메뉴 건너뛰기




Volumn 18, Issue 3-4, 2004, Pages 305-312

Impact of standardization on clinical cell analysis by flow cytometry

Author keywords

CD34+ stem cells; CD4+ T cells; Flow cytometry; HLA B27 screening; Leukemia lymphoma immunophenotyping; Standardization

Indexed keywords

CD34 ANTIGEN; CD4 ANTIGEN; HLA B27 ANTIGEN;

EID: 17844383935     PISSN: 0393974X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (15)

References (62)
  • 1
    • 0021602942 scopus 로고
    • The clusters of differentiation (CD) defined by the First International Workshop on Human Leucocyte Differentiation Antigens
    • Bernard A, Boumsell L. The clusters of differentiation (CD) defined by the First International Workshop on Human Leucocyte Differentiation Antigens. Hum Immunol 1984; 11: 1-10.
    • (1984) Hum. Immunol. , vol.11 , pp. 1-10
    • Bernard, A.1    Boumsell, L.2
  • 2
    • 0035046102 scopus 로고    scopus 로고
    • Flow cytometric enumeration and immunophenotyping of hematopoietic stem and progenitor cells
    • Gratama JW, Sutherland DR, Keeney M. Flow cytometric enumeration and immunophenotyping of hematopoietic stem and progenitor cells. Sem Hematol 2001; 38: 139-47.
    • (2001) Sem. Hematol. , vol.38 , pp. 139-147
    • Gratama, J.W.1    Sutherland, D.R.2    Keeney, M.3
  • 4
    • 19444382732 scopus 로고    scopus 로고
    • Clinical applications of flow cytometry: Quality assurance and immunophenotyping of lymphocytes; approved guidelines
    • National Committee for Clinical Laboratory Standards. NCCLS document H42-A2 [ISBN 1-56238-000-0]. NCCLS, Wayne, PA
    • National Committee for Clinical Laboratory Standards. Clinical applications of flow cytometry: Quality assurance and immunophenotyping of lymphocytes; approved guidelines. NCCLS document H42-A2 [ISBN 1-56238-000-0]. NCCLS, Wayne, PA, 2004.
    • (2004)
  • 5
    • 6844249429 scopus 로고    scopus 로고
    • + T lymphocytes in immunosuppressed individuals
    • for and on behalf of the General Haematology Task Force of BCSH
    • + T lymphocytes in immunosuppressed individuals. Clin Lab Haematol 1997; 19: 231-41.
    • (1997) Clin. Lab. Haematol. , vol.19 , pp. 231-241
    • Barnett, D.1    Bird, G.2    Hodges, E.3
  • 6
    • 0037474317 scopus 로고    scopus 로고
    • + T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus
    • Centers for Disease Control and Prevention (RR-2)
    • + T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus. MMWR Recomm Rep 2003; 52 (RR-2): 1-13.
    • (2003) MMWR Recomm. Rep. , vol.52 , pp. 1-13
    • Mandy, F.F.1    Nicholson, J.K.2    McDougal, J.S.3
  • 7
    • 0027375009 scopus 로고
    • Guidelines for flow cytometric immunophenotyping: A report from the National Institute of Allergy and Infectious Diseases, Division of AIDS
    • Calvelli T, Denny TN, Paxton H, Gelman R, Kagan J. Guidelines for flow cytometric immunophenotyping: A report from the National Institute of Allergy and Infectious Diseases, Division of AIDS. Cytometry 1993; 14: 702-15.
    • (1993) Cytometry , vol.14 , pp. 702-715
    • Calvelli, T.1    Denny, T.N.2    Paxton, H.3    Gelman, R.4    Kagan, J.5
  • 8
    • 0008272617 scopus 로고    scopus 로고
    • Clinical applications of flow cytometry: Immunophenotyping of leukemic cells; approved guidelines
    • National Committee for Clinical Laboratory Standards. NCCLS document H43-A [ISBN 1-56238-351-5]. NCCLS, Wayne, PA
    • National Committee for Clinical Laboratory Standards. Clinical applications of flow cytometry: Immunophenotyping of leukemic cells; approved guidelines. NCCLS document H43-A [ISBN 1-56238-351-5]. NCCLS, Wayne, PA, 1998.
    • (1998)
  • 9
    • 0032977442 scopus 로고    scopus 로고
    • Belgian consensus recommendations for flow cytometric immunophenotyping
    • for the Belgian Association for Cytometry/Belgische Vereniging voor Cytometrie/Association Belge de Cytometrie
    • Van Bockstaele DR, Deneys V, Philippe J, et al, for the Belgian Association for Cytometry/Belgische Vereniging voor Cytometrie/Association Belge de Cytometrie. Belgian consensus recommendations for flow cytometric immunophenotyping. Acta Clin Belg 1999; 54: 88-98.
    • (1999) Acta Clin. Belg. , vol.54 , pp. 88-98
    • Van Bockstaele, D.R.1    Deneys, V.2    Philippe, J.3
  • 10
    • 0029934173 scopus 로고    scopus 로고
    • Consensus protocol for the flow cytometric immunophenotyping of hematopoietic malignancies
    • for the Working Group on Flow Cytometry and Image Analysis
    • Rothe G, Schmitz G, for the Working Group on Flow Cytometry and Image Analysis. Consensus protocol for the flow cytometric immunophenotyping of hematopoietic malignancies. Leukemia 1996; 10: 877-95.
    • (1996) Leukemia , vol.10 , pp. 877-895
    • Rothe, G.1    Schmitz, G.2
  • 11
    • 0028837561 scopus 로고
    • Proposals for the immunological classification of acute leukemias
    • for the European Group for the Immunological Characterization of Leukemias (EGIL)
    • Bené MC, Castoldi G, Knapp W, et al for the European Group for the Immunological Characterization of Leukemias (EGIL). Proposals for the immunological classification of acute leukemias. Leukemia 1995; 9: 1783-6.
    • (1995) Leukemia , vol.9 , pp. 1783-1786
    • Bené, M.C.1    Castoldi, G.2    Knapp, W.3
  • 12
    • 85016364103 scopus 로고    scopus 로고
    • Website of the Foundation for Immunophenotyping in Hemato-Oncology in The Netherlands (SIHON)
    • Website of the Foundation for Immunophenotyping in Hemato-Oncology in The Netherlands (SIHON): http://www.sihon.nl/protocollen.
  • 13
    • 0029100164 scopus 로고
    • + cell analysis: Technical recommendations for progenitor cell enumeration in leukapheresis from multiple myeloma patients
    • for the Nordic Myeloma Study Group Laboratories
    • + cell analysis: Technical recommendations for progenitor cell enumeration in leukapheresis from multiple myeloma patients. J Hematother 1995; 4: 21-8.
    • (1995) J. Hematother. , vol.4 , pp. 21-28
    • Johnsen, H.E.1
  • 15
    • 0032715668 scopus 로고    scopus 로고
    • Semi-automated flow cytometric analysis of CD34-expressing hematopoietic cells in peripheral blood progenitor cell apheresis products
    • Gutensohn K, Carrero I, Krueger W, Kroeger N, Schafer P, Luedemann K, Kuehnl P. Semi-automated flow cytometric analysis of CD34-expressing hematopoietic cells in peripheral blood progenitor cell apheresis products. Transfusion 1999; 39: 1220-6.
    • (1999) Transfusion , vol.39 , pp. 1220-1226
    • Gutensohn, K.1    Carrero, I.2    Krueger, W.3    Kroeger, N.4    Schafer, P.5    Luedemann, K.6    Kuehnl, P.7
  • 18
    • 0033836380 scopus 로고    scopus 로고
    • Proposed flow cytometric reference method for the determination of erythroid F-cell counts
    • Chen JC, Bigelow N, Davis BH. Proposed flow cytometric reference method for the determination of erythroid F-cell counts. Cytometry 2000; 42: 239-46.
    • (2000) Cytometry , vol.42 , pp. 239-246
    • Chen, J.C.1    Bigelow, N.2    Davis, B.H.3
  • 19
    • 0035290712 scopus 로고    scopus 로고
    • Platelet counting by the RBC/platelet ratio method: A reference method
    • International Council for Standardization in Hematology Expert Panel on Cytometry; International Society of Laboratory Hematology Task Force on Platelet Counting
    • International Council for Standardization in Hematology Expert Panel on Cytometry; International Society of Laboratory Hematology Task Force on Platelet Counting. Platelet counting by the RBC/platelet ratio method: A reference method. Am J Clin Pathol 2001; 115: 460-4.
    • (2001) Am. J. Clin. Pathol. , vol.115 , pp. 460-464
  • 20
    • 0036593725 scopus 로고    scopus 로고
    • The United Kingdom National External Quality Assessment Scheme gating and standardization strategy for use in residual WBC counting of WBC-reduced blood components
    • Goodfellow KJ, Storie I, Granger V, Whitby L, Antcliffe J, Reilly JT, Barnett D. The United Kingdom National External Quality Assessment Scheme gating and standardization strategy for use in residual WBC counting of WBC-reduced blood components. Transfusion 2002; 42: 738-46.
    • (2002) Transfusion , vol.42 , pp. 738-746
    • Goodfellow, K.J.1    Storie, I.2    Granger, V.3    Whitby, L.4    Antcliffe, J.5    Reilly, J.T.6    Barnett, D.7
  • 22
    • 0025278511 scopus 로고
    • Establishing optimal lymphocyte gates for immunophenotyping by flow cytometry
    • Loken MR, Brosnan JM, Bach BA, Ault KA. Establishing optimal lymphocyte gates for immunophenotyping by flow cytometry. Cytometry 1990; 11: 453-9.
    • (1990) Cytometry , vol.11 , pp. 453-459
    • Loken, M.R.1    Brosnan, J.M.2    Bach, B.A.3    Ault, K.A.4
  • 23
    • 0034671209 scopus 로고    scopus 로고
    • Cytofluorometric methods for assessing absolute numbers of cell subsets in blood
    • for the European Working Group on Clinical Cell Analysis (EWGCCA)
    • Brando B, Barnett D, Janossy G, et al, for the European Working Group on Clinical Cell Analysis (EWGCCA). Cytofluorometric methods for assessing absolute numbers of cell subsets in blood. Cytometry 2000; 42: 327-46.
    • (2000) Cytometry , vol.42 , pp. 327-346
    • Brando, B.1    Barnett, D.2    Janossy, G.3
  • 24
    • 0027115003 scopus 로고
    • + T-cell determinations in persons with human immunodeficiency virus infection
    • Centers for Disease Control and Prevention. (RR-8)
    • + T-cell determinations in persons with human immunodeficiency virus infection. MMWR Recomm Rep 1992; 41 (RR-8): 1-17.
    • (1992) MMWR Recomm. Rep. , vol.41 , pp. 1-17
  • 25
    • 0027071866 scopus 로고
    • A simultaneous three-color T cell subsets analysis with single laser flow cytometers using T cell gating protocol
    • Mandy FF, Bergeron M, Recktenwald D, Izaguirre C. A simultaneous three-color T cell subsets analysis with single laser flow cytometers using T cell gating protocol. J Immunol Meth 1992; 156: 151-62.
    • (1992) J. Immunol. Meth. , vol.156 , pp. 151-162
    • Mandy, F.F.1    Bergeron, M.2    Recktenwald, D.3    Izaguirre, C.4
  • 26
    • 0027200842 scopus 로고
    • CD4 T-lymphocyte determinations on whole blood specimens using a single-tube three-color assay
    • Nicholson JKA, Jones BM, Hubbard M. CD4 T-lymphocyte determinations on whole blood specimens using a single-tube three-color assay. Cytometry 1993; 14: 685-9.
    • (1993) Cytometry , vol.14 , pp. 685-689
    • Nicholson, J.K.A.1    Jones, B.M.2    Hubbard, M.3
  • 27
    • 0032189956 scopus 로고    scopus 로고
    • Impact of unified procedures as implemented in the Canadian quality assurance program for T lymphocyte subset enumeration
    • and the Participating Flow Cytometry Laboratories of the Canadian Clinical Trials Network for HIV/AIDS Therapies
    • Bergeron M, Faucher S, Minkus T, et al, and the Participating Flow Cytometry Laboratories of the Canadian Clinical Trials Network for HIV/AIDS Therapies. Impact of unified procedures as implemented in the Canadian quality assurance program for T lymphocyte subset enumeration. Cytometry 1998; 33: 146-55.
    • (1998) Cytometry , vol.33 , pp. 146-155
    • Bergeron, M.1    Faucher, S.2    Minkus, T.3
  • 28
    • 0029874250 scopus 로고    scopus 로고
    • Use of CD45 fluorescence and side-scatter characteristics for gating lymphocytes when using the whole blood lysis procedure and flow cytometry
    • Nicholson JKA, Hubbard M, Jones BM. Use of CD45 fluorescence and side-scatter characteristics for gating lymphocytes when using the whole blood lysis procedure and flow cytometry. Cytometry 1996; 26: 16-21.
    • (1996) Cytometry , vol.26 , pp. 16-21
    • Nicholson, J.K.A.1    Hubbard, M.2    Jones, B.M.3
  • 29
    • 0031561537 scopus 로고    scopus 로고
    • 1997 revised guidelines for performing CD4+ T-cell determinations in persons infected with human immunodeficiency virus (HIV)
    • Centers for Disease Control and Prevention (CDC). (RR-2)
    • Centers for Disease Control and Prevention (CDC). 1997 revised guidelines for performing CD4+ T-cell determinations in persons infected with human immunodeficiency virus (HIV). MMWR Recomm Rep 1997 (RR-2); 46: 1-29.
    • (1997) MMWR Recomm. Rep. , vol.46 , pp. 1-29
  • 30
    • 0029849287 scopus 로고    scopus 로고
    • Three-color supplement to the NIAID DAIDS guideline for flow cytometric immunophenotyping
    • Nicholson J, Kidd P, Mandy F, Livnat D, Kagan J. Three-color supplement to the NIAID DAIDS guideline for flow cytometric immunophenotyping. Cytometry 1996; 26: 227-30.
    • (1996) Cytometry , vol.26 , pp. 227-230
    • Nicholson, J.1    Kidd, P.2    Mandy, F.3    Livnat, D.4    Kagan, J.5
  • 31
    • 0028866482 scopus 로고
    • + lymphocyte counts across laboratories: An evaluation of the Ortho Cytoron-Absolute flow cytometry system on normal donors
    • + lymphocyte counts across laboratories: An evaluation of the Ortho Cytoron-Absolute flow cytometry system on normal donors. Cytometry 1995; 22: 200-10.
    • (1995) Cytometry , vol.22 , pp. 200-210
    • Connelly, M.C.1    Knight, M.2    Giorgi, J.V.3
  • 33
    • 0032211164 scopus 로고    scopus 로고
    • Evaluation of a flow cytometric method for simultaneous leukocyte phenotyping and quantification by fluorescent microspheres
    • Schlenke P, Frohn C, Klueter H, et al. Evaluation of a flow cytometric method for simultaneous leukocyte phenotyping and quantification by fluorescent microspheres. Cytometry 1998; 33: 310-7.
    • (1998) Cytometry , vol.33 , pp. 310-317
    • Schlenke, P.1    Frohn, C.2    Klueter, H.3
  • 34
    • 0034062712 scopus 로고    scopus 로고
    • Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults
    • Site Investigators, and the NIAID DAIDS New Technologies Evaluation Group
    • Schnizlein-Bick CT, Spritzler J, Wilkening CL, Nicholson JKA, O'Gorman MRG, Site Investigators, and the NIAID DAIDS New Technologies Evaluation Group. Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults. Clin Diagn Lab Immunol 2000; 7: 336-43.
    • (2000) Clin. Diagn. Lab. Immunol. , vol.7 , pp. 336-343
    • Schnizlein-Bick, C.T.1    Spritzler, J.2    Wilkening, C.L.3    Nicholson, J.K.A.4    O'Gorman, M.R.G.5
  • 35
    • 0034020628 scopus 로고    scopus 로고
    • Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: Evaluation of Beckman Coulter Flow-Count fluorospheres and the tetraONE system
    • and the NIAID DAIDS New Technologies Evaluation Group
    • Reimann KA, O'Gorman MRG, Spritzler J, et al, and the NIAID DAIDS New Technologies Evaluation Group. Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: Evaluation of Beckman Coulter Flow-Count fluorospheres and the tetraONE system. Clin Diagn Lab Immunol 2000; 7: 344-51.
    • (2000) Clin. Diagn. Lab. Immunol. , vol.7 , pp. 344-351
    • Reimann, K.A.1    O'Gorman, M.R.G.2    Spritzler, J.3
  • 36
    • 0037092125 scopus 로고    scopus 로고
    • Quality control of CD4+ T-lymphocyte enumeration: Results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993-2001)
    • Whitby L, Granger V, Storie I, et al. Quality control of CD4+ T-lymphocyte enumeration: Results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993-2001). Cytometry 2002; 50: 102-10.
    • (2002) Cytometry , vol.50 , pp. 102-110
    • Whitby, L.1    Granger, V.2    Storie, I.3
  • 37
    • 0037092124 scopus 로고    scopus 로고
    • Reduction of variation in T-cell subset enumeration among 55 laboratories using single-platform, three or four-color flow cytometry based on CD45 and SSC-based gating of lymphocytes
    • Gratama JW, Kraan J, Keeney M, Granger V, Barnett D. Reduction of variation in T-cell subset enumeration among 55 laboratories using single-platform, three or four-color flow cytometry based on CD45 and SSC-based gating of lymphocytes. Cytometry 2002; 50: 92-101.
    • (2002) Cytometry , vol.50 , pp. 92-101
    • Gratama, J.W.1    Kraan, J.2    Keeney, M.3    Granger, V.4    Barnett, D.5
  • 38
    • 0037092072 scopus 로고    scopus 로고
    • Impact of the international program for Quality Assessment and Standardization for Immunological Measures Relevant to HIV/AIDS: QASI
    • Mandy F, Bergeron M, Houle G, Bradley J, Fahey J. Impact of the international program for Quality Assessment and Standardization for Immunological Measures Relevant to HIV/AIDS: QASI. Cytometry 2002; 50: 111-6.
    • (2002) Cytometry , vol.50 , pp. 111-116
    • Mandy, F.1    Bergeron, M.2    Houle, G.3    Bradley, J.4    Fahey, J.5
  • 39
    • 0037092123 scopus 로고    scopus 로고
    • CD45-assisted PanLeuco-gating for accurate, cost-effective dual-platform CD4+T-cell enumeration
    • Glencross D, Scott LE, Jani IV, Barnett D, Janossy G. CD45-assisted PanLeuco-gating for accurate, cost-effective dual-platform CD4+T-cell enumeration. Cytometry 2002; 50: 69-77.
    • (2002) Cytometry , vol.50 , pp. 69-77
    • Glencross, D.1    Scott, L.E.2    Jani, I.V.3    Barnett, D.4    Janossy, G.5
  • 40
    • 0024439774 scopus 로고
    • + hematopoietic stem cells in the peripheral blood of high-dose cyclophosphamide-treated patients: Enhancement by intravenous recombinant human granulocyte-macrophage colony-stimulating factor
    • + hematopoietic stem cells in the peripheral blood of high-dose cyclophosphamide-treated patients: Enhancement by intravenous recombinant human granulocyte-macrophage colony-stimulating factor. Blood 1989; 74: 1905-1914.
    • (1989) Blood , vol.74 , pp. 1905-1914
    • Siena, S.1    Bregni, M.2    Brando, B.3    Ravagnani, F.4    Bonadonna, G.5    Gianni, A.M.6
  • 41
    • 0025980856 scopus 로고
    • Flow cytometry for clinical estimation of circulating hematopoietic progenitors for autologous transplantation in cancer patients
    • Siena S, Bregni M, Brando B, et al. Flow cytometry for clinical estimation of circulating hematopoietic progenitors for autologous transplantation in cancer patients. Blood 1991; 77: 400-9.
    • (1991) Blood , vol.77 , pp. 400-409
    • Siena, S.1    Bregni, M.2    Brando, B.3
  • 42
    • 0034998028 scopus 로고    scopus 로고
    • Flow cytometric enumeration and immunophenotyping of hematopoietic stem and progenitor cells
    • Gratama JW, Sutherland DR, Keeney M, Papa S. Flow cytometric enumeration and immunophenotyping of hematopoietic stem and progenitor cells. J Biol Reg Homeostat Agents 2001; 15: 14-22.
    • (2001) J. Biol. Reg. Homeostat. Agents , vol.15 , pp. 14-22
    • Gratama, J.W.1    Sutherland, D.R.2    Keeney, M.3    Papa, S.4
  • 44
    • 0036330398 scopus 로고    scopus 로고
    • Number of viable CD34(+) cells reinfused predicts engraftment in autologous hematopoietic stem cell transplantation
    • Allan DS, Keeney M, Howson-Jan K, et al. Number of viable CD34(+) cells reinfused predicts engraftment in autologous hematopoietic stem cell transplantation. Bone Marrow Transplant 2002; 29: 967-72.
    • (2002) Bone Marrow Transplant. , vol.29 , pp. 967-972
    • Allan, D.S.1    Keeney, M.2    Howson-Jan, K.3
  • 45
    • 0034026944 scopus 로고    scopus 로고
    • + stem cell enumeration using stable test material, standard protocols and targeted training
    • for the CD34 Task Force of the European Working Group of Clinical Cell Analysis (EWGCCA)
    • + stem cell enumeration using stable test material, standard protocols and targeted training. Br J Haematol 2000; 108: 784-92.
    • (2000) Br. J. Haematol. , vol.108 , pp. 784-792
    • Barnett, D.1    Granger, V.2    Kraan, J.3
  • 46
    • 0037243426 scopus 로고    scopus 로고
    • Validation of the single-platform ISHAGE method for CD34(+) hematopoietic stem and progenitor cell enumeration in an international multicenter study
    • Gratama JW, Kraan J, Keeney M, Sutherland DR, Granger V, Barnett D. Validation of the single-platform ISHAGE method for CD34(+) hematopoietic stem and progenitor cell enumeration in an international multicenter study. Cytotherapy 2003; 5: 55-65.
    • (2003) Cytotherapy , vol.5 , pp. 55-65
    • Gratama, J.W.1    Kraan, J.2    Keeney, M.3    Sutherland, D.R.4    Granger, V.5    Barnett, D.6
  • 48
    • 0141905528 scopus 로고    scopus 로고
    • Flow cytometric HLA-B27 screening: Crossreactivity patterns of commercially available anti-HLA-B27 monoclonal antibodies with other HLA-B antigens
    • Levering WHBM, Wind H, Sintnicolaas K, Hooijkaas H, Gratama JW. Flow cytometric HLA-B27 screening: Crossreactivity patterns of commercially available anti-HLA-B27 monoclonal antibodies with other HLA-B antigens. Cytometry 2003; 54B: 28-38.
    • (2003) Cytometry , vol.54 B , pp. 28-38
    • Levering, W.H.B.M.1    Wind, H.2    Sintnicolaas, K.3    Hooijkaas, H.4    Gratama, J.W.5
  • 49
    • 0034656145 scopus 로고    scopus 로고
    • External quality assessment of flow cytometric HLA-B27 typing
    • Levering WHBM, Van den Beemd R, Te Marvelde JG, et al. External quality assessment of flow cytometric HLA-B27 typing. Cytometry 2000; 42: 95-105.
    • (2000) Cytometry , vol.42 , pp. 95-105
    • Levering, W.H.B.M.1    Van den Beemd, R.2    Te Marvelde, J.G.3
  • 50
    • 0026561882 scopus 로고
    • Quality assessment of immunological marker analysis and the immunological diagnosis in leukaemia and lymphoma: A multi-centre study
    • Dutch Cooperative Study Group on Immunophenotyping of Leukaemias and Lymphomas (SIHON)
    • Van't Veer MB, Kluin-Nelemans JC, van der Schoot CE, van Putten WL, Adriaansen HJ, van Wering ER. Quality assessment of immunological marker analysis and the immunological diagnosis in leukaemia and lymphoma: A multi-centre study. Dutch Cooperative Study Group on Immunophenotyping of Leukaemias and Lymphomas (SIHON). Br J Haematol 1992; 80: 458-65.
    • (1992) Br. J. Haematol. , vol.80 , pp. 458-465
    • Van't Veer, M.B.1    Kluin-Nelemans, J.C.2    van der Schoot, C.E.3    van Putten, W.L.4    Adriaansen, H.J.5    van Wering, E.R.6
  • 51
    • 0031466392 scopus 로고    scopus 로고
    • Definition of acute biphenotypic leukemia
    • Matutes E, Morilla R, Farahat N, et al. Definition of acute biphenotypic leukemia. Haematologica 1997; 82: 64-6.
    • (1997) Haematologica , vol.82 , pp. 64-66
    • Matutes, E.1    Morilla, R.2    Farahat, N.3
  • 53
    • 0030840151 scopus 로고    scopus 로고
    • U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Standardization and validation of laboratory procedures
    • Stelzer GT, Marti G, Hurley A, McCoy P Jr, Lovett EJ, Schwartz A. U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Standardization and validation of laboratory procedures. Cytometry 1997; 30: 214-230.
    • (1997) Cytometry , vol.30 , pp. 214-230
    • Stelzer, G.T.1    Marti, G.2    Hurley, A.3    McCoy Jr., P.4    Lovett, E.J.5    Schwartz, A.6
  • 54
    • 0004698360 scopus 로고    scopus 로고
    • U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Selection of antibody combinations
    • Stewart CC, Behm FG, Carey JL, et al. U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Selection of antibody combinations. Cytometry 1997; 30: 231-5.
    • (1997) Cytometry , vol.30 , pp. 231-235
    • Stewart, C.C.1    Behm, F.G.2    Carey, J.L.3
  • 55
    • 0030828712 scopus 로고    scopus 로고
    • U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Data analysis and interpretation
    • Borowitz MJ, Bray R, Gascoyne R, et al. U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Data analysis and interpretation. Cytometry 1997; 30: 236-44.
    • (1997) Cytometry , vol.30 , pp. 236-244
    • Borowitz, M.J.1    Bray, R.2    Gascoyne, R.3
  • 56
    • 0030780408 scopus 로고    scopus 로고
    • U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Data reporting
    • Braylan RC, Atwater SK, Diamond L, et al. U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Data reporting. Cytometry 1997; 30: 245-8.
    • (1997) Cytometry , vol.30 , pp. 245-248
    • Braylan, R.C.1    Atwater, S.K.2    Diamond, L.3
  • 57
    • 0345485136 scopus 로고    scopus 로고
    • U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Medical indications
    • Davis BH, Foucar K, Szczarkowski W, et al. U.S.-Canadian Consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: Medical indications. Cytometry 1997; 30: 249-63.
    • (1997) Cytometry , vol.30 , pp. 249-263
    • Davis, B.H.1    Foucar, K.2    Szczarkowski, W.3
  • 58
    • 0030445068 scopus 로고    scopus 로고
    • Pitfalls in the immuno-phenotyping of leukaemia and leukaemic lymphomas: Survey of 9 years of quality control in The Netherlands
    • Dutch Cooperative Study Group on Immuno-phenotyping of Haematological Malignancies (SIHON)
    • Kluin-Nelemans JC, van Wering ER, van'T Veer MB, et al. Pitfalls in the immuno-phenotyping of leukaemia and leukaemic lymphomas: Survey of 9 years of quality control in The Netherlands. Dutch Cooperative Study Group on Immuno-phenotyping of Haematological Malignancies (SIHON). Br J Haematol 1996; 95: 692-9.
    • (1996) Br. J. Haematol. , vol.95 , pp. 692-699
    • Kluin-Nelemans, J.C.1    van Wering, E.R.2    van'T Veer, M.B.3
  • 59
    • 0035120778 scopus 로고    scopus 로고
    • SIHON-SCORE: A scoring system for external quality control of leukaemia/lymphoma immuno-phenotyping measuring all analytical phases of laboratory performance
    • for the Dutch Co-operative Study Group on Immunophenotyping of Haematological Malignancies (SIHON)
    • Kluin-Nelemans J, Van Wering E, Van Der Schoot C, et al. for the Dutch Co-operative Study Group on Immunophenotyping of Haematological Malignancies (SIHON). SIHON-SCORE: A scoring system for external quality control of leukaemia/lymphoma immuno-phenotyping measuring all analytical phases of laboratory performance. Br J Haematol 2001; 112: 337-43.
    • (2001) Br. J. Haematol. , vol.112 , pp. 337-343
    • Kluin-Nelemans, J.1    Van Wering, E.2    Van Der Schoot, C.3
  • 60
    • 9644299068 scopus 로고    scopus 로고
    • Externe kwaliteitsbewaking van flowcyto-metrische immuno-fenotypering
    • Van Lochem EG, Van der Velden VHJ, Hooijkaas H, Van Dongen JJM, eds. Rotterdam, Afdeling Immunologie, Erasmus MC
    • Gratama JW, Van Beers W, Eidhof H, et al. Externe kwaliteitsbewaking van flowcyto-metrische immuno-fenotypering. In: Van Lochem EG, Van der Velden VHJ, Hooijkaas H, Van Dongen JJM, eds. Nieuwe diagnostische toepassingen van flowcytometrie. Rotterdam, Afdeling Immunologie, Erasmus MC; 2003: pp. 223-33.
    • (2003) Nieuwe Diagnostische Toepassingen Van Flowcytometrie , pp. 223-233
    • Gratama, J.W.1    Van Beers, W.2    Eidhof, H.3
  • 61
    • 1242272703 scopus 로고    scopus 로고
    • Diagnosis of plasma cell leukaemia: Findings of the UK NEQAS for Leucocyte Immunophenotyping scheme
    • Van Veen JJ, Reilly JT, Richards SJ, et al. Diagnosis of plasma cell leukaemia: Findings of the UK NEQAS for Leucocyte Immunophenotyping scheme. Clin Lab Haematol 2004; 26: 37-42.
    • (2004) Clin. Lab. Haematol. , vol.26 , pp. 37-42
    • Van Veen, J.J.1    Reilly, J.T.2    Richards, S.J.3
  • 62
    • 2542427561 scopus 로고    scopus 로고
    • Recommended reporting format for flow cytometry diagnosis of acute leukemia
    • Del Vecchio L, Brando B, Lanza F, et al. Recommended reporting format for flow cytometry diagnosis of acute leukemia. Haematologica 2004; 89: 594-8.
    • (2004) Haematologica , vol.89 , pp. 594-598
    • Del Vecchio, L.1    Brando, B.2    Lanza, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.