메뉴 건너뛰기




Volumn 27, Issue 5, 2000, Pages 923-934

Slit x-ray beam primary dose profiles determined by analytical transport of Compton recoil electrons

Author keywords

Analytic model; Detector spatial response; Electron transport; Line spread function; Primary dose

Indexed keywords

ANALYTICAL MODELS; ELECTRON TRANSPORT PROPERTIES; LINEAR ACCELERATORS; PARTICLE BEAMS; PHOTOELECTRONS; PHOTONS; X RAYS;

EID: 0343183005     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598958     Document Type: Article
Times cited : (5)

References (51)
  • 1
    • 0026793771 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beams: II. Properties and measurements
    • A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water-equivalent plastic scintillation detectors for high-energy beams: II. Properties and measurements," Phys. Med. Biol. 37, 1901-1913 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1901-1913
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 3
    • 0021227635 scopus 로고
    • Analysis of physical parameters associated with the measurement of high-energy x-ray penumbra
    • D. J. Dawson, J. M. Harper, and A. C. Akinradewo, "Analysis of physical parameters associated with the measurement of high-energy x-ray penumbra," Med. Phys. 11, 491-497 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 491-497
    • Dawson, D.J.1    Harper, J.M.2    Akinradewo, A.C.3
  • 4
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic plaque dosimetry
    • D. Fluhs, M. Heintz, F. Indenkampen, and C. Wieczorek, "Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic plaque dosimetry," Med. Phys. 23, 427-434 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 427-434
    • Fluhs, D.1    Heintz, M.2    Indenkampen, F.3    Wieczorek, C.4
  • 7
    • 0023632209 scopus 로고
    • Measurements of dose distributions in small beams of 6 MV x-rays
    • R. K. Rice, J. L. Hansen, G. K. Svensson, and R. L. Siddon, "Measurements of dose distributions in small beams of 6 MV x-rays," Phys. Med. Biol. 32, 1087-1099 (1987).
    • (1987) Phys. Med. Biol. , vol.32 , pp. 1087-1099
    • Rice, R.K.1    Hansen, J.L.2    Svensson, G.K.3    Siddon, R.L.4
  • 8
    • 0028218940 scopus 로고
    • The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics
    • W. L. McLaughlin, C. G. Soares, J. A. Sayeg, E. C. McCullough, R. W. Kline, A. Wu, and A. H. Maitz, "The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics," Med. Phys. 21, 379-388 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 379-388
    • McLaughlin, W.L.1    Soares, C.G.2    Sayeg, J.A.3    McCullough, E.C.4    Kline, R.W.5    Wu, A.6    Maitz, A.H.7
  • 9
    • 0028349847 scopus 로고
    • The use of radiochromic film in the verification of stereotactic radiosurgery
    • R. Ramani, A. W. Lightstone, D. L. D. Mason, and P. F. O'Brien, "The use of radiochromic film in the verification of stereotactic radiosurgery," Med. Phys. 21, 389-392 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 389-392
    • Ramani, R.1    Lightstone, A.W.2    Mason, D.L.D.3    O'Brien, P.F.4
  • 11
    • 0019433296 scopus 로고
    • Correction of a measured distribution for the finite extension of the detector
    • A. Brahme, "Correction of a measured distribution for the finite extension of the detector," Strahlentherapie 157, 258-259 (1981).
    • (1981) Strahlentherapie , vol.157 , pp. 258-259
    • Brahme, A.1
  • 12
    • 0031886274 scopus 로고    scopus 로고
    • Experimental determination of the convolution kernel for the study of the spatial response of a detector
    • F. García-Vicente, J. M. Delgado, and C. Peraza, "Experimental determination of the convolution kernel for the study of the spatial response of a detector," Med. Phys. 25, 202-207 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 202-207
    • García-Vicente, F.1    Delgado, J.M.2    Peraza, C.3
  • 13
    • 0028799438 scopus 로고
    • Deconvolution of detector size effect for small field measurement
    • P. D. Higgins, C. H. Sibata, L. Siskind, and J. W. Sohn, "Deconvolution of detector size effect for small field measurement," Med. Phys. 22, 1663-1666 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1663-1666
    • Higgins, P.D.1    Sibata, C.H.2    Siskind, L.3    Sohn, J.W.4
  • 14
    • 0031911699 scopus 로고    scopus 로고
    • The use of deconvolution and total least squares in recovering a radiation detector line spread function
    • P. Charland, E. El-Khatib, and J. Wolters, "The use of deconvolution and total least squares in recovering a radiation detector line spread function," Med. Phys. 25, 152-160 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 152-160
    • Charland, P.1    El-Khatib, E.2    Wolters, J.3
  • 15
    • 0028783942 scopus 로고
    • Dosimetric characterization of radiosurgical beams with a diamond detector
    • S. N. Rustgi and D. M. D. Frye, "Dosimetric characterization of radiosurgical beams with a diamond detector," Med. Phys. 22, 2117-2121 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 2117-2121
    • Rustgi, S.N.1    Frye, D.M.D.2
  • 16
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetry techniques in stereotactic radiosurgery
    • M. Heydarian, P. W. Hoban, and A. H. Beddoe, "A comparison of dosimetry techniques in stereotactic radiosurgery," Phys. Med. Biol. 41, 93-110 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 17
    • 0032936611 scopus 로고    scopus 로고
    • An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams
    • P. N. Mobit and G. A. Sandison, "An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams," Med. Phys. 26, 839-844 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 839-844
    • Mobit, P.N.1    Sandison, G.A.2
  • 18
    • 0029004417 scopus 로고
    • Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements
    • S. N. Rustgi, "Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements," Med. Phys. 22, 567-570 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 567-570
    • Rustgi, S.N.1
  • 19
    • 0027393650 scopus 로고
    • Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy
    • S. Vatnitsky and H. Järvinen, "Application of a natural diamond detector for the measurement of relative dose distributions in radiotherapy," Phys. Med. Biol. 38, 173-184 (1993).
    • (1993) Phys. Med. Biol. , vol.38 , pp. 173-184
    • Vatnitsky, S.1    Järvinen, H.2
  • 20
    • 0032692443 scopus 로고    scopus 로고
    • A Monte Carlo comparison in the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams
    • P. N. Mobit and G. A. Sandison, "A Monte Carlo comparison in the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams," Med. Phys. 26, 2503-2507 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2503-2507
    • Mobit, P.N.1    Sandison, G.A.2
  • 21
    • 0026750950 scopus 로고
    • A pencil beam model for photon dose calculation
    • A. Ahnesjö, M. Saxner, and A. Trepp, "A pencil beam model for photon dose calculation," Med. Phys. 19, 263-273 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 263-273
    • Ahnesjö, A.1    Saxner, M.2    Trepp, A.3
  • 22
    • 0023280868 scopus 로고
    • Calculation and application of point spread functions for treatment planning with high energy photon beams
    • A. Ahnesjö, P. Andreo, and A. Brahme, "Calculation and application of point spread functions for treatment planning with high energy photon beams," Acta Oncol. 26, 49-56 (1987).
    • (1987) Acta Oncol. , vol.26 , pp. 49-56
    • Ahnesjö, A.1    Andreo, P.2    Brahme, A.3
  • 24
    • 0029113891 scopus 로고
    • Photon dose calculation incorporating explicit electron transport
    • C. X. Yu, T. R. Mackie, and J. W. Wong, "Photon dose calculation incorporating explicit electron transport," Med. Phys. 22, 1157-1165 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1157-1165
    • Yu, C.X.1    Mackie, T.R.2    Wong, J.W.3
  • 26
    • 0032918665 scopus 로고    scopus 로고
    • Review of photon interaction cross section data in the medical and biological context
    • J. H. Hubbell, "Review of photon interaction cross section data in the medical and biological context," Phys. Med. Biol. 44, R1-R22 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Hubbell, J.H.1
  • 27
    • 0032772957 scopus 로고    scopus 로고
    • Photon dose calculation based on electron multiple scattering theory: Primary dose deposition kernels
    • L. Wang and D. Jette, "Photon dose calculation based on electron multiple scattering theory: Primary dose deposition kernels," Med. Phys. 26, 1454-1465 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1454-1465
    • Wang, L.1    Jette, D.2
  • 29
    • 33744563370 scopus 로고
    • edited by F. H. Attix and W. C. Roesch Academic, New York
    • R. D. Evans, Radiation Dosimetry, Vol. I, Fundamentals, edited by F. H. Attix and W. C. Roesch (Academic, New York 1968), p. 106-109.
    • (1968) Radiation Dosimetry, Vol. I, Fundamentals , vol.1 , pp. 106-109
    • Evans, R.D.1
  • 30
    • 33744681131 scopus 로고
    • Quantum and Statistical Physics Addison Wesley, Reading, MA
    • M. Alonso, E. J. Finn, Fundamental University Physics, Vol. III, Quantum and Statistical Physics (Addison Wesley, Reading, MA, 1979), pp. 14-21.
    • (1979) Fundamental University Physics , vol.3 , pp. 14-21
    • Alonso, M.1    Finn, E.J.2
  • 31
    • 0023932761 scopus 로고
    • Electron dose calculation using multiple-scattering theory A. Gaussian multiple-scattering theory
    • D. Jette, "Electron dose calculation using multiple-scattering theory A. Gaussian multiple-scattering theory," Med. Phys. 15, 123-137 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 123-137
    • Jette, D.1
  • 32
    • 85027233851 scopus 로고
    • Radiation dosimetry: Electron beams with energies between 1 and 50 MeV
    • Report 35 ICRU, Bethesda
    • Data of M. J. Berger in "Radiation dosimetry: Electron beams with energies between 1 and 50 MeV," International Commission on Radiation Units and Measurements, Report 35 (ICRU, Bethesda, 1984), p. 8.
    • (1984) International Commission on Radiation Units and Measurements , pp. 8
    • Berger, M.J.1
  • 34
    • 0024441718 scopus 로고
    • Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations
    • A. Ahnesjö and P. Andreo, "Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations," Phys. Med. Biol. 34, 1451-1464 (1989).
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1451-1464
    • Ahnesjö, A.1    Andreo, P.2
  • 35
    • 0020567836 scopus 로고
    • The application of multiple scattering theory to therapeutic electron dosimetry
    • D. Jette, A. Pagnamenta, L. H. Lanzl, and M. Rozenfeld, "The application of multiple scattering theory to therapeutic electron dosimetry," Med. Phys. 10, 141-146 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 141-146
    • Jette, D.1    Pagnamenta, A.2    Lanzl, L.H.3    Rozenfeld, M.4
  • 36
    • 0021716880 scopus 로고
    • Restricted energy-loss straggling and multiple scattering of electrons in mixed Monte-Carlo procedures
    • P. Andreo and A. Brahme, "Restricted energy-loss straggling and multiple scattering of electrons in mixed Monte-Carlo procedures," Radiat. Res. 100, 16-29 (1984).
    • (1984) Radiat. Res. , vol.100 , pp. 16-29
    • Andreo, P.1    Brahme, A.2
  • 37
    • 0024452070 scopus 로고
    • Numerical calculation of energy deposition by broad high-energy electron beams
    • H. Huizenga and P. R. M. Storchi, "Numerical calculation of energy deposition by broad high-energy electron beams," Phys. Med. Biol. 34, 1371-1396 (1989).
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1371-1396
    • Huizenga, H.1    Storchi, P.R.M.2
  • 38
    • 0030789536 scopus 로고    scopus 로고
    • Numerical calculation of energy deposition by high-energy electron beams: III-B. Improvements to the 6D phase space evolution model
    • J. J. Janssen, E. W. Korevaar, P. R. M. Storchi, and H. Huizenga, "Numerical calculation of energy deposition by high-energy electron beams: III-B. Improvements to the 6D phase space evolution model," Phys. Med. Biol. 42, 1441-1449 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1441-1449
    • Janssen, J.J.1    Korevaar, E.W.2    Storchi, P.R.M.3    Huizenga, H.4
  • 39
    • 0027752810 scopus 로고
    • X-ray sources of medical linear accelerators: Focal and extra-focal radiation
    • D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, "X-ray sources of medical linear accelerators: Focal and extra-focal radiation," Med. Phys. 20, 1417-1427 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1417-1427
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 40
    • 0028818473 scopus 로고
    • Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams
    • M. B. Sharpe, D. A. Jaffray, J. J. Battista, and P. Munro, "Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams," Med. Phys. 22, 2065-2074 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 2065-2074
    • Sharpe, M.B.1    Jaffray, D.A.2    Battista, J.J.3    Munro, P.4
  • 41
    • 0024547608 scopus 로고
    • Telescopic measurements of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slits
    • H. Kubo, "Telescopic measurements of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slits," Med. Phys. 16, 295-298 (1989).
    • (1989) Med. Phys. , vol.16 , pp. 295-298
    • Kubo, H.1
  • 42
    • 0023678565 scopus 로고
    • Therapy imaging: Source sizes of radiotherapy beams
    • P. Munro, J. A. Rawlinson, and A. Fenster, "Therapy imaging: Source sizes of radiotherapy beams," Med. Phys. 15, 517-524 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 517-524
    • Munro, P.1    Rawlinson, J.A.2    Fenster, A.3
  • 43
    • 0027966969 scopus 로고
    • Analytical modeling of photon scatter from flattening filters in photon therapy beams
    • A. Ahnesjö, "Analytical modeling of photon scatter from flattening filters in photon therapy beams," Med. Phys. 21, 1227-1235 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1227-1235
    • Ahnesjö, A.1
  • 44
    • 0023916084 scopus 로고
    • An inverse filter for digital restoration of portal images
    • H. Meertens, M. van Herk, and J. Weeda, "An inverse filter for digital restoration of portal images," Phys. Med. Biol. 33, 687-702 (1988).
    • (1988) Phys. Med. Biol. , vol.33 , pp. 687-702
    • Meertens, H.1    Van Herk, M.2    Weeda, J.3
  • 45
    • 0025016515 scopus 로고
    • Doses on the central axes of narrow 6-MV x-ray beams
    • B. E. Bjärngard, J.-S. Tsai, and R. K. Rice, "Doses on the central axes of narrow 6-MV x-ray beams," Med. Phys. 17, 794-799 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 794-799
    • Bjärngard, B.E.1    Tsai, J.-S.2    Rice, R.K.3
  • 46
    • 85027224845 scopus 로고
    • Radiation dosimetry: Electron beams with energies between 1 and 50 MeV
    • Report 35 ICRU, Bethesda
    • Data of R. Harder in "Radiation dosimetry: Electron beams with energies between 1 and 50 MeV," International Commission on Radiation Units and Measurements, Report 35 (ICRU, Bethesda, 1984), p. 24.
    • (1984) International Commission on Radiation Units and Measurements , pp. 24
    • Harder, R.1
  • 47
    • 0029935618 scopus 로고    scopus 로고
    • Electron dose calculation using multiple-scattering theory: A new theory of multiple scattering
    • D. Jette, "Electron dose calculation using multiple-scattering theory: A new theory of multiple scattering," Med. Phys. 23, 459-477 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 459-477
    • Jette, D.1
  • 48
    • 0033054067 scopus 로고    scopus 로고
    • Photon dose calculation based on electron multiple-scattering theory: Practical representation of dose and particle transport integrals
    • D. Jette, "Photon dose calculation based on electron multiple-scattering theory: Practical representation of dose and particle transport integrals," Med. Phys. 26, 924-930 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 924-930
    • Jette, D.1
  • 49
    • 0028922435 scopus 로고
    • Collimator scatter in photon therapy beams
    • A. Ahnesjö, "Collimator scatter in photon therapy beams," Med. Phys. 22, 267-278 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 267-278
    • Ahnesjö, A.1
  • 50
    • 0032941482 scopus 로고    scopus 로고
    • A comparison of Monte Carlo and analytic first scatter dose spread arrays
    • J. E. McGary, A. L. Boyer, and T. R. Mackie, "A comparison of Monte Carlo and analytic first scatter dose spread arrays," Med. Phys. 26, 751-759 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 751-759
    • McGary, J.E.1    Boyer, A.L.2    Mackie, T.R.3
  • 51
    • 0026029087 scopus 로고
    • Bragg-Gray theory and ion chamber dosimetry for photon beams
    • C. M. Ma and A. E. Nahum, "Bragg-Gray theory and ion chamber dosimetry for photon beams," Phys. Med. Biol. 36, 413-426 (1991).
    • (1991) Phys. Med. Biol. , vol.36 , pp. 413-426
    • Ma, C.M.1    Nahum, A.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.