메뉴 건너뛰기




Volumn 72, Issue 1, 2005, Pages 42-46

Radiological changes around the stem after cementless hip implantation in case of the anatomic medullary locking hip system - Five years results

Author keywords

AML; Stress shielding; Total hip endoprosthesis

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; ELASTICITY; ENDOPROSTHESIS; FEMALE; FEMUR; HUMAN; MAJOR CLINICAL STUDY; MALE; MECHANICAL STRESS; OSTEOPOROSIS; POSTOPERATIVE PERIOD; SURGICAL TECHNIQUE; THIGH; TOTAL HIP PROSTHESIS;

EID: 17644423465     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (31)
  • 1
    • 0000505408 scopus 로고
    • The Radiological Diagnosis of Osteoporosis: A New Approach
    • BARNETT, E., NORDIN, B. E. C.: The Radiological Diagnosis of Osteoporosis: a New Approach. Clin. Radiology, 11: 166-174, 1960.
    • (1960) Clin. Radiology , vol.11 , pp. 166-174
    • Barnett, E.1    Nordin, B.E.C.2
  • 2
    • 0032881417 scopus 로고    scopus 로고
    • The Pathology of Total Joint Arthroplasty II. Mechanisms of Implant Failure
    • BAUER, T. W., SCHILS, J: The Pathology of Total Joint Arthroplasty II. Mechanisms of Implant Failure. Skeletal Radiol., 28: 483-497, 1999.
    • (1999) Skeletal Radiol. , vol.28 , pp. 483-497
    • Bauer, T.W.1    Schils, J.2
  • 3
    • 0026519501 scopus 로고
    • Producing and Avoiding Stress Shielding Laboratory and Clinical Results of Noncemented Total Hip Arthroplasty
    • BOBYN, J. D., MORTIMER, E. S., GLASSMAN, A. H., ENGH, C. A., MILLER, J. E., BROOKS, C. E.: Producing and Avoiding Stress Shielding Laboratory and Clinical Results of Noncemented Total Hip Arthroplasty. Clin. Orthop., 274: 79-96, 1992.
    • (1992) Clin. Orthop. , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3    Engh, C.A.4    Miller, J.E.5    Brooks, C.E.6
  • 4
    • 0030845001 scopus 로고    scopus 로고
    • Long-term Clinical Consequences of Stress-Shielding after Total Hip Arthroplasty without Cement
    • BUGBEE, W. D., CULPEPPER, W. J. 2ND, ENGH, C. A. JR., ENGH, C. A. SR.: Long-term Clinical Consequences of Stress-Shielding after Total Hip Arthroplasty without Cement. J. Bone Jt Surg., 79-A, 1007-1012, 1996.
    • (1996) J. Bone Jt Surg. , vol.79 A , pp. 1007-1012
    • Bugbee, W.D.1    Culpepper II, W.J.2    Engh Jr., C.A.3    Engh Sr., C.A.4
  • 5
    • 0029972210 scopus 로고    scopus 로고
    • Bone Remodeling around Cementless Hip Implants
    • BUGBEE, W. D., SYCHTERZ, C., J., ENGH, C., A.: Bone Remodeling around Cementless Hip Implants. South. Med. J., 89: 1036-1040, 1996.
    • (1996) South Med. J. , vol.89 , pp. 1036-1040
    • Bugbee, W.D.1    Sychterz, C.J.2    Engh, C.A.3
  • 6
    • 0031431404 scopus 로고    scopus 로고
    • Osseointegration & Stress Shielding
    • CAMERON, H., U.: Osseointegration & Stress Shielding. Acta orthop. belg., 63: 8-10, 1997.
    • (1997) Acta Orthop. Belg. , vol.63 , pp. 8-10
    • Cameron, H.U.1
  • 7
    • 0023777583 scopus 로고    scopus 로고
    • The Influence of Stem Size and Extent of Porous Coating on Femoral Bone Remodeling after Primary Cementless Hip Arthroplsty
    • ENGH, C. A., BOBYN, J. D.: The Influence of Stem Size and Extent of Porous Coating on Femoral Bone Remodeling after Primary Cementless Hip Arthroplsty. Clin. Orthop., 231: 7-28, 1998.
    • (1998) Clin. Orthop. , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 8
    • 0023240947 scopus 로고
    • Porous-coated Hip Replacement. The Factors Governing Bone Ingrowth, Stress Shielding, and Clinical Results
    • ENGH, C. A., BOBYN, J. D., GLASSMAN, A. H.: Porous-coated Hip Replacement. The Factors Governing Bone Ingrowth, Stress Shielding, and Clinical Results. J. Bone Jt Surg., 69-B: 45-55, 1987.
    • (1987) J. Bone Jt. Surg. , vol.69 B , pp. 45-55
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 9
    • 0035186245 scopus 로고    scopus 로고
    • Long-term Results Using the Anatomic Medullary Locking Hip Prosthesis
    • ENGH, C. A. Jr., CLAUS, A. M., HOPPER, R. H. Jr., ENGH, C. A.: Long-term Results Using the Anatomic Medullary Locking Hip Prosthesis. Clin. Orthop., 393: 137-146, 2001.
    • (2001) Clin. Orthop. , vol.393 , pp. 137-146
    • Engh Jr., C.A.1    Claus, A.M.2    Hopper Jr., R.H.3    Engh, C.A.4
  • 10
    • 0031226575 scopus 로고    scopus 로고
    • Femoral Fixation in Primary Total Hip Arthroplasty
    • ENGH, C. A. SR., CULPEPPER, W. J. 2ND: Femoral Fixation in Primary Total Hip Arthroplasty. Orthopedics, 20: 771-773, 1997
    • (1997) Orthopedics , vol.20 , pp. 771-773
    • Engh Sr., C.A.1    Culpepper II, W.J.2
  • 11
    • 0036738992 scopus 로고    scopus 로고
    • The Relationship between Lysis and Loosening in Failed Anatomic Medullary Locking Components
    • ENGH, C. A., ENGH, C. A. Jr., CLAUS A.: The Relationship between Lysis and Loosening in Failed Anatomic Medullary Locking Components. Orthopedics, 24: 855-856, 2001.
    • (2001) Orthopedics , vol.24 , pp. 855-856
    • Engh, C.A.1    Engh Jr., C.A.2    Claus, A.3
  • 12
    • 0036080771 scopus 로고    scopus 로고
    • The Odyssey of Porous-Coated Fixation
    • ENGH, C. A., HOPPER, R. H. Jr.: The Odyssey of Porous-Coated Fixation. J. Arthroplasty, 17: 102-107, 2002.
    • (2002) J. Arthroplasty , vol.17 , pp. 102-107
    • Engh, C.A.1    Hopper Jr., R.H.2
  • 13
    • 85166667800 scopus 로고
    • Radiographic Criteria for the Clinical Performance of Uncemented Total Joint Replacements. Quantitative Characterization and Performance of Porous Implants for Hard Tissue Applications
    • J. E. Lemons, Editor, American Society for Testing Materials, Philadelphia, Pennsylvania
    • GRUEN, T. A.: Radiographic Criteria for the Clinical Performance of Uncemented Total Joint Replacements. Quantitative Characterization and Performance of Porous Implants for Hard Tissue Applications, J. E. Lemons, Editor, American Society for Testing Materials, Philadelphia, Pennsylvania, ASTM STP, 1987, Vol. 953, 207-218.
    • (1987) ASTM STP , vol.953 , pp. 207-218
    • Gruen, T.A.1
  • 14
    • 0028813516 scopus 로고
    • Titanium as the Material of Choice for Cementless Femoral Components in Total Hip Arthroplasty
    • HEAD, W. C., BAUK, D. J., EMERSON, R. H. Jr.: Titanium as the Material of Choice for Cementless Femoral Components in Total Hip Arthroplasty. Clin. Orthop., 311: 85-90, 1995.
    • (1995) Clin. Orthop. , vol.311 , pp. 85-90
    • Head, W.C.1    Bauk, D.J.2    Emerson Jr., R.H.3
  • 15
    • 0028877233 scopus 로고
    • Grundlagen der Pauwels-Theorie der funktionellen Anpassung des Knochens
    • KUMMER, B.: Grundlagen der Pauwels-Theorie der funktionellen Anpassung des Knochens. Orthopäde, 24: 387-393, 1995.
    • (1995) Orthopäde , vol.24 , pp. 387-393
    • Kummer, B.1
  • 16
    • 0030339451 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Skeletal Response to Well Fixed Femoral Components Inserted with and without Cement
    • MALONEY, W. J., SYCHTERZ, C., BRAGDON, C., McGOVERN, T., JASTY, M., ENGH, C. A., HARRIS, W. H.: The Otto Aufranc Award. Skeletal Response to Well Fixed Femoral Components Inserted with and without Cement. Clin. Orthop., 333: 15-26, 1996.
    • (1996) Clin. Orthop. , vol.333 , pp. 15-26
    • Maloney, W.J.1    Sychterz, C.2    Bragdon, C.3    Mcgovern, T.4    Jasty, M.5    Engh, C.A.6    Harris, W.H.7
  • 17
    • 0031733353 scopus 로고    scopus 로고
    • Total Hip Arthroplasty. Concerns with Extensively Porous Coated Femoral Components
    • McAULEY, J. P., CULPEPPER, W. J., ENGH, C. A.: Total Hip Arthroplasty. Concerns with Extensively Porous Coated Femoral Components. Clin. orthop., 355: 182-188, 1998.
    • (1998) Clin. Orthop. , vol.355 , pp. 182-188
    • Mcauley, J.P.1    Culpepper, W.J.2    Engh, C.A.3
  • 18
    • 0031725839 scopus 로고    scopus 로고
    • Total hip Arthroplasty with Porous-Coated Prostheses Fixed without Cement in Patients who Are Sixty-Five Years of Age or Older
    • McAULEY, J. P., MOORE, K. D., CULPEPPER, W. J. 2ND, ENGH, C. A.: Total hip Arthroplasty with Porous-Coated Prostheses Fixed without Cement in Patients who Are Sixty-Five Years of Age or Older. J. Bone Jt Surg., 80: 1648-1655, 1998.
    • (1998) J. Bone Jt. Surg. , vol.80 , pp. 1648-1655
    • Mcauley, J.P.1    Moore, K.D.2    Culpepper II, W.J.3    Engh, C.A.4
  • 19
    • 0033950612 scopus 로고    scopus 로고
    • Influence of Porous Coating Level on Proximal Femoral Remodeling. A Postmortem Analysis
    • McALEY, J. P., SYCHTERZ, C. J., ENGH, C. A. Sr.: Influence of Porous Coating Level on Proximal Femoral Remodeling. A Postmortem Analysis. Clin. Orthop., 371: 146-153, 2000.
    • (2000) Clin. Orthop. , vol.371 , pp. 146-153
    • Mcaley, J.P.1    Sychterz, C.J.2    Engh Sr., C.A.3
  • 20
    • 0030696486 scopus 로고    scopus 로고
    • Proximally Coated Ingrowth Prostheses. A Review
    • MONT, M. A., HUNGERFORD, D. S.: Proximally Coated Ingrowth Prostheses. A Review. Clin. Orthop., 344: 139-149, 1998.
    • (1998) Clin. Orthop. , vol.344 , pp. 139-149
    • Mont, M.A.1    Hungerford, D.S.2
  • 21
    • 0031790866 scopus 로고    scopus 로고
    • Cementless Femoral Design Concerns. Rationale for Extensive Porous Coating
    • NOURBASH, P. S., PAPROSKY, W. G.: Cementless Femoral Design Concerns. Rationale for Extensive Porous Coating. Clin. Orthop., 355: 189-199, 1998.
    • (1998) Clin. Orthop. , vol.355 , pp. 189-199
    • Nourbash, P.S.1    Paprosky, W.G.2
  • 22
    • 0026771982 scopus 로고
    • Failure of Cementless Fixation of the Femoral Component in Total Hip Arthroplasty
    • OTANI, T., WHITESIDE, L. A.: Failure of Cementless Fixation of the Femoral Component in Total Hip Arthroplasty. Orthop. Clin. N. Amer., 23: 335-346, 1992.
    • (1992) Orthop. Clin. N. Amer. , vol.23 , pp. 335-346
    • Otani, T.1    Whiteside, L.A.2
  • 23
    • 0026559828 scopus 로고
    • Natural Factors that Affect the Shape and Strength of the Aging Human Femur
    • POSS, R.: Natural Factors that Affect the Shape and Strength of the Aging Human Femur. Clin. Orthop., 274: 194-201, 1992.
    • (1992) Clin. Orthop. , vol.274 , pp. 194-201
    • Poss, R.1
  • 24
    • 0023778216 scopus 로고
    • Distal Cortical Hypertrophy Following Total Hip Athroplasty
    • RITTER, M. A., FECHTMANN, R. A.: Distal Cortical Hypertrophy Following Total Hip Athroplasty. J. Arthroplasty, 3: 117-121, 1988.
    • (1988) J. Arthroplasty , vol.3 , pp. 117-121
    • Ritter, M.A.1    Fechtmann, R.A.2
  • 26
    • 0028200785 scopus 로고
    • Late Mechanical Stability of the Proximal Coated AML Prosthesis
    • SUGIYAMA, H., WHITESIDE, L. A., ENGH, C. A., OTANI, T.: Late Mechanical Stability of the Proximal Coated AML Prosthesis. Orthopedics, 17: 583-588, 1994.
    • (1994) Orthopedics , vol.17 , pp. 583-588
    • Sugiyama, H.1    Whiteside, L.A.2    Engh, C.A.3    Otani, T.4
  • 27
    • 0026560894 scopus 로고
    • Determinants of Stress Shielding: Design Versus Materials Versus Interface
    • SUMNER, D. R., GALANTE, J. O.: Determinants of Stress Shielding: Design Versus Materials Versus Interface. Clin. Orthop., 274: 202-212, 1992.
    • (1992) Clin. Orthop. , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 28
    • 0036913582 scopus 로고    scopus 로고
    • What We Have Learned about Long-term Cementless Fixation from Autopsy Retrievals
    • SYCHTERZ, C. J., CLAUS, A. M., ENGH, C. A.: What We Have Learned about Long-term Cementless Fixation from Autopsy Retrievals. Clin. Orthop., 405: 79-91, 2002.
    • (2002) Clin. Orthop. , vol.405 , pp. 79-91
    • Sychterz, C.J.1    Claus, A.M.2    Engh, C.A.3
  • 29
    • 0030067508 scopus 로고    scopus 로고
    • The Influence of Clinical Factors on Periprosthetic Bone Remodeling
    • SYCHTERZ, C. J., ENGH, C. A.: The Influence of Clinical Factors on Periprosthetic Bone Remodeling. Clin. Orthop., 322: 285-292, 1996.
    • (1996) Clin. Orthop. , vol.322 , pp. 285-292
    • Sychterz, C.J.1    Engh, C.A.2
  • 30
    • 17644383923 scopus 로고    scopus 로고
    • První zkušenosti s použitím necementované endoprotézy kyčle s porézním povrchem
    • TRČ, T: První zkušenosti s použitím necementované endoprotézy kyčle s porézním povrchem. Acta Chir. orthop. Traum. čech. 64: 144-153, 1997.
    • (1997) Acta Chir. Orthop. Traum. Čech. , vol.64 , pp. 144-153
    • Trč, T.1
  • 31
    • 0028877232 scopus 로고
    • Julius Wolf und sein Gesetz der Transformation der Knochen
    • WOLF, J. H.: Julius Wolf und sein Gesetz der Transformation der Knochen. Orthopäde, 24: 378-386, 1995.
    • (1995) Orthopäde , vol.24 , pp. 378-386
    • Wolf, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.