-
3
-
-
0030033440
-
Regular and special features - The ra- tionales of interlocking nailing of the femur, tibia, and humerus
-
Brumback RJ. Regular and special features - the ra- tionales of interlocking nailing of the femur, tibia, and humerus. Clin Orthop Rel Res 324:292-320.
-
Clin Orthop Rel Res
, vol.324
, pp. 292-320
-
-
Brumback, R.J.1
-
4
-
-
84947727831
-
Treatment of pelvic ring fractures: Percutaneous computer-assisted illiosacral screwing
-
Wells S et al., editors. Proceedings of the 1st International Conference on Medical Computing and Computer-Assisted Intervention. New York: Elsevier
-
Carrat L, Tonetti J, Lavallée S, Merloz P, Pittet L, Chirossel JP. Treatment of pelvic ring fractures: Percutaneous computer-assisted illiosacral screwing. In: Wells S et al., editors. Proceedings of the 1st International Conference on Medical Computing and Computer-Assisted Intervention. Lecture Notes in Com puter Science Vol. 1496. New York: Elsevier; 1998. p 84-91.
-
(1998)
Lecture Notes in Com Puter Science
, vol.1496
, pp. 84-91
-
-
Carrat, L.1
Tonetti, J.2
Lavallée, S.3
Merloz, P.4
Pittet, L.5
Chirossel, J.P.6
-
5
-
-
0031388017
-
Active compliance in robotic surgery the use of force as a dynamic constraint
-
Davies B, Harris SJ, Lin WJ, Hibberd RD, Middleton R, Cobb JC. Active compliance in robotic surgery the use of force as a dynamic constraint. Proc Inst Mech Eng 1997;211:285-292.
-
(1997)
Proc Inst Mech Eng
, vol.211
, pp. 285-292
-
-
Davies, B.1
Harris, S.J.2
Lin, W.J.3
Hibberd, R.D.4
Middleton, R.5
Cobb, J.C.6
-
6
-
-
27744448671
-
A method for evaluating CT-based surgical registration
-
Troccaz J et al., editors. CVRMed-MRCAS '97. New York: Springer
-
Ellis RE, Fleet DJ, Bryant JT, Rudan J, Fenton P. A method for evaluating CT-based surgical registration. In: Troccaz J et al., editors. CVRMed-MRCAS '97. Lecture Notes in Computer Science Vol. 1205. New York: Springer; 1997. p 141-150.
-
(1997)
Lecture Notes in Computer Science
, vol.1205
, pp. 141-150
-
-
Ellis, R.E.1
Fleet, D.J.2
Bryant, J.T.3
Rudan, J.4
Fenton, P.5
-
7
-
-
84956620791
-
Computer assisted planning for total knee arthroplasty
-
Troccaz J et al., editors. CVRMed-MRCAS '97. New York: Springer
-
Fadda M, Bertelli D, Martelli S, Marcacci M., Dario P, Carmella D, Trippi D. Computer assisted planning for total knee arthroplasty. In: Troccaz J et al., editors. CVRMed-MRCAS '97. Lecture Notes in Computer Science Vol. 1205. New York: Springer, 1997. p 619-628.
-
(1997)
Lecture Notes in Computer Science
, vol.1205
, pp. 619-628
-
-
Fadda, M.1
Bertelli, D.2
Martelli, S.3
Marcacci, M.4
Dario, P.5
Carmella, D.6
Trippi, D.7
-
8
-
-
0030742408
-
Three-dimensonal computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
-
Fahrig R, Moreau M, Holdsworth DW. Three-dimensonal computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion. Med Phys 1997;24:1097-1106.
-
(1997)
Med Phys
, vol.24
, pp. 1097-1106
-
-
Fahrig, R.1
Moreau, M.2
Holdsworth, D.W.3
-
13
-
-
85069259703
-
Anatomy based registration of CT-scan and X-ray fluoroscopy data for intra-operative guidance of a surgical robot
-
Guéziec A, Kazanzides P, Williamson B, Taylor RH, Lord D. Anatomy based registration of CT-scan and X-ray fluoroscopy data for intra-operative guidance of a surgical robot. IEEE Trans Med Imaging 1998;17:410-419.
-
(1998)
IEEE Trans Med Imaging
, vol.17
, pp. 410-419
-
-
Guéziec, A.1
Kazanzides, P.2
Williamson, B.3
Taylor, R.H.4
Lord, D.5
-
15
-
-
0031904710
-
Automated 3-dimensional computer tomographic and fluoroscopic image registration
-
Hamadeh A, Lavallée S, Cinquin P. Automated 3-dimensional computer tomographic and fluoroscopic image registration. Comput Aided Surg 1998;3:11-19.
-
(1998)
Comput Aided Surg
, vol.3
, pp. 11-19
-
-
Hamadeh, A.1
Lavallée, S.2
Cinquin, P.3
-
16
-
-
0002093890
-
Fluoroscopy based surgical navigation - Concept and clinical applications
-
Lemke HU et al., editors. New York: Elsevier
-
Hofstetter R, Slomczykowski M, Bourquin I, Nolte LP. Fluoroscopy based surgical navigation - concept and clinical applications. In: Lemke HU et al., editors. Proceedings of the 11th International Symposium on Computer Assisted Radiology and Surgery (CAR '97). New York: Elsevier; 1997. p 956-960.
-
(1997)
Proceedings of the 11th International Symposium on Computer Assisted Radiology and Surgery (CAR '97)
, pp. 956-960
-
-
Hofstetter, R.1
Slomczykowski, M.2
Bourquin, I.3
Nolte, L.P.4
-
17
-
-
84956687756
-
Accuracy of image guided placement of iliosacral lag screws
-
Troccaz J et al., editors. Proceedings of CVRMed-MRCAS '97. New York: Springer
-
Hu R, Glossop N, Steven D, Randle J. Accuracy of image guided placement of iliosacral lag screws. In: Troccaz J et al., editors. Proceedings of CVRMed-MRCAS '97. Lecture Notes in Computer Science Vol. 1205. New York: Springer; 1997. p 593-596.
-
(1997)
Lecture Notes in Computer Science
, vol.1205
, pp. 593-596
-
-
Hu, R.1
Glossop, N.2
Steven, D.3
Randle, J.4
-
18
-
-
0005706942
-
Computer-integrated revision total hip replacement surgery: Preliminary report
-
Baltimore: Wiley
-
Joskowicz L, Taylor RH, Williamson B, Kane R, Kalvin A, Guéziec A, Taubin G, Funda J, Gomory S, Brown L, McCarthy J, Turner R. Computer-integrated revision total hip replacement surgery: Preliminary report. In: Second International Symposium on Medical Robotics and Computer Assisted Surgery. Baltimore: Wiley; 1995. p 193-202.
-
(1995)
Second International Symposium on Medical Robotics and Computer Assisted Surgery
, pp. 193-202
-
-
Joskowicz, L.1
Taylor, R.H.2
Williamson, B.3
Kane, R.4
Kalvin, A.5
Guéziec, A.6
Taubin, G.7
Funda, J.8
Gomory, S.9
Brown, L.10
McCarthy, J.11
Turner, R.12
-
19
-
-
2942553730
-
Computer-aided image-guided bone fracture surgery - Concept and implementation
-
Lemke HU et al., editors. New York: Elsevier
-
Joskowicz L, Tockus L, Yaniv Z, Simkin A, Milgrom C. Computer-aided image-guided bone fracture surgery - concept and implementation. In: Lemke HU et al., editors. Proceedings of the 12th International Symposium on Computer Assisted Radiology and Surgery (CAR '98). New York: Elsevier; 1998. p 710-715.
-
(1998)
Proceedings of the 12th International Symposium on Computer Assisted Radiology and Surgery (CAR '98)
, pp. 710-715
-
-
Joskowicz, L.1
Tockus, L.2
Yaniv, Z.3
Simkin, A.4
Milgrom, C.5
-
22
-
-
0029421473
-
Computer assisted spine surgery: A technique for accurate transpedicular screw fixation using CT data and a 3D optical localizer
-
Lavallée S, Sautot P, Troccaz J, Cinquin P, Merloz P. Computer assisted spine surgery: A technique for accurate transpedicular screw fixation using CT data and a 3D optical localizer. J Image Guided Surg 1995;1:65-73.
-
(1995)
J Image Guided Surg
, vol.1
, pp. 65-73
-
-
Lavallée, S.1
Sautot, P.2
Troccaz, J.3
Cinquin, P.4
Merloz, P.5
-
23
-
-
0000047330
-
Anatomy-based registration of three-dimensional medical images, range images, X-ray projections, and three-dimensional models using octree-splines
-
Taylor RH, Lavallée S, Burdea G, Mösges R, editors. Boston: MIT Press
-
Lavallée S, Szeliski R, Brunie L. Anatomy-based registration of three-dimensional medical images, range images, X-ray projections, and three-dimensional models using octree-splines. In: Taylor RH, Lavallée S, Burdea G, Mösges R, editors. Computer Integrated Surgery: Technology and Clinical Applications. Boston: MIT Press; 1995. p 115-143.
-
(1995)
Computer Integrated Surgery: Technology and Clinical Applications
, pp. 115-143
-
-
Lavallée, S.1
Szeliski, R.2
Brunie, L.3
-
24
-
-
0002375327
-
Computer-assisted spinal surgery using anatomy-based registration
-
Taylor RH, Lavallée S, Burdea G, Mösges R, editors. Boston: MIT Press
-
Lavallée S, Troccaz J, Sautot P, Mazier B, Cinquin P, Merloz P, Chirossel JP. Computer-assisted spinal surgery using anatomy-based registration. In: Taylor RH, Lavallée S, Burdea G, Mösges R, editors. Computer Integrated Surgery: Technology and Clinical Applications. Boston: MIT Press; 1995. p 425-449.
-
(1995)
Computer Integrated Surgery: Technology and Clinical Applications
, pp. 425-449
-
-
Lavallée, S.1
Troccaz, J.2
Sautot, P.3
Mazier, B.4
Cinquin, P.5
Merloz, P.6
Chirossel, J.P.7
-
25
-
-
84956645188
-
Computer-assisted knee surgical total replacement
-
Troccaz J et al., editors. Proceedings of CVRMed-MRCAS '97. New York: Springer
-
Leitner F, Picard F, Minfelde R, Schultz HJ, Cinquin P, Saragaglia D. Computer-assisted knee surgical total replacement. In: Troccaz J et al., editors. Proceedings of CVRMed-MRCAS '97. Lecture Notes in Computer Science, Vol. 1205. New York: Springer; 1997. p 629-637.
-
(1997)
Lecture Notes in Computer Science
, vol.1205
, pp. 629-637
-
-
Leitner, F.1
Picard, F.2
Minfelde, R.3
Schultz, H.J.4
Cinquin, P.5
Saragaglia, D.6
-
26
-
-
84971372881
-
Marching cubes: A high resolution 3D surface construction algorithm
-
Lorensen WE, Cline HE. Marching cubes: A high resolution 3D surface construction algorithm. SIGGRAPH '87 1987;21:163-169.
-
(1987)
SIGGRAPH '87
, vol.21
, pp. 163-169
-
-
Lorensen, W.E.1
Cline, H.E.2
-
27
-
-
84947798280
-
Computer-assisted transpedicular screw insertion
-
New York: Springer
-
Li QH, Holdener HJ, Zamorano L, Nolte LP, Visarius H, Diaz F. Computer-assisted transpedicular screw insertion. In: Lecture Notes in Computer Science. New York: Springer; 1996. p 328-335.
-
(1996)
Lecture Notes in Computer Science
, pp. 328-335
-
-
Li, Q.H.1
Holdener, H.J.2
Zamorano, L.3
Nolte, L.P.4
Visarius, H.5
Diaz, F.6
-
28
-
-
84907035999
-
Computer-aided fixation of spinal implants
-
Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L. Computer-aided fixation of spinal implants. J Image Guided Surg 1995;1:88-93.
-
(1995)
J Image Guided Surg
, vol.1
, pp. 88-93
-
-
Nolte, L.P.1
Visarius, H.2
Arm, E.3
Langlotz, F.4
Schwarzenbach, O.5
Zamorano, L.6
-
29
-
-
85069249763
-
Automatic feature detection in X-ray images for planning a drilling trajectory in orthopaedic surgery
-
Ozanian T, Phillips R, Viant W, Moshen A, Sherman K, Cain T. Automatic feature detection in X-ray images for planning a drilling trajectory in orthopaedic surgery. In: Proceedings of the Medical Image Understanding and Analysis Conference (MIAU '97), 1997. p 113-116.
-
(1997)
Proceedings of the Medical Image Understanding and Analysis Conference (MIAU '97)
, pp. 113-116
-
-
Ozanian, T.1
Phillips, R.2
Viant, W.3
Moshen, A.4
Sherman, K.5
Cain, T.6
-
30
-
-
0029489690
-
Image guided orthopaedic surgery: Design and analysis
-
Phillips R, Viant WJ, Moshen AMMA, Griffiths JG, Bell MA, Cain TJ, Sherman KP, Karpinski MRK. Image guided orthopaedic surgery: Design and analysis. Trans Inst Measure Control 1995;17:251-265.
-
(1995)
Trans Inst Measure Control
, vol.17
, pp. 251-265
-
-
Phillips, R.1
Viant, W.J.2
Moshen, A.M.M.A.3
Griffiths, J.G.4
Bell, M.A.5
Cain, T.J.6
Sherman, K.P.7
Karpinski, M.R.K.8
-
32
-
-
0027195363
-
Exposure of the orthopaedic surgeon to radiation
-
Sanders R. Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg 1993;75A:326-330.
-
(1993)
J Bone Joint Surg
, vol.75 A
, pp. 326-330
-
-
Sanders, R.1
-
33
-
-
0012001478
-
Accuracy assessment of a clinical biplane fluoroscope for three-dimensional measurements and targeting
-
Schreiner S, Funda J, Barnes AC, Anderson JH. Accuracy assessment of a clinical biplane fluoroscope for three-dimensional measurements and targeting. Proc SPIE Med Imaging, 1995. p 321-328.
-
(1995)
Proc SPIE Med Imaging
, pp. 321-328
-
-
Schreiner, S.1
Funda, J.2
Barnes, A.C.3
Anderson, J.H.4
-
34
-
-
0029421462
-
Techniques for fast and accurate intra-surgical registration
-
Simon DA. Techniques for fast and accurate intra-surgical registration. J Image Guided Surg 1995;1:17-29.
-
(1995)
J Image Guided Surg
, vol.1
, pp. 17-29
-
-
Simon, D.A.1
-
35
-
-
84956664679
-
Development and validation of a navigational guidance system for acetabular implant placement
-
Proceedings of CVRMed-MRCAS '97. New York: Springer
-
Simon DA, Jaramaz B, Blackwell M, Morgan F, DiGioia AM, Kischell E, Colgan B, Kanade T. Development and validation of a navigational guidance system for acetabular implant placement. In: Proceedings of CVRMed-MRCAS '97. Lecture Notes in Computer Science, Vol. 1205. New York: Springer, 1995. p 583-592.
-
(1995)
Lecture Notes in Computer Science
, vol.1205
, pp. 583-592
-
-
Simon, D.A.1
Jaramaz, B.2
Blackwell, M.3
Morgan, F.4
DiGioia, A.M.5
Kischell, E.6
Colgan, B.7
Kanade, T.8
-
36
-
-
0028442914
-
An image-directed robotic system for precise orthopaedic surgery
-
Taylor RH, Mittelstadt BD, Paul HA, Hanson W, Kazanzides P, Zuhars JF, Williamson B, Musits BL, Glassman E, Bargar WL. An image-directed robotic system for precise orthopaedic surgery. IEEE Trans Robotics Automation 1994;10:261-275.
-
(1994)
IEEE Trans Robotics Automation
, vol.10
, pp. 261-275
-
-
Taylor, R.H.1
Mittelstadt, B.D.2
Paul, H.A.3
Hanson, W.4
Kazanzides, P.5
Zuhars, J.F.6
Williamson, B.7
Musits, B.L.8
Glassman, E.9
Bargar, W.L.10
-
39
-
-
84947795762
-
Computer-aided image-guided bone fracture surgery: Modeling, visualization, and preoperative planning
-
Wells S et al., editors. First International Conference on Medical Computing and Computer-Assisted Intervention. New York: Elsevier
-
Tockus L, Joskowicz L, Simkin A, Milgrom C. Computer-aided image-guided bone fracture surgery: Modeling, visualization, and preoperative planning. In: Wells S et al., editors. First International Conference on Medical Computing and Computer-Assisted Intervention. Lecture Notes in Computer Science, Vol. 1496. New York: Elsevier; 1998. p 29-38.
-
(1998)
Lecture Notes in Computer Science
, vol.1496
, pp. 29-38
-
-
Tockus, L.1
Joskowicz, L.2
Simkin, A.3
Milgrom, C.4
-
40
-
-
0023397578
-
A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
-
Tsai R. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE J Robotics Automation 1998;RA-3:323-344.
-
(1998)
IEEE J Robotics Automation
, vol.RA-3
, pp. 323-344
-
-
Tsai, R.1
-
41
-
-
0031365203
-
A computer assisted orthopaedic system for distal locking of intramedullary nails
-
Viant WJ, Phillips R, Griffiths JG, et al. A computer assisted orthopaedic system for distal locking of intramedullary nails. Proc Inst Mech Eng 1997;211(H): 1-8.
-
(1997)
Proc Inst Mech Eng
, vol.211
, Issue.H
, pp. 1-8
-
-
Viant, W.J.1
Phillips, R.2
Griffiths, J.G.3
-
43
-
-
84947740842
-
Fluoroscopic image processing for computer-aided orthopaedic surgery
-
Wells S et al., editors. First International Conference on Medical Computing and Computer-Assisted Intervention. New York: Elsevier
-
Yaniv Z, Joskowicz L, Simin A, Garza-Jinich M, Milgrom. Fluoroscopic image processing for computer-aided orthopaedic surgery. In: Wells S et al., editors. First International Conference on Medical Computing and Computer-Assisted Intervention. Lecture Notes in Computer Science, Vol. 1496. New York: Elsevier; 1998. p 325-334
-
(1998)
Lecture Notes in Computer Science
, vol.1496
, pp. 325-334
-
-
Yaniv, Z.1
Joskowicz, L.2
Simin, A.3
Garza-Jinich, M.4
Milgrom5
|