-
1
-
-
0022892595
-
The utilization of two frequency-shifted sinc pulses for performing volume-selected in vivo NMR spectroscopy
-
Doddrell DD, Galloway GJ, Brooks WM, Bulsing JM, Field JC, Irving MG, Baddeley H. The utilization of two frequency-shifted sinc pulses for performing volume-selected in vivo NMR spectroscopy. Magn Reson Med 1986;3:970-975.
-
(1986)
Magn Reson Med
, vol.3
, pp. 970-975
-
-
Doddrell, D.D.1
Galloway, G.J.2
Brooks, W.M.3
Bulsing, J.M.4
Field, J.C.5
Irving, M.G.6
Baddeley, H.7
-
2
-
-
0027247645
-
Multisection proton MR spectroscopic imaging of the brain
-
Duyn JH, Gillen J, Sobering G, van Zijl PC, Moonen CT. Multisection proton MR spectroscopic imaging of the brain. Radiology 1993;188:277-282.
-
(1993)
Radiology
, vol.188
, pp. 277-282
-
-
Duyn, J.H.1
Gillen, J.2
Sobering, G.3
Van Zijl, P.C.4
Moonen, C.T.5
-
3
-
-
0022878526
-
Localization of unaffected spins in NMR imaging and spectroscopy (LOCUS spectroscopy)
-
Haase A. Localization of unaffected spins in NMR imaging and spectroscopy (LOCUS spectroscopy). Magn Reson Med 1986;3:963-969.
-
(1986)
Magn Reson Med
, vol.3
, pp. 963-969
-
-
Haase, A.1
-
4
-
-
0342288256
-
Stored waveform inverse Fourier-Transform (SWIFT) excitation for water-suppressed whole-body slice-selected proton chemical shift spectra at 1.5 Tesla
-
Hsu AT, Hunter WW, Schmalbrock P, Marshall AG. Stored waveform inverse Fourier-Transform (SWIFT) excitation for water-suppressed whole-body slice-selected proton chemical shift spectra at 1.5 Tesla. J Magn Reson 1987;72:75-88.
-
(1987)
J Magn Reson
, vol.72
, pp. 75-88
-
-
Hsu, A.T.1
Hunter, W.W.2
Schmalbrock, P.3
Marshall, A.G.4
-
5
-
-
0343157845
-
Space-selective saturation by frequency modulated pulses
-
San Francisco
-
Klose U. Space-selective saturation by frequency modulated pulses. In: Proc SMR, San Francisco, 1998, vol. 2. p 1059.
-
(1998)
Proc SMR
, vol.2
, pp. 1059
-
-
Klose, U.1
-
6
-
-
0022598272
-
Use of frequency-modulated radio frequency pulses in MR imaging experiments
-
Kunz D. Use of frequency-modulated radio frequency pulses in MR imaging experiments. Magn Reson Med 1986;3:377-384.
-
(1986)
Magn Reson Med
, vol.3
, pp. 377-384
-
-
Kunz, D.1
-
7
-
-
0001653248
-
Projection presaturation: A fast and accurate technique for multidimensional spatial localization
-
Singh S, Rutt BK, Henkelman RM. Projection presaturation: a fast and accurate technique for multidimensional spatial localization. J Magn Reson 1990;87:567-583.
-
(1990)
J Magn Reson
, vol.87
, pp. 567-583
-
-
Singh, S.1
Rutt, B.K.2
Henkelman, R.M.3
-
8
-
-
0028086141
-
Band-selective spin echoes for in vivo localized /sup 1/H NMR spectroscopy
-
Shungu DC, Glickson JD. Band-selective spin echoes for in vivo localized /sup 1/H NMR spectroscopy. Magn Reson Med 1994;32:277-284.
-
(1994)
Magn Reson Med
, vol.32
, pp. 277-284
-
-
Shungu, D.C.1
Glickson, J.D.2
-
9
-
-
0001221517
-
Projection presaturation. II. Single-shot localization of multiple regions of interest
-
Singh S, Rutt BK, Napel S. Projection presaturation. II. Single-shot localization of multiple regions of interest. J Magn Reson 1990;90:313-329.
-
(1990)
J Magn Reson
, vol.90
, pp. 313-329
-
-
Singh, S.1
Rutt, B.K.2
Napel, S.3
-
10
-
-
0027439537
-
Short echo time proton MR spectroscopic imaging
-
Posse S, Schuknecht B, Smith ME, van Zijl PCM, Herschkowitz N, Moonen TW. Short echo time proton MR spectroscopic imaging. J Comput Assist Tomogr 1993;17:1-14.
-
(1993)
J Comput Assist Tomogr
, vol.17
, pp. 1-14
-
-
Posse, S.1
Schuknecht, B.2
Smith, M.E.3
Van Zijl, P.C.M.4
Herschkowitz, N.5
Moonen, T.W.6
-
11
-
-
0343593327
-
-
Sydney, Australia
-
Schirmer T, Jones R, Hurd R, Sailasuta N, Tropp J, Le Roux P. In: Proc ISMRM, Sydney, Australia, 1998, vol. 3. p 1877.
-
(1998)
Proc ISMRM
, vol.3
, pp. 1877
-
-
Schirmer, T.1
Jones, R.2
Hurd, R.3
Sailasuta, N.4
Tropp, J.5
Le Roux, P.6
-
12
-
-
0023121544
-
Frequency-modulated radio frequency pulses in spin-echo and stimulated-echo experiments
-
Kunz D. Frequency-modulated radio frequency pulses in spin-echo and stimulated-echo experiments. Magn Reson Med 1987;4:129-136.
-
(1987)
Magn Reson Med
, vol.4
, pp. 129-136
-
-
Kunz, D.1
-
13
-
-
0031758092
-
Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging
-
Le Roux P, Gilles RJ, McKinnon GC, Carlier PG. Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging. J Magn Reson Imaging 1998;8:1022-1032.
-
(1998)
J Magn Reson Imaging
, vol.8
, pp. 1022-1032
-
-
Le Roux, P.1
Gilles, R.J.2
McKinnon, G.C.3
Carlier, P.G.4
-
14
-
-
0342288252
-
Selective excitation pulses requiring less peak power
-
New York
-
Shinnar M. Selective excitation pulses requiring less peak power. In: Proc SMR, New York, 1994. p 122.
-
(1994)
Proc SMR
, pp. 122
-
-
Shinnar, M.1
-
16
-
-
0000350824
-
Proton chemical shift imaging of cancer
-
Higgins CB, Hricak H, Helms CA, editors. New York: Raven Press
-
Vigneron D, Kurhanewicz J, Nelson S. Proton chemical shift imaging of cancer. In: Higgins CB, Hricak H, Helms CA, editors. Magnetic resonance imaging of the body. New York: Raven Press; 1997. p 205-220.
-
(1997)
Magnetic Resonance Imaging of the Body
, pp. 205-220
-
-
Vigneron, D.1
Kurhanewicz, J.2
Nelson, S.3
-
17
-
-
0031397833
-
Volume MRI and MRSI techniques for the quantitation of treatment response in brain tumors: Presentation of a detailed case study
-
Nelson SJ, Huhn S, Vigneron DB, Day MR, Wald LL, Prados M, Chang S, Gutin PH, Sneed PK, Verhey L, Hawkins RA, Dillon WP. Volume MRI and MRSI techniques for the quantitation of treatment response in brain tumors: presentation of a detailed case study. J Magn Reson Imaging 1997;7:1146-1152.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 1146-1152
-
-
Nelson, S.J.1
Huhn, S.2
Vigneron, D.B.3
Day, M.R.4
Wald, L.L.5
Prados, M.6
Chang, S.7
Gutin, P.H.8
Sneed, P.K.9
Verhey, L.10
Hawkins, R.A.11
Dillon, W.P.12
-
18
-
-
0030983951
-
Increased choline signal coinciding with malignant degeneration of cerebral gliomas: A serial proton magnetic resonance spectroscopy imaging study
-
Tedeschi G, Lundbom N, Raman R, Bonavita S, Duyn JH, Alger JR, Di Chiro G. Increased choline signal coinciding with malignant degeneration of cerebral gliomas: a serial proton magnetic resonance spectroscopy imaging study. J Neurosurg 1997;87:516-524.
-
(1997)
J Neurosurg
, vol.87
, pp. 516-524
-
-
Tedeschi, G.1
Lundbom, N.2
Raman, R.3
Bonavita, S.4
Duyn, J.H.5
Alger, J.R.6
Di Chiro, G.7
-
19
-
-
0030921701
-
Serial proton magnetic resonance spectroscopy imaging of glioblastoma multiforme after brachytherapy
-
Wald LL, Nelson SJ, Day MR, Noworolski SE, Henry RG, Huhn SL, Chang S, Prados MD, Sneed PK, Larson DA, Wara WM, McDermott M, Dillon WP, Gutin PH, Vigneron DB. Serial proton magnetic resonance spectroscopy imaging of glioblastoma multiforme after brachytherapy. J Neurosurg 1997;87:525-534.
-
(1997)
J Neurosurg
, vol.87
, pp. 525-534
-
-
Wald, L.L.1
Nelson, S.J.2
Day, M.R.3
Noworolski, S.E.4
Henry, R.G.5
Huhn, S.L.6
Chang, S.7
Prados, M.D.8
Sneed, P.K.9
Larson, D.A.10
Wara, W.M.11
McDermott, M.12
Dillon, W.P.13
Gutin, P.H.14
Vigneron, D.B.15
-
20
-
-
0028822816
-
Citrate as an in vivo marker to discriminate prostate cancer from benign prostatic hyperplasia and normal prostate peripheral zone: Detection via localized proton spectroscopy
-
Kurhanewicz J, Vigneron DB, Nelson SJ, Hricak H, MacDonald JM, Konety B, Narayan P. Citrate as an in vivo marker to discriminate prostate cancer from benign prostatic hyperplasia and normal prostate peripheral zone: detection via localized proton spectroscopy. Urology 1995;45:459-466.
-
(1995)
Urology
, vol.45
, pp. 459-466
-
-
Kurhanewicz, J.1
Vigneron, D.B.2
Nelson, S.J.3
Hricak, H.4
Macdonald, J.M.5
Konety, B.6
Narayan, P.7
-
21
-
-
0029890838
-
Prostate cancer: Metabolic response to cryosurgery as detected with 3D H-1 MR spectroscopic imaging
-
Kurhanewicz J, Vigneron DB, Hricak H, Parivar F, Nelson SJ, Shinohara K, Carroll PR. Prostate cancer: metabolic response to cryosurgery as detected with 3D H-1 MR spectroscopic imaging. Radiology 1996;200: 489-496.
-
(1996)
Radiology
, vol.200
, pp. 489-496
-
-
Kurhanewicz, J.1
Vigneron, D.B.2
Hricak, H.3
Parivar, F.4
Nelson, S.J.5
Shinohara, K.6
Carroll, P.R.7
-
22
-
-
0023636904
-
Spatial localization in NMR spectroscopy in vivo
-
Bottomley PA. Spatial localization in NMR spectroscopy in vivo. Ann N Y Acad Sci 1987;508:333-348.
-
(1987)
Ann N Y Acad Sci
, vol.508
, pp. 333-348
-
-
Bottomley, P.A.1
-
24
-
-
0028904155
-
Pulses with fixed magnitude and variable phase response profiles
-
Pickup S, Xiaoning D. Pulses with fixed magnitude and variable phase response profiles. Magn Reson Med 1995;33:648-855.
-
(1995)
Magn Reson Med
, vol.33
, pp. 648-855
-
-
Pickup, S.1
Xiaoning, D.2
-
25
-
-
0030854651
-
Improved water and lipid suppression for 3D PRESS CSI using RF band selective inversion with gradient dephasing BASING
-
Star-Lack J, Nelson SJ, Kurhanewicz J, Huang LR, Vigneron DB. Improved water and lipid suppression for 3D PRESS CSI using RF band selective inversion with gradient dephasing BASING. Magn Reson Med 1997;38:311-321.
-
(1997)
Magn Reson Med
, vol.38
, pp. 311-321
-
-
Star-Lack, J.1
Nelson, S.J.2
Kurhanewicz, J.3
Huang, L.R.4
Vigneron, D.B.5
-
26
-
-
0031422032
-
Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/ spatial spin-echo pulses
-
Star-Lack J, Vigneron DB, Pauly J, Kurhanewicz J, Nelson SJ. Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/ spatial spin-echo pulses. J Magn Reson Imaging 1997;7:745-757.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 745-757
-
-
Star-Lack, J.1
Vigneron, D.B.2
Pauly, J.3
Kurhanewicz, J.4
Nelson, S.J.5
-
28
-
-
0029265843
-
Surface coil MR imaging of the human brain with an analytic reception profile correction
-
Moyher SE, Vigneron DB, Nelson SJ. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging 1995;5:139-144.
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 139-144
-
-
Moyher, S.E.1
Vigneron, D.B.2
Nelson, S.J.3
-
29
-
-
0031397674
-
High resolution T2-weighted imaging of the human brain using surface coils and an analytical reception profile correction
-
Moyher SE, Wald LL, Nelson SJ, Hallam D, Dillon WP, Norman D, Vigneron DB. High resolution T2-weighted imaging of the human brain using surface coils and an analytical reception profile correction. J Magn Reson Imaging 1997;7:512-517.
-
(1997)
J Magn Reson Imaging
, vol.7
, pp. 512-517
-
-
Moyher, S.E.1
Wald, L.L.2
Nelson, S.J.3
Hallam, D.4
Dillon, W.P.5
Norman, D.6
Vigneron, D.B.7
-
31
-
-
0026116321
-
Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm NMR imaging
-
Pauly J, Le Roux P, Nishimura D, Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm NMR imaging. IEEE Trans Med Imaging USA 1991;10:53-65.
-
(1991)
IEEE Trans Med Imaging USA
, vol.10
, pp. 53-65
-
-
Pauly, J.1
Le Roux, P.2
Nishimura, D.3
Macovski, A.4
-
32
-
-
0343157837
-
Highly effective outer volume suppression for short TE spin echo spectroscopic imaging using echo dephasing
-
Philadelphia
-
Wiese S, Posse S. Highly effective outer volume suppression for short TE spin echo spectroscopic imaging using echo dephasing. In: Proc ISMRM, Philadelphia, 1999, vol. 1. p 680.
-
(1999)
Proc ISMRM
, vol.1
, pp. 680
-
-
Wiese, S.1
Posse, S.2
-
33
-
-
0028014341
-
Magnetization transfer affects the proton creatine/phosphocreatine signal intensity: In vivo demonstration in the rat brain
-
Dreher W, Norris DG, Leibfritz D. Magnetization transfer affects the proton creatine/phosphocreatine signal intensity: in vivo demonstration in the rat brain. Magn Reson Med 1994;31:81-84.
-
(1994)
Magn Reson Med
, vol.31
, pp. 81-84
-
-
Dreher, W.1
Norris, D.G.2
Leibfritz, D.3
-
34
-
-
0342723352
-
Magnetization transfer in water suppressed 1H NMR brain spectroscopy
-
Philadelphia
-
Knight-Scott J. Magnetization transfer in water suppressed 1H NMR brain spectroscopy. In: Proc ISMRM, 1999, Philadelphia, vol. 3. p 1567.
-
(1999)
Proc ISMRM
, vol.3
, pp. 1567
-
-
Knight-Scott, J.1
|