메뉴 건너뛰기




Volumn 35, Issue 9, 2003, Pages 1138-1148

Novel particulate spin probe for targeted determination of oxygen in cells and tissues

Author keywords

Electron paramagnetic resonance; Free radical; Naphthalocyanine; Oximetry; Particulate; RIF 1 tumor; Spin probe

Indexed keywords

OXYGEN; RADICAL;

EID: 0142231339     PISSN: 08915849     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0891-5849(03)00496-9     Document Type: Article
Times cited : (137)

References (43)
  • 1
    • 0038317943 scopus 로고    scopus 로고
    • Hemoglobin solutions and tissue oxygenation
    • Muir W.W., Wellman M.L. Hemoglobin solutions and tissue oxygenation. J. Vet. Intern. Med. 17:2003;127-135.
    • (2003) J. Vet. Intern. Med. , vol.17 , pp. 127-135
    • Muir, W.W.1    Wellman, M.L.2
  • 5
    • 0031964711 scopus 로고    scopus 로고
    • The relationship between tumour oxygenation determined by oxygen electrode measurements and magnetic resonance spectroscopy of the fluorinated 2-nitroimidazole SR-4554
    • Aboagye E.O., Maxwell R.J., Horsman M.R., Lewis A.D., Workman P., Tracy M., Griffiths J.R. The relationship between tumour oxygenation determined by oxygen electrode measurements and magnetic resonance spectroscopy of the fluorinated 2-nitroimidazole SR-4554. Br. J. Cancer. 77:1998;65-70.
    • (1998) Br. J. Cancer , vol.77 , pp. 65-70
    • Aboagye, E.O.1    Maxwell, R.J.2    Horsman, M.R.3    Lewis, A.D.4    Workman, P.5    Tracy, M.6    Griffiths, J.R.7
  • 6
    • 0030453790 scopus 로고    scopus 로고
    • Noninvasive evaluation of intrarenal oxygenation with BOLD MRI
    • Prasad P.V., Edelman R.R., Epstein F.H. Noninvasive evaluation of intrarenal oxygenation with BOLD MRI. Circulation. 94:1996;3271-3275.
    • (1996) Circulation , vol.94 , pp. 3271-3275
    • Prasad, P.V.1    Edelman, R.R.2    Epstein, F.H.3
  • 7
    • 0029658470 scopus 로고    scopus 로고
    • Hexafluorobenzene: A sensitive 19F NMR indicator of tumor oxygenation
    • Mason R.P., Rodbumrung W., Antich P.P. Hexafluorobenzene a sensitive 19F NMR indicator of tumor oxygenation . NMR Biomed. 9:1996;125-134.
    • (1996) NMR Biomed , vol.9 , pp. 125-134
    • Mason, R.P.1    Rodbumrung, W.2    Antich, P.P.3
  • 12
    • 0031842960 scopus 로고    scopus 로고
    • The measurement of oxygen in vivo using EPR techniques
    • Swartz H.M., Clarkson R.B. The measurement of oxygen in vivo using EPR techniques. Phys. Med. Biol. 43:1998;1957-1975.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1957-1975
    • Swartz, H.M.1    Clarkson, R.B.2
  • 13
    • 0035822206 scopus 로고    scopus 로고
    • Electrochemical preparation and EPR studies of lithium phthalocyanine. 3. Measurements of oxygen concentration in tissues and biochemical reactions
    • Ilangovan G., Li H., Zweier J.L., Kuppusamy P. Electrochemical preparation and EPR studies of lithium phthalocyanine. 3. Measurements of oxygen concentration in tissues and biochemical reactions. J. Phys. Chem. B. 105:2001;5323-5330.
    • (2001) J. Phys. Chem. B , vol.105 , pp. 5323-5330
    • Ilangovan, G.1    Li, H.2    Zweier, J.L.3    Kuppusamy, P.4
  • 16
    • 0037382342 scopus 로고    scopus 로고
    • Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): Methodology and comparison with blood oxygen level-dependent (BOLD) MRI
    • Elas M., Williams B.B., Parasca A., Mailer C., Pelizzari C.A., Lewis M.A., River J.N., Karczmar G.S., Barth E.D., Halpern H.J. Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI) methodology and comparison with blood oxygen level-dependent (BOLD) MRI . Magn. Reson. Med. 49:2003;682-691.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 682-691
    • Elas, M.1    Williams, B.B.2    Parasca, A.3    Mailer, C.4    Pelizzari, C.A.5    Lewis, M.A.6    River, J.N.7    Karczmar, G.S.8    Barth, E.D.9    Halpern, H.J.10
  • 18
    • 0030745623 scopus 로고    scopus 로고
    • Gloxy: An oxygen-sensitive coal for accurate measurement of low oxygen tensions in biological systems
    • James P.E., Grinberg O.Y., Goda F., Panz T., O'Hara J.A., Swartz H.M. Gloxy an oxygen-sensitive coal for accurate measurement of low oxygen tensions in biological systems . Magn. Reson. Med. 38:1997;48-58.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 48-58
    • James, P.E.1    Grinberg, O.Y.2    Goda, F.3    Panz, T.4    O'Hara, J.A.5    Swartz, H.M.6
  • 21
    • 0001167984 scopus 로고    scopus 로고
    • Electrochemical preparation and EPR studies of lithium phthalocyanine: Evaluation of the nucleation and growth mechanism and evidence for potential-dependent phase formation
    • Ilangovan G., Zweier J.L., Kuppusamy P. Electrochemical preparation and EPR studies of lithium phthalocyanine evaluation of the nucleation and growth mechanism and evidence for potential-dependent phase formation . J. Phys. Chem. B. 104:2000;4047-4059.
    • (2000) J. Phys. Chem. B , vol.104 , pp. 4047-4059
    • Ilangovan, G.1    Zweier, J.L.2    Kuppusamy, P.3
  • 22
    • 0034299240 scopus 로고    scopus 로고
    • Electrochemical preparation and EPR studies of lithium phthalocyanine. Part 2: Particle-size-dependent line broadening by molecular oxygen and its implications as an oximetry probe
    • Ilangovan G., Zweier J.L., Kuppusamy P. Electrochemical preparation and EPR studies of lithium phthalocyanine. Part 2 Particle-size-dependent line broadening by molecular oxygen and its implications as an oximetry probe . J. Phys. Chem. B. 104:2000;9404-9410.
    • (2000) J. Phys. Chem. B , vol.104 , pp. 9404-9410
    • Ilangovan, G.1    Zweier, J.L.2    Kuppusamy, P.3
  • 23
    • 0035425781 scopus 로고    scopus 로고
    • Lithium naphthalocyanine as a new molecular radical probe for electron paramagnetic resonance oximetry
    • Manivannan A., Yanagi H., Ilangovan G., Kuppusamy P. Lithium naphthalocyanine as a new molecular radical probe for electron paramagnetic resonance oximetry. J. Magn. Magn. Mater. 233:2001;L131-L135.
    • (2001) J. Magn. Magn. Mater. , vol.233
    • Manivannan, A.1    Yanagi, H.2    Ilangovan, G.3    Kuppusamy, P.4
  • 24
    • 4243905937 scopus 로고
    • Preparation and study of a lithium phthalocyanine radical - optical and magnetic - properties
    • Turek P., Andre J.J., Giraudeau A., Simon J. Preparation and study of a lithium phthalocyanine radical - optical and magnetic - properties. Chem. Phys. Lett. 134:1987;471-476.
    • (1987) Chem. Phys. Lett. , vol.134 , pp. 471-476
    • Turek, P.1    Andre, J.J.2    Giraudeau, A.3    Simon, J.4
  • 25
    • 0032426610 scopus 로고    scopus 로고
    • Superparamagnetic agents in magnetic resonance imaging: Physicochemical characteristics and clinical applications. A review
    • Bonnemain B. Superparamagnetic agents in magnetic resonance imaging physicochemical characteristics and clinical applications. A review . J. Drug Target. 6:1998;167-174.
    • (1998) J. Drug Target. , vol.6 , pp. 167-174
    • Bonnemain, B.1
  • 26
    • 0034753215 scopus 로고    scopus 로고
    • Superparamagnetic iron oxide contrast agents: Physicochemical characteristics and applications in MR imaging
    • Wang Y.X., Hussain S.M., Krestin G.P. Superparamagnetic iron oxide contrast agents physicochemical characteristics and applications in MR imaging . Eur. Radiol. 11:2001;2319-2331.
    • (2001) Eur. Radiol. , vol.11 , pp. 2319-2331
    • Wang, Y.X.1    Hussain, S.M.2    Krestin, G.P.3
  • 27
    • 0036333722 scopus 로고    scopus 로고
    • Magnetic intracellular labeling of mammalian cells by combining (FDA-approved) superparamagnetic iron oxide MR contrast agents and commonly used transfection agents
    • Frank J.A., Zywicke H., Jordan E.K., Mitchell J., Lewis B.K., Miller B., Bryant L.H. Jr., Bulte J.W. Magnetic intracellular labeling of mammalian cells by combining (FDA-approved) superparamagnetic iron oxide MR contrast agents and commonly used transfection agents. Acad. Radiol. 9:(Suppl. 2):2002;S484-S487.
    • (2002) Acad. Radiol. , vol.9 , Issue.SUPPL. 2
    • Frank, J.A.1    Zywicke, H.2    Jordan, E.K.3    Mitchell, J.4    Lewis, B.K.5    Miller, B.6    Bryant L.H., Jr.7    Bulte, J.W.8
  • 30
    • 0028055081 scopus 로고
    • In vivo and in vitro EPR oximetry with fusinite: A new coal-derived, particulate EPR probe
    • Vahidi N., Clarkson R.B., Liu K.J., Norby S.W., Wu M., Swartz H.M. In vivo and in vitro EPR oximetry with fusinite a new coal-derived, particulate EPR probe . Magn. Reson. Med. 31:1994;139-146.
    • (1994) Magn. Reson. Med. , vol.31 , pp. 139-146
    • Vahidi, N.1    Clarkson, R.B.2    Liu, K.J.3    Norby, S.W.4    Wu, M.5    Swartz, H.M.6
  • 31
    • 0031813015 scopus 로고    scopus 로고
    • Small particles of fusinite and carbohydrate chars coated with aqueous soluble polymers: Preparation and applications for in vivo EPR oximetry
    • Gallez B., Debuyst R., Dejehet F., Liu K.J., Walczak T., Goda F., Demeure R., Taper H., Swartz H.M. Small particles of fusinite and carbohydrate chars coated with aqueous soluble polymers preparation and applications for in vivo EPR oximetry . Magn. Reson. Med. 40:1998;152-159.
    • (1998) Magn. Reson. Med. , vol.40 , pp. 152-159
    • Gallez, B.1    Debuyst, R.2    Dejehet, F.3    Liu, K.J.4    Walczak, T.5    Goda, F.6    Demeure, R.7    Taper, H.8    Swartz, H.M.9
  • 32
    • 0028504460 scopus 로고
    • Development of a highly sensitive probe for measuring oxygen in biological tissues
    • Zweier J.L., Chzhan M., Ewert U., Schneider G., Kuppusamy P. Development of a highly sensitive probe for measuring oxygen in biological tissues. J. Magn. Reson. B. 105:1994;52-57.
    • (1994) J. Magn. Reson. B , vol.105 , pp. 52-57
    • Zweier, J.L.1    Chzhan, M.2    Ewert, U.3    Schneider, G.4    Kuppusamy, P.5
  • 35
    • 0032765504 scopus 로고    scopus 로고
    • Microencapsulation of paramagnetic particles by pyrroxylin to preserve their responsiveness to oxygen when used as sensors for in vivo EPR oximetry
    • Gallez B., Jordan B.F., Baudelet C. Microencapsulation of paramagnetic particles by pyrroxylin to preserve their responsiveness to oxygen when used as sensors for in vivo EPR oximetry. Magn. Reson. Med. 42:1999;193-196.
    • (1999) Magn. Reson. Med. , vol.42 , pp. 193-196
    • Gallez, B.1    Jordan, B.F.2    Baudelet, C.3
  • 37
    • 0032134081 scopus 로고    scopus 로고
    • Separation and enrichment of the active component of carbon-based paramagnetic materials for use in EPR oximetry
    • Liu K.J., Miyake M., James P.E., Swartz H.M. Separation and enrichment of the active component of carbon-based paramagnetic materials for use in EPR oximetry. J. Magn. Reson. 133:1998;291-298.
    • (1998) J. Magn. Reson. , vol.133 , pp. 291-298
    • Liu, K.J.1    Miyake, M.2    James, P.E.3    Swartz, H.M.4
  • 39
    • 0034846109 scopus 로고    scopus 로고
    • Development of biocompatible oxygen-permeable films holding paramagnetic carbon particles: Evaluation of their performance and stability in EPR oximetry
    • He J., Beghein N., Ceroke P., Clarkson R.B., Swartz H.M., Gallez B. Development of biocompatible oxygen-permeable films holding paramagnetic carbon particles evaluation of their performance and stability in EPR oximetry . Magn. Reson. Med. 46:2001;610-614.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 610-614
    • He, J.1    Beghein, N.2    Ceroke, P.3    Clarkson, R.B.4    Swartz, H.M.5    Gallez, B.6
  • 40
    • 0035739929 scopus 로고    scopus 로고
    • Microencapsulation of carbon particles used as oxygen sensors in EPR oximetry to stabilize their responsiveness to oxygen in vitro and in vivo
    • Jiang H., Beghei N., Clarkson R.B., Swartz H.M., Galle B. Microencapsulation of carbon particles used as oxygen sensors in EPR oximetry to stabilize their responsiveness to oxygen in vitro and in vivo. Phys. Med. Biol. 46:2001;3323-3329.
    • (2001) Phys. Med. Biol. , vol.46 , pp. 3323-3329
    • Jiang, H.1    Beghei, N.2    Clarkson, R.B.3    Swartz, H.M.4    Galle, B.5
  • 43
    • 0036240494 scopus 로고    scopus 로고
    • Ultrasmall superparamagnetic iron oxide-enhanced MR imaging of atherosclerotic plaque in hyperlipidemic rabbits
    • Ruehm S.G., Corot C., Vogt P., Cristina H., Debatin J.F. Ultrasmall superparamagnetic iron oxide-enhanced MR imaging of atherosclerotic plaque in hyperlipidemic rabbits. Acad. Radiol. 9:(Suppl. 1):2002;S143-S144.
    • (2002) Acad. Radiol. , vol.9 , Issue.SUPPL. 1
    • Ruehm, S.G.1    Corot, C.2    Vogt, P.3    Cristina, H.4    Debatin, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.