메뉴 건너뛰기




Volumn 36, Issue 9, 2003, Pages 1805-1817

Improvement of a CL-FIA system using maltose phosphorylase for the determination of phosphate-ion in freshwater

Author keywords

Cation exchange resin; Flow injection analysis; Freshwater; Luminol chemiluminescence; Maltose phosphorylase; Phosphate ion determination

Indexed keywords

FRESH WATER; MALTOSE PHOSPHORYLASE; PHOSPHATE; PHOSPHORYLASE; UNCLASSIFIED DRUG;

EID: 0043063954     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-120023615     Document Type: Article
Times cited : (20)

References (19)
  • 1
    • 0000807711 scopus 로고
    • The determination of inorganic phosphate in the presence of labile phosphate esters
    • Lowry, O.H.; Lopez, J.A. The determination of inorganic phosphate in the presence of labile phosphate esters. J. Biol. Chem. 1946, 162, 421-428.
    • (1946) J. Biol. Chem. , vol.162 , pp. 421-428
    • Lowry, O.H.1    Lopez, J.A.2
  • 4
    • 0039907244 scopus 로고    scopus 로고
    • Flow-injection potentiometric detection of phosphate using a metallic cobalt wire ion-selective electrode
    • Chem, Z.; Marco, R.D.; Alexander, P.W. Flow-injection potentiometric detection of phosphate using a metallic cobalt wire ion-selective electrode. Anal. Communi. 1997, 34, 93-95.
    • (1997) Anal. Communi. , vol.34 , pp. 93-95
    • Chem, Z.1    Marco, R.D.2    Alexander, P.W.3
  • 6
    • 0022796499 scopus 로고
    • Single-enzyme-based amperometric assay for phosphate ion
    • Ngo, T.T. Single-enzyme-based amperometric assay for phosphate ion. Appl. Biochem. Biothechnol. 1986, 13, 127-131.
    • (1986) Appl. Biochem. Biothechnol. , vol.13 , pp. 127-131
    • Ngo, T.T.1
  • 7
    • 0025109707 scopus 로고
    • Phosphate-sensitive enzyme electrode: A potential sensor for environment control
    • D'Urso, E.M.; Coulet, P.R. Phosphate-sensitive enzyme electrode: a potential sensor for environment control. Anal. Chim. Acta 1990, 239, 1-5.
    • (1990) Anal. Chim. Acta , vol.239 , pp. 1-5
    • D'Urso, E.M.1    Coulet, P.R.2
  • 9
    • 0027272916 scopus 로고
    • Effect of enzyme ratio and enzyme loading on the performance of a bienzymatic electrochemical phosphate biosensor
    • D'Urso, E.M.; Coulet, P.R. Effect of enzyme ratio and enzyme loading on the performance of a bienzymatic electrochemical phosphate biosensor. Anal. Chim. Acta 1993, 281, 535-542.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 535-542
    • D'Urso, E.M.1    Coulet, P.R.2
  • 10
    • 0029061287 scopus 로고
    • A novel enzyme sensor for the determination of inorganic phosphate
    • Conrath, N.; Grundig, B.; Huwel, K.; Cammann, K. A novel enzyme sensor for the determination of inorganic phosphate. Anal. Chim. Acta 1995, 309, 47-52.
    • (1995) Anal. Chim. Acta , vol.309 , pp. 47-52
    • Conrath, N.1    Grundig, B.2    Huwel, K.3    Cammann, K.4
  • 11
    • 0035850586 scopus 로고    scopus 로고
    • Trienzymatic biosensor for the determination of inorganic phosphate
    • Mousty, C.; Cosnier, S.; Shan, D.; Mu, S. Trienzymatic biosensor for the determination of inorganic phosphate. Anal. Chim. Acta 2001, 443, 1-8.
    • (2001) Anal. Chim. Acta , vol.443 , pp. 1-8
    • Mousty, C.1    Cosnier, S.2    Shan, D.3    Mu, S.4
  • 12
    • 0000096485 scopus 로고
    • Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode
    • Kubo, I.; Inagawa, M.; Sugawara, T.; Arikawa, Y.; Karube, I. Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode. Anal. Lett. 1991, 24, 1711-1727.
    • (1991) Anal. Lett. , vol.24 , pp. 1711-1727
    • Kubo, I.1    Inagawa, M.2    Sugawara, T.3    Arikawa, Y.4    Karube, I.5
  • 17
    • 0032850132 scopus 로고    scopus 로고
    • Development of a highly sensitive CL-FIA sensor for phosphate ion detection using maltose phosphorylase
    • Nakamura, H.; Hasegawa, M.; Nomura, Y.; Arikawa, Y.; Matsukawa, R.; Ikebukuro, K.; Karube, I. Development of a highly sensitive CL-FIA sensor for phosphate ion detection using maltose phosphorylase. J. Biotech. 1999, 75, 127-133.
    • (1999) J. Biotech. , vol.75 , pp. 127-133
    • Nakamura, H.1    Hasegawa, M.2    Nomura, Y.3    Arikawa, Y.4    Matsukawa, R.5    Ikebukuro, K.6    Karube, I.7
  • 18
    • 0033571481 scopus 로고    scopus 로고
    • An automatic flow-injection analysis system for determining phosphate ion in river water using pyruvate oxidase G (from Aerococcus viridans)
    • Nakamura, H.; Tanaka, H.; Hasegawa, M.; Masuda, Y.; Arikawa, Y.; Ikebukuro, K.; Karube, I. An automatic flow-injection analysis system for determining phosphate ion in river water using pyruvate oxidase G (from Aerococcus viridans). Talanta 1999, 50, 799-807.
    • (1999) Talanta , vol.50 , pp. 799-807
    • Nakamura, H.1    Tanaka, H.2    Hasegawa, M.3    Masuda, Y.4    Arikawa, Y.5    Ikebukuro, K.6    Karube, I.7
  • 19
    • 0000657467 scopus 로고
    • A new chromatographic method for the determination of thiamine and its mono-, di-, and triphosphates in animal tissues
    • Rindi, G.; Giuseppe, L. A new chromatographic method for the determination of thiamine and its mono-, di-, and triphosphates in animal tissues. Biochem. J. 1961, 78, 602-606.
    • (1961) Biochem. J. , vol.78 , pp. 602-606
    • Rindi, G.1    Giuseppe, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.