-
3
-
-
0031226596
-
Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 Cases in 10 dogs (1991-1995)
-
Edwards MR, Egger EL, Schwarz PD: Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995). J Am Vet Med Assoc 211:580-586, 1997
-
(1997)
J Am Vet Med Assoc
, vol.211
, pp. 580-586
-
-
Edwards, M.R.1
Egger, E.L.2
Schwarz, P.D.3
-
4
-
-
0026760296
-
Aseptic loosening of the femoral component in cemented total hip replacement
-
Jones PR, Hukins DW, Porter ML, et al: Aseptic loosening of the femoral component in cemented total hip replacement. J Biomed Eng 14:379-384, 1992
-
(1992)
J Biomed Eng
, vol.14
, pp. 379-384
-
-
Jones, P.R.1
Hukins, D.W.2
Porter, M.L.3
-
5
-
-
0028214666
-
The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results
-
Ebramzadeh E, Sarmiento A, McKellop HA, et al: The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results. J Bone Joint Surg Am 76:77-87, 1994
-
(1994)
J Bone Joint Surg Am
, vol.76
, pp. 77-87
-
-
Ebramzadeh, E.1
Sarmiento, A.2
McKellop, H.A.3
-
6
-
-
0029334356
-
The effects of implant orientation, canal fill, and implant fit on femoral strain patterns and implant stability during catastrophic testing of a canine cementless femoral prosthesis
-
Pernell RT, Milton JL, Gross RS, et al: The effects of implant orientation, canal fill, and implant fit on femoral strain patterns and implant stability during catastrophic testing of a canine cementless femoral prosthesis. Vet Surg 24:337-346, 1995
-
(1995)
Vet Surg
, vol.24
, pp. 337-346
-
-
Pernell, R.T.1
Milton, J.L.2
Gross, R.S.3
-
7
-
-
0018877406
-
The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction
-
Crowninshield RD, Brand RA, Johnston RC, et al: The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction. Clin Orthop 146:71-77, 1980
-
(1980)
Clin Orthop
, vol.146
, pp. 71-77
-
-
Crowninshield, R.D.1
Brand, R.A.2
Johnston, R.C.3
-
8
-
-
0018838788
-
An analysis of femoral component stem design in total hip arthroplasty
-
Crowninshield RD, Brand RA, Johnston RC, et al: An analysis of femoral component stem design in total hip arthroplasty. J Bone Joint Surg Am 62:68-78, 1980
-
(1980)
J Bone Joint Surg Am
, vol.62
, pp. 68-78
-
-
Crowninshield, R.D.1
Brand, R.A.2
Johnston, R.C.3
-
9
-
-
0028197479
-
Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization
-
Star MJ, Colwell CW, Jr., Kelman GJ, et al: Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization. J Arthroplasty 9:143-149, 1994
-
(1994)
J Arthroplasty
, vol.9
, pp. 143-149
-
-
Star, M.J.1
Colwell Jr., C.W.2
Kelman, G.J.3
-
10
-
-
0027732951
-
Mechanical failure of the femoral component in cemented total hip replacement - A finite element evaluation
-
Jansson V, Refior HJ: Mechanical failure of the femoral component in cemented total hip replacement - A finite element evaluation. Arch Orthop Trauma Surg 113:23-27, 1993
-
(1993)
Arch Orthop Trauma Surg
, vol.113
, pp. 23-27
-
-
Jansson, V.1
Refior, H.J.2
-
11
-
-
0027418684
-
Stress transfer at the femoral bone/bone cement interface as a function of the cement thickness
-
Jansson V, Heimkes B, Zimmer M: Stress transfer at the femoral bone/bone cement interface as a function of the cement thickness. Arch Orthop Trauma Surg 112:65-68, 1993
-
(1993)
Arch Orthop Trauma Surg
, vol.112
, pp. 65-68
-
-
Jansson, V.1
Heimkes, B.2
Zimmer, M.3
-
12
-
-
0031043430
-
Factors affecting cement strains near the tip of a cemented femoral component
-
Estok DM II, Orr TE, Harris WH: Factors affecting cement strains near the tip of a cemented femoral component. J Arthroplasty 12:40-48, 1997
-
(1997)
J Arthroplasty
, vol.12
, pp. 40-48
-
-
Estok II, D.M.1
Orr, T.E.2
Harris, W.H.3
-
13
-
-
0027902464
-
Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant
-
Lee IY, Skinner HB, Keyak JH: Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant. Iowa Orthop J 13:155-159, 1993
-
(1993)
Iowa Orthop J
, vol.13
, pp. 155-159
-
-
Lee, I.Y.1
Skinner, H.B.2
Keyak, J.H.3
-
14
-
-
0028500672
-
Effects of variation of prosthesis size on cement stress at the tip of a femoral implant
-
Lee IY, Skinner HB, Keyak JH: Effects of variation of prosthesis size on cement stress at the tip of a femoral implant. J Biomed Mater Res 28:1055-1060, 1994
-
(1994)
J Biomed Mater Res
, vol.28
, pp. 1055-1060
-
-
Lee, I.Y.1
Skinner, H.B.2
Keyak, J.H.3
-
15
-
-
0022097380
-
An experimental study of femoral cement stress in total hip replacement - Influence of structural stiffness of the femoral stem
-
Miles AW, Dall DM: An experimental study of femoral cement stress in total hip replacement - Influence of structural stiffness of the femoral stem. Eng Med 14:133-135, 1985
-
(1985)
Eng Med
, vol.14
, pp. 133-135
-
-
Miles, A.W.1
Dall, D.M.2
-
16
-
-
0031668067
-
Effects of distal cement voids on cement stress in total hip arthroplasty
-
Powers CM, Lee IY, Skinner HB, et al: Effects of distal cement voids on cement stress in total hip arthroplasty. J Arthroplasty 13:793-798, 1998
-
(1998)
J Arthroplasty
, vol.13
, pp. 793-798
-
-
Powers, C.M.1
Lee, I.Y.2
Skinner, H.B.3
-
17
-
-
0019962848
-
A ten-year follow-up of one hundred consecutive Muller curved-stem total hip-replacement arthroplasties
-
Sutherland CJ, Wilde AH, Borden LS, et al: A ten-year follow-up of one hundred consecutive Muller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64:970-982, 1982
-
(1982)
J Bone Joint Surg Am
, vol.64
, pp. 970-982
-
-
Sutherland, C.J.1
Wilde, A.H.2
Borden, L.S.3
-
18
-
-
0025334126
-
Improved positioning of the femoral stem with a centralizing device
-
Egund N, Lidgren L, Onnerfalt R: Improved positioning of the femoral stem with a centralizing device. Acta Orthop Scand 61:236-239, 1990
-
(1990)
Acta Orthop Scand
, vol.61
, pp. 236-239
-
-
Egund, N.1
Lidgren, L.2
Onnerfalt, R.3
-
19
-
-
0033194353
-
Effect of surgical technique and use of a rigid centralizing device on stem positioning and geometric reconstruction in the sagittal plane during total hip replacement in canine cadavers
-
Schulz KS, Stover SM, Kass PH, et al: Effect of surgical technique and use of a rigid centralizing device on stem positioning and geometric reconstruction in the sagittal plane during total hip replacement in canine cadavers. Am J Vet Res 60:1126-1135, 1999
-
(1999)
Am J Vet Res
, vol.60
, pp. 1126-1135
-
-
Schulz, K.S.1
Stover, S.M.2
Kass, P.H.3
-
20
-
-
0032135390
-
Transverse plane evaluation of the effects of surgical technique on stem positioning and geometry of reconstruction in canine total hip replacement
-
Schulz KS, Vasseur PB, Stover SM, et al: Transverse plane evaluation of the effects of surgical technique on stem positioning and geometry of reconstruction in canine total hip replacement. Am J Vet Res 59:1071-1079, 1998
-
(1998)
Am J Vet Res
, vol.59
, pp. 1071-1079
-
-
Schulz, K.S.1
Vasseur, P.B.2
Stover, S.M.3
-
21
-
-
0034184675
-
Femoral medullary infarction secondary to canine total hip arthroplasty
-
Sebestyen P, Marcellin-Little DJ, DeYoung BA: Femoral medullary infarction secondary to canine total hip arthroplasty. Vet Surg 29:227-236, 2000
-
(2000)
Vet Surg
, vol.29
, pp. 227-236
-
-
Sebestyen, P.1
Marcellin-Little, D.J.2
DeYoung, B.A.3
-
22
-
-
0002506538
-
Biomechanics of artificial joints: The hip
-
Mow VC, Hayes WC (eds): Philadelphia, PA, Lippincott-Raven
-
Huiskes R, Verdonschot N: Biomechanics of artificial joints: The hip, in Mow VC, Hayes WC (eds): Basic Orthopaedic Biomechanics (ed 2). Philadelphia, PA, Lippincott-Raven, 1997, pp 395-460
-
(1997)
Basic Orthopaedic Biomechanics (Ed 2)
, pp. 395-460
-
-
Huiskes, R.1
Verdonschot, N.2
-
23
-
-
0021412468
-
Mechanical properties of bone cement: A review
-
Saha S, Pal S: Mechanical properties of bone cement: A review. J Biomed Mater Res 18:435-462, 1984
-
(1984)
J Biomed Mater Res
, vol.18
, pp. 435-462
-
-
Saha, S.1
Pal, S.2
-
24
-
-
0023279332
-
The mechanical properties of cement and loosening of the femoral component of hip replacements
-
Weightman B, Freeman MA, Revell PA, et al: The mechanical properties of cement and loosening of the femoral component of hip replacements. J Bone Joint Surg Br 69:558-564, 1987
-
(1987)
J Bone Joint Surg Br
, vol.69
, pp. 558-564
-
-
Weightman, B.1
Freeman, M.A.2
Revell, P.A.3
-
25
-
-
0023421211
-
Comparison of the fatigue characteristics of centrifuged and uncentrifuged simplex p bone cement
-
Davies JP, Burke DW, O'Connor DO, et al: Comparison of the fatigue characteristics of centrifuged and uncentrifuged simplex p bone cement. J Orthop Res 5:366-371, 1987
-
(1987)
J Orthop Res
, vol.5
, pp. 366-371
-
-
Davies, J.P.1
Burke, D.W.2
O'Connor, D.O.3
-
26
-
-
0027533403
-
Fatigue failure in the cement mantle of an artificial hip joint
-
Culleton P, Prendergast PJ, Taylor D: Fatigue failure in the cement mantle of an artificial hip joint. Clin Mater 12:95-102, 1993
-
(1993)
Clin Mater
, vol.12
, pp. 95-102
-
-
Culleton, P.1
Prendergast, P.J.2
Taylor, D.3
-
27
-
-
0025784682
-
The initiation of failure in cemented femoral components of hip arthroplasties
-
Jasty M, Maloney WJ, Bragdon CR, et al: The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg Br 73:551-558, 1991
-
(1991)
J Bone Joint Surg Br
, vol.73
, pp. 551-558
-
-
Jasty, M.1
Maloney, W.J.2
Bragdon, C.R.3
-
28
-
-
0019981269
-
Ten-year follow-up study of total hip replacement
-
Stauffer RN: Ten-year follow-up study of total hip replacement. J Bone Joint Surg Am 64:983-990, 1982
-
(1982)
J Bone Joint Surg Am
, vol.64
, pp. 983-990
-
-
Stauffer, R.N.1
-
29
-
-
0030250742
-
In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing
-
O'Connor DO, Burke DW, Jasty M, et al: In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing. J Orthop Res 14:769-777, 1996
-
(1996)
J Orthop Res
, vol.14
, pp. 769-777
-
-
O'Connor, D.O.1
Burke, D.W.2
Jasty, M.3
-
30
-
-
0031792614
-
Importance of a thin cement mantle. Autopsy studies of eight hips
-
Kawate K, Maloney WJ, Bragdon CR, et al: Importance of a thin cement mantle. Autopsy studies of eight hips. Clin Orthop 355:70-76, 1998
-
(1998)
Clin Orthop
, vol.355
, pp. 70-76
-
-
Kawate, K.1
Maloney, W.J.2
Bragdon, C.R.3
-
31
-
-
0031278698
-
Cement-mantle thickness affects cement strains in total hip replacement
-
Fisher DA, Tsang AC, Paydar N, et al: Cement-mantle thickness affects cement strains in total hip replacement. J Biomech 30:1173-1177, 1997
-
(1997)
J Biomech
, vol.30
, pp. 1173-1177
-
-
Fisher, D.A.1
Tsang, A.C.2
Paydar, N.3
-
32
-
-
0031039947
-
Effects of stem length on mechanics of the femoral hip component after cemented revision
-
Mann KA, Ayers DC, Damron TA: Effects of stem length on mechanics of the femoral hip component after cemented revision. J Orthop Res 15:62-68, 1997
-
(1997)
J Orthop Res
, vol.15
, pp. 62-68
-
-
Mann, K.A.1
Ayers, D.C.2
Damron, T.A.3
-
33
-
-
0031765525
-
Cemented femoral stem performance. Effects of proximal bonding, geometry, and neck length
-
Chang PB, Mann KA, Bartel DL: Cemented femoral stem performance. Effects of proximal bonding, geometry, and neck length. Clin Orthop 355:57-69, 1998
-
(1998)
Clin Orthop
, vol.355
, pp. 57-69
-
-
Chang, P.B.1
Mann, K.A.2
Bartel, D.L.3
|