메뉴 건너뛰기




Volumn 26, Issue 1, 2004, Pages 58-66

Breakthroughs in Radiography: Computed Radiography

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0742323663     PISSN: 01931903     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (16)

References (18)
  • 3
    • 0035430459 scopus 로고    scopus 로고
    • Digital x-ray systems, Part 1: Health devices; An introduction to DX technologies and an evaluation of cassette DX systems
    • Launders J: Digital x-ray systems, Part 1: Health devices; An introduction to DX technologies and an evaluation of cassette DX systems. Health Devices 30(8):273-310, 2001.
    • (2001) Health Devices , vol.30 , Issue.8 , pp. 273-310
    • Launders, J.1
  • 4
    • 84862039735 scopus 로고    scopus 로고
    • accessed November 2003
    • Fujifilm: CR vs. DR. Available at http://www.fujimed.com/medical/crvsdr.html; accessed November 2003.
    • CR vs. DR
  • 5
    • 84862036861 scopus 로고    scopus 로고
    • accessed November 2003
    • IDEXX Laboratories: Enhance Your Patient's Image. Available at http://www.idexx.com/AnimalHealth/Digital/index.cfm; accessed November 2003.
    • Enhance Your Patient's Image
  • 7
    • 84862036417 scopus 로고    scopus 로고
    • accessed November 2003
    • All Pets Dental: Why Radiology? Available at http://www.dentalvet.com/vets/basicdentistry/whywhenliow_radiology.htm; accessed November 2003.
    • Why Radiology?
  • 8
    • 84862030884 scopus 로고    scopus 로고
    • accessed November 2003
    • Fujifilm: Basic CR Theory. Available at http://www.fujimed.com/medical/cr_basics.html; accessed November 2003.
    • Basic CR Theory
  • 10
    • 0031033942 scopus 로고    scopus 로고
    • Screen-film versus computed radiography imaging of the hand: A direct comparison
    • Swee RG, Gray JE, Beabout JW, et al: Screen-film versus computed radiography imaging of the hand: A direct comparison. Am J Roentgenol 168(2):539-542, 1997.
    • (1997) Am J Roentgenol , vol.168 , Issue.2 , pp. 539-542
    • Swee, R.G.1    Gray, J.E.2    Beabout, J.W.3
  • 11
    • 0032738191 scopus 로고    scopus 로고
    • Computed radiography versus screen-film radiography: Detection of pulmonary edema in a rabbit model that stimulates neonatal pulmonary infiltrates
    • Don S, Hildebolt CF, Sharp TL, et al: Computed radiography versus screen-film radiography: Detection of pulmonary edema in a rabbit model that stimulates neonatal pulmonary infiltrates. Radiology 213:455-460, 1999.
    • (1999) Radiology , vol.213 , pp. 455-460
    • Don, S.1    Hildebolt, C.F.2    Sharp, T.L.3
  • 12
    • 0029977636 scopus 로고    scopus 로고
    • Evaluation of soft-tissue foreign bodies: Comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer work-station
    • Reiner B, Siegel E, McLaurin T, et al: Evaluation of soft-tissue foreign bodies: Comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer work-station. Am J Roentgenol 167(1):141-44, 1996.
    • (1996) Am J Roentgenol , vol.167 , Issue.1 , pp. 141-144
    • Reiner, B.1    Siegel, E.2    McLaurin, T.3
  • 13
    • 0025275562 scopus 로고
    • Comparison of digital and conventional musculoskeletal radiography: An observer performance study
    • Wegryn SA, Piraino DW, Richmond BJ, et al: Comparison of digital and conventional musculoskeletal radiography: An observer performance study. Radiology 175(1):225-228, 1990.
    • (1990) Radiology , vol.175 , Issue.1 , pp. 225-228
    • Wegryn, S.A.1    Piraino, D.W.2    Richmond, B.J.3
  • 15
    • 84862040243 scopus 로고    scopus 로고
    • accessed November 2003
    • Fujifilm: Advanced Processing Capabilities of FCR. Available at http://www.fujimed.com/medical/cr_process5.html; accessed November 2003.
    • Advanced Processing Capabilities of FCR
  • 16
    • 0025344055 scopus 로고
    • Nondisplaced fractures: Spatial resolution requirements for detection with digital skeletal imaging
    • Murphey MD, Bramble JM, Cook LT, et al: Nondisplaced fractures: Spatial resolution requirements for detection with digital skeletal imaging. Radiology 174(3 Pt 1):865-870, 1990.
    • (1990) Radiology , vol.174 , Issue.3 PART 1 , pp. 865-870
    • Murphey, M.D.1    Bramble, J.M.2    Cook, L.T.3
  • 17
    • 0031204597 scopus 로고    scopus 로고
    • Comparison of conventional and computed radiography: Assessment of image quality and reader performance in skeletal extremity trauma
    • Lund PJ, Krupinski EA, Pereles S, Mockbee B: Comparison of conventional and computed radiography: Assessment of image quality and reader performance in skeletal extremity trauma. Acad Radiol 4(8):570-576, 1997.
    • (1997) Acad Radiol , vol.4 , Issue.8 , pp. 570-576
    • Lund, P.J.1    Krupinski, E.A.2    Pereles, S.3    Mockbee, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.