메뉴 건너뛰기




Volumn 17, Issue 3-6, 2004, Pages 281-287

Measurements of T1 and T2 relaxation times of colon cancer metastases in rat liver at 7 T

Author keywords

Colon cancer; High field MR; Liver metastasis; Rat; T1 and T 2 relaxation times

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BREATHING; COLON CARCINOMA; CONTROLLED STUDY; IMAGING; LIVER METASTASIS; LIVER STRUCTURE; MALE; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RAT; SIGNAL NOISE RATIO; TUMOR GROWTH; ANIMAL; CARCINOMA; COLON TUMOR; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; DISEASE MODEL; EVALUATION; IMAGE ENHANCEMENT; LIVER TUMOR; METASTASIS; METHODOLOGY; PATHOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TUMOR CELL LINE; VALIDATION STUDY;

EID: 14944382747     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-004-0068-2     Document Type: Article
Times cited : (34)

References (26)
  • 1
    • 0036230263 scopus 로고    scopus 로고
    • Treatment of liver metastases, an update on the possibilities and results
    • Ruers T, Bleichrodt RP (2002) Treatment of liver metastases, an update on the possibilities and results. Eur J Cancer 38(7):1023-1033
    • (2002) Eur J Cancer , vol.38 , Issue.7 , pp. 1023-1033
    • Ruers, T.1    Bleichrodt, R.P.2
  • 2
    • 0034066194 scopus 로고    scopus 로고
    • Imaging liver metastases: Current limitations and future prospects
    • Robinson PJ (2000) Imaging liver metastases: current limitations and future prospects. Br J Radiol 73(867):234-241
    • (2000) Br J Radiol , vol.73 , Issue.867 , pp. 234-241
    • Robinson, P.J.1
  • 3
    • 0032956637 scopus 로고    scopus 로고
    • Hepatic lesion detection: Comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis
    • Ward J, Naik KS, Guthrie JA, Wilson D, Robinson PJ (1999) Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis. Radiology 210(2):459-466
    • (1999) Radiology , vol.210 , Issue.2 , pp. 459-466
    • Ward, J.1    Naik, K.S.2    Guthrie, J.A.3    Wilson, D.4    Robinson, P.J.5
  • 4
    • 0029808352 scopus 로고    scopus 로고
    • Detection of hepatic metastases: Ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography
    • Seneterre E, Taourel P, Bouvier Y, Pradel J, Van Beers B, Daures JP, Pringot J, Mathieu D, Bruel JM (1996) Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography. Radiology 200(3):785-792
    • (1996) Radiology , vol.200 , Issue.3 , pp. 785-792
    • Seneterre, E.1    Taourel, P.2    Bouvier, Y.3    Pradel, J.4    Van Beers, B.5    Daures, J.P.6    Pringot, J.7    Mathieu, D.8    Bruel, J.M.9
  • 5
    • 1942501552 scopus 로고    scopus 로고
    • Does hypervascularity of liver metastases as detected on MRI predict disease progression in breast cancer patients?
    • Braga L, Semelka RC, Pietrobon R, Martin D, de Barros N, Guller U (2004) Does hypervascularity of liver metastases as detected on MRI predict disease progression in breast cancer patients? AJR Am J Roentgenol 182(5):1207-1213
    • (2004) AJR Am J Roentgenol , vol.182 , Issue.5 , pp. 1207-1213
    • Braga, L.1    Semelka, R.C.2    Pietrobon, R.3    Martin, D.4    De Barros, N.5    Guller, U.6
  • 7
    • 0026771283 scopus 로고
    • Quantitative study of the growth of experimental hepatic tumors in rats by using magnetic resonance imaging
    • Qin Y, Van Cauteren M, Osteaux M, Willems G (1992) Quantitative study of the growth of experimental hepatic tumors in rats by using magnetic resonance imaging. Int J Cancer 51(4):665-670
    • (1992) Int J Cancer , vol.51 , Issue.4 , pp. 665-670
    • Qin, Y.1    Van Cauteren, M.2    Osteaux, M.3    Willems, G.4
  • 8
    • 0026463831 scopus 로고
    • Inhibitory effect of somatostatin analogue RC-160 on the growth of hepatic metastases of colon cancer in rats: A study with magnetic resonance imaging
    • Qin Y, Van Cauteren M, Osteaux M, Schally AV, Willems G (1992) Inhibitory effect of somatostatin analogue RC-160 on the growth of hepatic metastases of colon cancer in rats: a study with magnetic resonance imaging. Cancer Res 52(21):6025-6030
    • (1992) Cancer Res , vol.52 , Issue.21 , pp. 6025-6030
    • Qin, Y.1    Van Cauteren, M.2    Osteaux, M.3    Schally, A.V.4    Willems, G.5
  • 12
    • 0034845550 scopus 로고    scopus 로고
    • Microstrip RF surface coil design for extremely high-field MRI and spectroscopy
    • Zhang X, Ugurbil K, Chen W (2001) Microstrip RF surface coil design for extremely high-field MRI and spectroscopy. Magn Reson Med 46(3):443-450
    • (2001) Magn Reson Med , vol.46 , Issue.3 , pp. 443-450
    • Zhang, X.1    Ugurbil, K.2    Chen, W.3
  • 15
    • 0032967741 scopus 로고    scopus 로고
    • Enhanced tumor detection in the presence of liver cirrhosis: Experimental study on the diagnostic value of a superparamagnetic iron oxide MR imaging contrast agent (NSR 0430)
    • Bachmann R, Kreft B, Dombrowski F, Block W, Oksendal A, Schild H (1999) Enhanced tumor detection in the presence of liver cirrhosis: experimental study on the diagnostic value of a superparamagnetic iron oxide MR imaging contrast agent (NSR 0430). J Magn Reson Imaging 9(2):251-256
    • (1999) J Magn Reson Imaging , vol.9 , Issue.2 , pp. 251-256
    • Bachmann, R.1    Kreft, B.2    Dombrowski, F.3    Block, W.4    Oksendal, A.5    Schild, H.6
  • 16
    • 0037964274 scopus 로고    scopus 로고
    • Comparison between signal-to-noise ratio, liver-to-muscle ratio, and 1/T2 for the noninvasive assessment of liver iron content by MRI
    • Fenzi A, Bortolazzi M, Marzola P (2003) Comparison between signal-to-noise ratio, liver-to-muscle ratio, and 1/T2 for the noninvasive assessment of liver iron content by MRI. J Magn Reson Imaging 17(5):589-592
    • (2003) J Magn Reson Imaging , vol.17 , Issue.5 , pp. 589-592
    • Fenzi, A.1    Bortolazzi, M.2    Marzola, P.3
  • 18
    • 0001480742 scopus 로고
    • Quantification of T1 values by snapshot-FLASH NMR imaging
    • Deichmann R, Haase A (1992) Quantification of T1 values by snapshot-FLASH NMR imaging. J Magn Reson 96:608-612
    • (1992) J Magn Reson , vol.96 , pp. 608-612
    • Deichmann, R.1    Haase, A.2
  • 19
    • 0034741677 scopus 로고    scopus 로고
    • Osmotic effects on the T2 relaxation decay of in vivo muscle
    • Gambarota G, Cairns BE, Berde CB, Mulkern RV (2001) Osmotic effects on the T2 relaxation decay of in vivo muscle. Magn Reson Med 46(3):592-599
    • (2001) Magn Reson Med , vol.46 , Issue.3 , pp. 592-599
    • Gambarota, G.1    Cairns, B.E.2    Berde, C.B.3    Mulkern, R.V.4
  • 20
    • 0030753231 scopus 로고    scopus 로고
    • Monitoring early response of experimental brain tumors to therapy using diffusion magnetic resonance imaging
    • Chenevert TL, McKeever PE, Ross BD (1997) Monitoring early response of experimental brain tumors to therapy using diffusion magnetic resonance imaging. Clin Cancer Res 3(9):1457-1466
    • (1997) Clin Cancer Res , vol.3 , Issue.9 , pp. 1457-1466
    • Chenevert, T.L.1    McKeever, P.E.2    Ross, B.D.3
  • 21
  • 22
    • 0037675000 scopus 로고    scopus 로고
    • In situ localization of gelatinolytic activity in the extracellular matrix of metastases of colon cancer in rat liver using quenched fluorogenic DQ-gelatin
    • Mook OR, Van Overbeek C, Ackema EG, Van Maldegem F, Frederiks WM (2003) In situ localization of gelatinolytic activity in the extracellular matrix of metastases of colon cancer in rat liver using quenched fluorogenic DQ-gelatin. J Histochem Cytochem 51(6):821-829
    • (2003) J Histochem Cytochem , vol.51 , Issue.6 , pp. 821-829
    • Mook, O.R.1    Van Overbeek, C.2    Ackema, E.G.3    Van Maldegem, F.4    Frederiks, W.M.5
  • 23
    • 0035105931 scopus 로고    scopus 로고
    • In vivo investigation of hepatic iron overload in rats using T2 maps: Quantification at high intensity field (4.7-T)
    • Fenzi A, Bortolazzi M, Marzola P, Colombari R (2001) In vivo investigation of hepatic iron overload in rats using T2 maps: quantification at high intensity field (4.7-T). J Magn Reson Imaging 13(3):392-396
    • (2001) J Magn Reson Imaging , vol.13 , Issue.3 , pp. 392-396
    • Fenzi, A.1    Bortolazzi, M.2    Marzola, P.3    Colombari, R.4
  • 25
    • 0028136916 scopus 로고
    • Liver iron quantification: Studies in aqueous iron solutions, iron overloaded rats, and patients with hereditary hemochromatosis
    • Engelhardt R, Langkowski JH, Fischer R, Nielsen P, Kooijman H, Heinrich HC, Bucheler E (1994) Liver iron quantification: studies in aqueous iron solutions, iron overloaded rats, and patients with hereditary hemochromatosis. Magn Reson Imaging 12(7):999-1007
    • (1994) Magn Reson Imaging , vol.12 , Issue.7 , pp. 999-1007
    • Engelhardt, R.1    Langkowski, J.H.2    Fischer, R.3    Nielsen, P.4    Kooijman, H.5    Heinrich, H.C.6    Bucheler, E.7
  • 26
    • 0033093619 scopus 로고    scopus 로고
    • MR imaging of hepatic injury in the LEC rat under a high magnetic field (7.05 T)
    • Asanuma T, Hirano Y, Yamamoto K, Kon Y, Shimokawa S, Kuwabara M (1999) MR imaging of hepatic injury in the LEC rat under a high magnetic field (7.05 T). J Vet Med Sci 61(3):239-244
    • (1999) J Vet Med Sci , vol.61 , Issue.3 , pp. 239-244
    • Asanuma, T.1    Hirano, Y.2    Yamamoto, K.3    Kon, Y.4    Shimokawa, S.5    Kuwabara, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.