Oral Anticoagulant Monitoring by Laboratory or Near-Patient Testing: What a Clinician Should Be Aware Of

Author keywords

International Normalized Ratio; Near patient testing; Oral anticoagulation

Indexed keywords

ANTICOAGULANT AGENT; CITRATE SODIUM; HEPARIN; LUPUS ANTICOAGULANT;

EID: 0142040248     PISSN: 15289648     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-44460     Document Type: Review
Times cited : (15)

References (54)
  • 1
    • 0035128503 scopus 로고    scopus 로고
    • Oral anticoagulants: Mechanism of action, clinical effectiveness, and optimal therapeutic range
    • Hirsh J, Dalen JE, Anderson DR, Poller L, Bussey H, Ansell J, Deykin D. Oral anticoagulants: mechanism of action, clinical effectiveness, and optimal therapeutic range. Chest 2001;119:8S-21S
    • (2001) Chest , vol.119
    • Hirsh, J.1    Dalen, J.E.2    Anderson, D.R.3    Poller, L.4    Bussey, H.5    Ansell, J.6    Deykin, D.7
  • 2
    • 0003940062 scopus 로고    scopus 로고
    • Guidelines for thromboplastins and plasma used to monitor oral anticoagulant therapy
    • WHO Expert Committee on Biological Standardization. Guidelines for thromboplastins and plasma used to monitor oral anticoagulant therapy. World Health Organization Technical Report Series, 1999; No. 889
    • (1999) World Health Organization Technical Report Series , vol.889
  • 3
    • 0032919783 scopus 로고    scopus 로고
    • Influence of three types of automated coagulometers on the international sensitivity index (ISI) of rabbit, human and recombinant human tissue factor preparations
    • van den Besselaar AMHP, Aillaud MF, Denson KWE, et al. Influence of three types of automated coagulometers on the international sensitivity index (ISI) of rabbit, human and recombinant human tissue factor preparations. Thromb Haemost 1999;81:66-70
    • (1999) Thromb Haemost , vol.81 , pp. 66-70
    • Van den Besselaar, A.M.H.P.1    Aillaud, M.F.2    Denson, K.W.E.3
  • 4
    • 0031756878 scopus 로고    scopus 로고
    • The European Concerted Action on Anticoagulation (ECAA): Field studies of coagulometers effects on the ISI of ECAA thromboplastins
    • Poller L, van den Besselaar AMHP, Jespersen J, Tripodi A, Houghton D. The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometers effects on the ISI of ECAA thromboplastins. Thromb Haemost 1998;80:615-623
    • (1998) Thromb Haemost , vol.80 , pp. 615-623
    • Poller, L.1    Van den Besselaar, A.M.H.P.2    Jespersen, J.3    Tripodi, A.4    Houghton, D.5
  • 5
    • 0030205037 scopus 로고    scopus 로고
    • Reliability of the international normalized ratio for monitoring the induction phase of warfarin: Comparison with the prothrombin time ratio
    • Johnston M, Harrison L, Moffat K, Willan A, Hirsh J. Reliability of the international normalized ratio for monitoring the induction phase of warfarin: comparison with the prothrombin time ratio. J Lab Clin Med 1996;128:214-217
    • (1996) J Lab Clin Med , vol.128 , pp. 214-217
    • Johnston, M.1    Harrison, L.2    Moffat, K.3    Willan, A.4    Hirsh, J.5
  • 7
    • 0027209887 scopus 로고
    • Enzymatic elimination of heparin from plasma for activated partial thromboplastin time and prothrombin time testing
    • van den Besselaar AMHP, Meeuwisse-Braun J. Enzymatic elimination of heparin from plasma for activated partial thromboplastin time and prothrombin time testing. Blood Coag Fibrinol 1993;4:635-638
    • (1993) Blood Coag Fibrinol , vol.4 , pp. 635-638
    • Van den Besselaar, A.M.H.P.1    Meeuwisse-Braun, J.2
  • 8
    • 0033030452 scopus 로고    scopus 로고
    • The risk of heparin-neutralizing substances
    • Tripodi A. The risk of heparin-neutralizing substances. Am J Clin Pathol 1999;111:566
    • (1999) Am J Clin Pathol , vol.111 , pp. 566
    • Tripodi, A.1
  • 9
    • 0029813875 scopus 로고    scopus 로고
    • Potential failure of the international normalized ratio (INR) system in the monitoring of oral anticoagulation in patients with lupus anticoagulants
    • Della Valle P, Crippa L, Safa O, et al. Potential failure of the international normalized ratio (INR) system in the monitoring of oral anticoagulation in patients with lupus anticoagulants. Ann Med Intern 1996;147:10-14
    • (1996) Ann Med Intern , vol.147 , pp. 10-14
    • Della Valle, P.1    Crippa, L.2    Safa, O.3
  • 10
    • 0031203621 scopus 로고    scopus 로고
    • Monitoring warfarin therapy in patients with lupus anticoagulants
    • Moll S, Ortel TL. Monitoring warfarin therapy in patients with lupus anticoagulants. Ann Intern Med 1997;127:177-185
    • (1997) Ann Intern Med , vol.127 , pp. 177-185
    • Moll, S.1    Ortel, T.L.2
  • 11
    • 0030802660 scopus 로고    scopus 로고
    • Monitoring oral anticoagulation therapy in lupus anticoagulant positive patients with the anti-phospholipid syndrome
    • Lawrie AS, Purdy G, Mackie IJ, Machin SJ. Monitoring oral anticoagulation therapy in lupus anticoagulant positive patients with the anti-phospholipid syndrome. Br J Haematol 1997;98:887-892
    • (1997) Br J Haematol , vol.98 , pp. 887-892
    • Lawrie, A.S.1    Purdy, G.2    Mackie, I.J.3    Machin, S.J.4
  • 12
    • 0031927812 scopus 로고    scopus 로고
    • Control of oral anticoagulation in patients with the antiphospholipid syndrome. Influence of the lupus anticoagulant on international normalized ratio
    • Robert A, Le Querrec A, Delahousse B, et al. Control of oral anticoagulation in patients with the antiphospholipid syndrome. Influence of the lupus anticoagulant on international normalized ratio. Thromb Haemost 1998;80:99-103
    • (1998) Thromb Haemost , vol.80 , pp. 99-103
    • Robert, A.1    Le Querrec, A.2    Delahousse, B.3
  • 13
    • 0035669154 scopus 로고    scopus 로고
    • Laboratory control of oral anticoagulant treatment by the INR system in patients with the antiphospholipid syndrome and lupus anticoagulant. Results of a collaborative study involving nine commercial thromboplastins
    • Tripodi A, Chantarangkul V, Clerici M, Negri B, Galli M, Mannucci PM. Laboratory control of oral anticoagulant treatment by the INR system in patients with the antiphospholipid syndrome and lupus anticoagulant. Results of a collaborative study involving nine commercial thromboplastins. Br J Haematol 2001;115:672-678
    • (2001) Br J Haematol , vol.115 , pp. 672-678
    • Tripodi, A.1    Chantarangkul, V.2    Clerici, M.3    Negri, B.4    Galli, M.5    Mannucci, P.M.6
  • 14
    • 0029638718 scopus 로고
    • Thrombosis in the antiphospholipid antibody syndrome
    • Rapaport SI, Le DT. Thrombosis in the antiphospholipid antibody syndrome. N Engl J Med 1995;333:665
    • (1995) N Engl J Med , vol.333 , pp. 665
    • Rapaport, S.I.1    Le, D.T.2
  • 15
    • 0028929209 scopus 로고
    • International Normalized Ratio for prothrombin times in patients taking oral anticoagulants: Critical difference and probability of significant change in consecutive measurements
    • Lassen JF, Brandslund I, Antonsen S. International Normalized Ratio for prothrombin times in patients taking oral anticoagulants: critical difference and probability of significant change in consecutive measurements. Clin Chem 1995;41:444-447
    • (1995) Clin Chem , vol.41 , pp. 444-447
    • Lassen, J.F.1    Brandslund, I.2    Antonsen, S.3
  • 16
    • 18144435505 scopus 로고
    • Concentration of citrate anticoagulant
    • Jacobs P. Concentration of citrate anticoagulant. Am J Clin Pathol 1973;60:941
    • (1973) Am J Clin Pathol , vol.60 , pp. 941
    • Jacobs, P.1
  • 17
    • 0031851147 scopus 로고    scopus 로고
    • Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations
    • Chantarangkul V, Tripodi A, Clerici M, Negri B, Mannucci PM. Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations. Thromb Haemost 1998;80:258-262
    • (1998) Thromb Haemost , vol.80 , pp. 258-262
    • Chantarangkul, V.1    Tripodi, A.2    Clerici, M.3    Negri, B.4    Mannucci, P.M.5
  • 18
    • 0034897663 scopus 로고    scopus 로고
    • The clinical relevance of the citrate effect on International Normalized Ratio determinations depends on the reagent and instrument combination used
    • Lottin L, Woodhams BJ, Saureau MC, Robert A, Aillaud MF, Arnaud E, Martinoli JL. The clinical relevance of the citrate effect on International Normalized Ratio determinations depends on the reagent and instrument combination used. Blood Coagul Fibrinolysis 2001;12:399-404
    • (2001) Blood Coagul Fibrinolysis , vol.12 , pp. 399-404
    • Lottin, L.1    Woodhams, B.J.2    Saureau, M.C.3    Robert, A.4    Aillaud, M.F.5    Arnaud, E.6    Martinoli, J.L.7
  • 19
    • 0033782634 scopus 로고    scopus 로고
    • A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination
    • van den Besselaar AMHP, Chantarangkul V, Tripodi A. A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination. Thromb Haemost 2000;84:664-667
    • (2000) Thromb Haemost , vol.84 , pp. 664-667
    • Van den Besselaar, A.M.H.P.1    Chantarangkul, V.2    Tripodi, A.3
  • 20
    • 0035067666 scopus 로고    scopus 로고
    • Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes
    • van den Besselaar AMHP, van Dam W, Sturk A, Bertina RM. Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes. Thromb Haemost 2001;85:647-650
    • (2001) Thromb Haemost , vol.85 , pp. 647-650
    • Van den Besselaar, A.M.H.P.1    Van Dam, W.2    Sturk, A.3    Bertina, R.M.4
  • 21
    • 0030816280 scopus 로고    scopus 로고
    • Effect of sample storage on the International Normalized Ratio
    • Vadher BD, Lloyd M, Parker N, Patterson DLH. Effect of sample storage on the International Normalized Ratio. Br J Haematol 1997;97:936-937
    • (1997) Br J Haematol , vol.97 , pp. 936-937
    • Vadher, B.D.1    Lloyd, M.2    Parker, N.3    Patterson, D.L.H.4
  • 22
    • 0030884920 scopus 로고    scopus 로고
    • Refrigerated stored specimens are not reliable for delayed INR determination
    • Hernández AG, Martín de Segovia JM, Villanueva JR. Refrigerated stored specimens are not reliable for delayed INR determination. Br J Haematol 1997;98:781-782
    • (1997) Br J Haematol , vol.98 , pp. 781-782
    • Hernández, A.G.1    Martín de Segovia, J.M.2    Villanueva, J.R.3
  • 23
    • 0035723522 scopus 로고    scopus 로고
    • Reliability of delayed prothrombin time INR determinations in a central laboratory using off-site blood sampling
    • Froom P, Abramova D, Bar-El M, Barak M. Reliability of delayed prothrombin time INR determinations in a central laboratory using off-site blood sampling. Clin Lab Haematol 2001;23:189-192
    • (2001) Clin Lab Haematol , vol.23 , pp. 189-192
    • Froom, P.1    Abramova, D.2    Bar-El, M.3    Barak, M.4
  • 24
    • 0031029431 scopus 로고    scopus 로고
    • Reliability of delayed INR determination: Implications for decentralized anticoagulant care with off-site blood sampling
    • Baglin T, Luddington R. Reliability of delayed INR determination: implications for decentralized anticoagulant care with off-site blood sampling. Br J Haematol 1997;96:431-434
    • (1997) Br J Haematol , vol.96 , pp. 431-434
    • Baglin, T.1    Luddington, R.2
  • 25
    • 0030793727 scopus 로고    scopus 로고
    • Prothrombin time determination. The lack of need for a discard tube and 24-hour stability
    • Brigden ML, Graydon C, McLeod B, Lesperance M. Prothrombin time determination. The lack of need for a discard tube and 24-hour stability. Am J Clin Pathol 1997;108:422-426
    • (1997) Am J Clin Pathol , vol.108 , pp. 422-426
    • Brigden, M.L.1    Graydon, C.2    McLeod, B.3    Lesperance, M.4
  • 26
    • 0032445781 scopus 로고    scopus 로고
    • Laboratory control of oral anticoagulant therapy: Preservation of prothrombin time specimens using a polypropylene collection system
    • Ridyard J, Bhavnani M, Seal LH. Laboratory control of oral anticoagulant therapy: preservation of prothrombin time specimens using a polypropylene collection system. Clin Lab Haematol 1998;20:369-372
    • (1998) Clin Lab Haematol , vol.20 , pp. 369-372
    • Ridyard, J.1    Bhavnani, M.2    Seal, L.H.3
  • 29
    • 0032887627 scopus 로고    scopus 로고
    • The effects of freeze drying and freeze drying additives on the prothrombin time and the international sensitivity index
    • Poller L, Keown M, Shepherd SA, Shiach CR, Tabeart S. The effects of freeze drying and freeze drying additives on the prothrombin time and the international sensitivity index. J Clin Pathol 1999;52:744-748
    • (1999) J Clin Pathol , vol.52 , pp. 744-748
    • Poller, L.1    Keown, M.2    Shepherd, S.A.3    Shiach, C.R.4    Tabeart, S.5
  • 30
    • 0029954530 scopus 로고    scopus 로고
    • Precision and accuracy of the International Normalized Ratio in oral anticoagulant control
    • van den Besselaar AMHP. Precision and accuracy of the International Normalized Ratio in oral anticoagulant control. Haemostasis 1996;26:248-265
    • (1996) Haemostasis , vol.26 , pp. 248-265
    • Van den Besselaar, A.M.H.P.1
  • 31
    • 0029087918 scopus 로고
    • Quality control and oral anticoagulation
    • Preston FE. Quality control and oral anticoagulation. Thromb Haemost 1995;74:515-520
    • (1995) Thromb Haemost , vol.74 , pp. 515-520
    • Preston, F.E.1
  • 32
    • 0030919953 scopus 로고    scopus 로고
    • Field study of lyophilised plasmas for local prothrombin time calibration in the Netherlands
    • van den Besselaar AMHP. Field study of lyophilised plasmas for local prothrombin time calibration in the Netherlands. J Clin Pathol 1997;50:371-374
    • (1997) J Clin Pathol , vol.50 , pp. 371-374
    • Van den Besselaar, A.M.H.P.1
  • 33
    • 0021923839 scopus 로고
    • Reliability and clinical impact of the normalization of the prothrombin times in oral anticoagulant control
    • Loeliger EA, van den Besselaar AMHP, Lewis SM. Reliability and clinical impact of the normalization of the prothrombin times in oral anticoagulant control. Thromb Haemost 1985;53:148-154
    • (1985) Thromb Haemost , vol.53 , pp. 148-154
    • Loeliger, E.A.1    Van den Besselaar, A.M.H.P.2    Lewis, S.M.3
  • 34
    • 0001822493 scopus 로고
    • A statistician's independent evaluation
    • van den Besselaar AMHP, Gralnick HR, Lewis SM, eds. Boston, MA: Martinus Nijhoff
    • Tomenson JA. A statistician's independent evaluation. In: van den Besselaar AMHP, Gralnick HR, Lewis SM, eds. Thromboplastin Calibration and Oral Anticoagulant Control. Boston, MA: Martinus Nijhoff; 1984:87-108
    • (1984) Thromboplastin Calibration and Oral Anticoagulant Control , pp. 87-108
    • Tomenson, J.A.1
  • 36
    • 0029558873 scopus 로고
    • Designing a point-of-care program for coagulation testing
    • Macik BG. Designing a point-of-care program for coagulation testing. Arch Pathol Lab Med 1995;119:929-938
    • (1995) Arch Pathol Lab Med , vol.119 , pp. 929-938
    • Macik, B.G.1
  • 37
    • 0030844741 scopus 로고    scopus 로고
    • Evaluation of bedside prothrombin time and activated partial thromboplastin time measurement by coagulation analyzer CoaguChek Plus® in various clinical settings
    • Ruzicka K, Kapiotis S, Quehenberger P, et al. Evaluation of bedside prothrombin time and activated partial thromboplastin time measurement by coagulation analyzer CoaguChek Plus® in various clinical settings. Thromb Res 1997;87:431-440
    • (1997) Thromb Res , vol.87 , pp. 431-440
    • Ruzicka, K.1    Kapiotis, S.2    Quehenberger, P.3
  • 38
    • 0030783773 scopus 로고    scopus 로고
    • Monitoring oral anticoagulant treatment with the TAS near-patient test system: Comparison with conventional thromboplastins
    • Kitchen S, Preston FE. Monitoring oral anticoagulant treatment with the TAS near-patient test system: comparison with conventional thromboplastins. J Clin Pathol 1997;50:951-956
    • (1997) J Clin Pathol , vol.50 , pp. 951-956
    • Kitchen, S.1    Preston, F.E.2
  • 39
    • 0029585825 scopus 로고
    • Multicenter evaluation of a new capillary blood prothrombin time monitoring system
    • van den Besselaar AMHP, Breddin K, Lutze G, et al. Multicenter evaluation of a new capillary blood prothrombin time monitoring system. Blood Coagul Fibrinolysis 1995;6:726-732
    • (1995) Blood Coagul Fibrinolysis , vol.6 , pp. 726-732
    • Van den Besselaar, A.M.H.P.1    Breddin, K.2    Lutze, G.3
  • 40
    • 0035126113 scopus 로고    scopus 로고
    • Point-of-care prothrombin time measurement for professional and patient self-testing use
    • Andrew M, Ansell JL, Becker DM, et al. Point-of-care prothrombin time measurement for professional and patient self-testing use. Am J Clin Pathol 2001;115:288-296
    • (2001) Am J Clin Pathol , vol.115 , pp. 288-296
    • Andrew, M.1    Ansell, J.L.2    Becker, D.M.3
  • 41
    • 0030152766 scopus 로고    scopus 로고
    • Membrane-based, dry-reagent prothrombin time tests
    • Zweig SE, Meyer BG, Sharma S, et al. Membrane-based, dry-reagent prothrombin time tests. Biomed Instrum Technol 1996;30:245-256
    • (1996) Biomed Instrum Technol , vol.30 , pp. 245-256
    • Zweig, S.E.1    Meyer, B.G.2    Sharma, S.3
  • 42
    • 0027724308 scopus 로고
    • Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the International Normalized Ratio?
    • Tripodi A, Arbini AA, Chantarangkul V, et al. Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the International Normalized Ratio? Thromb Haemost 1993;70:921-924
    • (1993) Thromb Haemost , vol.70 , pp. 921-924
    • Tripodi, A.1    Arbini, A.A.2    Chantarangkul, V.3
  • 43
    • 0034932621 scopus 로고    scopus 로고
    • Near-patient testing devices to monitor oral anticoagulant therapy
    • Tripodi A, Chantarangkul V, Mannucci PM. Near-patient testing devices to monitor oral anticoagulant therapy. Br J Haematol 2001;113:847-852
    • (2001) Br J Haematol , vol.113 , pp. 847-852
    • Tripodi, A.1    Chantarangkul, V.2    Mannucci, P.M.3
  • 44
    • 0036120927 scopus 로고    scopus 로고
    • European Concerted Action on Anticoagulation (ECAA): Multicentre international sensitivity index calibration of two types of point-of-care prothrombin time monitor systems
    • Poller L, Keown M, Chauhan N, et al. European Concerted Action on Anticoagulation (ECAA): multicentre international sensitivity index calibration of two types of point-of-care prothrombin time monitor systems. Br J Haematol 2002;116:844-850
    • (2002) Br J Haematol , vol.116 , pp. 844-850
    • Poller, L.1    Keown, M.2    Chauhan, N.3
  • 45
    • 0032535316 scopus 로고    scopus 로고
    • Precision of patients' measurements of the international normalized ratio (INR) using a patient operated whole blood home coagulometer
    • Attermann J, Kynde K, Hasenkam JM. Precision of patients' measurements of the international normalized ratio (INR) using a patient operated whole blood home coagulometer. Thromb Res 1998;92:287-291
    • (1998) Thromb Res , vol.92 , pp. 287-291
    • Attermann, J.1    Kynde, K.2    Hasenkam, J.M.3
  • 46
    • 0032938443 scopus 로고    scopus 로고
    • State-of-the-art patient self-management for control of oral anticoagulation
    • Taborski U, Müller-Berghaus G. State-of-the-art patient self-management for control of oral anticoagulation. Semin Thromb Hemost 1999;25:43-47
    • (1999) Semin Thromb Hemost , vol.25 , pp. 43-47
    • Taborski, U.1    Müller-Berghaus, G.2
  • 47
    • 0036093794 scopus 로고    scopus 로고
    • Accuracy and precision of the CoaguChek S versus laboratory INRs in a clinic
    • Havrda DE, Hawk TL, Marvin CM. Accuracy and precision of the CoaguChek S versus laboratory INRs in a clinic. Ann Pharmacother 2002;36:769-774
    • (2002) Ann Pharmacother , vol.36 , pp. 769-774
    • Havrda, D.E.1    Hawk, T.L.2    Marvin, C.M.3
  • 48
    • 0035189316 scopus 로고    scopus 로고
    • Accuracy, precision, and quality control for point-of-care testing of oral anticoagulation
    • van den Besselaar AMHP. Accuracy, precision, and quality control for point-of-care testing of oral anticoagulation. J Thromb Thrombolysis 2001;12:35-40
    • (2001) J Thromb Thrombolysis , vol.12 , pp. 35-40
    • Van den Besselaar, A.M.H.P.1
  • 49
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995;346:1085-1087
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 50
    • 0034066662 scopus 로고    scopus 로고
    • A comparison of point-of-care instruments designed for monitoring oral anticoagulation with standard laboratory methods
    • Gosselin R, Owings JT, White RH, et al. A comparison of point-of-care instruments designed for monitoring oral anticoagulation with standard laboratory methods. Thromb Haemost 2000;83:698-703
    • (2000) Thromb Haemost , vol.83 , pp. 698-703
    • Gosselin, R.1    Owings, J.T.2    White, R.H.3
  • 51
    • 0033997993 scopus 로고    scopus 로고
    • Comparison between routine laboratory prothrombin time measurements and fingerstick determinations using a near-patient testing device (Pro-Time®)
    • Biasiolo A, Rampazzo P, Furnari O, Filippi B, Pengo V. Comparison between routine laboratory prothrombin time measurements and fingerstick determinations using a near-patient testing device (Pro-Time®). Thromb Res 2000;97:495-498
    • (2000) Thromb Res , vol.97 , pp. 495-498
    • Biasiolo, A.1    Rampazzo, P.2    Furnari, O.3    Filippi, B.4    Pengo, V.5
  • 52
    • 0031662868 scopus 로고    scopus 로고
    • College of American Pathologists Conference XXXI on laboratory monitoring of anticoagulant therapy. Laboratory monitoring of oral anticoagulant therapy
    • Fairweather RB, Ansell J, van den Besselaar AMHP, et al. College of American Pathologists Conference XXXI on laboratory monitoring of anticoagulant therapy. Laboratory monitoring of oral anticoagulant therapy. Arch Pathol Lab Med 1998;122:768-781
    • (1998) Arch Pathol Lab Med , vol.122 , pp. 768-781
    • Fairweather, R.B.1    Ansell, J.2    Van den Besselaar, A.M.H.P.3
  • 53
    • 0032930901 scopus 로고    scopus 로고
    • Training of patients for self-management of oral anticoagulant therapy: Standards, patient suitability, and clinical aspects
    • Mörsdorf S, Erdlenbruch W, Taborski U, et al. Training of patients for self-management of oral anticoagulant therapy: standards, patient suitability, and clinical aspects. Semin Thromb Hemost 1999;25:109-115
    • (1999) Semin Thromb Hemost , vol.25 , pp. 109-115
    • Mörsdorf, S.1    Erdlenbruch, W.2    Taborski, U.3
  • 54
    • 0036150965 scopus 로고    scopus 로고
    • European Concerted Action on Anticoagulation. Use of plasma samples to derive international sensitivity index for whole-blood prothrombin time monitors
    • Poller L, Keown M, Chauhan N, et al. European Concerted Action on Anticoagulation. Use of plasma samples to derive international sensitivity index for whole-blood prothrombin time monitors. Clin Chem 2002;48:255-260
    • (2002) Clin Chem , vol.48 , pp. 255-260
    • Poller, L.1    Keown, M.2    Chauhan, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.