메뉴 건너뛰기




Volumn 322, Issue , 1996, Pages 285-292

The influence of clinical factors on periprosthetic bone remodeling

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE ATROPHY; BONE MINERAL; BONE REMODELING; CLINICAL ARTICLE; DUAL ENERGY X RAY ABSORPTIOMETRY; ENDOPROSTHESIS; FEMALE; HIP PROSTHESIS; HUMAN; MALE; PRIORITY JOURNAL;

EID: 0030067508     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-199601000-00034     Document Type: Article
Times cited : (125)

References (21)
  • 1
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding: Laboratory and clinical observations of noncemented total hip arthroplasty
    • Bobyn JD, Mortimer ES, Glassman AH, et al: Producing and avoiding stress shielding: Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79-96, 1992.
    • (1992) Clin Orthop , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3
  • 5
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh CA, Bobyn JD: The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7-28, 1988.
    • (1988) Clin Orthop , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 6
    • 0023240947 scopus 로고
    • Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results
    • Engh CA, Bobyn JD, Glassman AH: Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg 69B:45-55, 1987.
    • (1987) J Bone Joint Surg , vol.69 B , pp. 45-55
    • Engh, C.A.1    Bobyn, J.D.2    Glassman, A.H.3
  • 7
    • 0029033572 scopus 로고
    • Evaluation of bone ingrowth in proximally and extensively porous-coated Anatomic Medullary Locking prostheses retrieved at autopsy
    • Engh CA, Hooten Jr JP, Zettl-Schaffer KF, et al: Evaluation of bone ingrowth in proximally and extensively porous-coated Anatomic Medullary Locking prostheses retrieved at autopsy. J Bone Joint Surg 77A:903-910, 1995.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 903-910
    • Engh, C.A.1    Hooten Jr., J.P.2    Zettl-Schaffer, K.F.3
  • 8
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 257: 107-128, 1990.
    • (1990) Clin Orthop , vol.257 , pp. 107-128
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 9
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone remodeling after cementless total hip arthroplasty
    • Engh CA, McGovern TF, Bobyn JD, Harris WH: A quantitative evaluation of periprosthetic bone remodeling after cementless total hip arthroplasty. J Bone Joint Surg 74A:1009-1020, 1992.
    • (1992) J Bone Joint Surg , vol.74 A , pp. 1009-1020
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 10
    • 0027226346 scopus 로고
    • Roentgenographic densitometry of bone adjacent to a femoral prosthesis
    • Engh CA, McGovern TF, Bobyn JD, Schmidt LM: Roentgenographic densitometry of bone adjacent to a femoral prosthesis. Clin Orthop 292:177-190, 1992.
    • (1992) Clin Orthop , vol.292 , pp. 177-190
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Schmidt, L.M.4
  • 11
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes R, Weinans H, VanRietbergen B: The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop 274:124-134, 1992.
    • (1992) Clin Orthop , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, H.2    VanRietbergen, B.3
  • 12
    • 0027409719 scopus 로고
    • Dual-energy x-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results
    • Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW: Dual-energy x-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results. J Bone Joint Surg 75A:279-287, 1993.
    • (1993) J Bone Joint Surg , vol.75 A , pp. 279-287
    • Kilgus, D.J.1    Shimaoka, E.E.2    Tipton, J.S.3    Eberle, R.W.4
  • 13
    • 85085669957 scopus 로고    scopus 로고
    • Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin Hip - An uncemented femoral stem
    • in press
    • Kiratli BJ, Checovich MM, McBeath AA, Wilson MA, Heiner JP: Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin Hip - An uncemented femoral stem. J Arthroplasty (in press).
    • J Arthroplasty
    • Kiratli, B.J.1    Checovich, M.M.2    McBeath, A.A.3    Wilson, M.A.4    Heiner, J.P.5
  • 14
    • 0026464523 scopus 로고
    • Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty
    • Kiratli BJ, Heiner JP, McBeath AA, Wilson MA: Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty. J Orthop Res 10:836, 1992.
    • (1992) J Orthop Res , vol.10 , pp. 836
    • Kiratli, B.J.1    Heiner, J.P.2    McBeath, A.A.3    Wilson, M.A.4
  • 16
    • 0026096845 scopus 로고
    • Mechanical properties of metaphyseal bone in the proximal femur
    • Lotz JC, Gerhardt TN, Hayes WL: Mechanical properties of metaphyseal bone in the proximal femur. J Biomechanics 24:317-329, 1991.
    • (1991) J Biomechanics , vol.24 , pp. 317-329
    • Lotz, J.C.1    Gerhardt, T.N.2    Hayes, W.L.3
  • 17
    • 9044229389 scopus 로고
    • Quantitation of femoral bone remodeling following cemented total hip replacement: An autopsy study
    • Maloney WJ, Bragdon C, Jasty M, et al: Quantitation of femoral bone remodeling following cemented total hip replacement: An autopsy study. Proc Orthopaedic Research Society 19:577, 1994.
    • (1994) Proc Orthopaedic Research Society , vol.19 , pp. 577
    • Maloney, W.J.1    Bragdon, C.2    Jasty, M.3
  • 18
    • 0025884653 scopus 로고
    • Quantifying bone loss from the proximal femur after total hip arthroplasty
    • McCarthy CK, Steinberg GG, Agren M, et al: Quantifying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg 736:774-778, 1991.
    • (1991) J Bone Joint Surg , vol.736 , pp. 774-778
    • McCarthy, C.K.1    Steinberg, G.G.2    Agren, M.3
  • 19
    • 0027944762 scopus 로고
    • Cortical bone density of the proximal femur following cementless total hip arthroplasty
    • McGovern TF, Engh CA, Zettl-Schaffer K, Hooten Jr JP: Cortical bone density of the proximal femur following cementless total hip arthroplasty. Clin Orthop 306:145-154, 1994.
    • (1994) Clin Orthop , vol.306 , pp. 145-154
    • McGovern, T.F.1    Engh, C.A.2    Zettl-Schaffer, K.3    Hooten Jr., J.P.4
  • 20
    • 0005336061 scopus 로고
    • The Adaptation of Bone to Mechanical Stress: Experimentation and Current Concepts
    • Cowin SC (ed). Boca Raton, CRC Press, Inc
    • Meade JB: The Adaptation of Bone to Mechanical Stress: Experimentation and Current Concepts. In Cowin SC (ed). Bone Mechanics. Boca Raton, CRC Press, Inc 211-253, 1991.
    • (1991) Bone Mechanics , pp. 211-253
    • Meade, J.B.1
  • 21
    • 0026154992 scopus 로고
    • Estimation of mechanical properties of cortical bone by computed tomography
    • Snyder SM, Schneider E: Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9:422-431, 1991.
    • (1991) J Orthop Res , vol.9 , pp. 422-431
    • Snyder, S.M.1    Schneider, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.