-
1
-
-
0034255213
-
Evaluation of silica resins for direct and efficient extraction of DNA from complex biological matrices in a miniaturized format
-
Tian H, Huhmer AF, Landers JP. Evaluation of silica resins for direct and efficient extraction of DNA from complex biological matrices in a miniaturized format. Anal. Biochem. 283(2), 175-191 (2000).
-
(2000)
Anal. Biochem.
, vol.283
, Issue.2
, pp. 175-191
-
-
Tian, H.1
Huhmer, A.F.2
Landers, J.P.3
-
2
-
-
0033574773
-
PCR detection of bacteria in seven minutes
-
Belgrader P, Benett W, Hadley D et al. PCR detection of bacteria in seven minutes. Science 284(5413), 449-450 (1999).
-
(1999)
Science
, vol.284
, Issue.5413
, pp. 449-450
-
-
Belgrader, P.1
Benett, W.2
Hadley, D.3
-
3
-
-
0033972757
-
A microfluidic cartridge to prepare spores for PCR analysis
-
Belgrader P, Okuzumi M, Pourahmadi F, Borkholder DA, Northrup MA. A microfluidic cartridge to prepare spores for PCR analysis. Biosens. Bioelectron. 14(10-11), 849-852 (2000).
-
(2000)
Biosens. Bioelectron.
, vol.14
, Issue.10-11
, pp. 849-852
-
-
Belgrader, P.1
Okuzumi, M.2
Pourahmadi, F.3
Borkholder, D.A.4
Northrup, M.A.5
-
4
-
-
0036200750
-
MEMS-based sample preparation for molecular diagnostics
-
Huang Y, Mather EL, Bell JL, Madou M. MEMS-based sample preparation for molecular diagnostics. Anal. Bioanal. Chem. 372(1), 49-65 (2002). • Detailed description of microelectromechanical systems applied to the different stages of sample preparation processes.
-
(2002)
Anal. Bioanal. Chem.
, vol.372
, Issue.1
, pp. 49-65
-
-
Huang, Y.1
Mather, E.L.2
Bell, J.L.3
Madou, M.4
-
5
-
-
0035298631
-
Electric manipulation of bioparticles and macromolecules on microfabricated electrodes
-
Huang Y, Ewalt KL, Tirado M et al. Electric manipulation of bioparticles and macromolecules on microfabricated electrodes. Anal. Chem. 73(7), 1549-1559 (2001).
-
(2001)
Anal. Chem.
, vol.73
, Issue.7
, pp. 1549-1559
-
-
Huang, Y.1
Ewalt, K.L.2
Tirado, M.3
-
6
-
-
0033106015
-
Cell separation on microfabricated electrodes using dielectrophoretic/ gravitational field-flow fractionation
-
Yang J, Huang Y, Wang XB, Becker FF, Gascoyne PR. Cell separation on microfabricated electrodes using dielectrophoretic/gravitational field-flow fractionation. Anal. Chem. 71(5), 911-918 (1999).
-
(1999)
Anal. Chem.
, vol.71
, Issue.5
, pp. 911-918
-
-
Yang, J.1
Huang, Y.2
Wang, X.B.3
Becker, F.F.4
Gascoyne, P.R.5
-
7
-
-
0032719910
-
The removal of human breast cancer cells from hematopoietic CD34+ stem cells by dielectrophoretic field-flow-fractionation
-
Huang Y, Yang J, Wang XB, Becker FF, Gascoyne PR. The removal of human breast cancer cells from hematopoietic CD34+ stem cells by dielectrophoretic field-flow-fractionation. J. Hematother. Stem Cell Res. 8(5), 481-490 (1999).
-
(1999)
J. Hematother. Stem Cell Res.
, vol.8
, Issue.5
, pp. 481-490
-
-
Huang, Y.1
Yang, J.2
Wang, X.B.3
Becker, F.F.4
Gascoyne, P.R.5
-
8
-
-
0034071382
-
Differential analysis of human leukocytes by dielectrophoretic field-flow-fractionation
-
Yang J, Huang Y, Wang XB, Becker FF, Gascoyne PR. Differential analysis of human leukocytes by dielectrophoretic field-flow-fractionation. Biophys. J. 78(5), 2680-2689 (2000).
-
(2000)
Biophys. J.
, vol.78
, Issue.5
, pp. 2680-2689
-
-
Yang, J.1
Huang, Y.2
Wang, X.B.3
Becker, F.F.4
Gascoyne, P.R.5
-
9
-
-
10744226796
-
The potential of dielectrophoresis for single-cell experiments
-
Muller T, Pfennig A, Klein P, Gradl G, Jager M, Schnelle T. The potential of dielectrophoresis for single-cell experiments. IEEE Eng. Med. Biol. Mag. 22(6), 51-61 (2003).
-
(2003)
IEEE Eng. Med. Biol. Mag.
, vol.22
, Issue.6
, pp. 51-61
-
-
Muller, T.1
Pfennig, A.2
Klein, P.3
Gradl, G.4
Jager, M.5
Schnelle, T.6
-
10
-
-
0032091043
-
Isolation of cultured cervical carcinoma cells mixed with peripheral blood cells on a bioelectronic chip
-
Cheng J, Sheldon EL, Wu L, Heller MJ, O'Connell JP. Isolation of cultured cervical carcinoma cells mixed with peripheral blood cells on a bioelectronic chip. Anal. Chem. 70(11), 2321-2326 (1998).
-
(1998)
Anal. Chem.
, vol.70
, Issue.11
, pp. 2321-2326
-
-
Cheng, J.1
Sheldon, E.L.2
Wu, L.3
Heller, M.J.4
O'Connell, J.P.5
-
11
-
-
12844260686
-
Micro-and nanofluidics for DNA analysis
-
Tegenfeldt JO, Prinz C, Cao H et al. Micro-and nanofluidics for DNA analysis. Anal. Bioanal. Chem. 378(7), 1678-1692 (2004).
-
(2004)
Anal. Bioanal. Chem.
, vol.378
, Issue.7
, pp. 1678-1692
-
-
Tegenfeldt, J.O.1
Prinz, C.2
Cao, H.3
-
12
-
-
0035986206
-
A nanobiotechnology roadmap for high-throughput single nucleotide polymorphism analysis
-
Galvin P. A nanobiotechnology roadmap for high-throughput single nucleotide polymorphism analysis. Psychiatr. Genet. 12(2), 75-82 (2002). •• Interesting description of new single nucleotide polymorphism screening methods, from high-throughput platforms to the single-use applications, including their potential in molecular diagnostics.
-
(2002)
Psychiatr. Genet.
, vol.12
, Issue.2
, pp. 75-82
-
-
Galvin, P.1
-
14
-
-
0035082853
-
Microchip module for blood sample preparation and nucleic acid amplification reactions
-
Yuen PK, Kricka LJ, Fortina P, Panaro NJ, Sakazume T, Wilding P. Microchip module for blood sample preparation and nucleic acid amplification reactions. Genome Res. 11(3), 405-412 (2001).
-
(2001)
Genome Res.
, vol.11
, Issue.3
, pp. 405-412
-
-
Yuen, P.K.1
Kricka, L.J.2
Fortina, P.3
Panaro, N.J.4
Sakazume, T.5
Wilding, P.6
-
15
-
-
0032521325
-
Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers
-
Wilding P, Kricka LJ, Cheng J, Hvichia G, Shoffner MA, Fortina P. Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers. Anal. Biochem. 257(2) 95-100 (1998).
-
(1998)
Anal. Biochem.
, vol.257
, Issue.2
, pp. 95-100
-
-
Wilding, P.1
Kricka, L.J.2
Cheng, J.3
Hvichia, G.4
Shoffner, M.A.5
Fortina, P.6
-
16
-
-
0033621575
-
Active microeletronic chip devices which utilize controlled electrophoretic fields for multiplex DNA hybridization and other genomic applications
-
Heller MJ, Forster AH, Tu E. Active microeletronic chip devices which utilize controlled electrophoretic fields for multiplex DNA hybridization and other genomic applications. Electrophoresis 21(1), 157-164 (2000).
-
(2000)
Electrophoresis
, vol.21
, Issue.1
, pp. 157-164
-
-
Heller, M.J.1
Forster, A.H.2
Tu, E.3
-
17
-
-
0031810035
-
Preparation and hybridization analysis of DNA/RNA from E. coli on microfabricated bioelectronic chips
-
Cheng J, Sheldon EL, Wu L et al. Preparation and hybridization analysis of DNA/RNA from E. coli on microfabricated bioelectronic chips. Nature Biotechnol. 16(6), 541-546 (1998).
-
(1998)
Nature Biotechnol.
, vol.16
, Issue.6
, pp. 541-546
-
-
Cheng, J.1
Sheldon, E.L.2
Wu, L.3
-
18
-
-
0037422122
-
Microfluidics: DNA amplification moves on
-
deMello AJ. Microfluidics: DNA amplification moves on. Nature 422(6927), 28-29 (2003).
-
(2003)
Nature
, vol.422
, Issue.6927
, pp. 28-29
-
-
DeMello, A.J.1
-
20
-
-
0033804353
-
Automation for genomics, part two: Sequencers, microarrays, and future trends
-
Meldrum D. Automation for genomics, part two: sequencers, microarrays, and future trends. Genome Res. 10(9), 1288-1303 (2000).
-
(2000)
Genome Res.
, vol.10
, Issue.9
, pp. 1288-1303
-
-
Meldrum, D.1
-
21
-
-
0029939192
-
Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chips
-
Cheng J, Shoffner MA, Hvichia GE, Kricka LJ, Wilding P. Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chips. Nucleic Acids Res. 24(2), 380-385 (1996).
-
(1996)
Nucleic Acids Res.
, vol.24
, Issue.2
, pp. 380-385
-
-
Cheng, J.1
Shoffner, M.A.2
Hvichia, G.E.3
Kricka, L.J.4
Wilding, P.5
-
22
-
-
0032524099
-
Chemical amplification: Continuous-flow PCR on a chip
-
Kopp MU, Mello AJ, Manz A. Chemical amplification: continuous-flow PCR on a chip. Science 280(5366), 1046-1048 (1998).
-
(1998)
Science
, vol.280
, Issue.5366
, pp. 1046-1048
-
-
Kopp, M.U.1
Mello, A.J.2
Manz, A.3
-
23
-
-
0035311755
-
Polymerase chain reaction in polymeric microchips: DNA amplification in less than 240 seconds
-
Giordano BC, Ferrance J, Swedberg S, Huhmer AF, Landers JP. Polymerase chain reaction in polymeric microchips: DNA amplification in less than 240 seconds. Anal. Biochem. 291(1), 124-132 (2001).
-
(2001)
Anal. Biochem.
, vol.291
, Issue.1
, pp. 124-132
-
-
Giordano, B.C.1
Ferrance, J.2
Swedberg, S.3
Huhmer, A.F.4
Landers, J.P.5
-
24
-
-
0036952771
-
Application of a microchamber array for DNA amplification using a novel dispensing method
-
Matsubara Y, Kobayashi M, Morita Y, Tamiiya E. Application of a microchamber array for DNA amplification using a novel dispensing method. Arch. Histol. Cytol. 65(5) 481-488 (2002).
-
(2002)
Arch. Histol. Cytol.
, vol.65
, Issue.5
, pp. 481-488
-
-
Matsubara, Y.1
Kobayashi, M.2
Morita, Y.3
Tamiiya, E.4
-
25
-
-
0031607381
-
Microchip device for cell lysis, multiplex PCR amplification, and electrophoretic sizing
-
Waters LC, Jacobson SC, Kroutchinina N, Khandurina J, Foote RS, Ramsey JM. Microchip device for cell lysis, multiplex PCR amplification, and electrophoretic sizing. Anal. Chem. 70(1) 158-162 (1998).
-
(1998)
Anal. Chem.
, vol.70
, Issue.1
, pp. 158-162
-
-
Waters, L.C.1
Jacobson, S.C.2
Kroutchinina, N.3
Khandurina, J.4
Foote, R.S.5
Ramsey, J.M.6
-
26
-
-
0033951040
-
Anchored multiplex amplification on a microelectronic chip array
-
Westin L, Xu X, Miller C, Wang L, Edman CF, Nerenberg M. Anchored multiplex amplification on a microelectronic chip array. Nature Biotechnol. 18(2) 199-204 (2000).
-
(2000)
Nature Biotechnol.
, vol.18
, Issue.2
, pp. 199-204
-
-
Westin, L.1
Xu, X.2
Miller, C.3
Wang, L.4
Edman, C.F.5
Nerenberg, M.6
-
27
-
-
0033780280
-
Pathogen analysis and genetic predisposition testing using microelectronic arrays and isothermal amplification
-
Edman CF, Mehta P, Press R, Spargo CA, Walker GT, Nerenberg M. Pathogen analysis and genetic predisposition testing using microelectronic arrays and isothermal amplification. J. Investig. Med. 48(2), 93-101 (2000).
-
(2000)
J. Investig. Med.
, vol.48
, Issue.2
, pp. 93-101
-
-
Edman, C.F.1
Mehta, P.2
Press, R.3
Spargo, C.A.4
Walker, G.T.5
Nerenberg, M.6
-
28
-
-
0035090330
-
Antimicrobial resistance and bacterial identification utilizing a microelectronic chip array
-
Westin L, Miller C, Vollmer D et al. Antimicrobial resistance and bacterial identification utilizing a microelectronic chip array. J. Clin. Microbiol. 39(3), 1097-1104 (2001).
-
(2001)
J. Clin. Microbiol.
, vol.39
, Issue.3
, pp. 1097-1104
-
-
Westin, L.1
Miller, C.2
Vollmer, D.3
-
29
-
-
0032534772
-
Multiple sample PCR amplification and electrophoretic analysis on a microchip
-
Waters LC, Jacobson SC, Kroutchinina N, Khandurina J, Foote RS, Ramsey JM. Multiple sample PCR amplification and electrophoretic analysis on a microchip. Anal. Chem. 70(24), 5172-5176 (1998).
-
(1998)
Anal. Chem.
, vol.70
, Issue.24
, pp. 5172-5176
-
-
Waters, L.C.1
Jacobson, S.C.2
Kroutchinina, N.3
Khandurina, J.4
Foote, R.S.5
Ramsey, J.M.6
-
30
-
-
0034235973
-
Integrated system for rapid PCR-based DNA analysis in microfluidic devices
-
Khandurina J, McKnight TE, Jacobson SC, Waters LC, Foote RS, Ramsey JM. Integrated system for rapid PCR-based DNA analysis in microfluidic devices. Anal. Chem. 72(13), 2995-3000 (2000).
-
(2000)
Anal. Chem.
, vol.72
, Issue.13
, pp. 2995-3000
-
-
Khandurina, J.1
McKnight, T.E.2
Jacobson, S.C.3
Waters, L.C.4
Foote, R.S.5
Ramsey, J.M.6
-
31
-
-
0029989857
-
Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device
-
Woolley AT, Hadley D, Landre P, deMello AJ, Mathies RA, Northrup MA. Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device. Anal. Chem. 68(23), 4081-4086 (1996).
-
(1996)
Anal. Chem.
, vol.68
, Issue.23
, pp. 4081-4086
-
-
Woolley, A.T.1
Hadley, D.2
Landre, P.3
DeMello, A.J.4
Mathies, R.A.5
Northrup, M.A.6
-
32
-
-
0034661580
-
Eight hundred-base sequencing in a microfabricated electrophoretic device
-
Koutny L, Schmalzing D, Salas-Solano O et al. Eight hundred-base sequencing in a microfabricated electrophoretic device. Anal. Chem. 72(14), 3388-33891 (2000).
-
(2000)
Anal. Chem.
, vol.72
, Issue.14
, pp. 3388-33891
-
-
Koutny, L.1
Schmalzing, D.2
Salas-Solano, O.3
-
33
-
-
0033989339
-
DNA sequencing in a monolithic microchannel device
-
Backhouse C, Caamano M, Oaks F et al. DNA sequencing in a monolithic microchannel device. Electrophoresis 21(1), 150-156 (2000).
-
(2000)
Electrophoresis
, vol.21
, Issue.1
, pp. 150-156
-
-
Backhouse, C.1
Caamano, M.2
Oaks, F.3
-
34
-
-
0034625041
-
Automated parallel DNA sequencing on multiple channel microchips
-
Liu S, Ren H, Gao Q et al. Automated parallel DNA sequencing on multiple channel microchips. Proc. Natl Acad. Sci. USA 97(10), 5369-5374 (2000).
-
(2000)
Proc. Natl. Acad. Sci. USA
, vol.97
, Issue.10
, pp. 5369-5374
-
-
Liu, S.1
Ren, H.2
Gao, Q.3
-
35
-
-
0032894286
-
A highly sensitive assay for detection and qualification of human cytomegalovirus DNA in serum and plasma by PCR and electrochemiluminescence
-
Boom R, Sol C, Weel J, Gerrits Y, de Boer M, Wertheim-van Dillen P. A highly sensitive assay for detection and qualification of human cytomegalovirus DNA in serum and plasma by PCR and electrochemiluminescence. J. Clin. Microbiol. 37(5), 1489-1497 (1999).
-
(1999)
J. Clin. Microbiol.
, vol.37
, Issue.5
, pp. 1489-1497
-
-
Boom, R.1
Sol, C.2
Weel, J.3
Gerrits, Y.4
De Boer, M.5
Wertheim-van Dillen, P.6
-
36
-
-
0032001616
-
Capillary electrophoresis chips with integrated electrochemical detection
-
Woolley AT, Lao K, Glazer AN, Mathies RA. Capillary electrophoresis chips with integrated electrochemical detection. Anal. Chem. 70(4), 684-688 (1998).
-
(1998)
Anal. Chem.
, vol.70
, Issue.4
, pp. 684-688
-
-
Woolley, A.T.1
Lao, K.2
Glazer, A.N.3
Mathies, R.A.4
-
37
-
-
0033766119
-
Evaluation of DNA fragment sizing and quantification by the Agilent 2100 bioanalyzer
-
Panaro NJ, Yuen PK, Sakazume T, Fortina P, Kricka LJ, Wilding P. Evaluation of DNA fragment sizing and quantification by the Agilent 2100 bioanalyzer. Clin. Chem. 46(11), 1851-1853 (2000).
-
(2000)
Clin. Chem.
, vol.46
, Issue.11
, pp. 1851-1853
-
-
Panaro, N.J.1
Yuen, P.K.2
Sakazume, T.3
Fortina, P.4
Kricka, L.J.5
Wilding, P.6
-
38
-
-
0034908917
-
Microfluidics-downsizing large-scale biology
-
Mitchell P. Microfluidics-downsizing large-scale biology. Nature Biotechnol. 19(8), 717-721 (2001). • Description of commercial products available on the market for DNA analysis.
-
(2001)
Nature Biotechnol.
, vol.19
, Issue.8
, pp. 717-721
-
-
Mitchell, P.1
-
39
-
-
0036073163
-
Analysis of DNA polymorphisms on the human Y-chromosome by microchip electrophoresis
-
Jabasini M, Zhang L, Dang F et al. Analysis of DNA polymorphisms on the human Y-chromosome by microchip electrophoresis. Electrophoresis 23(10), 1537-1542 (2002).
-
(2002)
Electrophoresis
, vol.23
, Issue.10
, pp. 1537-1542
-
-
Jabasini, M.1
Zhang, L.2
Dang, F.3
-
40
-
-
0036190601
-
Detection of DNA mutations associated with mitochondrial diseases by Agilent 2100 bioanalyzer
-
Lu CY, Tso DJ, Yang T, Jong YJ, Wei YH. Detection of DNA mutations associated with mitochondrial diseases by Agilent 2100 bioanalyzer. Clin. Chim. Acta 318(1-2), 97-105 (2002).
-
(2002)
Clin. Chim. Acta
, vol.318
, Issue.1-2
, pp. 97-105
-
-
Lu, C.Y.1
Tso, D.J.2
Yang, T.3
Jong, Y.J.4
Wei, Y.H.5
-
41
-
-
0034767094
-
Semiquantitative reverse transcription-polymerase chain reaction with the Agilent 2100 Bioanalyzer
-
Gottwald E, Muller O, Polten A. Semiquantitative reverse transcription-polymerase chain reaction with the Agilent 2100 Bioanalyzer. Electrophoresis 22(18), 4016-4022 (2001).
-
(2001)
Electrophoresis
, vol.22
, Issue.18
, pp. 4016-4022
-
-
Gottwald, E.1
Muller, O.2
Polten, A.3
-
42
-
-
0035846985
-
Fluid control in multichannel structures by electrocapillary pressure
-
Prins MW, Welters WJ, Weekamp JW. Fluid control in multichannel structures by electrocapillary pressure. Science 291(5502), 277-280 (2001).
-
(2001)
Science
, vol.291
, Issue.5502
, pp. 277-280
-
-
Prins, M.W.1
Welters, W.J.2
Weekamp, J.W.3
-
43
-
-
0036672773
-
Evaluation of nanopores as candidates for electronic analyte detection
-
Nakane J, Akeson M, Marziali A. Evaluation of nanopores as candidates for electronic analyte detection. Electrophoresis 23(16), 2592-2601 (2002).
-
(2002)
Electrophoresis
, vol.23
, Issue.16
, pp. 2592-2601
-
-
Nakane, J.1
Akeson, M.2
Marziali, A.3
-
44
-
-
0034050876
-
Ion channels as molecular coulter counters to probe metabolite transport
-
Bezrukov SM. Ion channels as molecular coulter counters to probe metabolite transport. J. Membr. Biol. 174(1), 1-13 (2000).
-
(2000)
J. Membr. Biol.
, vol.174
, Issue.1
, pp. 1-13
-
-
Bezrukov, S.M.1
-
45
-
-
0033980542
-
Rapid nanopore discrimination between single polynucleotide molecules
-
Meller A, Nivon L, Brandin E, Golovchenko J, Branton D. Rapid nanopore discrimination between single polynucleotide molecules. Proc. Natl Acad. Sci. USA 97(3), 1079-1084 (2000).
-
(2000)
Proc. Natl Acad. Sci. USA
, vol.97
, Issue.3
, pp. 1079-1084
-
-
Meller, A.1
Nivon, L.2
Brandin, E.3
Golovchenko, J.4
Branton, D.5
-
46
-
-
0036910652
-
Active microelectronic array system for DNA hybridization, genotyping and pharmacogenomic applications
-
Sosnowski R, Heller MJ, Tu E, Forster AH, Radtkey R. Active microelectronic array system for DNA hybridization, genotyping and pharmacogenomic applications. Psychiatr. Genet. 12(4), 181-192 (2002) • Innovative application of microelectronics to DNA variation detection.
-
(2002)
Psychiatr. Genet.
, vol.12
, Issue.4
, pp. 181-192
-
-
Sosnowski, R.1
Heller, M.J.2
Tu, E.3
Forster, A.H.4
Radtkey, R.5
-
47
-
-
0032892409
-
Single nucleotide polymorphic discrimination by an electronic dot blot assay on semiconductor microchips
-
Gilles PN, Wu DJ, Foster CB, Dillon PJ, Chanock SJ. Single nucleotide polymorphic discrimination by an electronic dot blot assay on semiconductor microchips. Nature Biotechnol. 17(4), 365-370 (1999).
-
(1999)
Nature Biotechnol.
, vol.17
, Issue.4
, pp. 365-370
-
-
Gilles, P.N.1
Wu, D.J.2
Foster, C.B.3
Dillon, P.J.4
Chanock, S.J.5
-
48
-
-
0037406453
-
Evaluation of electronic microarrays for genotyping Factor V, Factor II, and MTHFR
-
Erali M, Schmidt B, Lyon E, Wittwer C. Evaluation of electronic microarrays for genotyping Factor V, Factor II, and MTHFR. Clin. Chem. 49(5), 732-739 (2003).
-
(2003)
Clin. Chem.
, vol.49
, Issue.5
, pp. 732-739
-
-
Erali, M.1
Schmidt, B.2
Lyon, E.3
Wittwer, C.4
-
49
-
-
0036839857
-
Multiplexed, targeted gene expression profiling and genetic analysis on electronic microarrays
-
Weidenhammer EM, Kahl BF, Wang L et al. Multiplexed, targeted gene expression profiling and genetic analysis on electronic microarrays. Clin. Chem. 48(11), 1873-1882 (2002).
-
(2002)
Clin. Chem.
, vol.48
, Issue.11
, pp. 1873-1882
-
-
Weidenhammer, E.M.1
Kahl, B.F.2
Wang, L.3
-
50
-
-
1642492777
-
Beta-thalassemia microelectronic chip: A fast and accurate method for mutation detection
-
Foglieni B, Cremonesi L, Travi M et al. Beta-thalassemia microelectronic chip: a fast and accurate method for mutation detection. Clin. Chem. 50(1), 73-79 (2004).
-
(2004)
Clin. Chem.
, vol.50
, Issue.1
, pp. 73-79
-
-
Foglieni, B.1
Cremonesi, L.2
Travi, M.3
-
51
-
-
0742321919
-
Nanogen microelectronic chip for large-scale genotyping
-
Sethi AA, Tybjaerg-Hansen A, Andersen RV, Nordestgaard BG. Nanogen microelectronic chip for large-scale genotyping. Clin. Chem. 50(2), 443-446 (2004).
-
(2004)
Clin. Chem.
, vol.50
, Issue.2
, pp. 443-446
-
-
Sethi, A.A.1
Tybjaerg-Hansen, A.2
Andersen, R.V.3
Nordestgaard, B.G.4
-
52
-
-
0141754000
-
Microarray and microfluidic methodology for genotyping cytokine gene polymorphisms
-
Sohni YR, Cerhan JR, O'Kane D. Microarray and microfluidic methodology for genotyping cytokine gene polymorphisms. Hum. Immunol. 64(10), 990-997 (2003).
-
(2003)
Hum. Immunol.
, vol.64
, Issue.10
, pp. 990-997
-
-
Sohni, Y.R.1
Cerhan, J.R.2
O'Kane, D.3
-
53
-
-
0036892135
-
Analysis of clinically relevant single-nucleotide polymorphisms by use of microelectronic array technology
-
Santacroce R, Ratti A, Caroli F et al. Analysis of clinically relevant single-nucleotide polymorphisms by use of microelectronic array technology. Clin. Chem. 48(12), 2124-2130 (2002).
-
(2002)
Clin. Chem.
, vol.48
, Issue.12
, pp. 2124-2130
-
-
Santacroce, R.1
Ratti, A.2
Caroli, F.3
-
54
-
-
0036310989
-
N-acetyltransferase 1 and 2 genotypes do not predict response or toxicity to treatment with mesalamine and sulfasalazine in patients with ulcerative colitis
-
Ricart E, Taylor WR, Loftus EV et al. N-acetyltransferase 1 and 2 genotypes do not predict response or toxicity to treatment with mesalamine and sulfasalazine in patients with ulcerative colitis. Am. J. Gastroenterol. 97(7), 1763-1768 (2002).
-
(2002)
Am. J. Gastroenterol.
, vol.97
, Issue.7
, pp. 1763-1768
-
-
Ricart, E.1
Taylor, W.R.2
Loftus, E.V.3
-
55
-
-
0036972918
-
Single nucleotide polymorphisms and mutation identification by miocroelectronic chip technology
-
Stenirri S, Foglieni B, Manitto MP et al. Single nucleotide polymorphisms and mutation identification by miocroelectronic chip technology. Minerva Biotecnologica 14(3-4), 241-246 (2002).
-
(2002)
Minerva Biotecnologica
, vol.14
, Issue.3-4
, pp. 241-246
-
-
Stenirri, S.1
Foglieni, B.2
Manitto, M.P.3
-
56
-
-
0037099076
-
Rapid parallel mutation scanning of gene fragments using a microelectronic protein-DNA chip format
-
Behrensdorf HA, Pignot M, Windhab N, Kappel A. Rapid parallel mutation scanning of gene fragments using a microelectronic protein-DNA chip format. Nucleic Acids Res. 30(14), E64 (2002).
-
(2002)
Nucleic Acids Res.
, vol.30
, Issue.14
-
-
Behrensdorf, H.A.1
Pignot, M.2
Windhab, N.3
Kappel, A.4
-
57
-
-
0034164575
-
Rapid, high fidelity analysis of simple sequence repeats on an electronically active DNA microchip
-
Radtkey R, Feng L, Muralhidar M et al. Rapid, high fidelity analysis of simple sequence repeats on an electronically active DNA microchip. Nucleic Acids Res. 28(7), E17 (2000).
-
(2000)
Nucleic Acids Res.
, vol.28
, Issue.7
-
-
Radtkey, R.1
Feng, L.2
Muralhidar, M.3
-
58
-
-
0035865410
-
Detection of biological toxins on an active electronic microchip
-
Ewalt KL, Haigis RW, Rooney R, Ackley D, Krihak M. Detection of biological toxins on an active electronic microchip. Anal. Biochem. 289(2), 162-172 (2001).
-
(2001)
Anal. Biochem.
, vol.289
, Issue.2
, pp. 162-172
-
-
Ewalt, K.L.1
Haigis, R.W.2
Rooney, R.3
Ackley, D.4
Krihak, M.5
-
59
-
-
0037178193
-
An integrated, stacked microlaboratory for biological agent detection with DNA and immunoassays
-
Yang JM, Bell J, Huang Y et al. An integrated, stacked microlaboratory for biological agent detection with DNA and immunoassays. Biosens. Bioelectron. 17(6-7), 605-618 (2002)
-
(2002)
Biosens. Bioelectron.
, vol.17
, Issue.6-7
, pp. 605-618
-
-
Yang, J.M.1
Bell, J.2
Huang, Y.3
-
60
-
-
0034827540
-
Bioelectronic DNA chips for the clinical laboratory
-
Farkas DH. Bioelectronic DNA chips for the clinical laboratory. Clin. Chem. 47(10), 1871-1872 (2001).
-
(2001)
Clin. Chem.
, vol.47
, Issue.10
, pp. 1871-1872
-
-
Farkas, D.H.1
-
61
-
-
7044264053
-
Plastic biochannel hybridization devices: A new concept for microfluidic DNA arrays
-
Lenigk R, Liu RH, Athavale M et al. Plastic biochannel hybridization devices: a new concept for microfluidic DNA arrays. Anal. Biochem. 311(1), 40-49 (2002).
-
(2002)
Anal. Biochem.
, vol.311
, Issue.1
, pp. 40-49
-
-
Lenigk, R.1
Liu, R.H.2
Athavale, M.3
-
62
-
-
0035014156
-
Electronic detection of nucleic acids: A versatile platform for molecular diagnostics
-
Umek RM, Lin SW, Vielmetter J et al. Electronic detection of nucleic acids: a versatile platform for molecular diagnostics. J. Mol. Diagn. 3(2), 74-84 (2001).
-
(2001)
J. Mol. Diagn.
, vol.3
, Issue.2
, pp. 74-84
-
-
Umek, R.M.1
Lin, S.W.2
Vielmetter, J.3
-
63
-
-
0344737857
-
Bioelectronic sensor technology for detection of cystic fibrosis and hereditary hemochromatosis mutations
-
Bernacki SH, Farkas DH, Shi W et al. Bioelectronic sensor technology for detection of cystic fibrosis and hereditary hemochromatosis mutations. Arch. Pathol. Lab. Med. 127(12), 1565-1572 (2003).
-
(2003)
Arch. Pathol. Lab. Med.
, vol.127
, Issue.12
, pp. 1565-1572
-
-
Bernacki, S.H.1
Farkas, D.H.2
Shi, W.3
-
64
-
-
0032449993
-
Conducting polymers on microelectronic devices as tools for biological analyses
-
Livache T, Bazin H, Mathis G. Conducting polymers on microelectronic devices as tools for biological analyses. Clin. Chim. Acta. 278(2), 171-176 (1998).
-
(1998)
Clin. Chim. Acta
, vol.278
, Issue.2
, pp. 171-176
-
-
Livache, T.1
Bazin, H.2
Mathis, G.3
-
65
-
-
0032518345
-
Polypyrrole DNA chip on a silicon device: Example of hepatitis C virus genotyping
-
Livache T, Fouque B, Roget A et al. Polypyrrole DNA chip on a silicon device: example of hepatitis C virus genotyping. Anal. Biochem. 255(2), 188-194 (1998).
-
(1998)
Anal. Biochem.
, vol.255
, Issue.2
, pp. 188-194
-
-
Livache, T.1
Fouque, B.2
Roget, A.3
-
66
-
-
0034921097
-
Microchip isoelectric focusing using a miniature scanning detection system
-
Raisi F, Belgrader P, Borkholder DA et al. Microchip isoelectric focusing using a miniature scanning detection system. Electrophoresis 22(11) 2291-2295 (2001).
-
(2001)
Electrophoresis
, vol.22
, Issue.11
, pp. 2291-2295
-
-
Raisi, F.1
Belgrader, P.2
Borkholder, D.A.3
-
67
-
-
0033075072
-
Rapid, automated nucleic acid probe assays using silicon microstructures for nucleic acid concentration
-
Christel LA, Petersen K, McMillan W, Northrup MA. Rapid, automated nucleic acid probe assays using silicon microstructures for nucleic acid concentration. J. Biomech. Eng. 121(1), 22-27 (1999).
-
(1999)
J. Biomech. Eng.
, vol.121
, Issue.1
, pp. 22-27
-
-
Christel, L.A.1
Petersen, K.2
McMillan, W.3
Northrup, M.A.4
-
68
-
-
0035863675
-
A battery-powered notebook thermal cycler for rapid multiplex real-time PCR analysis
-
Belgrader P, Young S, Yuan B et al. A battery-powered notebook thermal cycler for rapid multiplex real-time PCR analysis. Anal. Chem. 73(2), 286-289 (2001).
-
(2001)
Anal. Chem.
, vol.73
, Issue.2
, pp. 286-289
-
-
Belgrader, P.1
Young, S.2
Yuan, B.3
-
69
-
-
0034663496
-
From DNA biosensors to gene chips
-
Wang J. From DNA biosensors to gene chips. Nucleic Acids Res. 28(16), 3011-3016 (2000). • Examines different strategies for DNA biosensors and gene chips and shows future trends of the field.
-
(2000)
Nucleic Acids Res.
, vol.28
, Issue.16
, pp. 3011-3016
-
-
Wang, J.1
-
70
-
-
0141765878
-
Electrochemical DNA sensors
-
Drummond TG, Hill MG, Barton JK. Electrochemical DNA sensors. Nature Biotechnol. 21(10), 1192-1199 (2003). •• Excellent review on all DNA biosensor principles.
-
(2003)
Nature Biotechnol.
, vol.21
, Issue.10
, pp. 1192-1199
-
-
Drummond, T.G.1
Hill, M.G.2
Barton, J.K.3
-
71
-
-
0037179938
-
Electrochemical nucleic acid biosensors
-
Wang J. Electrochemical nucleic acid biosensors. Anal. Chim. Acta. 469, 63-71 (2002).
-
(2002)
Anal. Chim. Acta
, vol.469
, pp. 63-71
-
-
Wang, J.1
-
72
-
-
0037195169
-
Electronic detection of DNA by its intrinsic molecular charge
-
Fritz J, Cooper EB, Gaudet S, Sorger PK, Manalis SR. Electronic detection of DNA by its intrinsic molecular charge. Proc. Natl Acad. Sci. USA 99(22), 14142-14146 (2002).
-
(2002)
Proc. Natl Acad. Sci. USA
, vol.99
, Issue.22
, pp. 14142-14146
-
-
Fritz, J.1
Cooper, E.B.2
Gaudet, S.3
Sorger, P.K.4
Manalis, S.R.5
-
73
-
-
0033772184
-
Mutation detection by electrocatalysis at DNA-modified electrodes
-
Boon EM, Ceres DM, Drummond TG, Hill MG, Barton JK. Mutation detection by electrocatalysis at DNA-modified electrodes. Nature Biotechnol. 18(10), 1096-1100 (2000).
-
(2000)
Nature Biotechnol.
, vol.18
, Issue.10
, pp. 1096-1100
-
-
Boon, E.M.1
Ceres, D.M.2
Drummond, T.G.3
Hill, M.G.4
Barton, J.K.5
-
74
-
-
0033200394
-
Site-selective electron transfer from purines to electrocatalysts: Voltammetric detection of a biologically relevant deletion in hybridized DNA duplexes
-
Ropp PA, Thorp HH. Site-selective electron transfer from purines to electrocatalysts: voltammetric detection of a biologically relevant deletion in hybridized DNA duplexes. Chem. Biol. 6(9) 599-605 (1999).
-
(1999)
Chem. Biol.
, vol.6
, Issue.9
, pp. 599-605
-
-
Ropp, P.A.1
Thorp, H.H.2
-
75
-
-
0036896791
-
Allele-specific genotype detection of Factor V Leiden mutation from polymerase chain reaction amplicons based on label-free electrochemical genosensor
-
Ozkan D, Erdem A, Kara P et al. Allele-specific genotype detection of Factor V Leiden mutation from polymerase chain reaction amplicons based on label-free electrochemical genosensor. Anal. Chem. 74(23), 5931-5936 (2002).
-
(2002)
Anal. Chem.
, vol.74
, Issue.23
, pp. 5931-5936
-
-
Ozkan, D.1
Erdem, A.2
Kara, P.3
-
76
-
-
2042526027
-
Voltammetry of osmium-modified DNA at a mercury film electrode: Application in detecting DNA hybridization
-
Kostecka P, Havran L, Pivonkova H, Fojta M. Voltammetry of osmium-modified DNA at a mercury film electrode: application in detecting DNA hybridization. Bioelectrochemistry 63(1-2), 245-248 (2004).
-
(2004)
Bioelectrochemistry
, vol.63
, Issue.1-2
, pp. 245-248
-
-
Kostecka, P.1
Havran, L.2
Pivonkova, H.3
Fojta, M.4
-
78
-
-
0038397433
-
Electrochemical DNA sensor for detection of single nucleotide polymorphisms
-
Marques LP, Cavaco I, Pinheiro JP, Ribeiro V, Ferreira GN. Electrochemical DNA sensor for detection of single nucleotide polymorphisms. Clin. Chem. Lab. Med. 41(4), 475-481 (2003).
-
(2003)
Clin. Chem. Lab. Med.
, vol.41
, Issue.4
, pp. 475-481
-
-
Marques, L.P.1
Cavaco, I.2
Pinheiro, J.P.3
Ribeiro, V.4
Ferreira, G.N.5
|