메뉴 건너뛰기




Volumn 12, Issue 9-10, 1997, Pages 959-966

A chemiluminescent FIA biosensor for phosphate ion monitoring using pyruvate oxidase

Author keywords

Arthromyces ramosus peroxidase; Chemiluminescence; Flow injection analysis; Phosphate ion; Pyruvate oxidase

Indexed keywords

CHEMILUMINESCENCE; ENZYMES; IONS; MONITORING; PHOSPHATES; QUALITY CONTROL;

EID: 0031277624     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(97)00032-8     Document Type: Article
Times cited : (37)

References (15)
  • 2
    • 0027469274 scopus 로고
    • Determination of L-glutamate and L-glutamine by flow injection analysis and chemiluminescence detection: Comparison of an enzyme column and enzyme membrane sensor
    • Blankenstein G., Preuschoff F., Spohn U., Mohr K. H., Kula M. R. Determination of L-glutamate and L-glutamine by flow injection analysis and chemiluminescence detection: comparison of an enzyme column and enzyme membrane sensor. Anal. Chim. Acta. 271:1993;231-237.
    • (1993) Anal. Chim. Acta , vol.271 , pp. 231-237
    • Blankenstein, G.1    Preuschoff, F.2    Spohn, U.3    Mohr, K.H.4    Kula, M.R.5
  • 3
    • 0029061287 scopus 로고
    • A novel enzyme sensor for the determination of inorganic phosphate
    • Conrath N., Grundig B., Huwel K., Cammann K. A novel enzyme sensor for the determination of inorganic phosphate. Anal. Chim. Acta. 309:1995;47-52.
    • (1995) Anal. Chim. Acta , vol.309 , pp. 47-52
    • Conrath, N.1    Grundig, B.2    Huwel, K.3    Cammann, K.4
  • 4
    • 0025109707 scopus 로고
    • Phosphate-sensitive enzyme electrode: A potential sensor for environmental control
    • D'Urso E. M., Coulet P. R. Phosphate-sensitive enzyme electrode: a potential sensor for environmental control. Anal. Chim. Acta. 239:1990;1-5.
    • (1990) Anal. Chim. Acta , vol.239 , pp. 1-5
    • D'Urso, E.M.1    Coulet, P.R.2
  • 5
    • 0016837550 scopus 로고
    • A phosphate selective electrode based on immobilized alkaline phosphatase and glucose oxidase
    • Guilbault G. G., Nanjo M. A phosphate selective electrode based on immobilized alkaline phosphatase and glucose oxidase. Anal. Chim. Acta. 78:1975;69-74.
    • (1975) Anal. Chim. Acta , vol.78 , pp. 69-74
    • Guilbault, G.G.1    Nanjo, M.2
  • 6
    • 0010580403 scopus 로고
    • Determination of L-lactate by differential pulse polarography with covalently immobilized enzyme on Chitopearl
    • Hasebe K., Hikima S., Yoshida H. Determination of L-lactate by differential pulse polarography with covalently immobilized enzyme on Chitopearl. Fresnius J. Anal.Chem. 339:1991;261-263.
    • (1991) Fresnius J. Anal.Chem. , vol.339 , pp. 261-263
    • Hasebe, K.1    Hikima, S.2    Yoshida, H.3
  • 9
    • 49949123410 scopus 로고
    • Phosphorus in flowing waters
    • Keup L. L. Phosphorus in flowing waters. Water Res. 2:1968;373-386.
    • (1968) Water Res. , vol.2 , pp. 373-386
    • Keup, L.L.1
  • 11
    • 0000096485 scopus 로고
    • Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode
    • Kubo I., Inagawa M., Sugawara T., Arikawa Y., Karube I. Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode. Anal. Lett. 24:1991;1711-1727.
    • (1991) Anal. Lett. , vol.24 , pp. 1711-1727
    • Kubo, I.1    Inagawa, M.2    Sugawara, T.3    Arikawa, Y.4    Karube, I.5
  • 13
    • 0025784569 scopus 로고
    • An FIA biosensor system for the determination of phosphate
    • Male K. B., Luong J. H. T. An FIA biosensor system for the determination of phosphate. Biosensors & Bioelectronics. 6:1991;581-587.
    • (1991) Biosensors & Bioelectronics , vol.6 , pp. 581-587
    • Male, K.B.1    Luong, J.H.T.2
  • 14
    • 0023521664 scopus 로고
    • Determination of phosphate ions with an enzyme sensor system
    • Watanabe E., Endo H., Toyama K. Determination of phosphate ions with an enzyme sensor system. Biosensors. 3:1988;297-306.
    • (1988) Biosensors , vol.3 , pp. 297-306
    • Watanabe, E.1    Endo, H.2    Toyama, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.