메뉴 건너뛰기




Volumn 30, Issue 5, 2004, Pages 289-296

Histologic evaluation of an immediately loaded titanium implant retrieved from a human after 6 months in function

Author keywords

Conical abutment connection; Crestal bone remodelling; Dental implants; Histology; Immediate loading; Microgap

Indexed keywords

COLORING AGENT; DIAGNOSTIC AGENT; TETRACYCLINE; TITANIUM;

EID: 16644373986     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/0695.1     Document Type: Article
Times cited : (19)

References (65)
  • 1
    • 0019663098 scopus 로고
    • A 15 year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15 year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10:387-416.
    • (1981) Int J Oral Surg. , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 2
    • 0001886487 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand Reconstr Surg. 1977;11(suppl 16):1-132.
    • (1977) Scand Reconstr Surg. , vol.11 , pp. 1-132
    • Brånemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 3
    • 0002386433 scopus 로고
    • Forces on dental implants and interfacial stress transfer
    • Laney WR, Tolman DE, eds., Chicago, Ill: Quintessence
    • Brunski JB. Forces on dental implants and interfacial stress transfer. In: Laney WR, Tolman DE, eds. Tissue Integration in Oral, Orthopaedic and Maxillofacial Reconstruction. Chicago, Ill: Quintessence; 1992:108-124.
    • (1992) Tissue Integration in Oral, Orthopaedic and Maxillofacial Reconstruction , pp. 108-124
    • Brunski, J.B.1
  • 4
    • 0000515698 scopus 로고
    • Influence of biomechanical factor at the bone-biomaterial interface
    • Davies JE, ed. Toronto, Ontario, Canada: Toronto University Press
    • Brunski JB. Influence of biomechanical factor at the bone-biomaterial interface. In: Davies JE, ed. The Bone- Biomaterial Interface. Toronto, Ontario, Canada: Toronto University Press; 1991: 391-405.
    • (1991) The Bone- Biomaterial Interface , pp. 391-405
    • Brunski, J.B.1
  • 5
    • 0002740053 scopus 로고
    • Effect of mechanical stress on tissue differentiation in the bony implant bed
    • Davies JE, ed, Toronto, Ontario, Canada: University of Toronto Press
    • Carter DR, Giori NJ. Effect of mechanical stress on tissue differentiation in the bony implant bed. In: Davies JE, ed. The Bone-Biomaterial Interface. Toronto, Ontario, Canada: University of Toronto Press; 1991:367-379.
    • (1991) The Bone-Biomaterial Interface , pp. 367-379
    • Carter, D.R.1    Giori, N.J.2
  • 6
    • 0031061750 scopus 로고    scopus 로고
    • Implantretained mandibular overdentures with immediate loading.Aretrospective multicenter study on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implantretained mandibular overdentures with immediate loading.Aretrospective multicenter study on 226 consecutive cases. Clin Oral Implant Res. 1997;8:48-57.
    • (1997) Clin Oral Implant Res. , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 7
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5- year data
    • Tarnow, DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5- year data. Int J Oral Maxillofac Implants. 1997;12:319-324.
    • (1997) Int J Oral Maxillofac Implants. , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 9
    • 0029348226 scopus 로고
    • Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics. A technique reexamined: Two case reports
    • Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics. A technique reexamined: two case reports. Int J Periodont Restor Dent. 1995;15:345-361.
    • (1995) Int J Periodont Restor Dent. , vol.15 , pp. 345-361
    • Salama, H.1    Rose, L.F.2    Salama, M.3    Betts, N.J.4
  • 10
    • 0033072986 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study after 24 months
    • Randow K, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study after 24 months. Clin Oral Implant Res. 1999;10:8-15.
    • (1999) Clin Oral Implant Res. , vol.10 , pp. 8-15
    • Randow, K.1    Ericsson, I.2    Nilner, K.3    Petersson, A.4    Glantz, P.O.5
  • 11
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res. 1998;43:192-203.
    • (1998) J Biomed Mater Res. , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4
  • 12
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implant Res. 2000;11:12-25.
    • (2000) Clin Oral Implant Res. , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 13
    • 0035290094 scopus 로고    scopus 로고
    • Immediate loading of single-tooth implants: Immediate versus non-immediate implantation. A clinical report
    • Chaushu G, Chaushu S, Tzohar A, Dayan D. Immediate loading of single-tooth implants: immediate versus non-immediate implantation. A clinical report. Int J Oral Maxillofac Implants. 2001;16:267-272.
    • (2001) Int J Oral Maxillofac Implants. , vol.16 , pp. 267-272
    • Chaushu, G.1    Chaushu, S.2    Tzohar, A.3    Dayan, D.4
  • 14
    • 0032233311 scopus 로고    scopus 로고
    • A prospective multicenter study evaluating loading of Osseotite implants two months after pacement: One-year results
    • Lazzara RJ, Porter SS, Testori T, Galante J, Zetterquist L. A prospective multicenter study evaluating loading of Osseotite implants two months after pacement: one-year results. J Esthet Dent. 1998;6:280-289.
    • (1998) J Esthet Dent. , vol.6 , pp. 280-289
    • Lazzara, R.J.1    Porter, S.S.2    Testori, T.3    Galante, J.4    Zetterquist, L.5
  • 15
    • 0012441776 scopus 로고    scopus 로고
    • Non-functional immediate teeth in partially edentulous patients: A pilot study of 10 consecutive cases using the maestro dental implant system
    • Misch CE. Non-functional immediate teeth in partially edentulous patients: a pilot study of 10 consecutive cases using the maestro dental implant system. Compendium. 1998;19:25-36.
    • (1998) Compendium. , vol.19 , pp. 25-36
    • Misch, C.E.1
  • 16
    • 0026834154 scopus 로고
    • Retrieval analyses of a blade implant after 231 months of clinical function
    • Linkow LI, Donath K, Lemons JE. Retrieval analyses of a blade implant after 231 months of clinical function. Implant Dent. 1992;1:37-43.
    • (1992) Implant Dent. , vol.1 , pp. 37-43
    • Linkow, L.I.1    Donath, K.2    Lemons, J.E.3
  • 17
    • 0027597595 scopus 로고
    • A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function
    • Trisi P, Emanuelli M, Quaranta M, Piattelli A. A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function. J Periodontol. 1993;64:374-378.
    • (1993) J Periodontol. , vol.64 , pp. 374-378
    • Trisi, P.1    Emanuelli, M.2    Quaranta, M.3    Piattelli, A.4
  • 18
    • 0027830480 scopus 로고
    • A histologic and histomorphometric study of the bone reactions to non submerged unloaded and loaded single implants in monkeys
    • Piattelli A, Ruggeri A, Trisi P, Romasco N, Franchi M. A histologic and histomorphometric study of the bone reactions to non submerged unloaded and loaded single implants in monkeys. J Oral Implantol. 1993;19:314-320.
    • (1993) J Oral Implantol. , vol.19 , pp. 314-320
    • Piattelli, A.1    Ruggeri, A.2    Trisi, P.3    Romasco, N.4    Franchi, M.5
  • 19
    • 0031107547 scopus 로고    scopus 로고
    • Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: A pilot study in monkeys
    • Piattelli A, Corigliano M, Scarano A, Quaranta M. Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: a pilot study in monkeys. Int J Periodont Restor Dent. 1997;17:163-169.
    • (1997) Int J Periodont Restor Dent. , vol.17 , pp. 163-169
    • Piattelli, A.1    Corigliano, M.2    Scarano, A.3    Quaranta, M.4
  • 21
    • 0027792232 scopus 로고
    • Histological analysis of a screw implant retrieved from man: Influence of early loading and primary stability
    • Piattelli A, Trisi P, Romasco N, Emanuelli M. Histological analysis of a screw implant retrieved from man: influence of early loading and primary stability. J Oral Implantol. 1993;19:303-306.
    • (1993) J Oral Implantol. , vol.19 , pp. 303-306
    • Piattelli, A.1    Trisi, P.2    Romasco, N.3    Emanuelli, M.4
  • 22
    • 0030981647 scopus 로고    scopus 로고
    • Immediate loading of titanium plasma-sprayed screwshaped implants in man: A clinical and histological report of two cases
    • Piattelli A, Paolantonio M, Corigliano M, Scarano A. Immediate loading of titanium plasma-sprayed screwshaped implants in man: a clinical and histological report of two cases. J Periodontol. 1997;68:591-597.
    • (1997) J Periodontol. , vol.68 , pp. 591-597
    • Piattelli, A.1    Paolantonio, M.2    Corigliano, M.3    Scarano, A.4
  • 23
    • 0032234784 scopus 로고    scopus 로고
    • Long-lasting osseointegration of immediately loaded bar-connected TPS screws after 12 years of function: A histologic case report of a 95-year-old patient
    • Ledermann PD, Schenk R, Buser D. Long-lasting osseointegration of immediately loaded bar-connected TPS screws after 12 years of function: a histologic case report of a 95-year-old patient. Int J Periodont Restor Dent. 1999;18:553-556.
    • (1999) Int J Periodont Restor Dent. , vol.18 , pp. 553-556
    • Ledermann, P.D.1    Schenk, R.2    Buser, D.3
  • 24
    • 0012405719 scopus 로고    scopus 로고
    • Immediately loaded screw implant removed for fracture after a 15-year loading period: Histological and histochemical analysis
    • Piattelli A, Scarano A, Paolantonio M. Immediately loaded screw implant removed for fracture after a 15-year loading period: histological and histochemical analysis. J Oral Implantol. 1997;23:75-79.
    • (1997) J Oral Implantol. , vol.23 , pp. 75-79
    • Piattelli, A.1    Scarano, A.2    Paolantonio, M.3
  • 25
    • 0035350613 scopus 로고    scopus 로고
    • Immediate loading of implants with fixed restorations in the completely edentulous mandible: Report of 27 patients from a private practice
    • Ganeles J, Rosenberg MM, Holt RL, Reichman LH. Immediate loading of implants with fixed restorations in the completely edentulous mandible: report of 27 patients from a private practice. Int J Oral Maxillofac Implants. 2001;16:418-426.
    • (2001) Int J Oral Maxillofac Implants. , vol.16 , pp. 418-426
    • Ganeles, J.1    Rosenberg, M.M.2    Holt, R.L.3    Reichman, L.H.4
  • 26
    • 0035319811 scopus 로고    scopus 로고
    • Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys
    • Romanos G, Toh CG, Siar CH, et al. Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys. J Periodontol. 2001; 72:506-511.
    • (2001) J Periodontol. , vol.72 , pp. 506-511
    • Romanos, G.1    Toh, C.G.2    Siar, C.H.3
  • 27
    • 0034183762 scopus 로고    scopus 로고
    • Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports
    • Jaffin RA, Kumar A, Berman CL. Immediate loading of implants in partially and fully edentulous jaws: a series of 27 case reports. J Periodontol. 2000; 71:833-838.
    • (2000) J Periodontol. , vol.71 , pp. 833-838
    • Jaffin, R.A.1    Kumar, A.2    Berman, C.L.3
  • 28
    • 0035487836 scopus 로고    scopus 로고
    • Immediate loading of Osseotite implants: A case report and histologic analysis after 4 months of occlusal loading
    • Testori T, Szmukler-Moncler S, Francetti L, et al. Immediate loading of Osseotite implants: a case report and histologic analysis after 4 months of occlusal loading. Int J Periodont Restor Dent. 2001;21:451-459.
    • (2001) Int J Periodont Restor Dent. , vol.21 , pp. 451-459
    • Testori, T.1    Szmukler-Moncler, S.2    Francetti, L.3
  • 29
    • 0034186403 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants
    • Gatti C, Hefliger W, Chiapasco M. Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants. Int J Oral Maxillofac Implants. 2000;15:383-388.
    • (2000) Int J Oral Maxillofac Implants. , vol.15 , pp. 383-388
    • Gatti, C.1    Hefliger, W.2    Chiapasco, M.3
  • 30
    • 0033302136 scopus 로고    scopus 로고
    • Branemark novum: A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study
    • Branemark PI, Engstrand P, Ohrnell LO, et al. Branemark novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. Clin Implant Dent Relat Res. 1999;1:2-16.
    • (1999) Clin Implant Dent Relat Res. , vol.1 , pp. 2-16
    • Branemark, P.I.1    Engstrand, P.2    Ohrnell, L.O.3
  • 31
    • 0034574960 scopus 로고    scopus 로고
    • Early functional loading of Branemark dental implants: 5-year clinical follow-up study
    • Ericsson I, Randow K, Nilner K, Peterson A. Early functional loading of Branemark dental implants: 5-year clinical follow-up study. Clin Implant Dent Relat Res. 2000;2:70-77.
    • (2000) Clin Implant Dent Relat Res. , vol.2 , pp. 70-77
    • Ericsson, I.1    Randow, K.2    Nilner, K.3    Peterson, A.4
  • 33
    • 0036362362 scopus 로고    scopus 로고
    • Histological and histomorphometric evaluation of peri-implant bone subjected to immediate loading: An experimental study with macaca fascicularis
    • Romanos GE, Toh CG, Siar CH, Swaminathan D, Ong AH. Histological and histomorphometric evaluation of peri-implant bone subjected to immediate loading: an experimental study with macaca fascicularis. Int J Oral Maxillofac Implants. 2002;17:44-51.
    • (2002) Int J Oral Maxillofac Implants. , vol.17 , pp. 44-51
    • Romanos, G.E.1    Toh, C.G.2    Siar, C.H.3    Swaminathan, D.4    Ong, A.H.5
  • 34
    • 0038176467 scopus 로고    scopus 로고
    • Peri-implant soft tissue integration of immediately loaded implants in the posterior macaque mandible: A histomorphometric study
    • Siar CH, Toh CG, Romanos G, et al. Peri-implant soft tissue integration of immediately loaded implants in the posterior macaque mandible: a histomorphometric study. J Periodontol. 2003;74: 571-578.
    • (2003) J Periodontol. , vol.74 , pp. 571-578
    • Siar, C.H.1    Toh, C.G.2    Romanos, G.3
  • 35
    • 0043014563 scopus 로고    scopus 로고
    • Histology of retrieved immediately and early loaded oxidized implants: Light microscopic observations after 5 to 9 months of loading in the posterior mandible
    • Rocci A, Martignoni M, Burgos PM, Gottlow J, Sennerby L. Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. Clin Implant Dent Relat Res. 2003;5(suppl):88-98.
    • (2003) Clin Implant Dent Relat Res. , vol.5 , pp. 88-98
    • Rocci, A.1    Martignoni, M.2    Burgos, P.M.3    Gottlow, J.4    Sennerby, L.5
  • 37
    • 0036632724 scopus 로고    scopus 로고
    • Immediate mandibular rehabilitation with endosseous implants: Simultaneous extraction, implant placement, and loading
    • Cooper LF, Rahman A, Moriarty J, Chaffee M, Sacco D. Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement, and loading. Int J Oral Maxillofac Implants. 2002;17:517-525.
    • (2002) Int J Oral Maxillofac Implants. , vol.17 , pp. 517-525
    • Cooper, L.F.1    Rahman, A.2    Moriarty, J.3    Chaffee, M.4    Sacco, D.5
  • 38
    • 0036985578 scopus 로고    scopus 로고
    • Early loading of machined-surface Branemark implants in completely edentulous mandibles: Healed bone versus fresh extraction sites
    • De Bruyn H, Collaert B. Early loading of machined-surface Branemark implants in completely edentulous mandibles: healed bone versus fresh extraction sites. Clin Implant Dent Relat Res. 2002;4:136-142.
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 136-142
    • De Bruyn, H.1    Collaert, B.2
  • 39
    • 0036988733 scopus 로고    scopus 로고
    • Early loading of four or five Astra Tech fixtures with a fixed cross-arch restoration in the mandible
    • Collaert B, De Bruyn H. Early loading of four or five Astra Tech fixtures with a fixed cross-arch restoration in the mandible. Clin Implant Dent Relat Res. 2002;4:133-135.
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 133-135
    • Collaert, B.1    De Bruyn, H.2
  • 40
    • 0038519775 scopus 로고    scopus 로고
    • Immediate loading of Branemark implants: A 24- month follow-up of a comparative prospective pilot study between mandibular overdentures supported by conical transmucosal and standard MKII implants
    • Gatti C, Chiapasco M. Immediate loading of Branemark implants: a 24- month follow-up of a comparative prospective pilot study between mandibular overdentures supported by conical transmucosal and standard MKII implants. Clin Implant Dent Relat Res. 2002;4:190-199.
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 190-199
    • Gatti, C.1    Chiapasco, M.2
  • 41
    • 0041380922 scopus 로고    scopus 로고
    • In patient comparison of immediately loaded and non-loaded implants within 6 months
    • Lorenzoni M, Pertl C, Zhang K, Wegscheider WA. In patient comparison of immediately loaded and non-loaded implants within 6 months. Clin Oral Implant Res. 2003;14:273-279.
    • (2003) Clin Oral Implant Res. , vol.14 , pp. 273-279
    • Lorenzoni, M.1    Pertl, C.2    Zhang, K.3    Wegscheider, W.A.4
  • 42
    • 0038411333 scopus 로고    scopus 로고
    • Immediate functional loading of Branemark system implants in edentulous mandibles: Clinical report of the results of developmental and simplified protocols
    • Wolfinger GJ, Balshi TJ, Rangert B. Immediate functional loading of Branemark system implants in edentulous mandibles: clinical report of the results of developmental and simplified protocols. Int J Oral Maxillofac Implants. 2003;18:250-257.
    • (2003) Int J Oral Maxillofac Implants. , vol.18 , pp. 250-257
    • Wolfinger, G.J.1    Balshi, T.J.2    Rangert, B.3
  • 43
    • 0043014586 scopus 로고    scopus 로고
    • Allon- four'' immediate-function concept with Branemark system implants for completely edentulous mandibles: A retrospective clinical study
    • Malò P, Rangert B, Nober M. ''Allon- four'' immediate-function concept with Branemark system implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res. 2003;5(suppl):2-9.
    • (2003) Clin Implant Dent Relat Res. , vol.5 , pp. 2-9
    • Malò, P.1    Rangert, B.2    Nober, M.3
  • 44
    • 0043014576 scopus 로고    scopus 로고
    • Early function of splinted implants in maxillas and posterior mandibles using Branemark system machined-surface implants: An 18-month prospective clinical multicenter study
    • Vanden Bogaerde L, Pedretti G, Dellacasa P, Mozzati M, Rangert B. Early function of splinted implants in maxillas and posterior mandibles using Branemark system machined-surface implants: an 18-month prospective clinical multicenter study. Clin Implant Dent Relat Res. 2003;5(suppl):21-28.
    • (2003) Clin Implant Dent Relat Res. , vol.5 , pp. 21-28
    • Vanden Bogaerde, L.1    Pedretti, G.2    Dellacasa, P.3    Mozzati, M.4    Rangert, B.5
  • 45
    • 0041511733 scopus 로고    scopus 로고
    • Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: A retrospective 3-year clinical study
    • Rocci A, Martignoni M, Gottlow J. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study. Clin Implant Dent Relat Res. 2003;5(suppl):29-36.
    • (2003) Clin Implant Dent Relat Res. , vol.5 , pp. 29-36
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 46
    • 0041511734 scopus 로고    scopus 로고
    • Immediate and early function of Branemark system implants placed in the esthetic zone: A 1-year prospective clinical multicenter study
    • Malò P, Friberg B, Polizzi G, Gualini F, Vighagen T, Rangert B. Immediate and early function of Branemark system implants placed in the esthetic zone: a 1-year prospective clinical multicenter study. Clin Implant Dent Relat Res. 2003;5(suppl):37-46.
    • (2003) Clin Implant Dent Relat Res. , vol.5 , pp. 37-46
    • Malò, P.1    Friberg, B.2    Polizzi, G.3    Gualini, F.4    Vighagen, T.5    Rangert, B.6
  • 47
    • 0036362162 scopus 로고    scopus 로고
    • Histologic evaluation of a human immediately loaded titanium implant with a porous anodized surface
    • Degidi M, Petrone G, Iezzi G, Piattelli A. Histologic evaluation of a human immediately loaded titanium implant with a porous anodized surface. Clin Implant Dent Relat Res. 2002;4:110-114.
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 110-114
    • Degidi, M.1    Petrone, G.2    Iezzi, G.3    Piattelli, A.4
  • 48
    • 0037296776 scopus 로고    scopus 로고
    • Immediate functional and non functional loading of dental implants: A 2 to 60 months followup study of 646 titanium implants
    • Degidi M, Piattelli A. Immediate functional and non functional loading of dental implants: a 2 to 60 months followup study of 646 titanium implants. J Periodontol. 2003;74:225-241.
    • (2003) J Periodontol. , vol.74 , pp. 225-241
    • Degidi, M.1    Piattelli, A.2
  • 49
    • 0036779585 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with ITI implants. A comparison of 2-year results between delayed and immediate loading
    • Romeo E, Chiapasco M, Lazza A, et al. Implant-retained mandibular overdentures with ITI implants. A comparison of 2-year results between delayed and immediate loading. Clin Oral Implant Res. 2002;13:495-501.
    • (2002) Clin Oral Implant Res. , vol.13 , pp. 495-501
    • Romeo, E.1    Chiapasco, M.2    Lazza, A.3
  • 50
    • 0036360163 scopus 로고    scopus 로고
    • Clinical and histologic findings for microimplants placed in one stage and loaded for three months: A case report
    • Becker W, Sennerby L, Becker BE, Henry P. Clinical and histologic findings for microimplants placed in one stage and loaded for three months: a case report. Clin Implant Dent Relat Res. 2002;4:47-52.
    • (2002) Clin Implant Dent Relat Res. , vol.4 , pp. 47-52
    • Becker, W.1    Sennerby, L.2    Becker, B.E.3    Henry, P.4
  • 51
    • 0036691273 scopus 로고    scopus 로고
    • Healing of Osseotite implants under submerged and immediate loading conditions in a single patient: A case report and interface analysis after 2 months
    • Testori T, Szmukler-Moncler S, Francetti L, Del Fabbro M, Trisi P, Weinstein RL. Healing of Osseotite implants under submerged and immediate loading conditions in a single patient: a case report and interface analysis after 2 months. Int J Periodont Restor Dent. 2002;22:345-353.
    • (2002) Int J Periodont Restor Dent. , vol.22 , pp. 345-353
    • Testori, T.1    Szmukler-Moncler, S.2    Francetti, L.3    Del Fabbro, M.4    Trisi, P.5    Weinstein, R.L.6
  • 52
    • 0031128359 scopus 로고    scopus 로고
    • High-precision, cost-effective system for producing thin sections of oral tissues containing dental implants
    • Piattelli A, Scarano A, Quaranta M. High-precision, cost-effective system for producing thin sections of oral tissues containing dental implants. Biomaterials. 1997;18:577-579.
    • (1997) Biomaterials. , vol.18 , pp. 577-579
    • Piattelli, A.1    Scarano, A.2    Quaranta, M.3
  • 53
    • 0036342923 scopus 로고    scopus 로고
    • A mechanoregulation model for tissue differentiation during fracture healing: Analysis of gap healing and loading
    • Lacroix D, Prendergast PJ. A mechanoregulation model for tissue differentiation during fracture healing: analysis of gap healing and loading. J Biomech. 2002;35:1163-1171.
    • (2002) J Biomech. , vol.35 , pp. 1163-1171
    • Lacroix, D.1    Prendergast, P.J.2
  • 54
    • 0031067775 scopus 로고    scopus 로고
    • Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible
    • Cochran DL, Hermann JS, Schenk RK, Higginbottom FL, Buser D. Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible. J Periodontol. 1997;68:186-198.
    • (1997) J Periodontol. , vol.68 , pp. 186-198
    • Cochran, D.L.1    Hermann, J.S.2    Schenk, R.K.3    Higginbottom, F.L.4    Buser, D.5
  • 56
    • 0031262411 scopus 로고    scopus 로고
    • Crestal bone changes around titanium implants: A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible
    • Hermann JS, Cochran DL, Nummikoski PV, Buser D. Crestal bone changes around titanium implants: a radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. J Periodontol. 1997;68:1117-1130.
    • (1997) J Periodontol. , vol.68 , pp. 1117-1130
    • Hermann, J.S.1    Cochran, D.L.2    Nummikoski, P.V.3    Buser, D.4
  • 58
    • 0028701189 scopus 로고
    • Microbial penetration along the implant components of the Branemark system. An in vitro study
    • Quirynen M, Bollen CM, Eyssen H, van Steenberghe D. Microbial penetration along the implant components of the Branemark system. An in vitro study. Clin Oral Implant Res. 1994;5:239-244.
    • (1994) Clin Oral Implant Res. , vol.5 , pp. 239-244
    • Quirynen, M.1    Bollen, C.M.2    Eyssen, H.3    Van Steenberghe, D.4
  • 60
    • 0035459995 scopus 로고    scopus 로고
    • Fluids and microbial penetration in the internal part of cement- retained versus screw-retained implant- abutment connections
    • Piattelli A, Scarano A, Paolantonio M, et al. Fluids and microbial penetration in the internal part of cement- retained versus screw-retained implant- abutment connections. J Periodontol. 2001;72:1146-1150.
    • (2001) J Periodontol. , vol.72 , pp. 1146-1150
    • Piattelli, A.1    Scarano, A.2    Paolantonio, M.3
  • 61
    • 0027654684 scopus 로고
    • Bacterial colonization of the internal part of two-stage implants. An in vivo study
    • Quirynen M, van Steenberghe D. Bacterial colonization of the internal part of two-stage implants. An in vivo study. Clin Oral Implant Res. 1993;4:158-161.
    • (1993) Clin Oral Implant Res. , vol.4 , pp. 158-161
    • Quirynen, M.1    Van Steenberghe, D.2
  • 62
    • 0034782965 scopus 로고    scopus 로고
    • Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible
    • Hermann JS, Schofield JD, Schenk RK, Buser D, Cochran DL. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. J Periodontol. 2001; 72:1372-1383.
    • (2001) J Periodontol. , vol.72 , pp. 1372-1383
    • Hermann, J.S.1    Schofield, J.D.2    Schenk, R.K.3    Buser, D.4    Cochran, D.L.5
  • 63
    • 0034277514 scopus 로고    scopus 로고
    • Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible
    • Hermann JS, Buser D, Schenk RK, Cochran DL. Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible. J Periodontol. 2000;71:1412-1424.
    • (2000) J Periodontol. , vol.71 , pp. 1412-1424
    • Hermann, J.S.1    Buser, D.2    Schenk, R.K.3    Cochran, D.L.4
  • 64
    • 0038505163 scopus 로고    scopus 로고
    • Role of the microgap between implant and abutment: A retrospective histologic evaluation in monkeys
    • Piattelli A, Vrespa G, Petrone G, Iezzi G, Annibali S, Scarano A. Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys. J Periodontol. 2003; 74:346-352.
    • (2003) J Periodontol. , vol.74 , pp. 346-352
    • Piattelli, A.1    Vrespa, G.2    Petrone, G.3    Iezzi, G.4    Annibali, S.5    Scarano, A.6
  • 65
    • 0035458527 scopus 로고    scopus 로고
    • A bioengineered implant for a predetermined bone cellular response to loading forces. A literature review and case reports
    • Misch CE, Bidez MW, Sharawy M. A bioengineered implant for a predetermined bone cellular response to loading forces. A literature review and case reports. J Periodontol. 2001;72:1276-1281.
    • (2001) J Periodontol. , vol.72 , pp. 1276-1281
    • Misch, C.E.1    Bidez, M.W.2    Sharawy, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.