메뉴 건너뛰기




Volumn 26 III, Issue , 2004, Pages 1914-1917

Real time high spatial-temporal resolution flow imaging with spiral mri using auto-calibrated SENSE

Author keywords

Phase contrast; Real time mri; SENSE; Spiral

Indexed keywords

PHASE CONTRAST; REAL-TIME MRI; SENSE; SPIRAL;

EID: 11144351087     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (16)
  • 2
    • 0028287176 scopus 로고
    • Real time blood flow imaging by spiral scan phase velocity mapping
    • P.D. Gatehouse, D.N. Firmin, S. Collins, and D.B. Longmore, "Real time blood flow imaging by spiral scan phase velocity mapping," Magn. Reson. Med., vol. 31, no. 5, pp. 504-512, 1994.
    • (1994) Magn. Reson. Med. , vol.31 , Issue.5 , pp. 504-512
    • Gatehouse, P.D.1    Firmin, D.N.2    Collins, S.3    Longmore, D.B.4
  • 3
    • 0344305574 scopus 로고    scopus 로고
    • Real-time volumetric flow measurements with complex-difference MRI
    • R.B. Thompson and E.R. McVeigh, "Real-time volumetric flow measurements with complex-difference MRI," Magn. Reson.Med., vol. 50, no. 6, pp. 1248-1255, 2003.
    • (2003) Magn. Reson.Med. , vol.50 , Issue.6 , pp. 1248-1255
    • Thompson, R.B.1    McVeigh, E.R.2
  • 5
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • D.K. Sodickson and W.I. Manning, "Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays," Magn. Reson. Med., vol. 38, no. 4, pp. 591-603, 1997.
    • (1997) Magn. Reson. Med. , vol.38 , Issue.4 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.I.2
  • 7
    • 0242322611 scopus 로고    scopus 로고
    • Accuracy and reproducibility in phase contrast imaging using SENSE
    • P. Thunberg, M. Karlsson, and L. Wigstrom, "Accuracy and reproducibility in phase contrast imaging using SENSE," Magn Reson. Med., vol. 50, no. 5, pp. 1061-1068, 2003.
    • (2003) Magn Reson. Med. , vol.50 , Issue.5 , pp. 1061-1068
    • Thunberg, P.1    Karlsson, M.2    Wigstrom, L.3
  • 8
    • 0011375894 scopus 로고    scopus 로고
    • Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories
    • F.T.A.W Wajer and K.P Pruessmann, "Major speedup of reconstruction for sensitivity encoding with arbitrary trajectories," Proc. Intl. Soc. Mag. Reson. Med, vol. 9, pp. 767, 2001.
    • (2001) Proc. Intl. Soc. Mag. Reson. Med , vol.9 , pp. 767
    • Wajer, F.T.A.W.1    Pruessmann, K.P.2
  • 10
    • 0026219520 scopus 로고
    • Selection of convolution function for fourier inversion using gridding
    • J.I. Jackson, Mayer C.H, D. Nishimura, and A. Macovski, "Selection of convolution function for fourier inversion using gridding," IEEE Trans. Med. Imaging, vol. 10, no. 3, pp. 473-178, 1001.
    • (1001) IEEE Trans. Med. Imaging , vol.10 , Issue.3 , pp. 473-1178
    • Jackson, J.I.1    Mayer, C.H.2    Nishimura, D.3    Macovski, A.4
  • 11
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • P. Kellman, F.H. Epstein, and E.R. McVeigh, "Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)," Magn. Reson. Med., vol. 45, no. 5, pp. 846-852, 2001.
    • (2001) Magn. Reson. Med. , vol.45 , Issue.5 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 12
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • B. Madore, G.H. Glover, and N.J. Pelc, "Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI," Magn. Reson. Med., vol. 42, no. 5, pp. 813-828, 1999.
    • (1999) Magn. Reson. Med. , vol.42 , Issue.5 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 13
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • D.O. Walsh, A.F. Gmitro, and M.W. Marcellin, "Adaptive reconstruction of phased array MR imagery," Magn. Reson. Med., vol. 43, no. 5, pp. 682-690, 2000.
    • (2000) Magn. Reson. Med. , vol.43 , Issue.5 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 14
    • 0026912776 scopus 로고
    • Minimizing TE in moment-nulled or flow-encoded two- And three-dimensional gradientecho imaging
    • M.A. Bernstein, A. Shimakawa, and N.J. Pelc, "Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradientecho imaging," J.Magn. Reson. Imaging, vol. 2, no. 5, pp. 583-588, 1992.
    • (1992) J.Magn. Reson. Imaging , vol.2 , Issue.5 , pp. 583-588
    • Bernstein, M.A.1    Shimakawa, A.2    Pelc, N.J.3
  • 16
    • 0025126149 scopus 로고
    • Simultaneous spatial and spectral selective excitation
    • C.H. Meyer, J.M. Pauly, A. Macovski, and D.G. Nishimura, "Simultaneous spatial and spectral selective excitation," Magn. Reson. Med., vol. 15, no. 2. pp. 287-304, 1990.
    • (1990) Magn. Reson. Med. , vol.15 , Issue.2 , pp. 287-304
    • Meyer, C.H.1    Pauly, J.M.2    Macovski, A.3    Nishimura, D.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.