메뉴 건너뛰기




Volumn 11, Issue 1, 2004, Pages 55-59

Magnetic resonance imaging of the metal clip in a breast: Safely andlts availability as a negative marker

Author keywords

Breast biopsy; Breast neoplasm; Diagnosis; Magnetic resonance

Indexed keywords

ARTICLE; BREAST TUMOR; CALCINOSIS; FEMALE; HUMAN; IMAGE QUALITY; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; SURGICAL INSTRUMENT; TREATMENT OUTCOME;

EID: 1542379871     PISSN: 13406868     EISSN: 18804233     Source Type: Journal    
DOI: 10.1007/BF02968003     Document Type: Article
Times cited : (15)

References (15)
  • 1
    • 0030840692 scopus 로고    scopus 로고
    • Comparison of the relative incidence of impalpable invasive breast carcinoma and ductal carcinoma in situ in cancers detected in patients older and younger than 50 years of age
    • Evans WP 3rd, Start AL, Bennos ES: Comparison of the relative incidence of impalpable invasive breast carcinoma and ductal carcinoma in situ in cancers detected in patients older and younger than 50 years of age. Radiology 204:489-491, 1997. (Pubitemid 27337500)
    • (1997) Radiology , vol.204 , Issue.2 , pp. 489-491
    • Evans III, W.P.1    Starr, A.L.2    Bennos, E.S.3
  • 2
    • 0025210597 scopus 로고
    • Medical audit of a rapid-throughput mammography screening practice: Methodology and results of 27,114 examinations
    • Sickles EA, Ominsky SH, Sollitto RA, Galvin HB, Monticciolo DL: Medical audit of a rapid-throughput mammography screening practice: methodology and results of 27,114 examinations. Radiology 175:323-327, 1990. (Pubitemid 20135259)
    • (1990) Radiology , vol.175 , Issue.2 , pp. 323-327
    • Sickles, E.A.1    Ominsky, S.H.2    Sollitto, R.A.3    Galvin, H.B.4    Monticciolo, D.L.5
  • 3
    • 0031229656 scopus 로고    scopus 로고
    • From the RSNA Refresher Courses: Performing a Breast Biopsy with a Directional, Vacuum-assisted Biopsy Instrument
    • Parker SH, Klaus AJ: Performing a breast biopsy with a directional, vacuum-assisted biopsy instrument. Radiolograhpics 17:1233-1252, 1997. (Pubitemid 127465191)
    • (1997) Radiographics , vol.17 , Issue.5 , pp. 1233-1252
    • Parker, S.H.1    Klaus, A.J.2
  • 4
    • 0029938332 scopus 로고    scopus 로고
    • A practical approach to minimally invasive breast biopsy
    • Parker SH, Burbank F: State of the art. A practical approach to minimally invasive breast biopsy. Radiology 200:11-20, 1996. (Pubitemid 26197334)
    • (1996) Radiology , vol.200 , Issue.1 , pp. 11-20
    • Parker, S.H.1    Burbank, F.2
  • 6
    • 0024580929 scopus 로고
    • Mr imaging of the breast: Fast imaging sequences with and without Gd-DTPA. Preliminary observations
    • Kaiser WA, Zeitler E: MR imaging of the breast: fast imaging sequences with and without Gd-DTPA. Preliminary observations. Radiology 170:681-686, 1989. (Pubitemid 19062582)
    • (1989) Radiology , vol.170 , Issue.I3 , pp. 681-686
    • Kaiser, W.A.1    Zeitler, E.2
  • 9
    • 0032958860 scopus 로고    scopus 로고
    • Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions?
    • Kuhl CK, Mielcareck P, Klaschik S, Leutner C, Wardelmann E, Gieseke J, Schild HH: Dynamic breast MR imaging: are signal intensity time course data useful for differential diagnosis of enhancing lesions? Radiology 211:5-7, 1999.
    • (1999) Radiology , vol.211 , pp. 5-7
    • Kuhl, C.K.1    Mielcareck, P.2    Klaschik, S.3    Leutner, C.4    Wardelmann, E.5    Gieseke, J.6    Schild, H.H.7
  • 10
    • 0030723987 scopus 로고    scopus 로고
    • Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization
    • Burbank F, Forcier N: Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, longterm stability, and usefulness as a guide for wire localization. Radiology 205:407-415, 1997. (Pubitemid 27467318)
    • (1997) Radiology , vol.205 , Issue.2 , pp. 407-415
    • Burbank, F.1    Forcier, N.2
  • 12
    • 0031602920 scopus 로고    scopus 로고
    • Aneurysm clip MR artifacts: Titanium versus stainless steel and influence of imaging parameters
    • Burtscher IM, Owman T, Romner B, Stahlberg F, Holtas S: Aneurysm clip MR artifacts. Titanium versus stainless steel and influence of imaging parameters. Acta Radio139:70-76, 1998. (Pubitemid 128459364)
    • (1998) Acta Radiologica , vol.39 , Issue.1 , pp. 70-76
    • Burtscher, I.M.1    Owman, T.2    Romner, B.3    Stahlberg, F.4    Holtas, S.5
  • 14
    • 0035164002 scopus 로고    scopus 로고
    • Metallic surgical instruments for interventional MRI procedures: Evaluation of MR safety
    • DOI 10.1002/1522-2586(200101)13:1<152::AID-JMRI1023>3.0.CO;2-C
    • Shellock FG: Metallic surgical instruments for interventional MR/procedures: evaluation of MR safety. J Magn Reson Imaging 13:152-157, 2001. (Pubitemid 32044574)
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , Issue.1 , pp. 152-157
    • Shellock, F.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.