메뉴 건너뛰기




Volumn 74, Issue 3, 2005, Pages 315-322

Clinical impact of the detector size effect in 3D-CRT

Author keywords

Clinical impact; Detector size effect; Penumbra dosimetry

Indexed keywords

ALGORITHM; ARTICLE; BRAIN STEM; CANCER CONTROL; CHORDOMA; COMPUTER ASSISTED RADIOTHERAPY; DIODE; FOURIER TRANSFORMATION; HISTOGRAM; HYPOPHYSIS TUMOR; IONIZATION CHAMBER; PRIORITY JOURNAL; PROBABILITY; PROSTATE CANCER; RADIATION DETECTOR; RADIATION DOSE; RADIOBIOLOGY; RECTUM; TREATMENT PLANNING;

EID: 14844320582     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2004.10.012     Document Type: Article
Times cited : (16)

References (38)
  • 1
    • 0000974827 scopus 로고    scopus 로고
    • TG 53. Quality assurance for clinical radiotherapy treatment planning
    • American Association Of Physics in Medicine (AAPM)
    • American Association Of Physics in Medicine (AAPM) TG 53. Quality assurance for clinical radiotherapy treatment planning Med Phys 10 1998 1773 1829
    • (1998) Med Phys , vol.10 , pp. 1773-1829
  • 2
    • 0037152478 scopus 로고    scopus 로고
    • Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams
    • G. Bednarz, M. Saiful Huq, and U.F. Rosenow Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams Phys Med Biol 47 2002 3643 3649
    • (2002) Phys Med Biol , vol.47 , pp. 3643-3649
    • Bednarz, G.1    Saiful Huq, M.2    Rosenow, U.F.3
  • 3
    • 0025998401 scopus 로고
    • Fitting of normal tissue tolerance data to an analytic function
    • J.T. Burman, G.J. Kutcher, and B. Emami Fitting of normal tissue tolerance data to an analytic function Int J Rad Oncol Biol Phys 21 1991 123 135
    • (1991) Int J Rad Oncol Biol Phys , vol.21 , pp. 123-135
    • Burman, J.T.1    Kutcher, G.J.2    Emami, B.3
  • 4
    • 0029818463 scopus 로고    scopus 로고
    • The effect of detector size to the broadening of the penumbra a computer simulated study
    • K.S. Chang, F.F. Yin, and K.W. Nie The effect of detector size to the broadening of the penumbra a computer simulated study Med Phys 23 1996 1407 1411
    • (1996) Med Phys , vol.23 , pp. 1407-1411
    • Chang, K.S.1    Yin, F.F.2    Nie, K.W.3
  • 5
    • 0021227635 scopus 로고
    • Analysis of physical parameters associated with the measurement of high energy X-ray penumbra
    • D.J. Dawson, J.M. Harper, and C.A. Akinradewo Analysis of physical parameters associated with the measurement of high energy X-ray penumbra Med Phys 11 1984 491 497
    • (1984) Med Phys , vol.11 , pp. 491-497
    • Dawson, D.J.1    Harper, J.M.2    Akinradewo, C.A.3
  • 6
    • 0025939587 scopus 로고
    • Tolerance of normal tissue to therapeutic irradiation
    • B. Emami, J. Lyman, and A. Brown Tolerance of normal tissue to therapeutic irradiation Int J Radiat Oncol Biol Phys 21 1991 109 122
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 109-122
    • Emami, B.1    Lyman, J.2    Brown, A.3
  • 7
    • 0142186671 scopus 로고    scopus 로고
    • Rectal dose-volume constraints in high-dose radiotherapy of localized prostate cancer
    • C. Fiorino, G. Sanguineti, and C. Cozzarini Rectal dose-volume constraints in high-dose radiotherapy of localized prostate cancer Int J Radiat Oncol Biol Phys 57 2003 953 962
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 953-962
    • Fiorino, C.1    Sanguineti, G.2    Cozzarini, C.3
  • 8
    • 0038176478 scopus 로고    scopus 로고
    • Experimental validation tests of FFT Convolution and Multigrid Superposition algorithms for dose calculation in low-density media
    • F. García-Vicente, A. Miñambres, I. Jerez, I. Modolell, L. Pérez, and J.J. Torres Experimental validation tests of FFT Convolution and Multigrid Superposition algorithms for dose calculation in low-density media Radiot Oncol 67 2003 239 249
    • (2003) Radiot Oncol , vol.67 , pp. 239-249
    • García-Vicente, F.1    Miñambres, A.2    Jerez, I.3    Modolell, I.4    Pérez, L.5    Torres, J.J.6
  • 9
    • 17344379416 scopus 로고    scopus 로고
    • Exact analytical solution of the convolution integral equation for a general profile fitting function and gaussian detector kernel
    • F. García-Vicente, J.M. Delgado, and C. Rodriguez Exact analytical solution of the convolution integral equation for a general profile fitting function and gaussian detector kernel Phys Med Biol 45 2000 645 650
    • (2000) Phys Med Biol , vol.45 , pp. 645-650
    • García-Vicente, F.1    Delgado, J.M.2    Rodriguez, C.3
  • 10
    • 0031886274 scopus 로고    scopus 로고
    • Experimental determination of the convolution kernel for the study of the spatial response of a detector
    • F. García-Vicente, J.M. Delgado, and C. Peraza Experimental determination of the convolution kernel for the study of the spatial response of a detector Med Phys 25 1998 202 207
    • (1998) Med Phys , vol.25 , pp. 202-207
    • García-Vicente, F.1    Delgado, J.M.2    Peraza, C.3
  • 11
    • 0028799438 scopus 로고
    • Deconvolution of detector size effect for small field measurement
    • P. Higgins, C. Sibata, L. Siskind, and J.W. Sohn Deconvolution of detector size effect for small field measurement Med Phys 22 1995 1663 1666
    • (1995) Med Phys , vol.22 , pp. 1663-1666
    • Higgins, P.1    Sibata, C.2    Siskind, L.3    Sohn, J.W.4
  • 12
    • 0003651540 scopus 로고
    • International Commision on Radiological Units (ICRU) International Commission of Radiation Units and Measurement Washington DC
    • International Commision on Radiological Units (ICRU) Report 50. Prescribing, recording, and reporting photon beam therapy 1993 International Commission of Radiation Units and Measurement Washington DC
    • (1993) Report 50. Prescribing, Recording, and Reporting Photon Beam Therapy
  • 13
    • 0035283676 scopus 로고    scopus 로고
    • Late rectal bleeding after conformal radiotherapy of prostate cancer (II): Volume effects and dose-volume histograms
    • A. Jackson, M.W. Skwarchuk, M.J. Zelefsky, D.M. Cowen, and E.S. Venkatraman Late rectal bleeding after conformal radiotherapy of prostate cancer (II): volume effects and dose-volume histograms Int J Rad Oncol Biol Phys 49 2001 685 698
    • (2001) Int J Rad Oncol Biol Phys , vol.49 , pp. 685-698
    • Jackson, A.1    Skwarchuk, M.W.2    Zelefsky, M.J.3    Cowen, D.M.4    Venkatraman, E.S.5
  • 14
    • 0020038518 scopus 로고
    • Changes in the dose profile of a 10 MV X-ray beam within and beyond low density material
    • R.O. Kornelsen, and M.E. Young Changes in the dose profile of a 10 MV X-ray beam within and beyond low density material Med Phys 9 1982 114 116
    • (1982) Med Phys , vol.9 , pp. 114-116
    • Kornelsen, R.O.1    Young, M.E.2
  • 15
    • 0027722289 scopus 로고
    • The penumbra of a 6 MV X-ray beam as measured by thermolumniscent dosimetry and evaluated using an inverse square root function
    • T. Kron, A. Elliot, and P. Metcalfe The penumbra of a 6 MV X-ray beam as measured by thermolumniscent dosimetry and evaluated using an inverse square root function Med Phys 20 1993 1429 1438
    • (1993) Med Phys , vol.20 , pp. 1429-1438
    • Kron, T.1    Elliot, A.2    Metcalfe, P.3
  • 16
    • 0026093854 scopus 로고
    • Histogram reduction method for calculating complication probabilities for three dimensional treatment planning evaluations
    • G.J. Kutcher, C. Burman, and L. Brewster Histogram reduction method for calculating complication probabilities for three dimensional treatment planning evaluations Int J Rad Oncol Biol Phys 21 1991 137 146
    • (1991) Int J Rad Oncol Biol Phys , vol.21 , pp. 137-146
    • Kutcher, G.J.1    Burman, C.2    Brewster, L.3
  • 17
    • 0029003522 scopus 로고
    • A new sigmoidal function describing the small field dose profile data from a linear acelerator
    • C.H. Lam A new sigmoidal function describing the small field dose profile data from a linear acelerator Med Phys 22 1995 543 547
    • (1995) Med Phys , vol.22 , pp. 543-547
    • Lam, C.H.1
  • 18
    • 0037339773 scopus 로고    scopus 로고
    • The volume effect of detectors in the dosimetry of small fields used in IMRT
    • W.U. Laub, and T. Wong The volume effect of detectors in the dosimetry of small fields used in IMRT Med Phys 30 2003 341 347
    • (2003) Med Phys , vol.30 , pp. 341-347
    • Laub, W.U.1    Wong, T.2
  • 19
    • 0022330985 scopus 로고
    • Complication probability as assessed from dose-volume histograms
    • J.T. Lyman Complication probability as assessed from dose-volume histograms Radiat Res Suppl 8 1985 S13 S19
    • (1985) Radiat Res Suppl , vol.8
    • Lyman, J.T.1
  • 20
    • 0036661383 scopus 로고    scopus 로고
    • Verification of the dose to the isocentre in stereotactic plans
    • C. McKerracher, and D.I. Thwaites Verification of the dose to the isocentre in stereotactic plans Radiother Oncol 64 2002 97 107
    • (2002) Radiother Oncol , vol.64 , pp. 97-107
    • McKerracher, C.1    Thwaites, D.I.2
  • 21
    • 0023867758 scopus 로고
    • Generation of photon energy deposition kernels using the EGS Monte Carlo code
    • T.R. Mackie, A.F. Bielajew, D.W.O. Rogers, and J.J. Batista Generation of photon energy deposition kernels using the EGS Monte Carlo code Phys Med Biol 33 1988 1 20
    • (1988) Phys Med Biol , vol.33 , pp. 1-20
    • MacKie, T.R.1    Bielajew, A.F.2    Rogers, D.W.O.3    Batista, J.J.4
  • 22
    • 0021907462 scopus 로고
    • A convolution method of calculating dose for 15-MV X rays
    • T.R. Mackie, J.W. Scrimger, and J.J. Battista A convolution method of calculating dose for 15-MV X rays Med Phys 12 1985 188 196
    • (1985) Med Phys , vol.12 , pp. 188-196
    • MacKie, T.R.1    Scrimger, J.W.2    Battista, J.J.3
  • 24
    • 0034129338 scopus 로고    scopus 로고
    • Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
    • M. Miften, M. Wiesmeyer, S. Monthofer, and K. Krippner Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system Phys Med Biol 45 2000 817 833
    • (2000) Phys Med Biol , vol.45 , pp. 817-833
    • Miften, M.1    Wiesmeyer, M.2    Monthofer, S.3    Krippner, K.4
  • 25
    • 0037295522 scopus 로고    scopus 로고
    • Dosimetric implications of changes in patient repositioning and organ motion in conformal radiotherapy for prostate cancer
    • R. Miralbell, O. Ozsoy, and A. Pugliesi Dosimetric implications of changes in patient repositioning and organ motion in conformal radiotherapy for prostate cancer Radiother Oncol 66 2003 197 202
    • (2003) Radiother Oncol , vol.66 , pp. 197-202
    • Miralbell, R.1    Ozsoy, O.2    Pugliesi, A.3
  • 26
    • 0042884208 scopus 로고    scopus 로고
    • Incorporating clinical measurements of hypoxia into tumor local control modeling of prostate cancer: Implications for the alpha/beta ratio
    • A.E. Nahum, B. Movsas, E.M. Horwitz, C.C. Stobbe, and J.D. Chapman Incorporating clinical measurements of hypoxia into tumor local control modeling of prostate cancer: implications for the alpha/beta ratio Int J Radiat Oncol Biol Phys 57 2003 391 401
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 391-401
    • Nahum, A.E.1    Movsas, B.2    Horwitz, E.M.3    Stobbe, C.C.4    Chapman, J.D.5
  • 27
    • 0004708627 scopus 로고    scopus 로고
    • Netherlands Commission on Radiation Dosimetry (NCS) Netherlands: NCS
    • Netherlands Commission on Radiation Dosimetry (NCS) Quality assurance of treatment planning systems 2000 Netherlands: NCS
    • (2000) Quality Assurance of Treatment Planning Systems
  • 29
  • 30
    • 0034176902 scopus 로고    scopus 로고
    • Late rectal bleeding after conformal radiotherapy of prostate cancer (I): Volume effects and dose-volume histograms
    • M.W. Skwarchuk, A. Jackson, M.J. Zelefsky, E.S. Venkatraman, and D.M. Cowen Late rectal bleeding after conformal radiotherapy of prostate cancer (I): volume effects and dose-volume histograms Int J Rad Oncol Biol Phys 47 2000 103 113
    • (2000) Int J Rad Oncol Biol Phys , vol.47 , pp. 103-113
    • Skwarchuk, M.W.1    Jackson, A.2    Zelefsky, M.J.3    Venkatraman, E.S.4    Cowen, D.M.5
  • 33
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • M. van Herk, A. Bruce, A.P. Kroes, T. Shouman, A. Touw, and J.V. Lebesque Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration Int J Radiat Oncol Biol Phys 33 1995 1311 1320
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Kroes, A.P.3    Shouman, T.4    Touw, A.5    Lebesque, J.V.6
  • 34
    • 85092678024 scopus 로고    scopus 로고
    • Detector line spread functions determined analytically by transport of compton recoil electrons
    • A.A. Van't Veld, P. van Lujik, F. Praamstra, and P.C. Vand der Huslt Detector line spread functions determined analytically by transport of compton recoil electrons Med Phys 28 2001 709 864
    • (2001) Med Phys , vol.28 , pp. 709-864
    • Van'T Veld, A.A.1    Van Lujik, P.2    Praamstra, F.3    Vand Der Huslt, P.C.4
  • 35
    • 0027223126 scopus 로고
    • A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density
    • S. Webb, and A.E. Nahum A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density Phys Med Biol 38 1993 653 666
    • (1993) Phys Med Biol , vol.38 , pp. 653-666
    • Webb, S.1    Nahum, A.E.2
  • 36
    • 3242660045 scopus 로고    scopus 로고
    • Control Bioquímico tras Radioterapia Externa en el Cáncer de Próstata Localizado: Resultados de una Cohorte Moderna
    • A. Zapatero, J.A. Cruz, R. Mínguez, and R. Rodríguez Control Bioquímico tras Radioterapia Externa en el Cáncer de Próstata Localizado: Resultados de una Cohorte Moderna Act Urol Esp 24 2000 10 18
    • (2000) Act Urol Esp , vol.24 , pp. 10-18
    • Zapatero, A.1    Cruz, J.A.2    Mínguez, R.3    Rodríguez, R.4
  • 38
    • 0032917307 scopus 로고    scopus 로고
    • Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy
    • M.J. Zelefsky, D. Crean, and G.S. Mageras Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy Radiother Oncol 50 1999 225 234
    • (1999) Radiother Oncol , vol.50 , pp. 225-234
    • Zelefsky, M.J.1    Crean, D.2    Mageras, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.