메뉴 건너뛰기




Volumn 18, Issue 2, 2003, Pages 191-200

Computer-Assisted Image-Guided Intramedullary Nailing of Femoral Shaft Fractures

Author keywords

Computer assisted orthopaedic surgery; Femur fracture; Image guided surgery; Intramedullary nailing

Indexed keywords

COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; FEMUR FRACTURE; FEMUR SHAFT FRACTURE; FLUOROSCOPY; FRACTURE FIXATION; FRACTURE TREATMENT; HUMAN; IMAGING SYSTEM; INTRAMEDULLARY NAILING; ORTHOPEDIC SURGERY; PREOPERATIVE EVALUATION; REVIEW; ROBOTICS; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING; VIRTUAL REALITY;

EID: 0345843364     PISSN: 08859698     EISSN: None     Source Type: Journal    
DOI: 10.1097/00013611-200306000-00008     Document Type: Review
Times cited : (19)

References (28)
  • 1
    • 0029142712 scopus 로고
    • Femoral shaft fractures treated by intramedullary nailing. A follow-up study focusing on problems related to the method
    • Braten M, Terjesen T, Rossvoll I. Femoral shaft fractures treated by intramedullary nailing. A follow-up study focusing on problems related to the method. Injury 1995;26:379-383.
    • (1995) Injury , vol.26 , pp. 379-383
    • Braten, M.1    Terjesen, T.2    Rossvoll, I.3
  • 2
    • 0142204075 scopus 로고    scopus 로고
    • Regular and special features-the rationales of interlocking nailing of the femur, tibia, and humerus
    • Brumback RJ. Regular and special features-the rationales of interlocking nailing of the femur, tibia, and humerus. Clin Orthop 1996;324:586-651.
    • (1996) Clin Orthop , vol.324 , pp. 586-651
    • Brumback, R.J.1
  • 3
    • 0032127740 scopus 로고    scopus 로고
    • Ionising radiation during internal fixation of extracapsular neck of femur fractures
    • Giannoudis PV, McGuigan J, Shaw DL. Ionising radiation during internal fixation of extracapsular neck of femur fractures. Injury 1998;29:469-472.
    • (1998) Injury , vol.29 , pp. 469-472
    • Giannoudis, P.V.1    McGuigan, J.2    Shaw, D.L.3
  • 4
    • 0032111192 scopus 로고    scopus 로고
    • Measuring anteversion in the femoral neck from routine radiographs
    • Hermann KL, Egund N. Measuring anteversion in the femoral neck from routine radiographs. Acta Radiol 1998;39:410-415.
    • (1998) Acta Radiol , vol.39 , pp. 410-415
    • Hermann, K.L.1    Egund, N.2
  • 5
    • 0034523472 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopy-based reduction of femoral fractures and an-tetorsion correction
    • Hofstetter R, Slomczykowski M, Krettek C, et al. Computer-assisted fluoroscopy-based reduction of femoral fractures and an-tetorsion correction. Comput Aided Surg 2000;5:311-325.
    • (2000) Comput Aided Surg , vol.5 , pp. 311-325
    • Hofstetter, R.1    Slomczykowski, M.2    Krettek, C.3
  • 6
    • 0032822724 scopus 로고    scopus 로고
    • Fluoroscopy as an imaging means for computer-assisted surgical navigation
    • Hofstetter R, Slomczykowski M, Sati L-P, et al. Fluoroscopy as an imaging means for computer-assisted surgical navigation. Comput Aided Surg 1999;4:65-78.
    • (1999) Comput Aided Surg , vol.4 , pp. 65-78
    • Hofstetter, R.1    Slomczykowski, M.2    Sati, L.-P.3
  • 7
    • 0035201508 scopus 로고    scopus 로고
    • Computer-assisted fracture reduction: Novel method for analysis of accuracy
    • Hüffner T, Pohlemann T, Tarte S, et al. Computer-assisted fracture reduction: novel method for analysis of accuracy. Comput Aided Surg 2001;5:153-159.
    • (2001) Comput Aided Surg , vol.5 , pp. 153-159
    • Hüffner, T.1    Pohlemann, T.2    Tarte, S.3
  • 8
    • 0032454883 scopus 로고    scopus 로고
    • FRACAS: A system for computer-aided image-guided long bone fracture surgery
    • Joskowicz L, Milgrom C, Simkin A, et al. FRACAS: a system for computer-aided image-guided long bone fracture surgery. Comput Aided Surg 1999;3:271-288.
    • (1999) Comput Aided Surg , vol.3 , pp. 271-288
    • Joskowicz, L.1    Milgrom, C.2    Simkin, A.3
  • 9
    • 0142235000 scopus 로고    scopus 로고
    • Fluoroscopy-based navigation in computer-aided ortho-paedic surgery
    • Isermann, et al., eds., Darmstadt, Germany: Elsevier
    • Joskowicz L. Fluoroscopy-based navigation in computer-aided ortho-paedic surgery. In: Isermann, et al., eds. Proceedings of the IFAC Conference on Mechatronic Systems, Darmstadt, Germany: Elsevier, 2000.
    • (2000) Proceedings of the IFAC Conference on Mechatronic Systems
    • Joskowicz, L.1
  • 11
    • 0345552149 scopus 로고    scopus 로고
    • Mechanical distal aiming device for distal locking in femoral nails
    • Krettek C, Konemann B, Miciau T, et al. Mechanical distal aiming device for distal locking in femoral nails. Clin Orthop 1999;384: 267-275.
    • (1999) Clin Orthop , vol.384 , pp. 267-275
    • Krettek, C.1    Konemann, B.2    Miciau, T.3
  • 12
    • 0036788370 scopus 로고    scopus 로고
    • Radiation exposure to surgeon and patient during intramedullary nailing of the lower limb
    • Madan S, Blakeway C. Radiation exposure to surgeon and patient during intramedullary nailing of the lower limb. Injury 2000;33: 723-727.
    • (2000) Injury , vol.33 , pp. 723-727
    • Madan, S.1    Blakeway, C.2
  • 13
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure, to the surgical team 'during fluoroscopy: How far away is far enough?'
    • Mehiman CT Di Pasquale TG. Radiation exposure, to the surgical team 'during fluoroscopy: how far away is far enough?' J Orthop Trauma 1997;11:392-398.
    • (1997) J Orthop Trauma , vol.11 , pp. 392-398
    • Mehiman, C.T.1    Di Pasquale, T.G.2
  • 14
    • 0032127086 scopus 로고    scopus 로고
    • Radiation to the hands and thyroid of the surgeon during intramedullary nailing
    • Muller LP, Suffner J, Wenda K, et al. Radiation to the hands and thyroid of the surgeon during intramedullary nailing. Injury 1998; 29:461-468.
    • (1998) Injury , vol.29 , pp. 461-468
    • Muller, L.P.1    Suffner, J.2    Wenda, K.3
  • 17
    • 0038371273 scopus 로고    scopus 로고
    • Computer-based periaxial rotation measurement for aligning fractured femur fragments from CT: A feasibility study
    • Ron O, Joskowicz L, Simkin A, et al. Computer-based periaxial rotation measurement for aligning fractured femur fragments from CT: a feasibility study. Comput Aided Surg 2002;7:332-341.
    • (2002) Comput Aided Surg , vol.7 , pp. 332-341
    • Ron, O.1    Joskowicz, L.2    Simkin, A.3
  • 18
    • 0142196069 scopus 로고    scopus 로고
    • Bone-mounted miniature robot for surgical procedures: Concept and clinical applications
    • to appear
    • Shoham M, Burman M, Zehavi E, et al. Bone-mounted miniature robot for surgical procedures: concept and clinical applications. IEEE Transactions on Robotics and Automation, to appear; 2003.
    • (2003) IEEE Transactions on Robotics and Automation
    • Shoham, M.1    Burman, M.2    Zehavi, E.3
  • 20
    • 0001687238 scopus 로고    scopus 로고
    • Fluoroscopy-based surgical navigation-concept and possible clinical applications
    • Nolte LP, Ganz R, ed. Bern: Hogrefe and Huber Publishers
    • Slomczykowski M, Hofstetter R, Strauss M, et al. Fluoroscopy-based surgical navigation-concept and possible clinical applications. In: Nolte LP, Ganz R, ed. Computer Assisted Orthopaedic Surgery. Bern: Hogrefe and Huber Publishers, 1999:206-217.
    • (1999) Computer Assisted Orthopaedic Surgery , pp. 206-217
    • Slomczykowski, M.1    Hofstetter, R.2    Strauss, M.3
  • 21
    • 0031669387 scopus 로고    scopus 로고
    • A comparison of alternative methods of measuring femoral anteversion
    • Sugano N, Noble P, Kamaric E. A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 1998;22:610-614.
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 610-614
    • Sugano, N.1    Noble, P.2    Kamaric, E.3
  • 22
    • 0034463546 scopus 로고    scopus 로고
    • Surgical navigation based on fluoroscopy: Clinical application for computer-assisted distal locking of intramedullary implants
    • Suhm N, Jacob AL, Nolte LP, et al. Surgical navigation based on fluoroscopy: clinical application for computer-assisted distal locking of intramedullary implants. Comput Aided Surg 2000;5:391-400.
    • (2000) Comput Aided Surg , vol.5 , pp. 391-400
    • Suhm, N.1    Jacob, A.L.2    Nolte, L.P.3
  • 24
    • 0034805228 scopus 로고    scopus 로고
    • A new distal targeting device for closed intramedullary nailing
    • Tyropoulos S, Garvanos C. A new distal targeting device for closed intramedullary nailing. Injury 2001;32:732-735.
    • (2001) Injury , vol.32 , pp. 732-735
    • Tyropoulos, S.1    Garvanos, C.2
  • 26
    • 0347100778 scopus 로고    scopus 로고
    • Fractures of the femoral diaphysis, including the subtrochanteric region
    • Rosemont, IL: American Academy of Orthopaedic Surgeons
    • Wolinsky PR. Fractures of the femoral diaphysis, including the subtrochanteric region. Orthopaedic Knowledge Update: Trauma 2. Rosemont, IL: American Academy of Orthopaedic Surgeons, 2000:133-146.
    • (2000) Orthopaedic Knowledge Update: Trauma 2 , pp. 133-146
    • Wolinsky, P.R.1
  • 27
    • 0032196949 scopus 로고    scopus 로고
    • Prevention of malrotation in femoral shaft fracture
    • Yang KH, Han DY, Jahng JS, et al. Prevention of malrotation in femoral shaft fracture. J Orthop Trauma 1998;12:558-562.
    • (1998) J Orthop Trauma , vol.12 , pp. 558-562
    • Yang, K.H.1    Han, D.Y.2    Jahng, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.