메뉴 건너뛰기




Volumn 23, Issue 1, 1997, Pages 100-105

Accuracy of infrared ear thermometry in adult patients

Author keywords

Accuracy; Agreement; Ear thermometry; Evaluation; Temperature measurement

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTERY CATHETER; ARTICLE; CORE TEMPERATURE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EARDRUM; ESOPHAGUS; FEMALE; FEVER; HUMAN; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PULMONARY ARTERY; RECTUM TEMPERATURE; REFERENCE VALUE; TEMPERATURE MEASUREMENT; THERMISTOR; THERMOGRAPHY; THERMOMETER;

EID: 0031013838     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001340050297     Document Type: Article
Times cited : (91)

References (28)
  • 1
    • 0026463709 scopus 로고
    • Core temperature measured in the auricular canal: Comparison between four different tympanic thermometers
    • Jakobsson J, Nilsson A, Carlsson L (1992) Core temperature measured in the auricular canal: comparison between four different tympanic thermometers. Acta Anaesthesiol Scand 36:819-824
    • (1992) Acta Anaesthesiol Scand , vol.36 , pp. 819-824
    • Jakobsson, J.1    Nilsson, A.2    Carlsson, L.3
  • 2
    • 0025298813 scopus 로고
    • Postoperative temperature measurement
    • Heidenreich T, Giuffre M (1990) Postoperative temperature measurement. Nurs Res 39:153-155
    • (1990) Nurs Res , vol.39 , pp. 153-155
    • Heidenreich, T.1    Giuffre, M.2
  • 3
    • 0014550152 scopus 로고
    • Tympanic thermometry in surgery and anesthesia
    • Benzinger M (1969) Tympanic thermometry in surgery and anesthesia. JAMA 209:1207-1211
    • (1969) JAMA , vol.209 , pp. 1207-1211
    • Benzinger, M.1
  • 4
    • 0016210639 scopus 로고
    • Studies during open-heart surgery on the special characteristics of rectal temperature
    • Molnar GW, Read RC (1974) Studies during open-heart surgery on the special characteristics of rectal temperature. J Appl Physiol 36:333-336
    • (1974) J Appl Physiol , vol.36 , pp. 333-336
    • Molnar, G.W.1    Read, R.C.2
  • 5
    • 0015659952 scopus 로고
    • Comparison of esophageal and tympanic temperature during cardiopulmonary bypass
    • Webb GE (1973) Comparison of esophageal and tympanic temperature during cardiopulmonary bypass. Anesth Analg 52:729-733
    • (1973) Anesth Analg , vol.52 , pp. 729-733
    • Webb, G.E.1
  • 6
    • 0020567570 scopus 로고
    • Effect of tachypnea on the estimation of body temperature by an oral thermometer
    • Tandberg D, Sklar D (1983) Effect of tachypnea on the estimation of body temperature by an oral thermometer. N Engl J Med 308:945-946
    • (1983) N Engl J Med , vol.308 , pp. 945-946
    • Tandberg, D.1    Sklar, D.2
  • 7
    • 0024441929 scopus 로고
    • Evaluation of a tympanic membrane thermometer in an outpatient clinical setting
    • Ros SP (1989) Evaluation of a tympanic membrane thermometer in an outpatient clinical setting. Ann Emerg Med 18:1004-1006
    • (1989) Ann Emerg Med , vol.18 , pp. 1004-1006
    • Ros, S.P.1
  • 8
    • 0025844810 scopus 로고
    • Comparison of a tympanic thermometer to rectal and oral thermometers in a pediatric emergency department
    • Chamberlain JM, Grandner J, Rubinoff JL, Klein BL, Waisman Y, Huey M (1991) Comparison of a tympanic thermometer to rectal and oral thermometers in a pediatric emergency department. Clin Pediatr 30 [Suppl 4]:24-29
    • (1991) Clin Pediatr , vol.30 , Issue.4 SUPPL. , pp. 24-29
    • Chamberlain, J.M.1    Grandner, J.2    Rubinoff, J.L.3    Klein, B.L.4    Waisman, Y.5    Huey, M.6
  • 9
    • 0026434137 scopus 로고
    • Infrarød tympanisk termografi. Sammenligning av kroppstemperaturmåling rektalt og fra trommehinnen
    • Larsen M, Kaspersen AF (1991) Infrarød tympanisk termografi. Sammenligning av kroppstemperaturmåling rektalt og fra trommehinnen. Tidsskr Nor Lægeforen 111:2542-2543
    • (1991) Tidsskr Nor Lægeforen , vol.111 , pp. 2542-2543
    • Larsen, M.1    Kaspersen, A.F.2
  • 10
    • 0023919481 scopus 로고
    • Infrared tympanic thermometer: Evaluation of a new clinical thermometer
    • Shinozaki T, Deane R, Perkins FM (1988) Infrared tympanic thermometer: evaluation of a new clinical thermometer. Crit Care Med 18:148-150
    • (1988) Crit Care Med , vol.18 , pp. 148-150
    • Shinozaki, T.1    Deane, R.2    Perkins, F.M.3
  • 12
    • 0026532732 scopus 로고
    • Re-evaluation of the tympanic thermometer in the emergency department
    • Stewart JV, Webster D (1992) Re-evaluation of the tympanic thermometer in the emergency department. Ann Emerg Med 21:158-161
    • (1992) Ann Emerg Med , vol.21 , pp. 158-161
    • Stewart, J.V.1    Webster, D.2
  • 13
    • 0026570755 scopus 로고
    • Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting
    • Freed GL, Fraley JK (1992) Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting. Pediatrics 89:384-386
    • (1992) Pediatrics , vol.89 , pp. 384-386
    • Freed, G.L.1    Fraley, J.K.2
  • 15
    • 0028276301 scopus 로고
    • Accuracy of infrared ear thermometry and traditional temperature methods in young children
    • Erickson RS, Woo TM (1994) Accuracy of infrared ear thermometry and traditional temperature methods in young children. Heart Lung 23:181-195
    • (1994) Heart Lung , vol.23 , pp. 181-195
    • Erickson, R.S.1    Woo, T.M.2
  • 16
    • 0028887640 scopus 로고
    • Reliability of infrared tympanic thermometry in the detection of rectal fever in children
    • Brennan DF, Falk JL, Rothrock SG, Kerr RB (1995) Reliability of infrared tympanic thermometry in the detection of rectal fever in children. Ann Emerg Med 25:21-30
    • (1995) Ann Emerg Med , vol.25 , pp. 21-30
    • Brennan, D.F.1    Falk, J.L.2    Rothrock, S.G.3    Kerr, R.B.4
  • 18
    • 0028854447 scopus 로고
    • What's hot and what's not: The gold standard for thermometry in emergency medicine
    • Jaffe DM (1995) What's hot and what's not: the gold standard for thermometry in emergency medicine. Ann Emerg Med 25:97-99
    • (1995) Ann Emerg Med , vol.25 , pp. 97-99
    • Jaffe, D.M.1
  • 19
    • 0027487285 scopus 로고
    • Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement
    • Erickson RS, Kirklin SK (1993) Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement. Crit Care Med 21:1528-1534
    • (1993) Crit Care Med , vol.21 , pp. 1528-1534
    • Erickson, R.S.1    Kirklin, S.K.2
  • 20
    • 0026478011 scopus 로고
    • An appraisal of temperature assessment by infrared emission detection tympanic thermometry
    • Terndrup TE (1992) An appraisal of temperature assessment by infrared emission detection tympanic thermometry. Ann Emerg Med 21:1483-1492
    • (1992) Ann Emerg Med , vol.21 , pp. 1483-1492
    • Terndrup, T.E.1
  • 22
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM (1983) Measurement in medicine: the analysis of method comparison studies. Statistician 32:307-317
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 23
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0025770953 scopus 로고
    • Core temperature measurement in the intensive care unit
    • Nierman DM (1991) Core temperature measurement in the intensive care unit. Crit Care Med 19:818-823
    • (1991) Crit Care Med , vol.19 , pp. 818-823
    • Nierman, D.M.1
  • 26
    • 0028120250 scopus 로고
    • Accuracy of infrared ear thermometry and other temperature methods in adults
    • Erickson RS, Meyer LT (1994) Accuracy of infrared ear thermometry and other temperature methods in adults. Am J Crit Care 3:40-54
    • (1994) Am J Crit Care , vol.3 , pp. 40-54
    • Erickson, R.S.1    Meyer, L.T.2
  • 27
    • 0025905812 scopus 로고
    • The performance of two tympanic thermometers in a pediatric emergency department
    • Terndrup TE, Milewski A (1991) The performance of two tympanic thermometers in a pediatric emergency department. Clin Pediatr 30 [Suppl 4]: 18-23
    • (1991) Clin Pediatr , vol.30 , Issue.4 SUPPL. , pp. 18-23
    • Terndrup, T.E.1    Milewski, A.2
  • 28
    • 0025872699 scopus 로고
    • The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures
    • Zehner WJ, Terndrup TE (1991) The impact of moderate ambient temperature variance on the relationship between oral, rectal, and tympanic membrane temperatures. Clin Pediatr 30 [Suppl 4]:61-64
    • (1991) Clin Pediatr , vol.30 , Issue.4 SUPPL. , pp. 61-64
    • Zehner, W.J.1    Terndrup, T.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.