1
-
-
0025095887
-
Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
-
Langberg JJ, Lee MA, Chin MC, et al: Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo. PACE 1990;13:1242-1248.
-
(1990)
PACE
, vol.13
, pp. 1242-1248
-
-
Langberg, J.J.1
Lee, M.A.2
Chin, M.C.3
-
2
-
-
85035175113
-
Results of linear right atrial radiofrequency ablation with a temperature controlled, multiple coil electrode catheter
-
Mitchell MA, McRury ID, Haines DE: Results of linear right atrial radiofrequency ablation with a temperature controlled, multiple coil electrode catheter. (Abstract) J Am Coll Cardiol 1996;27:400A.
-
(1996)
J Am Coll Cardiol
, vol.27
-
-
Mitchell, M.A.1
McRury, I.D.2
Haines, D.E.3
-
3
-
-
0024714897
-
Theoretical and experimental SAR distributions for interstitial dipole antenna arrays used in hyperthermia
-
Jones KM, Mechling JA, Strohbehn JW, et al: Theoretical and experimental SAR distributions for interstitial dipole antenna arrays used in hyperthermia. IEEE Trans Microwave Theory Technol 1989;37:1200-1209.
-
(1989)
IEEE Trans Microwave Theory Technol
, vol.37
, pp. 1200-1209
-
-
Jones, K.M.1
Mechling, J.A.2
Strohbehn, J.W.3
-
4
-
-
0030168516
-
High resolution measurements of the specific absorption rate of small antennas in lossy media
-
Mirotznik MS, Cheever E, Foster KR: High resolution measurements of the specific absorption rate of small antennas in lossy media. IEEE Trans Instrument Measurements 1996;45:754-756.
-
(1996)
IEEE Trans Instrument Measurements
, vol.45
, pp. 754-756
-
-
Mirotznik, M.S.1
Cheever, E.2
Foster, K.R.3
-
6
-
-
10544256626
-
The behavior of electromagnetic fields at edges
-
Meixner J: The behavior of electromagnetic fields at edges. IEEE Trans Antennas Propagation 1985;AP-33: 450-455.
-
(1985)
IEEE Trans Antennas Propagation
, vol.AP-33
, pp. 450-455
-
-
Meixner, J.1
-
7
-
-
0024763785
-
27 MHz conformal capacitive ring (CR) applicators for uniform hyperthermic/diathermic treatment of body segments with axial fields
-
Raganella L, Band G, Vanucci I, et al: 27 MHz conformal capacitive ring (CR) applicators for uniform hyperthermic/diathermic treatment of body segments with axial fields. IEEE Trans Biomed Eng 1989;36: 1124-1132.
-
(1989)
IEEE Trans Biomed Eng
, vol.36
, pp. 1124-1132
-
-
Raganella, L.1
Band, G.2
Vanucci, I.3
-
8
-
-
0024000433
-
Estimation of temperature distribution inside tissues heated by interstitial radiofrequency electrode hyperthermia systems
-
Uzunoglu NK, Nikita KS: Estimation of temperature distribution inside tissues heated by interstitial radiofrequency electrode hyperthermia systems. IEEE Trans Biomed Eng 1988;35:250-256.
-
(1988)
IEEE Trans Biomed Eng
, vol.35
, pp. 250-256
-
-
Uzunoglu, N.K.1
Nikita, K.S.2
-
10
-
-
0027936361
-
Temperature monitoring during radiofrequency catheter ablation procedures using closed loop control
-
Calkins H, Prystowsky E, Carlson M, et al, and the Atakr Multicenter Investigators Group: Temperature monitoring during radiofrequency catheter ablation procedures using closed loop control. Circulation 1994;90:1279-1286.
-
(1994)
Circulation
, vol.90
, pp. 1279-1286
-
-
Calkins, H.1
Prystowsky, E.2
Carlson, M.3
-
11
-
-
10544235464
-
Temperature guided radiofrequency catheter ablation: Sudden increase in catheter tip temperature as a marker of coagulum formation without abrupt impedance rise
-
Adragao P, Parreira L, Morgado F, et al: Temperature guided radiofrequency catheter ablation: Sudden increase in catheter tip temperature as a marker of coagulum formation without abrupt impedance rise. (Abstract) PACE 1996;19:652.
-
(1996)
PACE
, vol.19
, pp. 652
-
-
Adragao, P.1
Parreira, L.2
Morgado, F.3
|