Volumn 45, Issue 3, 2000, Pages 645-650

Exact analytical solution of the convolution integral equation for a general profile fitting function and Gaussian detector kernel

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DOSIMETRY; FOURIER TRANSFORMATION; IONIZATION CHAMBER; MATHEMATICAL MODEL; PRIORITY JOURNAL; RADIATION DOSE; RADIATION FIELD; X RAY;

EID: 17344379416     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/45/3/306     Document Type: Article
Times cited : (46)

References (7)
  • 1
    • 0029818463 scopus 로고    scopus 로고
    • The effect of detector size to the broadening of the penumbra-a computer simulated study
    • Chang K-S, Yin F-F and Nie K-W 1996 The effect of detector size to the broadening of the penumbra-a computer simulated study Med. Phys. 23 1407-11
    • (1996) Med. Phys. , vol.23 , pp. 1407-1411
    • Chang, K.-S.1    Yin, F.-F.2    Nie, K.-W.3
  • 2
    • 0031911699 scopus 로고    scopus 로고
    • The use of deconvolution and total least squares in recovering a detector line spread function
    • Charland P, El-Khatib E and Wolters J 1998 The use of deconvolution and total least squares in recovering a detector line spread function Med. Phys. 25 152-60
    • (1998) Med. Phys. , vol.25 , pp. 152-160
    • Charland, P.1    And, E.E.2    Wolters, J.3
  • 3
    • 0031685370 scopus 로고    scopus 로고
    • A spherical dose model for radiosurgery plan optimization
    • Cho P S, Gorkem Kuterdem H and Marks R J II 1998 A spherical dose model for radiosurgery plan optimization Phys. Med. Biol. 43 3145-8
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3145-3148
    • Cho, P.S.1    Gorkem Kuterdem, H.2    Marks R.J. II3
  • 4
    • 0031886274 scopus 로고    scopus 로고
    • Experimental determination of the convolution kernel for the study of the spatial response of a detector
    • García-Vicente F, Delgado J M and Peraza C 1998 Experimental determination of the convolution kernel for the study of the spatial response of a detector Med. Phys. 25 202-7
    • (1998) Med. Phys. , vol.25 , pp. 202-207
    • García-Vicente, F.1    Delgado, J.M.2    Peraza, C.3
  • 5
    • 0028799438 scopus 로고
    • Deconvolution of detector size effect for small field measurement
    • Higgins P, Sibata C, Siskind L and Sohn J W 1995 Deconvolution of detector size effect for small field measurement Med. Phys. 22 1663-6
    • (1995) Med. Phys. , vol.22 , pp. 1663-1666
    • Higgins, P.1    Sibata, C.2    Siskind, L.3    Sohn, J.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.