메뉴 건너뛰기




Volumn 30, Issue 11, 2003, Pages 1574-1597

From PET detectors to PET scanners

Author keywords

BGO; Depth of interaction; LSO; PET detectors; Positron emission tomography

Indexed keywords

BISMUTH DERIVATIVE; BISMUTH GERMANATE; GERMANIUM DERIVATIVE; GERMANIUM OXYORTHOSILICATE; LUTETIUM; LUTETIUM OXYORTHOSILICATE; RADIOISOTOPE; SILICIC ACID; SODIUM IODIDE; THALLIUM; UNCLASSIFIED DRUG;

EID: 0242323719     PISSN: 16197070     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-003-1266-2     Document Type: Review
Times cited : (199)

References (102)
  • 1
    • 0016631386 scopus 로고
    • Application of annihilation coincidence detection to transaxial reconstruction tomography
    • Phelps ME, Hoffman EJ, Mullani NA, Ter-Pogossian MM. Application of annihilation coincidence detection to transaxial reconstruction tomography. J Nucl Med 1975; 16:210-224.
    • (1975) J Nucl Med , vol.16 , pp. 210-224
    • Phelps, M.E.1    Hoffman, E.J.2    Mullani, N.A.3    Ter-Pogossian, M.M.4
  • 6
    • 0242354344 scopus 로고
    • Chicago: The University of Chicago Press
    • Fermi E. Nuclearphysics. Chicago: The University of Chicago Press, 1949.
    • (1949) Nuclearphysics
    • Fermi, E.1
  • 9
    • 0000827496 scopus 로고
    • The angular correction of scattered annihilation radiation
    • Wu CS, Shaknov I. The angular correction of scattered annihilation radiation. Phys Rev 1950; 77:136.
    • (1950) Phys Rev , vol.77 , pp. 136
    • Wu, C.S.1    Shaknov, I.2
  • 11
    • 0001835009 scopus 로고
    • Localitation of brain tumours with positron emitters
    • Brownell GL, Sweet WH. Localitation of brain tumours with positron emitters. Nucleonics 1953; 11:40-45.
    • (1953) Nucleonics , vol.11 , pp. 40-45
    • Brownell, G.L.1    Sweet, W.H.2
  • 12
    • 51249195171 scopus 로고
    • Study of positronium in water and ice from 22 to -144°C by annihilation quanta measurements
    • Colombino P, Fiscella B, Trossi L. Study of positronium in water and ice from 22 to -144°C by annihilation quanta measurements. Il Nuovo Cimento 1965; xxxviii(2):707-723.
    • (1965) Il Nuovo Cimento , vol.38 , Issue.2 , pp. 707-723
    • Colombino, P.1    Fiscella, B.2    Trossi, L.3
  • 13
    • 0242322972 scopus 로고
    • Experimental studies of positron interactions in solids and liquids
    • Berko S, Hereford FL. Experimental studies of positron interactions in solids and liquids. Rev Modern Phys 1956; 28:299-307.
    • (1956) Rev Modern Phys , vol.28 , pp. 299-307
    • Berko, S.1    Hereford, F.L.2
  • 14
    • 0033635125 scopus 로고    scopus 로고
    • Comparative evaluation of scatter correction techniques in 3D positron emission tomography
    • Zaidi H. Comparative evaluation of scatter correction techniques in 3D positron emission tomography. Eur J Nucl Med 2000; 27:1813-1826.
    • (2000) Eur J Nucl Med , vol.27 , pp. 1813-1826
    • Zaidi, H.1
  • 15
    • 0034092414 scopus 로고    scopus 로고
    • Scintillation crystals for PET
    • Melcher CL. Scintillation crystals for PET. J Nucl Med 2000; 41:1051-1055.
    • (2000) J Nucl Med , vol.41 , pp. 1051-1055
    • Melcher, C.L.1
  • 18
    • 0035724143 scopus 로고    scopus 로고
    • Timing properties of LuAP:Ce studies with large area avalanche photodiodes
    • Balcerzyk M, Moszynski M, Kapusta M, Szawlowski M. Timing properties of LuAP:Ce studies with large area avalanche photodiodes. IEEE Trans Nucl Sci 2001; NS-48:2344-2347.
    • (2001) IEEE Trans Nucl Sci , vol.NS-48 , pp. 2344-2347
    • Balcerzyk, M.1    Moszynski, M.2    Kapusta, M.3    Szawlowski, M.4
  • 22
    • 0035659148 scopus 로고    scopus 로고
    • Performance of a whole-body PET scanner using curve-plate NaI(T1) detectors
    • Adam LE, Karp JS, Daube-Witherspoon ME, Smith RJ. Performance of a whole-body PET scanner using curve-plate NaI(T1) detectors. J Nucl Med 2001; 42:1821-1830.
    • (2001) J Nucl Med , vol.42 , pp. 1821-1830
    • Adam, L.E.1    Karp, J.S.2    Daube-Witherspoon, M.E.3    Smith, R.J.4
  • 28
    • 0026902676 scopus 로고
    • Cerium-doped lutetium oxyorthosilicate: A fast and efficient new scintillator
    • Melcher CL, Schweitzer JS. Cerium-doped lutetium oxyorthosilicate: a fast and efficient new scintillator. IEEE Trans Nucl Sci 1992; NS-39:502-505.
    • (1992) IEEE Trans Nucl Sci , vol.NS-39 , pp. 502-505
    • Melcher, C.L.1    Schweitzer, J.S.2
  • 32
    • 85039624274 scopus 로고    scopus 로고
    • An exhaustive and systematic search for optimal PET scintillator materials
    • Presented at IEEE NSS and MIC Conference 2001, Conference Record, N12-69
    • Shlichta PJ. An exhaustive and systematic search for optimal PET scintillator materials. Presented at IEEE NSS and MIC Conference 2001, Conference Record, N12-69. IEEE Trans Nucl Sci 2002; NS-49.
    • (2002) IEEE Trans Nucl Sci , vol.NS-49
    • Shlichta, P.J.1
  • 33
    • 0000301040 scopus 로고    scopus 로고
    • Prospects of first-principle calculations of scintillator properties
    • DeRenzo SE, Weber MJ. Prospects of first-principle calculations of scintillator properties. Nucl Instrum Meth 1999; A422:111-118.
    • (1999) Nucl Instrum Meth , vol.A422 , pp. 111-118
    • DeRenzo, S.E.1    Weber, M.J.2
  • 34
    • 0036702966 scopus 로고    scopus 로고
    • New inorganic scintillation materials development for medical imaging
    • Lecoq P, Korzhik M. New inorganic scintillation materials development for medical imaging. IEEE Trans Nucl Sci 2002; 49:1651-1654.
    • (2002) IEEE Trans Nucl Sci , vol.49 , pp. 1651-1654
    • Lecoq, P.1    Korzhik, M.2
  • 35
    • 0037149996 scopus 로고    scopus 로고
    • Inorganic scintillators in medical imaging
    • Van Eijk CWE. Inorganic scintillators in medical imaging. Phys Med Biol 2002; 47:R85-R106.
    • (2002) Phys Med Biol , vol.47
    • Van Eijk, C.W.E.1
  • 36
  • 39
    • 48549113488 scopus 로고
    • Semiconductor drift chamber on application of novel charge transport scheme
    • Gatti E, Rehak P. Semiconductor drift chamber on application of novel charge transport scheme. Nucl Instrum Meth 1984; A225:608-614.
    • (1984) Nucl Instrum Meth , vol.A225 , pp. 608-614
    • Gatti, E.1    Rehak, P.2
  • 40
    • 0242277989 scopus 로고
    • Semiconductor radiation detectors
    • Lutz G. Semiconductor radiation detectors. Nucl Instrum Meth 1995; A367:21-33.
    • (1995) Nucl Instrum Meth , vol.A367 , pp. 21-33
    • Lutz, G.1
  • 41
    • 0242309740 scopus 로고
    • Some simple considerations on pulse shapes in radiation detectors
    • Delaney CFG, Finch EC. Some simple considerations on pulse shapes in radiation detectors. Am J Phys 1984; 52:351-354.
    • (1984) Am J Phys , vol.52 , pp. 351-354
    • Delaney, C.F.G.1    Finch, E.C.2
  • 42
    • 0001129520 scopus 로고
    • Low noise techniques in detectors
    • Radeka V. Low noise techniques in detectors. Phys Rev Nucl Part Sci 1988; 38:217-277.
    • (1988) Phys Rev Nucl Part Sci , vol.38 , pp. 217-277
    • Radeka, V.1
  • 43
    • 0021303635 scopus 로고
    • Silicon photon diode detection of bismuth-germanate scintillator light
    • Groom DE. Silicon photon diode detection of bismuth-germanate scintillator light. Nucl Instrum Meth 1984; A219:141-148.
    • (1984) Nucl Instrum Meth , vol.A219 , pp. 141-148
    • Groom, D.E.1
  • 44
    • 0001323203 scopus 로고    scopus 로고
    • Development of low noise, back-side illuminated silicon photodiode array
    • Holland SE, et al. Development of low noise, back-side illuminated silicon photodiode array. IEEE Trans Nucl Sci 1997; NS-44:443-447.
    • (1997) IEEE Trans Nucl Sci , vol.NS-44 , pp. 443-447
    • Holland, S.E.1
  • 45
    • 0036464444 scopus 로고    scopus 로고
    • A compact 64 pixel Cs(T1)/Si PIN photodiode imaging module with IC readout
    • Gruber GI, et al. A compact 64 pixel Cs(T1)/Si PIN photodiode imaging module with IC readout. IEEE Trans Nucl Sci 2002; NS-49:147-152.
    • (2002) IEEE Trans Nucl Sci , vol.NS-49 , pp. 147-152
    • Gruber, G.I.1
  • 46
    • 0000103809 scopus 로고    scopus 로고
    • Investigation of a new readout scheme for high resolution scintillation crystals arrays using photodiodes
    • Levin CS, Hoffman EJ. Investigation of a new readout scheme for high resolution scintillation crystals arrays using photodiodes. IEEE Trans Nucl Sci 1997; NS-44:1208.
    • (1997) IEEE Trans Nucl Sci , vol.NS-44 , pp. 1208
    • Levin, C.S.1    Hoffman, E.J.2
  • 47
    • 0029357391 scopus 로고
    • Gamma ray spectroscopy and timing using LSO and PIN photodiodes
    • Moses WW, Derenzo SE. Gamma ray spectroscopy and timing using LSO and PIN photodiodes. IEEE Trans Nucl Sci 1995; NS-42:597.
    • (1995) IEEE Trans Nucl Sci , vol.NS-42 , pp. 597
    • Moses, W.W.1    Derenzo, S.E.2
  • 50
    • 0028493624 scopus 로고
    • Design and engineering aspects of a high resolution positron for small animal imaging
    • Lecomte R, Cadorette J, Richard P, Rodrigue S, Rouleau D. Design and engineering aspects of a high resolution positron for small animal imaging. IEEE Trans Nucl Sci 1994; 41:1446-1452.
    • (1994) IEEE Trans Nucl Sci , vol.41 , pp. 1446-1452
    • Lecomte, R.1    Cadorette, J.2    Richard, P.3    Rodrigue, S.4    Rouleau, D.5
  • 54
    • 0027644024 scopus 로고
    • Performance of PET detector module utilizing an array of silicon photodiodes to identify the crystal of interaction
    • Moses WW, Derenzo SE, Nutt R, Digby WM, Williams CW, Andreaco M. Performance of PET detector module utilizing an array of silicon photodiodes to identify the crystal of interaction. IEEE Trans Nucl Sci 1993; 40:1036-1040.
    • (1993) IEEE Trans Nucl Sci , vol.40 , pp. 1036-1040
    • Moses, W.W.1    Derenzo, S.E.2    Nutt, R.3    Digby, W.M.4    Williams, C.W.5    Andreaco, M.6
  • 55
    • 0028494319 scopus 로고
    • Design studies for a PET detector module using a PIN photodiodes to measure depth of interaction
    • Moses WW, Derenzo SE. Design studies for a PET detector module using a PIN photodiodes to measure depth of interaction. IEEE Trans Nucl Sci 1994; 41:1441-1445.
    • (1994) IEEE Trans Nucl Sci , vol.41 , pp. 1441-1445
    • Moses, W.W.1    Derenzo, S.E.2
  • 56
    • 0032098875 scopus 로고    scopus 로고
    • Calibration of PET detector module that measure depth of interaction
    • Huber JS, Moses WW, Virador PRG. Calibration of PET detector module that measure depth of interaction. IEEE Trans Nucl Sci 1998; 45:1268-1272.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 1268-1272
    • Huber, J.S.1    Moses, W.W.2    Virador, P.R.G.3
  • 57
    • 0035355180 scopus 로고    scopus 로고
    • An LSO scintillator array for a PET detector module with depth of interaction measurements
    • Huber JS, Moses WW, Andreaco MS, Petterson O. An LSO scintillator array for a PET detector module with depth of interaction measurements. IEEE Trans Nucl Sci 2001; 48:684-688.
    • (2001) IEEE Trans Nucl Sci , vol.48 , pp. 684-688
    • Huber, J.S.1    Moses, W.W.2    Andreaco, M.S.3    Petterson, O.4
  • 59
    • 0031170702 scopus 로고    scopus 로고
    • Construction and calibration of detectors for high resolution metabolic breast cancer imaging
    • Robar JL, Thompson CJ, Murthy K, Clancy R, Bergman AM. Construction and calibration of detectors for high resolution metabolic breast cancer imaging. Nucl Instrum Meth 1997; 392:402-406.
    • (1997) Nucl Instrum Meth , vol.392 , pp. 402-406
    • Robar, J.L.1    Thompson, C.J.2    Murthy, K.3    Clancy, R.4    Bergman, A.M.5
  • 62
    • 0242309742 scopus 로고    scopus 로고
    • A study of depth of interaction measurements using bent optical fibers
    • Shao Y, Cherry SR. A study of depth of interaction measurements using bent optical fibers. J Nucl Med 1998; 39:191 Suppl S.
    • (1998) J Nucl Med , vol.39 , Issue.SUPPL. S , pp. 191
    • Shao, Y.1    Cherry, S.R.2
  • 63
    • 0032100082 scopus 로고    scopus 로고
    • A GSO depth of interaction detector for PET
    • Yamamoto S, Ishibashi I, "A GSO depth of interaction detector for PET. IEEE Trans Nucl Sci 1998; 45:1078-1082.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 1078-1082
    • Yamamoto, S.1    Ishibashi, I.2
  • 64
    • 0033321161 scopus 로고    scopus 로고
    • Advantages using pulse shape discrimination to assign the depth of interaction information (DOI) from a multi layer phoswich detector
    • Schmand M, Eriksson L, Casey ME, Wienhard K, Flugge G, Nutt R. Advantages using pulse shape discrimination to assign the depth of interaction information (DOI) from a multi layer phoswich detector. IEEE Trans Nucl Sci 1999; 46:985-990.
    • (1999) IEEE Trans Nucl Sci , vol.46 , pp. 985-990
    • Schmand, M.1    Eriksson, L.2    Casey, M.E.3    Wienhard, K.4    Flugge, G.5    Nutt, R.6
  • 67
    • 0032142529 scopus 로고    scopus 로고
    • Depth of interaction for PET using segmented crystals
    • MacDonald LR, Dahlbohm M. Depth of interaction for PET using segmented crystals. IEEE Trans Nucl Sci 1998; 45:2144-2148.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 2144-2148
    • MacDonald, L.R.1    Dahlbohm, M.2
  • 69
    • 0036464484 scopus 로고    scopus 로고
    • Spatial resolution and depth of interaction studies with a PET detector module composed of LSO and an APD array
    • Fremout AAR, Chen RR, Bruyndonckx P, Tavernier SPK. Spatial resolution and depth of interaction studies with a PET detector module composed of LSO and an APD array. IEEE Trans Nucl Sci 2002; 49:131-138.
    • (2002) IEEE Trans Nucl Sci , vol.49 , pp. 131-138
    • Fremout, A.A.R.1    Chen, R.R.2    Bruyndonckx, P.3    Tavernier, S.P.K.4
  • 70
    • 0036815754 scopus 로고    scopus 로고
    • Design of a high resolution and high sensitivity scintillation crystal array with nearly perfect light collection
    • Levin CS. Design of a high resolution and high sensitivity scintillation crystal array with nearly perfect light collection. IEEE Trans Nucl Sci 2002; 49:2236-2243.
    • (2002) IEEE Trans Nucl Sci , vol.49 , pp. 2236-2243
    • Levin, C.S.1
  • 71
    • 0036203522 scopus 로고    scopus 로고
    • The history of positron emission tomography
    • Nutt R. The history of positron emission tomography. Mol Imag Biol 2002; 4:11-26.
    • (2002) Mol Imag Biol , vol.4 , pp. 11-26
    • Nutt, R.1
  • 78
    • 0142126690 scopus 로고    scopus 로고
    • Time of flight in PET revisited
    • in press
    • Moses WW. Time of flight in PET revisited. IEEE Trans Nucl Sci 2003: in press.
    • (2003) IEEE Trans Nucl Sci
    • Moses, W.W.1
  • 79
    • 0003710941 scopus 로고    scopus 로고
    • NEMA Standard Publication NU 2-1994. Washington: National Electrical Manufacturers Association
    • NEMA Standard Publication NU 2-1994. Performance measurements of positron emission tomographs. Washington: National Electrical Manufacturers Association, 1994.
    • (1994) Performance Measurements of Positron Emission Tomographs
  • 80
    • 0003710941 scopus 로고    scopus 로고
    • NEMA Standard Publication NU 2-2001Rosslyn, VA: National Electrical Manufacturers Association
    • NEMA Standard Publication NU 2-2001. Performance measurements of positron emission tomographs. Rosslyn, VA: National Electrical Manufacturers Association, 2001.
    • (2001) Performance Measurements of Positron Emission Tomographs
  • 84
    • 0036840060 scopus 로고    scopus 로고
    • Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis
    • Kadrmas DJ, Christian PE. Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis. J Nucl Med 2002; 43:1545-1554.
    • (2002) J Nucl Med , vol.43 , pp. 1545-1554
    • Kadrmas, D.J.1    Christian, P.E.2
  • 85
    • 0028945864 scopus 로고
    • A miracle enough: The power of mice
    • Paigen K. A miracle enough: the power of mice. Nature Med 1995; 1:215-220.
    • (1995) Nature Med , vol.1 , pp. 215-220
    • Paigen, K.1
  • 86
    • 0030025774 scopus 로고    scopus 로고
    • Genes and physiology: Molecular physiology in genetically engineered animals
    • Chien KR. Genes and physiology: molecular physiology in genetically engineered animals. J Clin Investig 1996; 97:901-909.
    • (1996) J Clin Investig , vol.97 , pp. 901-909
    • Chien, K.R.1
  • 87
    • 0034126959 scopus 로고    scopus 로고
    • PET: The merging of biology and imaging into molecular imaging
    • Phelps ME. PET: The merging of biology and imaging into molecular imaging. J Nucl Med 2000; 41:661-681.
    • (2000) J Nucl Med , vol.41 , pp. 661-681
    • Phelps, M.E.1
  • 88
    • 0026522954 scopus 로고
    • Design features performance of a PET system for animal research
    • Cutler PD, Cherry SR, Hoffman EJ. Design features performance of a PET system for animal research. J Nucl Med 1992; 33:595-604.
    • (1992) J Nucl Med , vol.33 , pp. 595-604
    • Cutler, P.D.1    Cherry, S.R.2    Hoffman, E.J.3
  • 89
    • 0028486732 scopus 로고
    • Are animal scanners really necessary for PET?
    • Hichwa R. Are animal scanners really necessary for PET? J Nucl Med 1994; 35:1396-1397.
    • (1994) J Nucl Med , vol.35 , pp. 1396-1397
    • Hichwa, R.1
  • 90
    • 0036071403 scopus 로고    scopus 로고
    • Advances in animal PET scanners
    • Del Guerra A, Belcari N. Advances in animal PET scanners. Q J Nucl Med 2002; 46:35-47.
    • (2002) Q J Nucl Med , vol.46 , pp. 35-47
    • Del Guerra, A.1    Belcari, N.2
  • 92
    • 0034753191 scopus 로고    scopus 로고
    • Detector development for microPET II: A 1 microl resolution PET scanner for small animal imaging
    • Chatziioannou A, Tai YC, Doshi N, Cherry SR. Detector development for microPET II: a 1 microl resolution PET scanner for small animal imaging. Phys Med Biol 2001; 46:2899-2910.
    • (2001) Phys Med Biol , vol.46 , pp. 2899-2910
    • Chatziioannou, A.1    Tai, Y.C.2    Doshi, N.3    Cherry, S.R.4
  • 93
    • 0032316712 scopus 로고    scopus 로고
    • YAP-PET: First results of a small animal positron emission tomograph based on YAP: Ce finger crystals
    • Del Guerra A, Di Domenico G, Scandola M, Zavattini G. YAP-PET: first results of a small animal positron emission tomograph based on YAP: Ce finger crystals. IEEE Trans Nucl Sci 1998; 45:3105-3108.
    • (1998) IEEE Trans Nucl Sci , vol.45 , pp. 3105-3108
    • Del Guerra, A.1    Di Domenico, G.2    Scandola, M.3    Zavattini, G.4
  • 97
    • 0035476809 scopus 로고    scopus 로고
    • Complementary emerging techniques: High-resolution PET and MRI
    • Jakobs RE, Cherry SR. Complementary emerging techniques: high-resolution PET and MRI. Curr Opin Neurobiol 2001; 11:621-629.
    • (2001) Curr Opin Neurobiol , vol.11 , pp. 621-629
    • Jakobs, R.E.1    Cherry, S.R.2
  • 98
    • 0037457856 scopus 로고    scopus 로고
    • Fundamental limits of positron emission mammography
    • Moses WW, Qi J. Fundamental limits of positron emission mammography. Nucl Instrum Meth 2003; A497A:82-89.
    • (2003) Nucl Instrum Meth , vol.A497A , pp. 82-89
    • Moses, W.W.1    Qi, J.2
  • 99
    • 0029359890 scopus 로고
    • Positron emission mammography (PEM): A promising technique for detecting breast cancer
    • Thompson CJ, Murthy K, Weinberg IN, Mako R. Positron emission mammography (PEM): a promising technique for detecting breast cancer. IEEE Trans Nucl Sci 1995; 42:1012-1017.
    • (1995) IEEE Trans Nucl Sci , vol.42 , pp. 1012-1017
    • Thompson, C.J.1    Murthy, K.2    Weinberg, I.N.3    Mako, R.4
  • 100


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.