메뉴 건너뛰기




Volumn 7, Issue 3, 1997, Pages 551-556

Optimization of contrast timing for breath-hold three-dimensional MR angiography

Author keywords

Bolus kinetics; Bolus timing; Contrast enhanced three dimensional MR angiography; Optimization; Test bolus application

Indexed keywords

GADOLINIUM PENTETATE;

EID: 0031403950     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880070316     Document Type: Article
Times cited : (162)

References (11)
  • 1
    • 0027690838 scopus 로고
    • Dynamic gadolinium-enhanced three-dimensional abdominal MR angiography
    • Prince MR, Yucel EK, Kaufman JA, Harrison DC, Geller SC. Dynamic gadolinium-enhanced three-dimensional abdominal MR angiography. JMRI 1993; 3:877-881.
    • (1993) JMRI , vol.3 , pp. 877-881
    • Prince, M.R.1    Yucel, E.K.2    Kaufman, J.A.3    Harrison, D.C.4    Geller, S.C.5
  • 2
    • 0028845732 scopus 로고
    • Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and Its major branches
    • Prince MR, Narasimham DL, Stanley JC, et al. Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and Its major branches. Radiology 1995; 197:785-792.
    • (1995) Radiology , vol.197 , pp. 785-792
    • Prince, M.R.1    Narasimham, D.L.2    Stanley, J.C.3
  • 3
    • 0029937898 scopus 로고    scopus 로고
    • Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries
    • Holland GA, Dougherty L, Carpenter JP, Axel L. Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries. AJR Am J Roentgenol 1996; 166:971-981.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 971-981
    • Holland, G.A.1    Dougherty, L.2    Carpenter, J.P.3    Axel, L.4
  • 4
    • 0030040997 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced MR angiography for aortoiliac Inflow assessment plus renal artery screening in a single breath hold
    • Snidow JJ, Johnson MS, Harris VJ, Trerotola SO. Three-dimensional gadolinium-enhanced MR angiography for aortoiliac Inflow assessment plus renal artery screening In a single breath hold. Radiology 1996; 198:725-732.
    • (1996) Radiology , vol.198 , pp. 725-732
    • Snidow, J.J.1    Johnson, M.S.2    Harris, V.J.3    Trerotola, S.O.4
  • 6
    • 0020644027 scopus 로고
    • The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods
    • Twieg DB. The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. Med Phys 1983; 10(5):610-621.
    • (1983) Med Phys , vol.10 , Issue.5 , pp. 610-621
    • Twieg, D.B.1
  • 8
    • 0029047087 scopus 로고
    • A proposed blood circulation model for reference man
    • Leggett RW, Williams LR. A proposed blood circulation model for reference man. Health Phys 1995; 2:187-201.
    • (1995) Health Phys , vol.2 , pp. 187-201
    • Leggett, R.W.1    Williams, L.R.2
  • 10
    • 0025270190 scopus 로고
    • Abdominal aorta and renal artery stenosis: Evaluation with MR angiography
    • Kim D, Edelaman RR, Kent KC, Porter DH, Skillman JJ. Abdominal aorta and renal artery stenosis: evaluation with MR angiography. Radiology 1990; 174:727-731.
    • (1990) Radiology , vol.174 , pp. 727-731
    • Kim, D.1    Edelaman, R.R.2    Kent, K.C.3    Porter, D.H.4    Skillman, J.J.5
  • 11
    • 0028157491 scopus 로고
    • Comparison of three-dimensional rendering techniques
    • Rubin GD, Dake MD, Napel S, et al. Comparison of three-dimensional rendering techniques. Radiology 1994; 190:181-189.
    • (1994) Radiology , vol.190 , pp. 181-189
    • Rubin, G.D.1    Dake, M.D.2    Napel, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.