메뉴 건너뛰기




Volumn 41, Issue 6, 2003, Pages 630-639

Ring electrode for radio-frequency heating of the cornea: Modelling and in vitro experiments

Author keywords

Computer model; Cornea; Finite element method; Hyperopia; Radio frequency; Thermokeratoplasty

Indexed keywords

DISEASE CONTROL; DISEASES; ELECTRODES; FINITE ELEMENT METHOD; VISION;

EID: 0345531155     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02349970     Document Type: Article
Times cited : (18)

References (42)
  • 1
    • 0031039661 scopus 로고    scopus 로고
    • 'Correction of hyperopia induced by photorefractive keratectomy using non-contact Ho: YAG laser thermal keratoplasty'
    • Alió, J. L., Ismail, M. M., Artola, A., and Pérez-Santonja, J. J. (1997a): 'Correction of hyperopia induced by photorefractive keratectomy using non-contact Ho: YAG laser thermal keratoplasty', J. Refract. Surg., 13, pp. 13-16
    • (1997) J. Refract. Surg. , vol.13 , pp. 13-16
    • Alió, J.L.1    Ismail, M.M.2    Artola, A.3    Pérez-Santonja, J.J.4
  • 2
    • 0031054875 scopus 로고    scopus 로고
    • 'Correction of hyperopia with non-contact Ho: YAG laser thermal keratoplasty'
    • Alió, J. L., Ismail, M. M., and Sanchez, J. L. (1997b): 'Correction of hyperopia with non-contact Ho: YAG laser thermal keratoplasty', J. Refract. Surg., 13, pp. 17-22
    • (1997) J. Refract. Surg. , vol.13 , pp. 17-22
    • Alió, J.L.1    Ismail, M.M.2    Sanchez, J.L.3
  • 3
    • 0345357368 scopus 로고    scopus 로고
    • 'Correction of hyperopia by laser thermokeratoplasty (LTK)'
    • Pallikaris, I., and Agarwal, S. (Eds): (Jaypee Brothers Medical Publishers Ltd, New Delhi, 1999)
    • Alió, J. L., and Pérez-Santonja, J. J. (1999): 'Correction of hyperopia by laser thermokeratoplasty (LTK)' in Pallikaris, I., and Agarwal, S. (Eds): 'Refractive Surgery' (Jaypee Brothers Medical Publishers Ltd, New Delhi, 1999), pp. 583-591
    • (1999) 'Refractive Surgery' , pp. 583-591
    • Alió, J.L.1    Pérez-Santonja, J.J.2
  • 4
    • 0344925986 scopus 로고    scopus 로고
    • 'Corrrection of hyperopia by laser thermokeratoplasty (LTK)'
    • Agarwal, S., Agarwal, A., Apple, D. J., Buratto, L., Alió, J. L., Pandey, S. K., and Agarwal, A. (Eds): (Lippincott Williams & Wilkins, Philadelphia, 2002)
    • Alió, J. L., and Pérez-Santonja, J. J. (2002): 'Corrrection of hyperopia by laser thermokeratoplasty (LTK)' in Agarwal, S., Agarwal, A., Apple, D. J., Buratto, L., Alió, J. L., Pandey, S. K., and Agarwal, A. (Eds): 'Textbook of ophthalmology' (Lippincott Williams & Wilkins, Philadelphia, 2002), pp. 1331-1337
    • (2002) 'Textbook of Ophthalmology' , pp. 1331-1337
    • Alió, J.L.1    Pérez-Santonja, J.J.2
  • 5
    • 0034276608 scopus 로고    scopus 로고
    • 'Experimental corneal histological study after thermokeratoplasty with holmium laser'
    • Ayala, M. J., Alió, J. L., Ismail, M. M., and Sánchez-Castro, J. M. (2000): 'Experimental corneal histological study after thermokeratoplasty with holmium laser', Arch. Soc. Esp. Oftalmol., 75, pp. 619-626
    • (2000) Arch. Soc. Esp. Oftalmol. , vol.75 , pp. 619-626
    • Ayala, M.J.1    Alió, J.L.2    Ismail, M.M.3    Sánchez-Castro, J.M.4
  • 6
    • 0035751166 scopus 로고    scopus 로고
    • 'Conductive keratoplasty for the correction of hyperopia'
    • and Conductive Keratoplasty Study Group
    • Asbell, P. A., Maloney, R. K., Davidorf, J., Hersh, P., McDonald, M., Manche, E., and Conductive Keratoplasty Study Group (2001): 'Conductive keratoplasty for the correction of hyperopia', Tr. Am. Ophtalmol. Soc., 99, pp. 79-87
    • (2001) Tr. Am. Ophtalmol. Soc. , vol.99 , pp. 79-87
    • Asbell, P.A.1    Maloney, R.K.2    Davidorf, J.3    Hersh, P.4    McDonald, M.5    Manche, E.6
  • 7
    • 0031436188 scopus 로고    scopus 로고
    • 'The effects of electrode-tissue contact on radiofrequency lesion generation'
    • Avitall, B., Mughal, K., Hare, J., Helms, R., and Krum, D. (1997): 'The effects of electrode-tissue contact on radiofrequency lesion generation', PACE, 20, pp. 2899-2910
    • (1997) PACE , vol.20 , pp. 2899-2910
    • Avitall, B.1    Mughal, K.2    Hare, J.3    Helms, R.4    Krum, D.5
  • 8
    • 0033558690 scopus 로고    scopus 로고
    • 'The creation of linear contiguous lesions in the atria with an expandable loop catheter'
    • Avitall, B., Helms, R. W., Koblish, J. B., Sieben, W., Kotov, A. V., and Gupta, G. N. (1999): 'The creation of linear contiguous lesions in the atria with an expandable loop catheter', J. Am. Coll. Cardiol., 33, pp. 972-984
    • (1999) J. Am. Coll. Cardiol. , vol.33 , pp. 972-984
    • Avitall, B.1    Helms, R.W.2    Koblish, J.B.3    Sieben, W.4    Kotov, A.V.5    Gupta, G.N.6
  • 9
    • 0036172576 scopus 로고    scopus 로고
    • 'Radio-frequency heating of the cornea: Theoretical model and in vitro experiments'
    • Berjano, E. J., Saiz, J., and Ferrero, J. M. (2002): 'Radio-frequency heating of the cornea: Theoretical model and in vitro experiments', IEEE Trans. Biomed. Eng., 49, pp. 196-205
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , pp. 196-205
    • Berjano, E.J.1    Saiz, J.2    Ferrero, J.M.3
  • 11
    • 0036932909 scopus 로고    scopus 로고
    • 'Dynamic impedance measurements during radio-frequency heating of cornea'
    • Choi, B., Kim, J., Welch, A. J., and Pearce, J. A. (2002): 'Dynamic impedance measurements during radio-frequency heating of cornea', IEEE Trans. Biomed. Eng., 49, pp. 1610-1616
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , pp. 1610-1616
    • Choi, B.1    Kim, J.2    Welch, A.J.3    Pearce, J.A.4
  • 12
    • 0031294107 scopus 로고    scopus 로고
    • 'Creation of large thermal lesions in liver using saline-enhanced RF ablation'
    • Chicago
    • Curley, M. G., and Hamilton, P. S. (1997): 'Creation of large thermal lesions in liver using saline-enhanced RF ablation'. Proc. 19th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc., Chicago, pp. 2516-2519
    • (1997) Proc. 19th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. , pp. 2516-2519
    • Curley, M.G.1    Hamilton, P.S.2
  • 13
    • 0018838740 scopus 로고
    • 'A technique for the selective heating of corneal stroma'
    • Doss, J. D., and Albillar, J. I. (1980): 'A technique for the selective heating of corneal stroma', Contact Intraocular Lens Med., 6, pp. 13-17
    • (1980) Contact Intraocular Lens Med. , vol.6 , pp. 13-17
    • Doss, J.D.1    Albillar, J.I.2
  • 14
    • 0019969360 scopus 로고
    • 'Calculation of electric fields in conductive media'
    • Doss, J. D. (1982): 'Calculation of electric fields in conductive media', Med. Phys., 9(4), pp. 566-573
    • (1982) Med. Phys. , vol.9 , Issue.4 , pp. 566-573
    • Doss, J.D.1
  • 15
    • 0019427674 scopus 로고
    • 'Increase in rabbit corneal curvature by heated ring application'
    • Gruenberg, P., Manning, W., Miller, D., and Olson, W. (1981): 'Increase in rabbit corneal curvature by heated ring application', Ann. Ophthalmol., 13, pp. 67-70
    • (1981) Ann. Ophthalmol. , vol.13 , pp. 67-70
    • Gruenberg, P.1    Manning, W.2    Miller, D.3    Olson, W.4
  • 16
    • 26744460873 scopus 로고    scopus 로고
    • 'Catheter for circular tissue ablation and methods thereof'
    • US Patent 2001/0044625 A1
    • Hata, C., and Raymond Chia, W.-K. (2001): 'Catheter for circular tissue ablation and methods thereof'. US Patent 2001/0044625 A1
    • (2001)
    • Hata, C.1    Raymond Chia, W.-K.2
  • 17
    • 0008370929 scopus 로고    scopus 로고
    • 'Effect of electrode contact on lesion growth during temperature controlled radiofrequency ablation'
    • (IEEE Piscataway NJ)
    • Jain, M. K., and Wolf, P. D. (1998): 'Effect of electrode contact on lesion growth during temperature controlled radiofrequency ablation', Proc. 20th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. Hong Kong (IEEE Piscataway NJ) pp. 245-247
    • (1998) Proc. 20th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. Hong Kong , pp. 245-247
    • Jain, M.K.1    Wolf, P.D.2
  • 18
    • 0033485373 scopus 로고    scopus 로고
    • 'Temperature controlled and constant power radiofrequency ablation: What affects lesion growth?'
    • Jain, M. K., and Wolf, P. D. (1999): 'Temperature controlled and constant power radiofrequency ablation: what affects lesion growth?', IEEE Trans. Biomed. Eng., 46, pp. 1405-1412
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , pp. 1405-1412
    • Jain, M.K.1    Wolf, P.D.2
  • 19
    • 0345357365 scopus 로고    scopus 로고
    • 'Estimation of current density distribution under electrodes for external defibrillation'
    • Krasteva, V. Tz., and Papazov, S. P. (2002): 'Estimation of current density distribution under electrodes for external defibrillation', Biomed. Eng. OnLine, 1, 7
    • (2002) Biomed. Eng. OnLine , vol.1 , pp. 7
    • Krasteva, V.T.Z.1    Papazov, S.P.2
  • 20
    • 0008321252 scopus 로고
    • 'A theoretical study of radio-frequency ablation of the myocardium'
    • PhD dissertation Department of Electrical Engineering, University of Ottawa, Canada
    • Labonté, S. (1992): 'A theoretical study of radio-frequency ablation of the myocardium', PhD dissertation, Department of Electrical Engineering, University of Ottawa, Canada
    • (1992)
    • Labonté, S.1
  • 21
    • 0028287746 scopus 로고
    • 'Numerical model for radio-frequency ablation of the endocardium and its experimental validation'
    • Labonté, S. (1994): 'Numerical model for radio-frequency ablation of the endocardium and its experimental validation', IEEE Trans. Biomed. Eng., 41, pp. 108-115
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 108-115
    • Labonté, S.1
  • 22
    • 0034904275 scopus 로고    scopus 로고
    • 'Making sense of refractive surgery in 2001: Why, when, for whom, and by whom?'
    • Mannis, M. J., Segal, W. A., and Darlington, J. K. (2001): 'Making sense of refractive surgery in 2001: Why, when, for whom, and by whom?', Mayo Clin. Proc., 76, pp. 823-829
    • (2001) Mayo Clin. Proc. , vol.76 , pp. 823-829
    • Mannis, M.J.1    Segal, W.A.2    Darlington, J.K.3
  • 24
    • 0036841036 scopus 로고    scopus 로고
    • 'Conductive keratoplasty for the correction of low to moderate hyperopia: U.S. clinical trial 1-year results on 355 eyes'
    • McDonald, M. B., Hersh, P. S., Manche, E. E., Maloney, R. K., Davidorf, J., and Sabry, M. (2002): 'Conductive keratoplasty for the correction of low to moderate hyperopia: U.S. clinical trial 1-year results on 355 eyes', Ophthalmol., 109, pp. 1978-1989
    • (2002) Ophthalmol. , vol.109 , pp. 1978-1989
    • McDonald, M.B.1    Hersh, P.S.2    Manche, E.E.3    Maloney, R.K.4    Davidorf, J.5    Sabry, M.6
  • 25
    • 0030686445 scopus 로고    scopus 로고
    • 'Non-uniform heating during radiofrequency ablation with long electrodes: Monitoring the edge effect'
    • McRury, I. D., Mitchell, M. A., Panescu, D., and Haines, D. E. (1997): 'Non-uniform heating during radiofrequency ablation with long electrodes: monitoring the edge effect', Circ., 96, pp. 4057-4064
    • (1997) Circ. , vol.96 , pp. 4057-4064
    • McRury, I.D.1    Mitchell, M.A.2    Panescu, D.3    Haines, D.E.4
  • 26
    • 0000311314 scopus 로고    scopus 로고
    • 'Conductive keratoplasty of the correction of hyperopia'
    • Sher, N. A. (Ed.): (Williams & Wilkins, Baltimore, 1997)
    • Méndez-g, A., and Méndez-Noble, A. (1997): 'Conductive keratoplasty of the correction of hyperopia' in Sher, N. A. (Ed.): 'Surgery for hyperopia and presbyopia' (Williams & Wilkins, Baltimore, 1997), pp. 163-171
    • (1997) 'Surgery for Hyperopia and Presbyopia' , pp. 163-171
    • Méndez-g, A.1    Méndez-Noble, A.2
  • 27
    • 84862018511 scopus 로고
    • 'Alterations in curvature of bovine cornea using heated rings'
    • Miller, D., and Manning, W.J. (1978): 'Alterations in curvature of bovine cornea using heated rings', Invest. Ophthalmol., p. 297
    • (1978) Invest. Ophthalmol. , pp. 297
    • Miller, D.1    Manning, W.J.2
  • 28
    • 0029958234 scopus 로고    scopus 로고
    • 'Nonuniform heating patterns of commercial electrodes for radiofrequency catheter ablation'
    • Mirotznik, M. S., and Schwartzman, D. (1996): 'Nonuniform heating patterns of commercial electrodes for radiofrequency catheter ablation', J. Cardiovasc. Electrophysiol., 7, pp. 1058-1062
    • (1996) J. Cardiovasc. Electrophysiol. , vol.7 , pp. 1058-1062
    • Mirotznik, M.S.1    Schwartzman, D.2
  • 29
    • 0028942447 scopus 로고
    • 'Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation'
    • Nakagawa, H., Yamanashi, W. S., Pitha, J. V., Arruda, M., Wang, X., Ohtomo, K., Beckman, K. J., McClelland, J. H., Lazzara, R., and Jackman, W. M. (1995): 'Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation', Circ., 91, pp. 2264-2273
    • (1995) Circ. , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3    Arruda, M.4    Wang, X.5    Ohtomo, K.6    Beckman, K.J.7    McClelland, J.H.8    Lazzara, R.9    Jackman, W.M.10
  • 30
    • 0029361149 scopus 로고
    • 'Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation'
    • Panescu, D., Whayne, J. G., Fleischman, S. D., Mirotznik, M. S., Swanson, D. K., and Webster, J. G. (1995): 'Three-dimensional finite element analysis of current density and temperature distributions during radio-frequency ablation', IEEE Trans. Biomed. Eng., 42, pp. 879-890
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 879-890
    • Panescu, D.1    Whayne, J.G.2    Fleischman, S.D.3    Mirotznik, M.S.4    Swanson, D.K.5    Webster, J.G.6
  • 31
    • 0014188995 scopus 로고
    • 'Considerations of quasistationarity in electrophysiological systems'
    • Plonsey, R., and Heppner, D. B. (1967): 'Considerations of quasistationarity in electrophysiological systems', Bull. Math. Biophys., 29, pp. 657-664
    • (1967) Bull. Math. Biophys. , vol.29 , pp. 657-664
    • Plonsey, R.1    Heppner, D.B.2
  • 32
    • 0000664612 scopus 로고
    • 'Electrosurgical keratoplasty: Update and retraction'
    • Rowsey, J. J. (1987): 'Electrosurgical keratoplasty: Update and retraction', Invest. Ophthalmol. Vis. Sci., 28, p. 224
    • (1987) Invest. Ophthalmol. Vis. Sci. , vol.28 , pp. 224
    • Rowsey, J.J.1
  • 34
    • 0018924213 scopus 로고
    • 'RF-fields interactions with biological systems: Electrical properties and biophysical mechanism'
    • Schwan, H. P., and Foster, K. R. (1980): 'RF-fields interactions with biological systems: electrical properties and biophysical mechanism', Proc. IEEE, 68, pp. 104-113
    • (1980) Proc. IEEE , vol.68 , pp. 104-113
    • Schwan, H.P.1    Foster, K.R.2
  • 35
    • 0025119174 scopus 로고
    • 'Laser thermokeratoplasty by means of a pulsed Holmium: YAG Laser for the hyperopic correction'
    • Seiler, T., Matallana, M., and Bende, T. (1990): 'Laser thermokeratoplasty by means of a pulsed Holmium:YAG Laser for the hyperopic correction', Refrac. Corneal Surg., 6, pp. 335-339
    • (1990) Refrac. Corneal Surg. , vol.6 , pp. 335-339
    • Seiler, T.1    Matallana, M.2    Bende, T.3
  • 36
    • 26744451698 scopus 로고    scopus 로고
    • 'Electrosurgical procedure for the treatment of the cornea'
    • US Patent 5,766,171
    • Silvestrini, T. A. (1998): 'Electrosurgical procedure for the treatment of the cornea'. US Patent 5,766,171
    • (1998)
    • Silvestrini, T.A.1
  • 37
    • 0029981873 scopus 로고    scopus 로고
    • 'Comparison of gold versus platinum electrodes on myocardial lesion size using radiofrequency energy'
    • Simmons, W. N., Mackey, S., He, D. S., and Marcus, F. I. (1996): 'Comparison of gold versus platinum electrodes on myocardial lesion size using radiofrequency energy', PACE, 19, pp. 398-402
    • (1996) PACE , vol.19 , pp. 398-402
    • Simmons, W.N.1    Mackey, S.2    He, D.S.3    Marcus, F.I.4
  • 38
    • 37049058116 scopus 로고
    • 'Shrinkage temperature of eye collagen'
    • Stringer, H., and Parr, J. (1964): 'Shrinkage temperature of eye collagen', Nature, 204, p. 1307
    • (1964) Nature , vol.204 , pp. 1307
    • Stringer, H.1    Parr, J.2
  • 39
    • 0026102084 scopus 로고
    • 'Combined microwave heating and surface cooling of the cornea'
    • Trembly, B. S., and Keates, R. H. (1991): 'Combined microwave heating and surface cooling of the cornea', IEEE Trans. Biomed. Eng., 38, pp. 85-91
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 85-91
    • Trembly, B.S.1    Keates, R.H.2
  • 41
    • 0034281949 scopus 로고    scopus 로고
    • 'Thermal-electrical finite element modelling for radio frequency cardiac ablation: Effects of changes in myocardial properties'
    • Tungjitkusolmun, S., Woo, E. J., Cao, H., Tsai, J. Z., Vorperian, V. R., and Webster, J. G. (2000): 'Thermal-electrical finite element modelling for radio frequency cardiac ablation: effects of changes in myocardial properties', Med. Biol. Eng. Comput., 38, pp. 562-568
    • (2000) Med. Biol. Eng. Comput. , vol.38 , pp. 562-568
    • Tungjitkusolmun, S.1    Woo, E.J.2    Cao, H.3    Tsai, J.Z.4    Vorperian, V.R.5    Webster, J.G.6
  • 42
    • 0020332065 scopus 로고
    • 'Analysis and control of the current distribution under circular dispersive electrodes'
    • Wiley, J. D., and Webster, J. G. (1982): 'Analysis and control of the current distribution under circular dispersive electrodes', IEEE Trans. Biomed. Eng., 29, pp. 381-385
    • (1982) IEEE Trans. Biomed. Eng. , vol.29 , pp. 381-385
    • Wiley, J.D.1    Webster, J.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.