메뉴 건너뛰기




Volumn 11, Issue 5, 1997, Pages 595-598

The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning

Author keywords

DLT movement; Double lumen endobronchial tube; Fiberoptic bronchoscopy; Thoracic anesthesia

Indexed keywords

ADULT; ANESTHESIA COMPLICATION; ARTICLE; BODY POSITION; BRONCHUS; CLINICAL ARTICLE; CLINICAL TRIAL; ENDOBRONCHIAL INTUBATION; ENDOTRACHEAL CUFF; FIBEROPTIC BRONCHOSCOPY; HUMAN; PRIORITY JOURNAL;

EID: 0030843302     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(97)90011-2     Document Type: Article
Times cited : (61)

References (13)
  • 1
    • 0027422263 scopus 로고
    • A quality improvement study of the placement and complications of double-lumen endobronchial tubes
    • Hurford WE, Alfille PH: A quality improvement study of the placement and complications of double-lumen endobronchial tubes. J Cardiothoracic Vasc Anesth 7:517-520, 1993
    • (1993) J Cardiothoracic Vasc Anesth , vol.7 , pp. 517-520
    • Hurford, W.E.1    Alfille, P.H.2
  • 3
    • 0027081047 scopus 로고
    • The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures
    • Lewis JW, Sherwin JP, Gabriel PS, et al: The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures. J Cardiothoracic Vasc Anesth 6:705-710, 1992
    • (1992) J Cardiothoracic Vasc Anesth , vol.6 , pp. 705-710
    • Lewis, J.W.1    Sherwin, J.P.2    Gabriel, P.S.3
  • 4
    • 0024261792 scopus 로고
    • Pro: Proper positioning of a double-lumen endobronchial tube can only be accomplished with endoscopy
    • Ehrenwerth J: Pro: Proper positioning of a double-lumen endobronchial tube can only be accomplished with endoscopy. J Cardiothqrac Vasc Anesth 2:101-104, 1988
    • (1988) J Cardiothqrac Vasc Anesth , vol.2 , pp. 101-104
    • Ehrenwerth, J.1
  • 5
    • 0024273853 scopus 로고
    • Con: Proper positioning of a double-lumen endobronchial tube can only be accomplished with the use of endoscopy
    • Brodsky JB: Con: Proper positioning of a double-lumen endobronchial tube can only be accomplished with the use of endoscopy. J Cardiothorac Vasc Anesth 2:105-109, 1988
    • (1988) J Cardiothorac Vasc Anesth , vol.2 , pp. 105-109
    • Brodsky, J.B.1
  • 6
    • 0028911005 scopus 로고
    • Incidence of malposition of polyvinylchloride and red rubber left-sided double lumen tubes and clinical sequelae
    • Cohen E, Neustein SM, Goldofsky S, Camunas JL: Incidence of malposition of polyvinylchloride and red rubber left-sided double lumen tubes and clinical sequelae. J Cardiothorac Vasc Anesth 9:122-127, 1995
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 122-127
    • Cohen, E.1    Neustein, S.M.2    Goldofsky, S.3    Camunas, J.L.4
  • 7
    • 0022069485 scopus 로고
    • Alteration of double-lumen endobronchial tube position by flexion and extension of the neck
    • Saito S, Dohl S, Naito H: Alteration of double-lumen endobronchial tube position by flexion and extension of the neck. Anesthesiology 62:696-697, 1985
    • (1985) Anesthesiology , vol.62 , pp. 696-697
    • Saito, S.1    Dohl, S.2    Naito, H.3
  • 8
    • 0016873506 scopus 로고
    • Alteration of endotracheal tube position, flexion and extension of the neck
    • Conrardy PA, Goodman LR, Lainge F, Singer MM: Alteration of endotracheal tube position, flexion and extension of the neck. Grit Care Med 4:8-12, 1976
    • (1976) Grit Care Med , vol.4 , pp. 8-12
    • Conrardy, P.A.1    Goodman, L.R.2    Lainge, F.3    Singer, M.M.4
  • 9
    • 0030020837 scopus 로고    scopus 로고
    • Displacement of the endotracheal tube caused by change of head position in pediatric anesthesia: Evaluation by fiberoptic bronchoscopy
    • Sugiyama K, Yokoyama K: Displacement of the endotracheal tube caused by change of head position in pediatric anesthesia: Evaluation by fiberoptic bronchoscopy. Anesth Analg 82:251-253, 1996
    • (1996) Anesth Analg , vol.82 , pp. 251-253
    • Sugiyama, K.1    Yokoyama, K.2
  • 10
    • 0026481037 scopus 로고
    • Relocation of a double-lumen tube during patient positioning
    • Riley RH, Marples IL: Relocation of a double-lumen tube during patient positioning. Anesth Analg 75:1071, 1992
    • (1992) Anesth Analg , vol.75 , pp. 1071
    • Riley, R.H.1    Marples, I.L.2
  • 12
    • 0021958079 scopus 로고
    • Malposition of left-sided double lumen endobronchial tubes
    • Brodsky JB, Shulman MS, Mark JBD: Malposition of left-sided double lumen endobronchial tubes. Anesthesiology 62:667-669, 1985
    • (1985) Anesthesiology , vol.62 , pp. 667-669
    • Brodsky, J.B.1    Shulman, M.S.2    Mark, J.B.D.3
  • 13
    • 12644258320 scopus 로고
    • Respiratory system
    • Clemente C (ed): Philadelphia, PA, Lea & Febriger
    • Gray H: Respiratory system, in Clemente C (ed): Anatomy of the Human Body (ed 13). Philadelphia, PA, Lea & Febriger, 1985, pp 1380-1398
    • (1985) Anatomy of the Human Body (Ed 13) , pp. 1380-1398
    • Gray, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.