메뉴 건너뛰기




Volumn 75, Issue 2-3, 1999, Pages 127-133

Development of a highly sensitive chemiluminescence flow-injection analysis sensor for phosphate-ion detection using maltose phosphorylase

Author keywords

Arthromyces ramosus peroxidase; Chemiluminescence; Flow injection analysis; N Hydroxysuccinimide beads; Phosphate sensor

Indexed keywords

BIOSENSORS; CHEMILUMINESCENCE; ENZYME IMMOBILIZATION; ENZYME KINETICS; ORGANIC ACIDS; PHOSPHATES;

EID: 0032850132     PISSN: 01681656     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-1656(99)00150-9     Document Type: Article
Times cited : (30)

References (16)
  • 1
    • 0029061287 scopus 로고
    • A novel enzyme sensor for the determination of inorganic phosphate
    • Conrath N., Grundig B., Huwel K., Cammann K. A novel enzyme sensor for the determination of inorganic phosphate. Anal. Chim. Acta. 309:1995;47-52.
    • (1995) Anal. Chim. Acta , vol.309 , pp. 47-52
    • Conrath, N.1    Grundig, B.2    Huwel, K.3    Cammann, K.4
  • 2
    • 0025109707 scopus 로고
    • Phosphate-sensitive enzyme electrode: A potential sensor for environmental control
    • D'Urso E.M., Coulet P.R. Phosphate-sensitive enzyme electrode: a potential sensor for environmental control. Anal. Chim. Acta. 239:1990;1-5.
    • (1990) Anal. Chim. Acta , vol.239 , pp. 1-5
    • D'Urso, E.M.1    Coulet, P.R.2
  • 3
    • 0016837550 scopus 로고
    • A phosphate selective electrode based on immobilised alkaline phosphatase and glucose oxidase
    • Guilbault, G.G., Nanjo, M., 1975. A phosphate selective electrode based on immobilised alkaline phosphatase and glucose oxidase. Anal. Chim. Acta 78, 69-74.
    • (1975) Anal. Chim. Acta , vol.78 , pp. 69-74
    • Guilbault, G.G.1    Nanjo, M.2
  • 4
    • 0030576667 scopus 로고    scopus 로고
    • Highly sensitive chemiluminescence flow injection analysis system using microbial peroxidase and a photodiode detector
    • Hayashi K., Sasaki S., Ikebukuro K., Karube I. Highly sensitive chemiluminescence flow injection analysis system using microbial peroxidase and a photodiode detector. Anal. Chim. Acta. 329:1996;127-134.
    • (1996) Anal. Chim. Acta , vol.329 , pp. 127-134
    • Hayashi, K.1    Sasaki, S.2    Ikebukuro, K.3    Karube, I.4
  • 7
    • 49949123410 scopus 로고
    • Phosphorus in flowing waters
    • Keup L.L. Phosphorus in flowing waters. Water Res. 2:1968;373-386.
    • (1968) Water Res. , vol.2 , pp. 373-386
    • Keup, L.L.1
  • 8
    • 0000096485 scopus 로고
    • Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode
    • Kubo I., Inagawa M., Sugawara T., Arikawa Y., Karube I. Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode. Anal. Lett. 24:1991;1711-1727.
    • (1991) Anal. Lett. , vol.24 , pp. 1711-1727
    • Kubo, I.1    Inagawa, M.2    Sugawara, T.3    Arikawa, Y.4    Karube, I.5
  • 9
    • 0000807711 scopus 로고
    • The determination of inorganic phosphate in the presence of labile phosphate esters
    • Lowry O.H., Lopez J.A. The determination of inorganic phosphate in the presence of labile phosphate esters. J. Biol. Chem. 162:1946;421-428.
    • (1946) J. Biol. Chem. , vol.162 , pp. 421-428
    • Lowry, O.H.1    Lopez, J.A.2
  • 10
    • 0025784569 scopus 로고
    • An FIA biosensor system for the determination of phosphate
    • Male K.B., Luong J.H.T. An FIA biosensor system for the determination of phosphate. Biosens. Bioelectron. 6:1991;581-587.
    • (1991) Biosens. Bioelectron. , vol.6 , pp. 581-587
    • Male, K.B.1    Luong, J.H.T.2
  • 12
    • 0033571481 scopus 로고    scopus 로고
    • An automatic FIA system for determining phosphate ion in river water using pyruvate oxidase G (from Aerococcus viridans)
    • (in press)
    • Nakamura, H., Tanaka, H., Hasegawa, M., Masuda, Y., Arikawa, Y., Ikebukuro, K., Karube, I., 1999. An automatic FIA system for determining phosphate ion in river water using pyruvate oxidase G (from Aerococcus viridans). Talanta (in press).
    • (1999) Talanta
    • Nakamura, H.1    Tanaka, H.2    Hasegawa, M.3    Masuda, Y.4    Arikawa, Y.5    Ikebukuro, K.6    Karube, I.7
  • 15
    • 0023521664 scopus 로고
    • Determination of phosphate ions with an enzyme sensor system
    • Watanabe E., Endo H., Toyama K. Determination of phosphate ions with an enzyme sensor system. Biosensors. 3:1988;297-306.
    • (1988) Biosensors , vol.3 , pp. 297-306
    • Watanabe, E.1    Endo, H.2    Toyama, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.