메뉴 건너뛰기




Volumn 13, Issue 7, 1998, Pages 793-798

Effects of distal cement voids on cement stress in total hip arthroplasty

Author keywords

Cement stress; Cement voids; Finite element; Hip arthroplasty

Indexed keywords

ARTICLE; JOINT STABILITY; STRESS STRAIN RELATIONSHIP; TOTAL HIP PROSTHESIS;

EID: 0031668067     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(98)90033-X     Document Type: Article
Times cited : (13)

References (13)
  • 1
    • 0018687995 scopus 로고
    • "Modes of Failure" of cemented stem-type femoral components: A radiological analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC: "Modes of Failure" of cemented stem-type femoral components: a radiological analysis of loosening. Clin Orthop 141:17, 1978
    • (1978) Clin Orthop , vol.141 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 2
    • 0343521109 scopus 로고
    • Mechanical consequences of cement-metal interface disruption (debonding) at the distal tip of femoral total hip prosthesis
    • Harrigan TP, Harris WH: Mechanical consequences of cement-metal interface disruption (debonding) at the distal tip of femoral total hip prosthesis. Trans Orthop Res Soc 16:503, 1991
    • (1991) Trans Orthop Res Soc , vol.16 , pp. 503
    • Harrigan, T.P.1    Harris, W.H.2
  • 3
    • 0026580011 scopus 로고
    • A finite element study of the initiation of failure of fixation in cemented femoral total hip components
    • Harrigan TP, Kareh JA, O'Connor DO, Burke DW, Harris WH: A finite element study of the initiation of failure of fixation in cemented femoral total hip components. J Orthop Res 10:134, 1992
    • (1992) J Orthop Res , vol.10 , pp. 134
    • Harrigan, T.P.1    Kareh, J.A.2    O'Connor, D.O.3    Burke, D.W.4    Harris, W.H.5
  • 4
    • 0026070354 scopus 로고
    • A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components
    • Harrigan TP, Harris WH: A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components. J Biomech 24:1047, 1991
    • (1991) J Biomech , vol.24 , pp. 1047
    • Harrigan, T.P.1    Harris, W.H.2
  • 5
    • 0007535916 scopus 로고
    • Finite element analysis of cement strains at the tip of an idealized cemented femoral component
    • Estok DM, Harrigan TP, Harris WH: Finite element analysis of cement strains at the tip of an idealized cemented femoral component. Trans Orthop Res Soc 16:504, 1991
    • (1991) Trans Orthop Res Soc , vol.16 , pp. 504
    • Estok, D.M.1    Harrigan, T.P.2    Harris, W.H.3
  • 6
    • 0012269139 scopus 로고
    • The strain gradient across the cement mantle in a cemented femoral component, a detailed mapping
    • Estok DM, Orr TE: The strain gradient across the cement mantle in a cemented femoral component, a detailed mapping. Trans Orthop Res Soc 17:371, 1992
    • (1992) Trans Orthop Res Soc , vol.17 , pp. 371
    • Estok, D.M.1    Orr, T.E.2
  • 7
    • 0028500672 scopus 로고
    • Effects of variation of prosthesis size on cement stress at the tip of a femoral implant
    • Lee IY, Skinner HB, Keyak JH: Effects of variation of prosthesis size on cement stress at the tip of a femoral implant. J Biomed Mater Res 28:1055, 1994
    • (1994) J Biomed Mater Res , vol.28 , pp. 1055
    • Lee, I.Y.1    Skinner, H.B.2    Keyak, J.H.3
  • 8
    • 0027168212 scopus 로고
    • Preventing distal voids during cementation of the femoral component in total hip arthroplasty
    • Berger RA, Steel MJ, Schleiden M, Rubash HE: Preventing distal voids during cementation of the femoral component in total hip arthroplasty. J Arthroplasty 8:323, 1993
    • (1993) J Arthroplasty , vol.8 , pp. 323
    • Berger, R.A.1    Steel, M.J.2    Schleiden, M.3    Rubash, H.E.4
  • 9
    • 0028465991 scopus 로고
    • Femoral prosthesis implantation induces changes in bone stress that depend on the extent of porous coating
    • Skinner HB, Kim AS, Keyak JH, Mote CD: Femoral prosthesis implantation induces changes in bone stress that depend on the extent of porous coating. J Orthop Res 12:553, 1994
    • (1994) J Orthop Res , vol.12 , pp. 553
    • Skinner, H.B.1    Kim, A.S.2    Keyak, J.H.3    Mote, C.D.4
  • 10
    • 0020056442 scopus 로고
    • Stress changes in bone secondary to the use of a femoral canal plug with cemented hip replacement
    • Skinner HB, Cook SD, Weinstein AM, Haddad RJ: Stress changes in bone secondary to the use of a femoral canal plug with cemented hip replacement. Clin Orthop 166:277, 1982
    • (1982) Clin Orthop , vol.166 , pp. 277
    • Skinner, H.B.1    Cook, S.D.2    Weinstein, A.M.3    Haddad, R.J.4
  • 12
    • 0019545612 scopus 로고
    • The quasistatic and fatigue performance of the implant/bone-cement interface
    • Raab S, Ahmed AM, Provan JW: The quasistatic and fatigue performance of the implant/bone-cement interface. J Biomed Mater Res 15:159, 1981
    • (1981) J Biomed Mater Res , vol.15 , pp. 159
    • Raab, S.1    Ahmed, A.M.2    Provan, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.