메뉴 건너뛰기




Volumn 34, Issue 2, 2001, Pages 417-446

Total implantation of the implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss: The Tübingen University experience

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; BIOCOMPATIBILITY; CLINICAL ARTICLE; DISEASE SEVERITY; DYNAMICS; GERMANY; HEARING AID; HUMAN; IMPEDANCE; IMPLANTATION; MASTOID; NONHUMAN; PATIENT SELECTION; PERCEPTION DEAFNESS; PERFORMANCE; REVIEW; SENSOR; SOUND PRESSURE; TEMPORAL BONE; TREATMENT INDICATION; X RAY FILM;

EID: 0034993012     PISSN: 00306665     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0030-6665(05)70340-6     Document Type: Article
Times cited : (57)

References (56)
  • 2
    • 0031911346 scopus 로고    scopus 로고
    • Basics of energy supply to completely implantable hearing aids for sensorineural hearing loss
    • (1998) HNO , vol.46 , pp. 121-128
    • Baumann, J.W.1    Leysieffer, H.2
  • 26
    • 0031243648 scopus 로고    scopus 로고
    • Adaption of the geometry of implantable hearing aid components to the human temporal bone. 1: Electromechanical transducer
    • (1997) HNO , vol.45 , pp. 840-846
    • Maassen, M.M.1    Lehner, R.L.2    Müller, G.3
  • 28
    • 0032018929 scopus 로고    scopus 로고
    • Preoperative assessment of implantable cochlea amplifiers using conventional X-ray and CT scans of the temporal bone
    • (1998) HNO , vol.46 , pp. 220-227
    • Maassen, M.M.1    Lehner, R.2    Dammann, F.3
  • 33
    • 0002783176 scopus 로고
    • Magnetic audition-auditory stimulation by means of alternating magnetic fields acting on a permanent magnet fixed to the eardrum
    • (1959) IRE Trans Med Electronics , vol.6 , pp. 22-23
    • Rutschmann, J.1
  • 36
    • 0032759926 scopus 로고    scopus 로고
    • First audiometric results with the Vibrant Soundbridge, a semi- implantable hearing device for sensorineural hearing loss
    • (1999) Audiology , vol.38 , pp. 335-338
    • Snik, A.F.1    Cremers, C.W.2
  • 44
    • 0024411528 scopus 로고
    • Further clinical experiences with middle ear implantable hearing aids: Indicatings and sound quality evaluation
    • (1989) ORL , vol.51 , pp. 229-234
    • Suzuki, J.1    Kodera, K.2    Suzuki, M.3
  • 48
    • 84973991447 scopus 로고
    • Eine methode zur bestimmung der hörschwellenamplituden des trommelfells bei verschiedenen frequenzen
    • (1935) Scand Arch Physiol , vol.72 , pp. 161-165
    • Wilska, A.1
  • 53
    • 0031242042 scopus 로고    scopus 로고
    • An implantable hearing aid for sensorineural hearing loss: First implantation of microphone and transducer in patients
    • (1997) HNO , vol.45 , pp. 872-880
    • Zenner, H.P.1    Maassen, M.M.2    Lehner, R.3
  • 54
    • 0031241187 scopus 로고    scopus 로고
    • Active electronic hearing implants for patients with conductive and sensorineural hearing loss-a new ear in ear surgery. 1: Basic principles and suggested nomenclature
    • (1997) HNO , vol.45 , pp. 749-757
    • Zenner, H.P.1    Leysieffer, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.