메뉴 건너뛰기




Volumn 115, Issue 3, 2005, Pages 239-244

Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer

Author keywords

Blood collection tube; INR; Magnesium; Prothrombin time; Thromboplastin

Indexed keywords

CITRATE SODIUM; MAGNESIUM; RECOMBINANT THROMBOPLASTIN;

EID: 11144284730     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.thromres.2004.08.019     Document Type: Article
Times cited : (11)

References (9)
  • 1
    • 0025289048 scopus 로고
    • The dependence of the international sensitivity index on the coagulometer used to perform the prothrombin time
    • M.J. Ray, and I.R. Smith The dependence of the international sensitivity index on the coagulometer used to perform the prothrombin time Thromb. Haemost. 63 1990 424 429
    • (1990) Thromb. Haemost. , vol.63 , pp. 424-429
    • Ray, M.J.1    Smith, I.R.2
  • 2
    • 0031851147 scopus 로고    scopus 로고
    • Assessment of the influence of citrate concentration on the international normalized ratio (INR) determined with twelve reagent-instrument combinations
    • V. Chantarangkul, A. Tripodi, M. Clerici, B. Negri, and P.M. Mannucci Assessment of the influence of citrate concentration on the international normalized ratio (INR) determined with twelve reagent-instrument combinations Thromb. Haemost. 80 1998 258 262
    • (1998) Thromb. Haemost. , vol.80 , pp. 258-262
    • Chantarangkul, V.1    Tripodi, A.2    Clerici, M.3    Negri, B.4    Mannucci, P.M.5
  • 3
    • 0035067666 scopus 로고    scopus 로고
    • Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes
    • A.M.H.P. Van den Besselaar, W. van Dam, A. Sturk, and R.M. Bertina Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes Thromb. Haemost. 85 2001 647 650
    • (2001) Thromb. Haemost. , vol.85 , pp. 647-650
    • Van Den Besselaar, A.M.H.P.1    Van Dam, W.2    Sturk, A.3    Bertina, R.M.4
  • 4
    • 0037247689 scopus 로고    scopus 로고
    • The influence of exogenous magnesium chloride on the apparent INR determined with human, rabbit, and bovine thromboplastin reagents
    • A.M.H.P. Van den Besselaar, E. Witteveen, J. Meeuwisse-Braun, and F.J.M. van der Meer The influence of exogenous magnesium chloride on the apparent INR determined with human, rabbit, and bovine thromboplastin reagents Thromb. Haemost. 89 2003 43 47
    • (2003) Thromb. Haemost. , vol.89 , pp. 43-47
    • Van Den Besselaar, A.M.H.P.1    Witteveen, E.2    Meeuwisse-Braun, J.3    Van Der Meer, F.J.M.4
  • 5
    • 0003940062 scopus 로고    scopus 로고
    • Guidelines for thromboplastins and plasma used to control oral anticoagulant therapy
    • WHO Expert Committee on Biological Standardization Guidelines for thromboplastins and plasma used to control oral anticoagulant therapy WHO Techn. Rep. 889 1999 64 93
    • (1999) WHO Techn. Rep. , vol.889 , pp. 64-93
  • 6
    • 0031936408 scopus 로고    scopus 로고
    • International collaborative study for the calibration of a proposed reference preparation for thromboplastin, human recombinant, plain. on behalf of the Subcommittee on Control of Anticoagulation
    • A. Tripodi, V. Chantarangkul, B. Negri, M. Clerici, and P.M. Mannucci International collaborative study for the calibration of a proposed reference preparation for thromboplastin, human recombinant, plain. On behalf of the Subcommittee on Control of Anticoagulation Thromb. Haemost. 79 1998 439 443
    • (1998) Thromb. Haemost. , vol.79 , pp. 439-443
    • Tripodi, A.1    Chantarangkul, V.2    Negri, B.3    Clerici, M.4    Mannucci, P.M.5
  • 7
    • 0024377122 scopus 로고
    • The effect of some instruments for prothrombin time testing on the International Sensitivity Index (ISI) of two rabbit tissue thromboplastin reagents
    • M. Poggio, A.M.H.P. van den Besselaar, E.A. van der Velde, and R.M. Bertina The effect of some instruments for prothrombin time testing on the International Sensitivity Index (ISI) of two rabbit tissue thromboplastin reagents Thromb. Haemost. 62 1989 868 874
    • (1989) Thromb. Haemost. , vol.62 , pp. 868-874
    • Poggio, M.1    Van Den Besselaar, A.M.H.P.2    Van Der Velde, E.A.3    Bertina, R.M.4
  • 8
    • 0034897663 scopus 로고    scopus 로고
    • The clinical relevance of the citrate effect on International Normalized Ratio determinations depends on the reagent and instrument combination used
    • L. Lottin, B.J. Woodhams, M.C. Saureau, A. Robert, M.F. Aillaud, and E. Arnaud The clinical relevance of the citrate effect on International Normalized Ratio determinations depends on the reagent and instrument combination used Blood Coagul. Fibrinolysis 12 2001 399 404
    • (2001) Blood Coagul. Fibrinolysis , vol.12 , pp. 399-404
    • Lottin, L.1    Woodhams, B.J.2    Saureau, M.C.3    Robert, A.4    Aillaud, M.F.5    Arnaud, E.6
  • 9
    • 0033782634 scopus 로고    scopus 로고
    • A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination
    • A.M.H.P. Van den Besselaar, V. Chantarangkul, and A. Tripodi A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination Thromb. Haemost. 84 2000 664 667
    • (2000) Thromb. Haemost. , vol.84 , pp. 664-667
    • Van Den Besselaar, A.M.H.P.1    Chantarangkul, V.2    Tripodi, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.