-
1
-
-
0034114699
-
A nice challange for health economics
-
Hutton J, Maynard A. A nice challange for health economics. Health Economics 2000;9:89-93.
-
(2000)
Health Economics
, vol.9
, pp. 89-93
-
-
Hutton, J.1
Maynard, A.2
-
2
-
-
0035501277
-
Potential role of intensity-modulated radiotherapy in the treatment of tumors of the maxillary sinus
-
Adams EJ, Nutting CM, Convery DJ, Cosgrove VP, Henk JM, Dearnaley DP, et al. Potential role of intensity-modulated radiotherapy in the treatment of tumors of the maxillary sinus. Int J Radiat Oncol Biol Phys 2001;51:579-88.
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.51
, pp. 579-588
-
-
Adams, E.J.1
Nutting, C.M.2
Convery, D.J.3
Cosgrove, V.P.4
Henk, J.M.5
Dearnaley, D.P.6
-
3
-
-
0034213116
-
Radiotherapy of prostate cancer with or without intensity modulated beams: A planning comparison
-
De Meerleer GO, Vakaet LA, De Gersem WR, De Wagter C, De Naeyer B, De Neve W. Radiotherapy of prostate cancer with or without intensity modulated beams: A planning comparison. Int J Radiat Oncol Biol Phys 2000;47:639-48.
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.47
, pp. 639-648
-
-
De Meerleer, G.O.1
Vakaet, L.A.2
De Gersem, W.R.3
De Wagter, C.4
De Naeyer, B.5
De Neve, W.6
-
4
-
-
0037403119
-
Comparison of treatment plans using intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for paranasal sinus carcinoma
-
Huang D, Xia P, Akazawa P, Akazawa C, Quivey JM, Verhey LJ, et al. Comparison of treatment plans using intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for paranasal sinus carcinoma. Int J Radiat Oncol Biol Phys 2003;56:158-68.
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.56
, pp. 158-168
-
-
Huang, D.1
Xia, P.2
Akazawa, P.3
Akazawa, C.4
Quivey, J.M.5
Verhey, L.J.6
-
5
-
-
0037403225
-
Intensity-modulated radiotherapy in nasopharyngeal carcinoma: Dosimetric advantage over conventional plans and feasibility of dose escalation
-
Kam MK, Chau RM, Suen J, Choi PH, Teo PM. Intensity-modulated radiotherapy in nasopharyngeal carcinoma: Dosimetric advantage over conventional plans and feasibility of dose escalation. Int J Radiat Oncol Biol Phys 2003;56:145-57.
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.56
, pp. 145-157
-
-
Kam, M.K.1
Chau, R.M.2
Suen, J.3
Choi, P.H.4
Teo, P.M.5
-
6
-
-
0034306879
-
Reduction of small and large bowel irradiation using an optimized intensity-modulated pelvic radiotherapy technique in patients with prostate cancer
-
Nutting CM, Convery DJ, Cosgrove VP, Rowbottom C, Padhani AR, Webb S, et al. Reduction of small and large bowel irradiation using an optimized intensity-modulated pelvic radiotherapy technique in patients with prostate cancer. Int J Radiat Oncol Biol Phys 2000;48:649-56.
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, pp. 649-656
-
-
Nutting, C.M.1
Convery, D.J.2
Cosgrove, V.P.3
Rowbottom, C.4
Padhani, A.R.5
Webb, S.6
-
7
-
-
0034748989
-
A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy
-
Nutting CM, Bedford JL, Cosgrove VP, Tait DM, Dearnaley DP, Webb S. A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy. Radiother Oncol 2001;61:157-63.
-
(2001)
Radiother Oncol
, vol.61
, pp. 157-163
-
-
Nutting, C.M.1
Bedford, J.L.2
Cosgrove, V.P.3
Tait, D.M.4
Dearnaley, D.P.5
Webb, S.6
-
10
-
-
0035987814
-
Clinical implementation of intensity-modulated radiation therapy
-
Saw CB, Ayyangar KM, Zhen W, Yoe-Sein M, Pillai S, Enke CA. Clinical implementation of intensity-modulated radiation therapy. Med Dosim 2002;27:161-9.
-
(2002)
Med Dosim
, vol.27
, pp. 161-169
-
-
Saw, C.B.1
Ayyangar, K.M.2
Zhen, W.3
Yoe-Sein, M.4
Pillai, S.5
Enke, C.A.6
-
11
-
-
0036804332
-
Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments
-
Van Esch A, Bohsung J, Sorvari P, Tenhunen M, Paiusco M, Iori M, et al. Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments. Radiother Oncol 2002;65:53-70.
-
(2002)
Radiother Oncol
, vol.65
, pp. 53-70
-
-
Van Esch, A.1
Bohsung, J.2
Sorvari, P.3
Tenhunen, M.4
Paiusco, M.5
Iori, M.6
-
12
-
-
0032790945
-
Smart (simultaneous modulated accelerated radiation therapy) boost: A new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy
-
Butler EB, Teh BS, Grant WH III, Uhl BM, Kuppersmith RB, Chiu JK, et al. Smart (simultaneous modulated accelerated radiation therapy) boost: A new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys 1999;45:21-32.
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.45
, pp. 21-32
-
-
Butler, E.B.1
Teh, B.S.2
Grant III, W.H.3
Uhl, B.M.4
Kuppersmith, R.B.5
Chiu, J.K.6
-
13
-
-
0033955922
-
Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers
-
Mohan R, Wu Q, Manning M, Schmidt-Ullrich R. Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers. Int J Radiat Oncol Biol Phys 2000;46:619-30.
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.46
, pp. 619-630
-
-
Mohan, R.1
Wu, Q.2
Manning, M.3
Schmidt-Ullrich, R.4
-
14
-
-
0034962347
-
Improvements in target coverage and reduced spinal cord irradiation using intensity-modulated radiotherapy (IMRT) in patients with carcinoma of the thyroid gland
-
Nutting CM, Convery DJ, Cosgrove VP, Rowbottom C, Vini L, Harmer C, et al. Improvements in target coverage and reduced spinal cord irradiation using intensity-modulated radiotherapy (IMRT) in patients with carcinoma of the thyroid gland. Radiother Oncol 2001;60:173-80.
-
(2001)
Radiother Oncol
, vol.60
, pp. 173-180
-
-
Nutting, C.M.1
Convery, D.J.2
Cosgrove, V.P.3
Rowbottom, C.4
Vini, L.5
Harmer, C.6
-
15
-
-
10744221799
-
Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement
-
(In press)
-
Adams EJ, Convery DJ, Cosgrove VP, McNair HA, Staffurth J, Vaarkamp J, et al. Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. Radiother Oncol (In press).
-
Radiother Oncol
-
-
Adams, E.J.1
Convery, D.J.2
Cosgrove, V.P.3
McNair, H.A.4
Staffurth, J.5
Vaarkamp, J.6
-
16
-
-
85024940413
-
IMRT clinical implementation: Prostate and pelvic node irradiation using Helios and a 120-leaf multileaf collimator
-
Clark CH, Mubata CD, Meehan CA, Bidmead AM, Staffurth J, Humphreys ME, et al. IMRT clinical implementation: Prostate and pelvic node irradiation using Helios and a 120-leaf multileaf collimator. J Appl Clin Med Phys 2002;3:273-84.
-
(2002)
J Appl Clin Med Phys
, vol.3
, pp. 273-284
-
-
Clark, C.H.1
Mubata, C.D.2
Meehan, C.A.3
Bidmead, A.M.4
Staffurth, J.5
Humphreys, M.E.6
-
17
-
-
0028803534
-
Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
-
Van Herk M, Bruce A, Kroes AP, Shouman T, Touw A, Lebesque JV. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. Int J Radiat Oncol Biol Phys 1995;33:1311-20.
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.33
, pp. 1311-1320
-
-
Van Herk, M.1
Bruce, A.2
Kroes, A.P.3
Shouman, T.4
Touw, A.5
Lebesque, J.V.6
-
18
-
-
0036463773
-
Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet
-
Burton KE, Thomas SJ, Whitney D, Routsis DS, Benson RJ, Burnet NG. Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet. Clin Oncol (R Coll Radiol) 2002;14:31-9.
-
(2002)
Clin Oncol (R Coll Radiol)
, vol.14
, pp. 31-39
-
-
Burton, K.E.1
Thomas, S.J.2
Whitney, D.3
Routsis, D.S.4
Benson, R.J.5
Burnet, N.G.6
-
19
-
-
0025907619
-
A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging
-
Graham JD, Warrington AP, Gill SS, Brada M. A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. Radiother Oncol 1991;21:60-2.
-
(1991)
Radiother Oncol
, vol.21
, pp. 60-62
-
-
Graham, J.D.1
Warrington, A.P.2
Gill, S.S.3
Brada, M.4
-
20
-
-
0032891555
-
Patient position reproducibility in fractionated stereotactic radiotherapy: An update after changing dental impression material
-
Rosenberg I, Alheit H, Beardmore C, Lee KS, Warrington AP, Brada M. Patient position reproducibility in fractionated stereotactic radiotherapy: An update after changing dental impression material. Radiother Oncol 1999;50:239-40.
-
(1999)
Radiother Oncol
, vol.50
, pp. 239-240
-
-
Rosenberg, I.1
Alheit, H.2
Beardmore, C.3
Lee, K.S.4
Warrington, A.P.5
Brada, M.6
-
21
-
-
0031892627
-
The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation
-
Yu CX, Jaffray DA, Wong JW. The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. Phys Med Biol 1998;43:91-104.
-
(1998)
Phys Med Biol
, vol.43
, pp. 91-104
-
-
Yu, C.X.1
Jaffray, D.A.2
Wong, J.W.3
-
22
-
-
0037036516
-
Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
-
Bortfeld T, Jokivarsi T, Goitein M, Kung J, Jiang SB. Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation. Phys Med Biol 2002;47:2203-20.
-
(2002)
Phys Med Biol
, vol.47
, pp. 2203-2220
-
-
Bortfeld, T.1
Jokivarsi, T.2
Goitein, M.3
Kung, J.4
Jiang, S.B.5
-
23
-
-
0038497901
-
An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments
-
Jiang SB, Pope C, Al Jarrah KM, Kung JH, Bortfield T, Chen GTY. An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. Phys Med Biol 2003;48:1773-84.
-
(2003)
Phys Med Biol
, vol.48
, pp. 1773-1784
-
-
Jiang, S.B.1
Pope, C.2
Al Jarrah, K.M.3
Kung, J.H.4
Bortfield, T.5
Chen, G.T.Y.6
-
24
-
-
0031128389
-
Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning
-
Melian E, Mageras GS, Fuks Z, Leibel SA, Niehaus A, Lorant H, et al. Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning. Int J Radiat Oncol Biol Phys 1997;38:73-81.
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.38
, pp. 73-81
-
-
Melian, E.1
Mageras, G.S.2
Fuks, Z.3
Leibel, S.A.4
Niehaus, A.5
Lorant, H.6
-
25
-
-
0033037392
-
Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI
-
Padhani AR, Khoo VS, Suckling J, Husband JE, Leach MO, Dearnaley DP. Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. Int J Radiat Oncol Biol Phys 1999;44:525-33.
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.44
, pp. 525-533
-
-
Padhani, A.R.1
Khoo, V.S.2
Suckling, J.3
Husband, J.E.4
Leach, M.O.5
Dearnaley, D.P.6
-
26
-
-
0028784185
-
Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy
-
Roeske JC, Forman JD, Mesina CF, He T, Pelizzari CA, Fontenla E, et al. Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. Int J Radiat Oncol Biol Phys 1995;33:1321-9.
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.33
, pp. 1321-1329
-
-
Roeske, J.C.1
Forman, J.D.2
Mesina, C.F.3
He, T.4
Pelizzari, C.A.5
Fontenla, E.6
-
27
-
-
0036137840
-
The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer
-
Wachter S, Gerstner N, Dorner D, Goldner G, Colotto A, Wambersie A, et al. The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2002;52:91-100.
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.52
, pp. 91-100
-
-
Wachter, S.1
Gerstner, N.2
Dorner, D.3
Goldner, G.4
Colotto, A.5
Wambersie, A.6
-
28
-
-
0034748364
-
Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers
-
Wu J, Haycocks T, Alasti H, Ottewell G, Middlemiss N, Abdolell M, et al. Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers. Radiother Oncol 2001;61:127-33.
-
(2001)
Radiother Oncol
, vol.61
, pp. 127-133
-
-
Wu, J.1
Haycocks, T.2
Alasti, H.3
Ottewell, G.4
Middlemiss, N.5
Abdolell, M.6
-
29
-
-
0037100122
-
Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
-
Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, Van Herk M, Lebesque JV, et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 2002;53:822-34.
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, pp. 822-834
-
-
Seppenwoolde, Y.1
Shirato, H.2
Kitamura, K.3
Shimizu, S.4
Van Herk, M.5
Lebesque, J.V.6
-
30
-
-
0035168732
-
Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: A feasibility study
-
Kim DJ, Murray BR, Halperin R, Roa WH. Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: A feasibility study. Int J Radiat Oncol Biol Phys 2001;49:43-9.
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.49
, pp. 43-49
-
-
Kim, D.J.1
Murray, B.R.2
Halperin, R.3
Roa, W.H.4
-
31
-
-
0032844267
-
Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
-
Hanley J, Debois MM, Mah D, Mageras GS, Raben A, Rosenzweig K, et al. Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation. Int J Radiat Oncol Biol Phys 1999;45:603-11.
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.45
, pp. 603-611
-
-
Hanley, J.1
Debois, M.M.2
Mah, D.3
Mageras, G.S.4
Raben, A.5
Rosenzweig, K.6
-
32
-
-
0033013520
-
The use of active breathing control (ABC) to reduce margin for breathing motion
-
Wong JW, Sharpe MB, Jaffray DA, Kini VR, Robertson JM, Stromberg JS, et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 1999;44:911-9.
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.44
, pp. 911-919
-
-
Wong, J.W.1
Sharpe, M.B.2
Jaffray, D.A.3
Kini, V.R.4
Robertson, J.M.5
Stromberg, J.S.6
-
33
-
-
0028797095
-
Measurement of prostate movement over the course of routine radiotherapy using implanted markers
-
Balter J, Sandler H, Lam K, Bree R, Lichter A, Ten Haken R. Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Int J Radiat Oncol Phys 1995;31:113-8.
-
(1995)
Int J Radiat Oncol Phys
, vol.31
, pp. 113-118
-
-
Balter, J.1
Sandler, H.2
Lam, K.3
Bree, R.4
Lichter, A.5
Ten Haken, R.6
-
34
-
-
0028811317
-
Prostate motion during standard radiotherapy as assessed by fiducial markers
-
Crook JM, Raymond Y, Salhani D, Yang H, Esche B. Prostate motion during standard radiotherapy as assessed by fiducial markers. Radiother Oncol 1995;37:35-42.
-
(1995)
Radiother Oncol
, vol.37
, pp. 35-42
-
-
Crook, J.M.1
Raymond, Y.2
Salhani, D.3
Yang, H.4
Esche, B.5
-
35
-
-
0036223115
-
Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
-
Kitamura K, Shirato H, Shimizu S, Shinohara N, Harabayashi T, Shimizu T, et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol 2002;62:275-81.
-
(2002)
Radiother Oncol
, vol.62
, pp. 275-281
-
-
Kitamura, K.1
Shirato, H.2
Shimizu, S.3
Shinohara, N.4
Harabayashi, T.5
Shimizu, T.6
-
36
-
-
0036471251
-
Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: An improved online imaging system
-
Pang G, Beachey DJ, O'Brien PF, Rowlands JA. Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: An improved online imaging system. Int J Radiat Oncol Biol Phys 2002;52:532-7.
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.52
, pp. 532-537
-
-
Pang, G.1
Beachey, D.J.2
O'Brien, P.F.3
Rowlands, J.A.4
-
37
-
-
0034566036
-
Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers
-
Shimizu S, Shirato H, Kitamura K, Shinohara N, Harabayashi T, Tsukamoto T, et al. Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. Int J Radiat Oncol Biol Phys 2000;48:1591-7.
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, pp. 1591-1597
-
-
Shimizu, S.1
Shirato, H.2
Kitamura, K.3
Shinohara, N.4
Harabayashi, T.5
Tsukamoto, T.6
-
38
-
-
0034333029
-
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
-
Shirato H, Shimizu S, Kunieda T, Kitamura K, Van Herk M, Kagei K, et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys 2000;48:1187-95.
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, pp. 1187-1195
-
-
Shirato, H.1
Shimizu, S.2
Kunieda, T.3
Kitamura, K.4
Van Herk, M.5
Kagei, K.6
-
39
-
-
0036852607
-
An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT
-
Hugo GD, Agazaryan N, Solberg TD. An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT. Med Phys 2002;29:2517-25.
-
(2002)
Med Phys
, vol.29
, pp. 2517-2525
-
-
Hugo, G.D.1
Agazaryan, N.2
Solberg, T.D.3
-
40
-
-
0036127077
-
Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy
-
Kubo HD, Wang L. Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy. Med Phys 2002;29:345-50.
-
(2002)
Med Phys
, vol.29
, pp. 345-350
-
-
Kubo, H.D.1
Wang, L.2
-
41
-
-
0034762764
-
Determining parameters for respiration-gated radiotherapy
-
Vedam SS, Keall PJ, Kini VR, Mohan R. Determining parameters for respiration-gated radiotherapy. Med Phys 2001;28:2139-46.
-
(2001)
Med Phys
, vol.28
, pp. 2139-2146
-
-
Vedam, S.S.1
Keall, P.J.2
Kini, V.R.3
Mohan, R.4
-
42
-
-
0037361653
-
Patient training in respiratory-gated radiotherapy
-
Kini VR, Vedam SS, Keall PJ, Patil S, Chen C, Mohan R. Patient training in respiratory-gated radiotherapy. Med Dosim 2003;28:7-11.
-
(2003)
Med Dosim
, vol.28
, pp. 7-11
-
-
Kini, V.R.1
Vedam, S.S.2
Keall, P.J.3
Patil, S.4
Chen, C.5
Mohan, R.6
-
43
-
-
0033007343
-
Clinical efficacy of respiratory gated conformal radiation therapy
-
Ramsey CR, Scaperoth D, Arwood D, Oliver AL. Clinical efficacy of respiratory gated conformal radiation therapy. Med Dosim 1999;24:115-9.
-
(1999)
Med Dosim
, vol.24
, pp. 115-119
-
-
Ramsey, C.R.1
Scaperoth, D.2
Arwood, D.3
Oliver, A.L.4
-
45
-
-
0036680186
-
Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer
-
Morr J, DiPetrillo T, Tsai JS, Engler M, Wazer DE. Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2002;53:1124-9.
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, pp. 1124-1129
-
-
Morr, J.1
DiPetrillo, T.2
Tsai, J.S.3
Engler, M.4
Wazer, D.E.5
-
46
-
-
0033753216
-
Ultrasound-based stereotactic guidance in prostate cancer-quantification of organ motion and set-up errors in external beam radiation therapy
-
Lattanzi J, McNeeley S, Donnelly S, Palacio E, Hanlon A, Schultheiss TE, et al. Ultrasound-based stereotactic guidance in prostate cancer-quantification of organ motion and set-up errors in external beam radiation therapy. Comput Aided Surg 2000;5:289-95.
-
(2000)
Comput Aided Surg
, vol.5
, pp. 289-295
-
-
Lattanzi, J.1
McNeeley, S.2
Donnelly, S.3
Palacio, E.4
Hanlon, A.5
Schultheiss, T.E.6
-
47
-
-
0031831777
-
Clinical variability of target volume description in conformal radiotherapy planning
-
Logue JP, Sharrock CL, Cowan RA, Read G, Marrs J, Mott D. Clinical variability of target volume description in conformal radiotherapy planning. Int J Radiat Oncol Biol Phys 1998;41:929-31.
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.41
, pp. 929-931
-
-
Logue, J.P.1
Sharrock, C.L.2
Cowan, R.A.3
Read, G.4
Marrs, J.5
Mott, D.6
-
48
-
-
0034237259
-
Target volume definition in conformal radiotherapy for prostate cancer: Quality assurance in the MRC RT-01 trial
-
Seddon B, Bidmead M, Wilson J, Khoo V, Dearnaley D. Target volume definition in conformal radiotherapy for prostate cancer: Quality assurance in the MRC RT-01 trial. Radiother Oncol 2000;56:73-83.
-
(2000)
Radiother Oncol
, vol.56
, pp. 73-83
-
-
Seddon, B.1
Bidmead, M.2
Wilson, J.3
Khoo, V.4
Dearnaley, D.5
-
49
-
-
0037240202
-
The impact of gross tumor volume (GTV) and clinical target volume (CTV) definition on the total accuracy in radiotherapy theoretical aspects and practical experiences
-
Weiss E, Hess CF. The impact of gross tumor volume (GTV) and clinical target volume (CTV) definition on the total accuracy in radiotherapy theoretical aspects and practical experiences. Strahlenther Onkol 2003;179:21-30.
-
(2003)
Strahlenther Onkol
, vol.179
, pp. 21-30
-
-
Weiss, E.1
Hess, C.F.2
-
50
-
-
0344530449
-
IMRT: Delivery techniques and quality assurance
-
Williams PC. IMRT: Delivery techniques and quality assurance. Br J Radiol 2003;76:766-76.
-
(2003)
Br J Radiol
, vol.76
, pp. 766-776
-
-
Williams, P.C.1
-
51
-
-
0029931223
-
Testing of dynamic multileaf collimation
-
Chui CS, Spirou S, LoSasso T. Testing of dynamic multileaf collimation. Med Phys 1996;23:635-41.
-
(1996)
Med Phys
, vol.23
, pp. 635-641
-
-
Chui, C.S.1
Spirou, S.2
LoSasso, T.3
-
52
-
-
0031861573
-
A technique for the quantitative evaluation of dose distributions
-
Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys 1998;25:656-61.
-
(1998)
Med Phys
, vol.25
, pp. 656-661
-
-
Low, D.A.1
Harms, W.B.2
Mutic, S.3
Purdy, J.A.4
-
53
-
-
0345701465
-
Routine IMRT verification by means of an automated Monte Carlo simulation system
-
Leal A, Sanchez-Doblado F, Arrans R, Rosello J, Pavon EC, Lagares JI. Routine IMRT verification by means of an automated Monte Carlo simulation system. Int J Radiat Oncol Biol Phys 2003;56:58-68.
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.56
, pp. 58-68
-
-
Leal, A.1
Sanchez-Doblado, F.2
Arrans, R.3
Rosello, J.4
Pavon, E.C.5
Lagares, J.I.6
-
54
-
-
0037111196
-
The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique
-
Fielding AL, Evans PM, Clark CH. The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique. Int J Radiat Oncol Biol Phys 2002;54:1225-34.
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.54
, pp. 1225-1234
-
-
Fielding, A.L.1
Evans, P.M.2
Clark, C.H.3
-
55
-
-
1542548636
-
How routine can IMRT become in daily clinical practice?
-
Miles EA, Clark CH, Guerro Urbano MT, Dearnaley DP, Nutting CM. How routine can IMRT become in daily clinical practice? Clin Oncol 2003;15,S30:40.
-
(2003)
Clin Oncol
, vol.15
, Issue.S30
, pp. 40
-
-
Miles, E.A.1
Clark, C.H.2
Guerro Urbano, M.T.3
Dearnaley, D.P.4
Nutting, C.M.5
|