메뉴 건너뛰기




Volumn 19, Issue 2, 2004, Pages 230-234

The Pumping of Fluid in Cementless Cups with Holes

Author keywords

Pelvic osteolysis; Polyethylene; Pressure; Pump; Screw holes; Total hip arthroplasty

Indexed keywords

POLYETHYLENE;

EID: 1242342260     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2003.10.005     Document Type: Article
Times cited : (25)

References (16)
  • 1
    • 0034998825 scopus 로고    scopus 로고
    • Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation
    • Tonino A, Oosterbos C, Rahmy A, et al: Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation. J Bone Joint Surg Am 83:817, 2001
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 817
    • Tonino, A.1    Oosterbos, C.2    Rahmy, A.3
  • 2
    • 0026442786 scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years
    • Schmalzried TP, Harris WH: The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years. J Bone Joint Surg Am 74: 1130, 1992
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1130
    • Schmalzried, T.P.1    Harris, W.H.2
  • 3
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk OL, Bansal M, Betts F, et al: Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg Br 76:568, 1994
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 568
    • Huk, O.L.1    Bansal, M.2    Betts, F.3
  • 4
    • 0029886633 scopus 로고    scopus 로고
    • The porous-coated anatomic total hip prosthesis: Failure of the metal-backed acetabular component
    • Astion DJ, Saluan P, Stulberg BN, et al: The porous-coated anatomic total hip prosthesis: failure of the metal-backed acetabular component. J Bone Joint Surg Am 78:755, 1996
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 755
    • Astion, D.J.1    Saluan, P.2    Stulberg, B.N.3
  • 5
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried TP, Jasty M, Harris WH: Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 74:849, 1992
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 849
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 6
    • 0030857287 scopus 로고    scopus 로고
    • Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips
    • Robertsson O, Wingstrand H, Kesteris U, et al: Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips. Acta Orthop Scand 68:231, 1997
    • (1997) Acta Orthop Scand , vol.68 , pp. 231
    • Robertsson, O.1    Wingstrand, H.2    Kesteris, U.3
  • 7
    • 0020616988 scopus 로고
    • Arthrography after total hip arthroplasty: A modified technique used in the diagnosis of pain
    • Hendrix RW, Wixson RL, Rana NA, Rogers LF: Arthrography after total hip arthroplasty: a modified technique used in the diagnosis of pain. Radiology 148:647, 1983
    • (1983) Radiology , vol.148 , pp. 647
    • Hendrix, R.W.1    Wixson, R.L.2    Rana, N.A.3    Rogers, L.F.4
  • 8
    • 0032741236 scopus 로고    scopus 로고
    • Motion at the modular acetabular shell and liner interface. A comparative study
    • Fehring TK, Smith SE, Braun ER, et al: Motion at the modular acetabular shell and liner interface. A comparative study. Clin Orthop 367:306, 1999
    • (1999) Clin Orthop , vol.367 , pp. 306
    • Fehring, T.K.1    Smith, S.E.2    Braun, E.R.3
  • 9
    • 0031059184 scopus 로고    scopus 로고
    • Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups
    • Williams VG 2nd, Whiteside LA, White SE, et al: Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups. J Arthroplasty 12:25, 1997
    • (1997) J Arthroplasty , vol.12 , pp. 25
    • Williams II, V.G.1    Whiteside, L.A.2    White, S.E.3
  • 10
    • 0033957831 scopus 로고    scopus 로고
    • Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearings made of hylamer
    • Scott DL, Campbell PA, McClung CD, et al: Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearings made of hylamer. J Arthroplasty 15:35, 2000
    • (2000) J Arthroplasty , vol.15 , pp. 35
    • Scott, D.L.1    Campbell, P.A.2    McClung, C.D.3
  • 11
    • 0036054774 scopus 로고    scopus 로고
    • Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    • Young AM, Sychterz CJ, Hopper RH Jr, et al: Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84:58, 2002
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 58
    • Young, A.M.1    Sychterz, C.J.2    Hopper Jr., R.H.3
  • 12
    • 0036913856 scopus 로고    scopus 로고
    • Osteolysis: A disease of access to fixation interfaces
    • Manley MT, D'Antonio JA, Capello WN, et al: Osteolysis: a disease of access to fixation interfaces. Clin Orthop 405:129, 2002
    • (2002) Clin Orthop , vol.405 , pp. 129
    • Manley, M.T.1    D'Antonio, J.A.2    Capello, W.N.3
  • 13
    • 33645211610 scopus 로고    scopus 로고
    • Bone ingrowth conditions are sensitive to the presence of trapped periacetabular fluid
    • New Orleans, LA
    • Ong K, Bartel D: Bone ingrowth conditions are sensitive to the presence of trapped periacetabular fluid. In 49th Annual Meeting of the ORS, New Orleans, LA, 2003
    • (2003) 49th Annual Meeting of the ORS
    • Ong, K.1    Bartel, D.2
  • 14
    • 0035217507 scopus 로고    scopus 로고
    • Pattern of osteolysis around two different cementless metal-backed cups: Retrospective, radiographic analysis at minimum 10-year follow-up
    • Claus AM, Sychterz CJ, Hopper RH Jr., et al: Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty 16:177, 2001
    • (2001) J Arthroplasty , vol.16 , pp. 177
    • Claus, A.M.1    Sychterz, C.J.2    Hopper Jr., R.H.3
  • 15
    • 0032610896 scopus 로고    scopus 로고
    • The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis
    • Schmalzried TP, Brown IC, Amstutz HC, et al: The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis. Proc Inst Mech Eng [H] 213:147, 1999
    • (1999) Proc Inst Mech Eng [H] , vol.213 , pp. 147
    • Schmalzried, T.P.1    Brown, I.C.2    Amstutz, H.C.3
  • 16


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.