메뉴 건너뛰기




Volumn 34, Issue 2, 2004, Pages 141-152

Computer assisted optimization of an electromagnetic transducer design for implantable hearing aids

Author keywords

Computer simulations; Electromagnetic transducers; Hearing aids; Implantable devices; Middle ear

Indexed keywords

COMPUTER SIMULATION; ELECTRIC COILS; ELECTROMAGNETISM; HEARING AIDS; IMPLANTS (SURGICAL); OPTIMIZATION; PERMANENT MAGNETS; PRODUCT DESIGN;

EID: 1242276508     PISSN: 00104825     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0010-4825(03)00042-8     Document Type: Article
Times cited : (6)

References (18)
  • 1
    • 0141693330 scopus 로고    scopus 로고
    • Current status and critical reflections on implantable hearing aids
    • Hüttenbrink K.B. Current status and critical reflections on implantable hearing aids. Am. J. Otol. 20(4):1999;409-415.
    • (1999) Am. J. Otol. , vol.20 , Issue.4 , pp. 409-415
    • Hüttenbrink, K.B.1
  • 2
    • 0242556367 scopus 로고    scopus 로고
    • Implantable electronic otologic devices: State of the art
    • A.J. Maniglia, D.W. Proops (Eds.), Implantable electronic otologic devices: state of the art, Otolaryngol. Clin. North Am. 34(2) (2001) 1-220.
    • (2001) Otolaryngol. Clin. North Am. , vol.34 , Issue.2 , pp. 1-220
    • Maniglia, A.J.1    Proops, D.W.2
  • 4
    • 0034993012 scopus 로고    scopus 로고
    • Total implantation of the Implex TICA hearing amplifier implant for high frequency sensorineural hearing loss: The Tubingen University experience
    • Zenner H.P., Leysieffer H. Total implantation of the Implex TICA hearing amplifier implant for high frequency sensorineural hearing loss. the Tubingen University experience Otolaryngol. Clin. North Am. 34(2):2001;417-446.
    • (2001) Otolaryngol. Clin. North Am. , vol.34 , Issue.2 , pp. 417-446
    • Zenner, H.P.1    Leysieffer, H.2
  • 5
    • 0036064206 scopus 로고    scopus 로고
    • Functional gain of already implanted hearing devices in patients with sensorineural hearin loss of varied origin end extent: Berlin experience
    • Junker R., Gross M., Todt I., Ernst A. Functional gain of already implanted hearing devices in patients with sensorineural hearin loss of varied origin end extent. Berlin experience Otol. Neurolotol. 23:2002;452-456.
    • (2002) Otol. Neurolotol. , vol.23 , pp. 452-456
    • Junker, R.1    Gross, M.2    Todt, I.3    Ernst, A.4
  • 6
    • 0028938696 scopus 로고
    • Engineering principles of mechanical stimulation of the middle ear
    • Ko W.H., Zhu W.L., Maniglia A.J. Engineering principles of mechanical stimulation of the middle ear. Otolaryngol. Clin. North Am. 28(1):1995;29-41.
    • (1995) Otolaryngol. Clin. North Am. , vol.28 , Issue.1 , pp. 29-41
    • Ko, W.H.1    Zhu, W.L.2    Maniglia, A.J.3
  • 12
    • 0028342674 scopus 로고
    • Experimental study of the acoustic properties of incus replacement prostheses in a human temporal bone model
    • Nishihara S., Goode R.L. Experimental study of the acoustic properties of incus replacement prostheses in a human temporal bone model. Am. J. Otol. 15(4):1994;485-494.
    • (1994) Am. J. Otol. , vol.15 , Issue.4 , pp. 485-494
    • Nishihara, S.1    Goode, R.L.2
  • 13
    • 0033989333 scopus 로고    scopus 로고
    • The effect of the "floating mass transducer" in the middle ear on hearing sensitivity
    • Snik F.M., Cremers W.R. The effect of the "floating mass transducer" in the middle ear on hearing sensitivity. Am. J. Otol. 21(1):2000;42-48.
    • (2000) Am. J. Otol. , vol.21 , Issue.1 , pp. 42-48
    • Snik, F.M.1    Cremers, W.R.2
  • 18
    • 0031243371 scopus 로고    scopus 로고
    • Ein implantierbarer piezoelektrischer Hörgerätewandler für Innenohrschwerhörige, Teil II: Klinisches Implantat
    • H. Leysieffer, J.W. Baumann , G. Müller, H.P. Zenner, Ein implantierbarer piezoelektrischer Hörgerätewandler für Innenohrschwerhörige, Teil II: Klinisches Implantat, HNO 45 (1997) 801-815.
    • (1997) HNO , vol.45 , pp. 801-815
    • Leysieffer, H.1    Baumann, J.W.2    Müller, G.3    Zenner, H.P.4