메뉴 건너뛰기




Volumn 12, Issue 2, 2005, Pages 155-163

3D contrast-enhanced MR angiography of the abdominal aorta and its distal branches: Interobserver agreement of radiologists in a routine examination

Author keywords

Angiography; Aorta; Magnetic resonance; Visceral arteries

Indexed keywords

ABDOMINAL AORTA; ADULT; AGED; ANEURYSM; ARTERY THROMBOSIS; ARTICLE; BLOOD VESSEL FISTULA; CELIAC ARTERY; CELIAC ARTERY STENOSIS; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; MAGNETIC RESONANCE ANGIOGRAPHY; MAJOR CLINICAL STUDY; MALE; MEDICAL EXAMINATION; OBSERVER VARIATION; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; SIGNAL NOISE RATIO; SUPERIOR MESENTERIC ARTERY; SUPERIOR MESENTERIC ARTERY OBSTRUCTION; THREE DIMENSIONAL IMAGING;

EID: 13944259779     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2004.10.060     Document Type: Article
Times cited : (13)

References (33)
  • 1
    • 0028845732 scopus 로고
    • Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches
    • M.R. Prince, D.L. Narasimham, J.C. Stanley Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches Radiology 197 1995 785 792
    • (1995) Radiology , vol.197 , pp. 785-792
    • Prince, M.R.1    Narasimham, D.L.2    Stanley, J.C.3
  • 2
    • 0033985684 scopus 로고    scopus 로고
    • Comparing contrast-enhanced breath-hold MR angiography and conventional angiography in the evaluation of mesenteric circulation
    • O. Ernst, V. Asnar, G. Sergent Comparing contrast-enhanced breath-hold MR angiography and conventional angiography in the evaluation of mesenteric circulation AJR Am J Roentgenol 174 2000 433 439
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 433-439
    • Ernst, O.1    Asnar, V.2    Sergent, G.3
  • 3
    • 0032471003 scopus 로고    scopus 로고
    • Arterial-phase three-dimensional gadolinium magnetic resonance angiography of the renal arteries. Strategies for timing and contrast media injection: Original investigation
    • S.O. Schoenberg, M.V. Knopp, M.R. Prince Arterial-phase three-dimensional gadolinium magnetic resonance angiography of the renal arteries. Strategies for timing and contrast media injection original investigation Invest Radiol 33 1998 506 514
    • (1998) Invest Radiol , vol.33 , pp. 506-514
    • Schoenberg, S.O.1    Knopp, M.V.2    Prince, M.R.3
  • 4
    • 0033997180 scopus 로고    scopus 로고
    • Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: Design specifications and technical reliability in 330 patient studies
    • S.J. Riederer, M.A. Bernstein, J.F. Breen Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering design specifications and technical reliability in 330 patient studies Radiology 215 2000 584 593
    • (2000) Radiology , vol.215 , pp. 584-593
    • Riederer, S.J.1    Bernstein, M.A.2    Breen, J.F.3
  • 5
    • 0036136417 scopus 로고    scopus 로고
    • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: Results of a bicenter multireader analysis
    • S.O. Schoenberg, M. Essig, P. Hallscheidt Multiphase magnetic resonance angiography of the abdominal and pelvic arteries results of a bicenter multireader analysis Invest Radiol 37 2002 20 28
    • (2002) Invest Radiol , vol.37 , pp. 20-28
    • Schoenberg, S.O.1    Essig, M.2    Hallscheidt, P.3
  • 6
    • 0035078791 scopus 로고    scopus 로고
    • Safety and effectiveness of single- versus triple-dose gadodiamide injection- enhanced MR angiography of the abdomen: A phase III double-blind multicenter study
    • S.A. Thurnher, A. Capelastegui, F.H. Del Olmo Safety and effectiveness of single- versus triple-dose gadodiamide injection- enhanced MR angiography of the abdomen a phase III double-blind multicenter study Radiology 219 2001 137 146
    • (2001) Radiology , vol.219 , pp. 137-146
    • Thurnher, S.A.1    Capelastegui, A.2    Del Olmo, F.H.3
  • 7
    • 0031021236 scopus 로고    scopus 로고
    • Mesenteric circulation: Three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique
    • A. Shirkhoda, O. Konez, A.N. Shetty Mesenteric circulation three-dimensional MR angiography with a gadolinium-enhanced multiecho gradient-echo technique Radiology 202 1997 257 261
    • (1997) Radiology , vol.202 , pp. 257-261
    • Shirkhoda, A.1    Konez, O.2    Shetty, A.N.3
  • 8
    • 0031961415 scopus 로고    scopus 로고
    • Vascular complications of liver transplantation: Evaluation with gadolinium-enhanced MR angiography
    • D.B. Stafford-Johnson, B.H. Hamilton, Q. Dong Vascular complications of liver transplantation evaluation with gadolinium-enhanced MR angiography Radiology 207 1998 153 160
    • (1998) Radiology , vol.207 , pp. 153-160
    • Stafford-Johnson, D.B.1    Hamilton, B.H.2    Dong, Q.3
  • 9
    • 0031421928 scopus 로고    scopus 로고
    • Gadolinium-enhanced MR angiography of visceral arteries in patients with suspected chronic mesenteric ischemia
    • J.F. Meaney, M.R. Prince, T.T. Nostrant, J.C. Stanley Gadolinium-enhanced MR angiography of visceral arteries in patients with suspected chronic mesenteric ischemia J Magn Reson Imag 7 1997 171 176
    • (1997) J Magn Reson Imag , vol.7 , pp. 171-176
    • Meaney, J.F.1    Prince, M.R.2    Nostrant, T.T.3    Stanley, J.C.4
  • 12
    • 0030945180 scopus 로고    scopus 로고
    • Contrast-enhanced abdominal MR angiography: Optimisation of imaging delay time by automating the detection contrast material arrival in the aorta
    • M.R. Prince, T.L. Chenevert, T.K. Foo Contrast-enhanced abdominal MR angiography optimisation of imaging delay time by automating the detection contrast material arrival in the aorta Radiology 203 1997 109 114
    • (1997) Radiology , vol.203 , pp. 109-114
    • Prince, M.R.1    Chenevert, T.L.2    Foo, T.K.3
  • 13
    • 0033845463 scopus 로고    scopus 로고
    • 3D MR DSA: Effects of injection protocol and image masking
    • R. Frayne, T.M. Grist, J.S. Swan 3D MR DSA effects of injection protocol and image masking JMRI 12 2000 476 487
    • (2000) JMRI , vol.12 , pp. 476-487
    • Frayne, R.1    Grist, T.M.2    Swan, J.S.3
  • 14
    • 0032905724 scopus 로고    scopus 로고
    • Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries
    • V.S. Lee, N.M. Rofsky, G.A. Krinsky Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries Radiology 211 1999 69 78
    • (1999) Radiology , vol.211 , pp. 69-78
    • Lee, V.S.1    Rofsky, N.M.2    Krinsky, G.A.3
  • 15
    • 0029805810 scopus 로고    scopus 로고
    • Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    • J.P. Earls, N.M. Rofsky, D.R. DeCorato Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography usefulness of a timing examination and MR power injector Radiology 201 1996 705 710
    • (1996) Radiology , vol.201 , pp. 705-710
    • Earls, J.P.1    Rofsky, N.M.2    Decorato, D.R.3
  • 16
    • 0031403950 scopus 로고    scopus 로고
    • Optimization of contrast timing for breath-hold three-dimensional MR angiography
    • T.F. Hany, G.C. McKinnon, D.A. Leung Optimization of contrast timing for breath-hold three-dimensional MR angiography J Magn Reson Imag 7 1997 551 556
    • (1997) J Magn Reson Imag , vol.7 , pp. 551-556
    • Hany, T.F.1    McKinnon, G.C.2    Leung, D.A.3
  • 17
    • 0030770299 scopus 로고    scopus 로고
    • Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    • A.H. Wilman, S.J. Riederer, B.F. King Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order application to the renal arteries Radiology 205 1997 137 146
    • (1997) Radiology , vol.205 , pp. 137-146
    • Wilman, A.H.1    Riederer, S.J.2    King, B.F.3
  • 19
    • 0343986506 scopus 로고    scopus 로고
    • Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: Time-resolved imaging versus single-phase imaging
    • L. Van Hoe, T. De Jaegere, H. Bosmans Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen time-resolved imaging versus single-phase imaging Radiology 214 2000 149 156
    • (2000) Radiology , vol.214 , pp. 149-156
    • Van Hoe, L.1    De Jaegere, T.2    Bosmans, H.3
  • 20
    • 0035140372 scopus 로고    scopus 로고
    • High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography
    • S.B. Fain, B.F. King, J.F. Breen High-spatial-resolution contrast-enhanced MR angiography of the renal arteries a prospective comparison with digital subtraction angiography Radiology 218 2001 481 490
    • (2001) Radiology , vol.218 , pp. 481-490
    • Fain, S.B.1    King, B.F.2    Breen, J.F.3
  • 21
    • 0034198673 scopus 로고    scopus 로고
    • Contrast-enhanced MR Angiography of the epigastric and hepatic regions: Visibility in 3D reconstructions
    • G.O. Sakai, G. Nishida, N. Yamada, R. Matsuoka Contrast-enhanced MR Angiography of the epigastric and hepatic regions visibility in 3D reconstructions Osaka City Med J 46 2000 1 8
    • (2000) Osaka City Med J , vol.46 , pp. 1-8
    • Sakai, G.O.1    Nishida, G.2    Yamada, N.3    Matsuoka, R.4
  • 22
    • 0033841357 scopus 로고    scopus 로고
    • Abdomen, pelvis, and extremities: Diagnostic accuracy of dynamic contrast-enhanced turbo MR angiography compared with conventional angiography-initial experience
    • K. Mitsuzaki, Y. Yamashita, T. Sakaguchi Abdomen, pelvis, and extremities diagnostic accuracy of dynamic contrast-enhanced turbo MR angiography compared with conventional angiography-initial experience Radiology 216 2000 909 915
    • (2000) Radiology , vol.216 , pp. 909-915
    • Mitsuzaki, K.1    Yamashita, Y.2    Sakaguchi, T.3
  • 24
    • 0032882776 scopus 로고    scopus 로고
    • Abdominal MR imaging with a volumetric interpolated breath-hold examination
    • N.M. Rofsky, V.S. Lee, G. Laub Abdominal MR imaging with a volumetric interpolated breath-hold examination Radiology 212 1999 876 884
    • (1999) Radiology , vol.212 , pp. 876-884
    • Rofsky, N.M.1    Lee, V.S.2    Laub, G.3
  • 25
    • 0035142169 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced three-dimensional MR imaging of liver parenchyma: Source images and angiographic reconstructions to define hepatic arterial anatomy
    • M.T. Lavelle, V.S. Lee, N.M. Rofsky Dynamic contrast-enhanced three-dimensional MR imaging of liver parenchyma source images and angiographic reconstructions to define hepatic arterial anatomy Radiology 218 2001 389 394
    • (2001) Radiology , vol.218 , pp. 389-394
    • Lavelle, M.T.1    Lee, V.S.2    Rofsky, N.M.3
  • 26
    • 0025070034 scopus 로고
    • Artifacts in maximum-intensity-projection display of MR angiograms
    • C.M. Anderson, D. Saloner, J.S. Tsuruda Artifacts in maximum-intensity- projection display of MR angiograms AJR Am J Roentgenol 154 1990 623 629
    • (1990) AJR Am J Roentgenol , vol.154 , pp. 623-629
    • Anderson, C.M.1    Saloner, D.2    Tsuruda, J.S.3
  • 27
    • 0031227469 scopus 로고    scopus 로고
    • Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    • C.P. Davis, T.F. Hany, S. Wildermuth Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography Radiographics 17 1997 1061 1077
    • (1997) Radiographics , vol.17 , pp. 1061-1077
    • Davis, C.P.1    Hany, T.F.2    Wildermuth, S.3
  • 28
    • 0033917477 scopus 로고    scopus 로고
    • Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography
    • P.R. Hilfiker, R.J. Herfkens, S.G. Heiss Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography Radiology 216 2000 298 303
    • (2000) Radiology , vol.216 , pp. 298-303
    • Hilfiker, P.R.1    Herfkens, R.J.2    Heiss, S.G.3
  • 29
    • 0032903632 scopus 로고    scopus 로고
    • Hepatic blood supply: Comparison of optimized dual phase contrast-enhanced three-dimensional MR angiography and digital subtraction angiography
    • L. Kopka, J. Rodenwaldt, R. Vosshenrich Hepatic blood supply comparison of optimized dual phase contrast-enhanced three-dimensional MR angiography and digital subtraction angiography Radiology 211 1999 51 58
    • (1999) Radiology , vol.211 , pp. 51-58
    • Kopka, L.1    Rodenwaldt, J.2    Vosshenrich, R.3
  • 30
    • 0028362925 scopus 로고
    • Surgical anatomy of the hepatic arteries in 1000 cases
    • J.R. Hiatt, J. Gabbay, R.W. Busuttil Surgical anatomy of the hepatic arteries in 1000 cases Ann Surg 220 1994 50 52
    • (1994) Ann Surg , vol.220 , pp. 50-52
    • Hiatt, J.R.1    Gabbay, J.2    Busuttil, R.W.3
  • 31
    • 0029339116 scopus 로고
    • Hepatic arterial anatomy: Demonstration of normal supply and vascular variants with three dimensional CT angiography
    • T.C. Winter III, H.V. Nghiem, P.C. Freeny Hepatic arterial anatomy demonstration of normal supply and vascular variants with three dimensional CT angiography Radiographics 15 1995 771 780
    • (1995) Radiographics , vol.15 , pp. 771-780
    • Winter III, T.C.1    Nghiem, H.V.2    Freeny, P.C.3
  • 32
    • 0036136135 scopus 로고    scopus 로고
    • Multi-detector row helical CT angiography of hepatic vessels: Depiction with dual-arterial phase acquisition during single breath hold
    • S. Takahashi, T. Murakami, M. Takamura Multi-detector row helical CT angiography of hepatic vessels depiction with dual-arterial phase acquisition during single breath hold Radiology 222 2002 81 88
    • (2002) Radiology , vol.222 , pp. 81-88
    • Takahashi, S.1    Murakami, T.2    Takamura, M.3
  • 33
    • 0029680085 scopus 로고    scopus 로고
    • Nephrotoxicity of high-dose gadolinium compared with iodinated contrast
    • M.R. Prince, C. Arnoldus, J. Frisoli Nephrotoxicity of high-dose gadolinium compared with iodinated contrast J Magn Reson Imag 1 1996 162 166
    • (1996) J Magn Reson Imag , vol.1 , pp. 162-166
    • Prince, M.R.1    Arnoldus, C.2    Frisoli, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.