Klein, D.1    Mitchell, C.2    Petrinec, A.3    Munroe, M.4    Oblak, M.5    Youngblut, J.6
  • 14
    • 0031201364 scopus 로고    scopus 로고
    • Alternatives to mercury thermometers
    • Toole S. Alternatives to mercury thermometers. Professional Nurse 12 11 (1997) 783-786
    • (1997) Professional Nurse , vol.12 , Issue.11 , pp. 783-786
    • Toole, S.1
  • 15
    • 0024508550 scopus 로고
    • Urinary bladder and rectal temperature monitoring during clinical hypothermia
    • Mravinac C., Dracup K., and Clochesy J. Urinary bladder and rectal temperature monitoring during clinical hypothermia. Nursing Research 38 2 (1989) 435-444
    • (1989) Nursing Research , vol.38 , Issue.2 , pp. 435-444
    • Mravinac, C.1    Dracup, K.2    Clochesy, J.3
  • 17
    • 0028539426 scopus 로고
    • A comparison of tympanic thermometer readings to pulmonary artery catheter core temperature recordings
    • White N., Baird S., and Anderson D. A comparison of tympanic thermometer readings to pulmonary artery catheter core temperature recordings. Applied Nursing Research 7 4 (1994) 165-169
    • (1994) Applied Nursing Research , vol.7 , Issue.4 , pp. 165-169
    • White, N.1    Baird, S.2    Anderson, D.3
  • 18
    • 0002126850 scopus 로고
    • Group factors in worker productivity
    • Probansky H., and Seidenberg B. (Eds), Holt, Rheinhart and Wilson, New York
    • Homans G. Group factors in worker productivity. In: Probansky H., and Seidenberg B. (Eds). Basic studies in social psychology (1965), Holt, Rheinhart and Wilson, New York 592-604
    • (1965) Basic studies in social psychology , pp. 592-604
    • Homans, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.