메뉴 건너뛰기




Volumn 28, Issue 1, 2005, Pages 18-23

Experience of stereotactic breast biopsy using the vacuum-assisted core needle biopsy device and the advanced breast biopsy instrumentation system in Hong Kong women

Author keywords

ABBI; Mammotome; Stereotactic breast biopsy; Vacuum assisted core needle biopsy

Indexed keywords

ADULT; AGED; ARTICLE; BLEEDING; BREAST BIOPSY; CANCER CYTODIAGNOSIS; CAPILLARY RESISTANCE; DEVICE; ECHOGRAPHY; FEASIBILITY STUDY; FEMALE; HISTOPATHOLOGY; HONG KONG; HUMAN; INSTRUMENTATION; MAJOR CLINICAL STUDY; MAMMOGRAPHY; STEREOTAXIC SURGERY; VACUUM ASSISTED CORE NEEDLE BIOPSY;

EID: 14644388161     PISSN: 10159584     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1015-9584(09)60252-9     Document Type: Article
Times cited : (11)

References (21)
  • 1
    • 0024558606 scopus 로고
    • Fine-needle aspiration of clinically occult breast lesions
    • Kopan DB. Fine-needle aspiration of clinically occult breast lesions. Radiology 1989;170:313-4.
    • (1989) Radiology , vol.170 , pp. 313-314
    • Kopan, D.B.1
  • 2
    • 0032520104 scopus 로고    scopus 로고
    • Rate of insufficient samples for fine-needle aspiration for nonpalpable breast lesions in a multicenter clinical trial
    • Pisano ED, Fajardo LL, Tsimikas J, et al. Rate of insufficient samples for fine-needle aspiration for nonpalpable breast lesions in a multicenter clinical trial. Cancer 1998;82:679-88.
    • (1998) Cancer , vol.82 , pp. 679-688
    • Pisano, E.D.1    Fajardo, L.L.2    Tsimikas, J.3
  • 3
    • 0025886119 scopus 로고
    • Nonpalpable breast lesions: Stereotactic automated large-core biopsies
    • Parker SH, Lovin JD, Jobe WR, et al. Nonpalpable breast lesions: stereotactic automated large-core biopsies. Radiology 1991;180:403-7.
    • (1991) Radiology , vol.180 , pp. 403-407
    • Parker, S.H.1    Lovin, J.D.2    Jobe, W.R.3
  • 4
    • 0027170041 scopus 로고
    • Nonpalpable breast lesions: Correlation of stereotaxic large core needle biopsy and surgical biopsy results
    • Elvecrog EL, Lechner MC, Nelson MT. Nonpalpable breast lesions: correlation of stereotaxic large core needle biopsy and surgical biopsy results. Radiology 1993;188:453-5.
    • (1993) Radiology , vol.188 , pp. 453-455
    • Elvecrog, E.L.1    Lechner, M.C.2    Nelson, M.T.3
  • 5
    • 0026763044 scopus 로고
    • Stereotaxic core biopsy of breast lesions
    • Dronkers DJ. Stereotaxic core biopsy of breast lesions. Radiology 1992;183:631-4.
    • (1992) Radiology , vol.183 , pp. 631-634
    • Dronkers, D.J.1
  • 6
    • 0028091666 scopus 로고
    • Percutaneous large core breast biopsy: A multi-institutional study
    • Parker SH, Burbank F, Jackman RJ, et al. Percutaneous large core breast biopsy: a multi-institutional study. Radiology 1994;193:359-64.
    • (1994) Radiology , vol.193 , pp. 359-364
    • Parker, S.H.1    Burbank, F.2    Jackman, R.J.3
  • 7
    • 0028861995 scopus 로고
    • Automated large-core needle biopsy of surgically removed breast lesions: Comparison of samples obtained with 14-, 16-, and 18-gauge needles
    • Nath ME, Robinson TM, Tobon H, et al. Automated large-core needle biopsy of surgically removed breast lesions: comparison of samples obtained with 14-, 16-, and 18-gauge needles. Radiology 1995;197:739-42.
    • (1995) Radiology , vol.197 , pp. 739-742
    • Nath, M.E.1    Robinson, T.M.2    Tobon, H.3
  • 8
    • 0030770302 scopus 로고    scopus 로고
    • Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model
    • Berg WA, Krebs TL, Campassi C, et al. Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 1997;205:203-8.
    • (1997) Radiology , vol.205 , pp. 203-208
    • Berg, W.A.1    Krebs, T.L.2    Campassi, C.3
  • 9
    • 13344259979 scopus 로고    scopus 로고
    • Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy
    • Brenner RJ, Fajardo L, Fisher PR, et al. Percutaneous core biopsy of the breast: effect of operator experience and number of samples on diagnostic accuracy. AJR Am J Roentgenol 1996;166:341-6.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 341-346
    • Brenner, R.J.1    Fajardo, L.2    Fisher, P.R.3
  • 10
    • 0028074790 scopus 로고
    • Stereotaxic 14-gauge breast biopsy: How many core biopsy specimens are needed?
    • Liberman L, Dershaw DD, Rosen PP, et al. Stereotaxic 14-gauge breast biopsy: how many core biopsy specimens are needed? Radiology 1994;192:793-5.
    • (1994) Radiology , vol.192 , pp. 793-795
    • Liberman, L.1    Dershaw, D.D.2    Rosen, P.P.3
  • 11
    • 0031878450 scopus 로고    scopus 로고
    • Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy
    • Liberman L, Smolkin JH, Dershaw DD, et al. Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy. Radiology 1998;208:251-60.
    • (1998) Radiology , vol.208 , pp. 251-260
    • Liberman, L.1    Smolkin, J.H.2    Dershaw, D.D.3
  • 12
    • 0031055857 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    • Burbank F. Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: improved accuracy with directional, vacuum-assisted biopsy. Radiology 1997;202:843-7.
    • (1997) Radiology , vol.202 , pp. 843-847
    • Burbank, F.1
  • 13
    • 0031771461 scopus 로고    scopus 로고
    • Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques
    • Jackman RJ, Marzoni FA, Nowels KW. Percutaneous removal of benign mammographic lesions: comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques. AJR Am J Roentgenol 1998;171:1325-30.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 1325-1330
    • Jackman, R.J.1    Marzoni, F.A.2    Nowels, K.W.3
  • 14
    • 0030876771 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device
    • Meyer JE, Smith DN, DiPiro PJ, et al. Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device. Radiology 1997;204:575-6.
    • (1997) Radiology , vol.204 , pp. 575-576
    • Meyer, J.E.1    Smith, D.N.2    DiPiro, P.J.3
  • 15
    • 0030867513 scopus 로고    scopus 로고
    • Stereotactic excisional breast biopsies utilizing the advanced breast biopsy instrumentation system
    • D'Angelo PC, Galliano DE, Rosemurgy AS. Stereotactic excisional breast biopsies utilizing the advanced breast biopsy instrumentation system. Am J Surg 1997;174:297-302.
    • (1997) Am J Surg , vol.174 , pp. 297-302
    • D'Angelo, P.C.1    Galliano, D.E.2    Rosemurgy, A.S.3
  • 16
    • 0033002394 scopus 로고    scopus 로고
    • Initial experience with the advanced breast biopsy instrumentation system
    • Matthews BD, Williams GB. Initial experience with the advanced breast biopsy instrumentation system. Am J Surg 1999;177:97-101.
    • (1999) Am J Surg , vol.177 , pp. 97-101
    • Matthews, B.D.1    Williams, G.B.2
  • 17
    • 0029938332 scopus 로고    scopus 로고
    • A practical approach to minimally invasive breast biopsy
    • Parker SH, Burbank F. A practical approach to minimally invasive breast biopsy. Radiology 1996;200:11-20.
    • (1996) Radiology , vol.200 , pp. 11-20
    • Parker, S.H.1    Burbank, F.2
  • 19
    • 0032461667 scopus 로고    scopus 로고
    • Image guided core needle breast biopsy is an accurate technique to evaluate patients with nonpalpable imaging abnormalities
    • Furhman GM, Cederbom GJ, Bolton JS, et al. Image guided core needle breast biopsy is an accurate technique to evaluate patients with nonpalpable imaging abnormalities. Ann Surg 1998;227:932-9.
    • (1998) Ann Surg , vol.227 , pp. 932-939
    • Furhman, G.M.1    Cederbom, G.J.2    Bolton, J.S.3
  • 20
    • 0028209564 scopus 로고
    • Breast biopsy: A comparative study of stereotaxically guided core and excisional techniques
    • Gisvold JJ, Goeliner JR, Grant CS, et al. Breast biopsy: a comparative study of stereotaxically guided core and excisional techniques. AJR Am J Roentgenol 1994;162:815-20.
    • (1994) AJR Am J Roentgenol , vol.162 , pp. 815-820
    • Gisvold, J.J.1    Goeliner, J.R.2    Grant, C.S.3
  • 21
    • 0030949481 scopus 로고    scopus 로고
    • Large-core needle biopsy of nonpalpable breast cancers: The impact on subsequent surgical excisions
    • Smith DN, Christian R, Meyer JE. Large-core needle biopsy of nonpalpable breast cancers: the impact on subsequent surgical excisions. Arch Surg 1997;132:256-9.
    • (1997) Arch Surg , vol.132 , pp. 256-259
    • Smith, D.N.1    Christian, R.2    Meyer, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.