Volumn 64, Issue 3, 1997, Pages 144-153

Initial experience with non-cemented endoprosthesis of the hip joint with a porous surface;První zkušenosti s použitím necementované endoprotézy kyčle s porézním povrchem

Author keywords

Complications; Non cemented endoprostheses of the hip joint; Porous surface of endoprosthesis

Indexed keywords


EID: 17644383923     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (26)
  • 1
    • 0018970317 scopus 로고
    • The Optimum Pore Size for the Fixation of Porous-surfaced Metal Implants by Ingrows of Bone
    • BOBYN, J. D., PILLIAR, R. M. CAMERON, H. U.: The Optimum Pore Size for the Fixation of Porous-surfaced Metal Implants by Ingrows of Bone. Clin. Orthop., 150, 1980, 263-270.
    • (1980) Clin. Orthop. , vol.150 , pp. 263-270
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3
  • 2
    • 0021211621 scopus 로고
    • Human Histology of the Bone-porous Metal Implant Interface
    • BOBYN, J. D., ENGH, C. A.: Human Histology of the Bone-porous Metal Implant Interface. Orthopaedics, 7, 1984, 1410-1421.
    • (1984) Orthopaedics , vol.7 , pp. 1410-1421
    • Bobyn, J.D.1    Engh, C.A.2
  • 5
    • 0005211098 scopus 로고
    • Surgical Principles in Cementless Total Hip Arthroplasty
    • ENGH, CH. A., GLASSMAN, H., BOBYN, J. D.: Surgical Principles in Cementless Total Hip Arthroplasty. Techn. Orthop., 1986, 1 (3), 35-53.
    • (1986) Techn. Orthop. , vol.1 , Issue.3 , pp. 35-53
    • Engh, Ch.A.1    Glassman, H.2    Bobyn, J.D.3
  • 6
    • 0028123591 scopus 로고
    • Porous Coated Total Hip Replacement
    • ENGH, C. A., HOOTEN, J. P., et al.: Porous Coated Total Hip Replacement. Clin. orthop., 298, 1994, 89-96.
    • (1994) Clin. Orthop. , vol.298 , pp. 89-96
    • Engh, C.A.1    Hooten, J.P.2
  • 7
    • 27844544612 scopus 로고
    • Cementless Revision of Failed Total Hip Joint Arthroplasty: Preliminary Report
    • PENNING, J. B.: Cementless Revision of Failed Total Hip Joint Arthroplasty: Preliminary Report. Contemporary orthopaedics., Vol. 13, 1986.
    • (1986) Contemporary Orthopaedics , vol.13
    • Penning, J.B.1
  • 8
    • 0027768288 scopus 로고
    • Clinical Radiological and Human Histological Experience with Hydroxyapatite Coatings in Orthopaedic Surgery
    • GEESINK, R. G.: Clinical Radiological and Human Histological Experience with Hydroxyapatite Coatings in Orthopaedic Surgery. Acta orthop. belg., 59, 1993, Suppl. 1, 160-164.
    • (1993) Acta Orthop. Belg. , vol.59 , Issue.1 SUPPL. , pp. 160-164
    • Geesink, R.G.1
  • 9
    • 9444268418 scopus 로고    scopus 로고
    • Results of Porous Coated Total Hip Replacement in Patients 50 Years Age and Younger
    • Atlanta
    • GLASSMANN, A. H. ENGH, C. A., CULPEPPER, W. J.: Results of Porous Coated Total Hip Replacement in Patients 50 Years Age and Younger. 63rd Annual Meetin AAOS, Atlanta, 1996, 479.
    • (1996) 63rd Annual Meetin AAOS , pp. 479
    • Glassmann, A.H.1    Engh, C.A.2    Culpepper, W.J.3
  • 10
    • 0026594536 scopus 로고
    • The First 32 Years of Total Hip Arthroplasty. One Surgeons Perspective
    • HARRIS, W. H.: The First 32 Years of Total Hip Arthroplasty. One Surgeons Perspective. Clin. orthop., 274, 1992, 6-11.
    • (1992) Clin. Orthop. , vol.274 , pp. 6-11
    • Harris, W.H.1
  • 11
    • 0026346344 scopus 로고
    • Intraoperative Measurement of Rotational Stability of Femoral Components of Total Hip Arthroplasty
    • HARRIS, W. H., MULROY, R. D. jr. et al.: Intraoperative Measurement of Rotational Stability of Femoral Components of Total Hip Arthroplasty. Clin, orthop., 266, 1991, 119-126.
    • (1991) Clin, Orthop. , vol.266 , pp. 119-126
    • Harris, W.H.1    Mulroy Jr., R.D.2
  • 12
    • 1842266814 scopus 로고    scopus 로고
    • Fixation and Durability: A Comparison of 2011 Extensively and 654 Proximaly Porous Coated Femoral Hip Implants of One Design with 2-15 Year Follow up
    • Atlanta
    • KILGUS, D. J., CULPEPPER, W. J., PAPROSKY, W. G.: Fixation and Durability: a Comparison of 2011 Extensively and 654 Proximaly Porous Coated Femoral Hip Implants of One Design with 2-15 Year Follow up. 63rd Annual Meeting AAOS, Atlanta, 1996, 478.
    • (1996) 63rd Annual Meeting AAOS , pp. 478
    • Kilgus, D.J.1    Culpepper, W.J.2    Paprosky, W.G.3
  • 13
    • 0028187276 scopus 로고
    • Skúsenosti s implantáciou 110 totálnych endoprotéz bedrového kĺbu podla Zweymüllera
    • MAKAI, F., VOJTEK, R.: Skúsenosti s implantáciou 110 totálnych endoprotéz bedrového kĺbu podla Zweymüllera. Acta Chir. orthop. Traum. čech., 61, 1994, 1, 20-24.
    • (1994) Acta Chir. Orthop. Traum. Čech. , vol.61 , Issue.1 , pp. 20-24
    • Makai, F.1    Vojtek, R.2
  • 14
    • 27844558216 scopus 로고    scopus 로고
    • Results of Porous Coated Hip Replacement in the Elderly
    • Amsterodam
    • MOON, K., CULPEPPER, W. J. II. et al.: Results of Porous Coated Hip Replacement in the Elderly. SICOT Meeting, Amsterodam, 1996, 696.
    • (1996) SICOT Meeting , pp. 696
    • Moon, K.1    Culpepper II, W.J.2
  • 15
    • 0028841202 scopus 로고
    • Femoral Revision Hip Arthroplasty with Uncemented, Porous Coated Stem
    • MORELAND, J. R., BERNSTEIN, M. L.: Femoral Revision Hip Arthroplasty with Uncemented, Porous Coated Stem. Clin. orthop. 319, 1995, 141-150.
    • (1995) Clin. Orthop. , vol.319 , pp. 141-150
    • Moreland, J.R.1    Bernstein, M.L.2
  • 16
    • 27844561020 scopus 로고
    • Zementfreie Endoprothetik: Zukunft oder Medetrend?
    • Laffer, U., Durig, M. (Hrsg): Basler Neitr Chir. Basel, Karger
    • MORSCHER, E. W.: Zementfreie Endoprothetik: Zukunft oder Medetrend? In: Laffer, U., Durig, M. (Hrsg): Ethik, Technik und Konzepte. Basler Neitr Chir. Basel, Karger, 1989, Vol. 1, 34-48.
    • (1989) Ethik, Technik und Konzepte , vol.1 , pp. 34-48
    • Morscher, E.W.1
  • 17
    • 0023778434 scopus 로고
    • Development and Firs Experience with an Uncemented Press-fit Cup
    • MORSCHER, E., MASAR, Z.: Development and Firs Experience with an Uncemented Press-fit Cup. Clin. orthop., 323, 1988, 96-103.
    • (1988) Clin. Orthop. , vol.323 , pp. 96-103
    • Morscher, E.1    Masar, Z.2
  • 18
    • 0027744404 scopus 로고
    • Biomechanik zementfreier Endoprothetik
    • PLITZ, W.: Biomechanik zementfreier Endoprothetik. Z. Orthop., 131(6), 1993, 483-487.
    • (1993) Z. Orthop. , vol.131 , Issue.6 , pp. 483-487
    • Plitz, W.1
  • 19
    • 0026442786 scopus 로고
    • The Harris Galante Porous Coated Acetabular Component with Screw Fixation. Radiographic Analysis of Eighty Three Primary Hip Replacement at Minimum of Five Years
    • SCHALZRIED, T. P., HARRIS, W. H.: The Harris Galante Porous Coated Acetabular Component with Screw Fixation. Radiographic Analysis of Eighty Three Primary Hip Replacement at Minimum of Five Years. J. Bone Jt Surg., 74, 1992, 8, 1130-1139.
    • (1992) J. Bone Jt Surg. , vol.74 , Issue.8 , pp. 1130-1139
    • Schalzried, T.P.1    Harris, W.H.2
  • 20
    • 0023200875 scopus 로고
    • AML Bipolar Arthroplasty for Degenerative Hip Arthritis
    • SHAW, J. A., GREER III, R. B., KOLLAS, CH. D.: AML Bipolar Arthroplasty for Degenerative Hip Arthritis. Orthopaedics, Vol. 10, 1987, 1363-1374.
    • (1987) Orthopaedics , vol.10 , pp. 1363-1374
    • Shaw, J.A.1    Greer III, R.B.2    Kollas, Ch.D.3
  • 21
    • 0028926750 scopus 로고
    • Cementless Femoral Components Should Be Made from Cobalt Chrome
    • SOTERCANOS, N. G., ENGH, C. A. et al.: Cementless Femoral Components Should Be Made from Cobalt Chrome. Clin, orthop., 1995, 313, 146-153.
    • (1995) Clin, Orthop. , vol.313 , pp. 146-153
    • Sotercanos, N.G.1    Engh, C.A.2
  • 22
    • 0027770802 scopus 로고
    • Histology of Porous-coated Acetabular Components. 25 Cementless Cups Retrieved after Arthroplasty
    • SUMNER, D. R., JASTY, M. et al.: Histology of Porous-coated Acetabular Components. 25 Cementless Cups Retrieved after Arthroplasty Acta orthop. scand., 64, 1993, 6, 619-626.
    • (1993) Acta Orthop. Scand. , vol.64 , Issue.6 , pp. 619-626
    • Sumner, D.R.1    Jasty, M.2
  • 23
    • 0027757503 scopus 로고
    • Necementovaná femorální revizní protéza kyčelního kloubu při těžkých kostních defektech (předběžné sdělení)
    • ŠTĚDRÝ, V., PILNÁČEK, J.: Necementovaná femorální revizní protéza kyčelního kloubu při těžkých kostních defektech (předběžné sdělení). Acta Chir. orthop. Traum. çech. 1993, 60, 6, 340-343.
    • (1993) Acta Chir. Orthop. Traum. Çech. , vol.60 , Issue.6 , pp. 340-343
    • Štědrý, V.1    Pilnáček, J.2
  • 24
    • 27844431602 scopus 로고
    • Indikation und klinische Ergebnisse bei der Anwendung des SHEP systems
    • Prague
    • TAGER, K. H.: Indikation und klinische Ergebnisse bei der Anwendung des SHEP systems. In: Abstracts of Highlights in Bone Pathophysiology. Prague, 1993.
    • (1993) Abstracts of Highlights in Bone Pathophysiology
    • Tager, K.H.1
  • 25
    • 0027343926 scopus 로고
    • Experimentální a klinická studie izoelastické cervikokapitální endoprotézy POLDI. II. část. Klinická studie
    • TRČ., T., ČECH, O.: Experimentální a klinická studie izoelastické cervikokapitální endoprotézy POLDI. II. část. Klinická studie. Acta Chir. orthop. Traum. čech. 60, 1993, 22-34.
    • (1993) Acta Chir. Orthop. Traum. Čech. , vol.60 , pp. 22-34
    • Trč, T.1    Čech, O.2
  • 26
    • 27844484277 scopus 로고    scopus 로고
    • 10 Jahre Zweymüller Huftendoprothese. II
    • Bern, Stuttgart, Toronto, Hans Huber Verlag
    • ZWEYMÜLLER, K.: 10 Jahre Zweymüller Huftendoprothese. II. Wiener Symposium, Bern, Stuttgart, Toronto, Hans Huber Verlag.
    • Wiener Symposium
    • Zweymüller, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.