메뉴 건너뛰기




Volumn 25, Issue 2, 1998, Pages 202-207

Experimental determination of the convolution kernel for the study of the spatial response of a detector

Author keywords

Deconvolution; Kernel; Penumbra

Indexed keywords

CONVOLUTION; DECONVOLUTION; DENSITOMETERS; GAUSSIAN BEAMS; LINEAR ACCELERATORS; METEOROLOGICAL INSTRUMENTS; X RAYS;

EID: 0031886274     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598182     Document Type: Article
Times cited : (78)

References (12)
  • 1
    • 0027741306 scopus 로고
    • Dosimetry of 6 MV x-ray beam penumbra
    • P. Metcalfe, T. Kron, A. Elliot, and T. Wong, "Dosimetry of 6 MV x-ray beam penumbra," Med. Phys. 20, 1439-1445 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1439-1445
    • Metcalfe, P.1    Kron, T.2    Elliot, A.3    Wong, T.4
  • 2
    • 0029818463 scopus 로고    scopus 로고
    • The effect of detector size to the broadening of the penumbra-A computer simulated study
    • K.-S. Chang, F.-F. Yin, and K.-W. Nie, "The effect of detector size to the broadening of the penumbra-A computer simulated study," Med. Phys. 23, 1407-1411 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1407-1411
    • Chang, K.-S.1    Yin, F.-F.2    Nie, K.-W.3
  • 3
    • 0028799438 scopus 로고
    • Deconvolution of detector size effect for small field measurement
    • P. Higgins, C. Sibata, L. Siskind, and J. W. Sohn, "Deconvolution of detector size effect for small field measurement," Med. Phys. 22, 1663-1666 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1663-1666
    • Higgins, P.1    Sibata, C.2    Siskind, L.3    Sohn, J.W.4
  • 4
    • 0027722289 scopus 로고
    • The penumbra of a 6 MV x-ray beam as measured by thermolumniscent dosimetry and evaluated using an inverse square root function
    • T. Kron, A. Elliot, and P. Metcalfe, "The penumbra of a 6 MV x-ray beam as measured by thermolumniscent dosimetry and evaluated using an inverse square root function," Med. Phys. 20, 1429-1438 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1429-1438
    • Kron, T.1    Elliot, A.2    Metcalfe, P.3
  • 5
    • 0021227635 scopus 로고
    • Analysis of physical parameters associated with the measurement of high energy x-ray penumbra
    • D. J. Dawson, J. M Harper, and A. C. Akinradewo, "Analysis of physical parameters associated with the measurement of high energy x-ray penumbra," Med. Phys. 11, 491-497 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 491-497
    • Dawson, D.J.1    Harper, J.M.2    Akinradewo, A.C.3
  • 8
    • 85027238100 scopus 로고    scopus 로고
    • Scanditronix RT Divisionen (private communication)
    • Scanditronix RT Divisionen (private communication).
  • 9
    • 85027225534 scopus 로고
    • Verfahren zur Dosiskalibrierung in der Filmdosimetrie ohne externe Eichung
    • Abstract book of the yearly Congress of the German Association of Medical Physics, Bonn, edited by G. Miller and J. Erb.
    • Daniel Skerhut and Rudolf Klepper, "Verfahren zur Dosiskalibrierung in der Filmdosimetrie ohne externe Eichung," in Medizinische Physik 1993, Abstract book of the yearly Congress of the German Association of Medical Physics, Bonn, 1993, edited by G. Miller and J. Erb.
    • (1993) Medizinische Physik 1993
    • Skerhut, D.1    Klepper, R.2
  • 10
    • 0000169232 scopus 로고
    • An algorithm for least squares estimation of nonlinear-parameters
    • D W Marquardt, "An algorithm for least squares estimation of nonlinear-parameters," J. Soc Ind. Appl. Math. 11, 431-441 (1963).
    • (1963) J. Soc Ind. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.